• Title/Summary/Keyword: DC transmission

Search Result 477, Processing Time 0.022 seconds

Effect of Interference from DC Power Supply on Power Line Communication Channel (전력선 통신 채널에서 직류전원 공급장치의 간섭 영향)

  • Kim, Sungeon;Jeon, Taehyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.111-115
    • /
    • 2014
  • Power line communications can be utilized to build up the data transmission network wherever the electricity is available. This type of communication system could provide a basis for the network construction in many application areas which include the smart grid and home networks. On the other hand the power line communication is vulnerable to various types of interferences and noises. Also, its channel characteristics are constantly changing depending on the type and the amount of electrical loads connected to the network. Especially, the usage of DC power supply has been increased due to the explosive expansion of smart devices in our daily lives which result in the increased level of interferences on the power line channel. In this paper, the effect of the operation of the DC power supplies on the channel characteristics and the data transmission performance is analyzed through the experiments.

Short Circuit Tests of the Three-Phase DC Reactor Type Fault Current Limiter in Changing of Turns Ratio of Transformers (변압기 권선비의 변화에 따른 3상 DC 리액터형태 한류기의 단락실험)

  • Lee, Eung-Ro;Lee, Chan-Ju;Lee, Seung-Je;Go, Tae-Guk;Hyeon, Ok-Bae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.267-272
    • /
    • 2002
  • This Paper deals with the short circuit tests of the three-Phase DC reactor type fault current limiter (FCL) in changing of turns ratio of transformers. The experiment of this paper is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. So, superconducting coil was made of Nb-Ti, low temperature superconductor, and the ratings of the power system of experimental circuit are 400V/7A class. A three-phase DC reactor type FCL consists of three transformers, six diodes, one superconducting coil and one cryostat. The important point of experimental analysis is transient period, the operating lagging time of circuit breaker. As the results of the experiment, the values are referred to the limitation rate about 77% and 90% when the turns ratio of transformer was 1:1 and 2:1 respectively.

The Effect of Substrate DC Bias on the Low -Temperature Si homoepitaxy in a Ultrahigh Vacuum Electron Cyclotron Resonance Chemical Vapor Deposition (초고진공 전자 사이클로트론 화학 기상 증착 장치에 의한 저온 실리콘 에피 성장에 기판 DC 바이어스가 미치는 영향)

  • 태흥식;황석희;박상준;윤의준;황기웅;송세안
    • Journal of the Korean Vacuum Society
    • /
    • v.2 no.4
    • /
    • pp.501-506
    • /
    • 1993
  • The spatial potential distribution of electron cyclotron resonance plasma is measured as a function of tehsubstrate DC bias by Langmuir probe method. It is observed that the substrate DC bias changes the slope of the plasma potential near the subsrate, resulting in changes in flux and energy of the impinging ions across plasma $_strate boundary along themagnetric field. The effect of the substrate DC bias on the low-temperature silicon homoepitaxy (below $560^{\circ}C$) is examine dby in situ reflection high energy electron diffraction (RHEED), cross-section transmission electron microscopy (XTEM),plan-view TEM and high resolution transmision electron microscopy(HRTEM). While the polycrystalline silicon layers are grow withnegative substrate biases, the single crystaline silicon layers are grown with negative substrate biases, the singel crystalline silicon layers are grown with positive substrate biases. As the substrate bias changes form negative to positive values, the growth rate decreases. It is concluded that the control of the ion energy during plasma deposition is very important in silicon epitaxy at low temperatures below $560^{\circ}C$ by UHV-ECRCVD.VD.

  • PDF

A Study on the Reliability Analysis in LVDC Distribution System Considering Layout (저압직류 배전계통의 구성 형태를 고려한 공급신뢰도 분석에 관한 연구)

  • Kim, Chung-Mo;No, Chul-Ho;Han, Joon;Oh, Yun-Sik;Kim, Hyun-Soo;Baek, In-Ho;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • At the end of the 19th century, Edison's DC power system and Tesla's AC power system was debated in power market. Finally, AC system became the primary system of the power market because both step-up and step-down of voltage by using transformer and long-distance power transmission are easily possible. However, nowadays the power market takes some action for introducing DC system. Both domestic and foreign researchers are conducting the study on the DC system as well. Some researchers have conducted the studies on power quality and economic evaluation of the DC distribution system but DC distribution system is still controversial in terms of the effectiveness and reliability. In this paper, we calculate the reliability indices of the Low Voltage Direct Current(LVDC) distribution system considering arrangement of power electronics, layout of the distribution system, and distance between load points.

DEPOSITION OF c-BN FILMS BY PULSED DC BIASING IN MAGNETICALLY ENHANCED ARE METHOD

  • Lee, S.H.;Byon, E.S.;Lee, K.H.;J., Tian;Yoon, J.H.;Sung, C.;Lee, S.R.
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.467-471
    • /
    • 1999
  • BN films were grown on silicon (l00) substrate by magnetically enhanced activated reactive evaporation (ME-ARE) with pulsed DC power instead of r.f. for substrate biasing. The deposited films were analyzed using Fourier transform infrared spectroscopy (FTIR) and transmission electron microscopy (TEM). FTIR results show that the intensity of absorption band of $sp^2$ bond of BN decreased and that of $sp^3$ bond of c-BN increased with increasing pulsed DC bias voltage applied to substrate. The initially grown layer at the interface was observed by TEM and considered to be of$ sp^2$-bonded BN. The cross-sectional and planar TEM micrographs show that the upper layer on the initial layer was the single phase c-BN. It is concluded that cubic boron nitride films could be synthesized by ME-ARE process with pulsed DC biasing.

  • PDF

Analysis of Effect of HVDC Transmission System on the Transient Stability (HVDC 송전망이 대형발전단지의 과도안정도에 미치는 영향 분석)

  • Jeon, Hyeok-Mo;Chun, Yeong-Han
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • The characteristics of Korean power systems are large capacity of generation sites and concentrated load in Seoul metropolitan area. According to the national generation facility plan, more generation facilities are needed to be constructed as the electrical demands are forecasted to increase. Moreover, the size of generation sites are expected to increase, too. Therefore transient stability problems become worse and worse. Recently, the necessity of HVDC has been raised to overcome the difficulty of constructing HVAC transmission lines. This paper shows the analysis of transient stability when HVDC transmission system is added to the power system consisting of large generation sites.

Design and tests of prototype HTS power transmission cables

  • Ha, Hong-Su;Jo, Yeong-Sik;Oh, Sang-Su;Seong, Gi-Cheol;Kwon, Yeong-Gil;Ryu, Gang-Sik;Cho, Jeon-Uk
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.280-284
    • /
    • 2000
  • The prototype high-T$_c$ superconducting (HTS) power transmission cables have been designed and fabricated multi layers of spirally wound HTS tapes. The cables were made Bi-2223 based Ag-sheathed HTS tapes, and tested in LN$_2$. Critical currents of 700A dc and better were achieved. The magnetic flux density and field direction were analyzed in the cable configuration. In this paper the results of analysis and tests of HTS power transmission cables were described.

  • PDF

New Communication Method using Pulse Width Information for Power Converter Parallel Operation (전력변환기 병렬운전을 위한 펄스폭 정보를 이용한 새로운 통신방식)

  • Dong-Whan Kim;Seong-Cheol Choi;Tuan-Vu Le;Sung-Jun Park;Seong-Mi Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_2
    • /
    • pp.1097-1108
    • /
    • 2023
  • Recently, demand for technology for energy economy and stable supply is increasing due to the increase in power demand of loads. The amount of DC power generation using new and renewable energy is noticeably increasing, and the use of DC power supplies is also increasing due to the increase in electric vehicles and digital loads. During parallel operation to increase the capacity of the power converter, the module bus method or the method using Can communication and serial communication has significant difficulties in smooth operation due to communication time delay for information sharing. Synchronization of information sharing of each power converter is essential for smooth parallel operation, and minimization of communication time delay is urgently needed as a way to overcome this problem. In this paper, a new communication method using pulse width information is proposed as a communication method specialized for parallel operation of power converters to compensate for the disadvantage of communication transmission delay in the existing system. The proposed communication method has the advantage of being easily implemented using the PWM and Capture function of the microcomputer. In addition, the DC/DC converter for DC distribution was verified through simulation and experiment, and it has the advantage of easy capacity expansion when applied to parallel operation of various types of power converters as well as DC/DC converters.

Transcutaneous Energy Transmission with Double Tuned Duty Cycle Control (양단 공진과 듀티 컨트롤을 이용한 1-2cm 공극을 통한 에너지 전달)

  • Kim, Chang-Gyun;Cho, Bo-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.486-488
    • /
    • 1996
  • A dc-dc converter which transfers l2-48W of power(regulated output voltage 24V) across a large, variable air gap(1-2cm) has been designed. This converter employs double resonance to compensate the large leakage inductance of the primary and secondary of the transcutaneous transformer. To maximize the effect of resonance, a constant frequency, duty cycle control method is used. The duty cycle control presents advantages over a frequency control in terms of increase in dc voltage gain and reduction of the primary current. The analysis and design procedure for the proposed scheme is presented and the performance result is simulated and verified experimentally.

  • PDF

EMTDC Modeling Method of DC Reactor type Superconducting Fault Current Limiter

  • Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.56-59
    • /
    • 2003
  • As electric power systems grow to supply the increasing electric power demand short-circuit current tends to increase and impose a severe burden on circuit breakers and power system apparatuses. Thus, all electric equipment in a power system has to he designed to withstand the mechanical and thermal stresses of potential short-circuit currents. Among current limiting devices, Fault Current Limiter (FCL) is expected to reduce the short-circuit current. Especially, Superconducting Fault Current Limiters (SFCL) offer ideal performance: in normal operation the SFCL is in its superconducting state and has negligible impedance, in the event of a fault, the transition into the normal conducting state passively limits the current. The SFCL using high-temperature superconductors offers a positive resolution to controlling fault-current levels on utility distribution and transmission networks. This study contributes to the EMTDC based modeling and simulation method of DC Reactor type SFCL. Single and three phase faults in the utility system with DC reactor type SFCLs have been simulated using EMTDC in order to coordinate with other equipments, and the results are discussed in detail.