• Title/Summary/Keyword: DC transmission

Search Result 477, Processing Time 0.03 seconds

Two Factors Failure Model of Oil-Paper Insulation Aging under Electrical and Thermal Multistress

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.957-963
    • /
    • 2014
  • Converter transformers play important roles in high-voltage direct current transmission systems. This paper presents experimental and analysis results of the combined electrical and thermal aging of oil-impregnated paper at pulsating DC voltages. Breakdown voltages and time-to-breakdown of oil-paper specimens were measured by using short-time and constant-stress tests. The breakdown characteristics of combined electrical and thermal aging on insulation system were discussed. According to the relationship between failure time and aging temperature, the two-parameter Weibull model was improved. On the basis of the competing risk algorithm and the improved Weibull model, the two factors failure model was calculated. And the influence of temperature in the insulation system has been analyzed. This model performs better than the two-parameter Weibull model when both time and temperature are considered as variables in estimating the lifetime of oil-paper insulation.

Influence of Electrical Aging on Space Charge Dynamics of Oil-Impregnated Paper Insulation under AC-DC Combined Voltages

  • Wang, Yan;Li, Jian;Wu, Sicheng;Sun, Peng
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1512-1519
    • /
    • 2013
  • Oil-impregnated paper is a major type of insulation used in oil-filled converter transformers for both traditional and new energy systems. This paper presents and analyzes the results of the experiment conducted on the electrical aging of oil-impregnated paper under AC-DC combined voltages using the pulsed electro-acoustic (PEA) technique. The formation and dynamics of space charge affected the performance of insulation material. The electrical aged oil-paper insulation was obtained through electrical aged experiments under the voltages. Based on the PEA technique, measurements were carried out when the oil-paper insulation system was subjected to different stressing and aging times. The space charge dynamics in the bulk of the oil-paper insulation system with different aging times were measured and analyzed. Characteristic parameters such as the total charge injection amount, the total charges of fast moving and slow moving, and the distortion factor of electric field were calculated and discussed. Results show that the longer electrical aging time, the more charges trapped in the bulk of aging sample. It leads to larger distortion factor of electric field in the bulk of aging samples and accelerate degradation of oil-paper insulation under AC-DC combined voltages.

Harmonics based loss characteristics analysis of HTS DC power cable (고조파에 의한 초전도 직류 전력케이블의 손실 특성 분석)

  • Kim, S.K.;Kim, S.H.;Park, M.W.;Yu, I.K.;Lee, S.J.;Cho, J.W.;Sim, K.D.;Won, Y.J.;Hwang, S.D.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.3
    • /
    • pp.19-23
    • /
    • 2011
  • An HTS DC power cable is expected to perfectly eliminate transmission loss caused by resistance. However, when the HTS DC power cable is applied to the power system, loss of the HTS DC power cable is generated due to harmonics caused by HVDC converter. We designed and analyzed the HTS DC power cable with a critical current of 1 kA to investigate the loss characteristics using a finite element method package. In this paper, the loss characteristics caused by harmonics in the HTS DC power cable were analyzed according to order and magnitude of harmonics. Based on the analysis results, the critical current of HTS DC power cable considered with the rated current could be determined to minimize the capacity of cooling system for the design the HTS DC power cable.

Maximum Power Point Tracking Control for a Grid-Tie Photovoltaic Inverter (계통 연계형 태양광 인버터에서 최대 출력 점 추적 제어)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.72-79
    • /
    • 2009
  • Solar energy is desirable due to its renewable and pollution-free properties. In order to utilize the present utility grid infrastructure for power transmission and distribution, a do-dc boost converter and grid connected dc-to-ac inverters are needed for solar power generation. The dc-dc boost converter allows the PV system to operate at high do-link voltage. The single-phase inverter provides the necessary voltage and frequency for interconnection to the grid. In this paper, first, current loop transfer function of a single-phase grid-tie inverter has been systematically derived Second the MPPT of conductance increment method at converter side is proposed to supply the maximum power to the inverter side. Simulation results are shown to access the performance of PV system and its behaviour at the interconnection point.

DC-link Voltage Control of HVDC for Offshore Wind Farm using Improved De-loading Method (개선된 De-loading기법을 이용한 해상풍력 연계용 HVDC의 DC 전압의 제어방안)

  • Huh, Jae-Sun;Moon, Won-Sik;Park, Sang-In;Kim, Doo-Hee;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.399-404
    • /
    • 2015
  • This paper presents the DC voltage control method in DC link of High Voltage Direct Current(HVDC) for an offshore wind farm in Low Voltage Ride Through(LVRT) situation. Wind generators in an offshore wind farm are connected to onshore network via HVDC transmission. Due to LVRT control of grid side inverter in HVDC, power imbalancing in DC link is generated and this consequentially causes rising of DC voltage. A de-loading scheme is one of the method to protect the wind power system DC link capacitors from over voltage. But the flaw of this method is slow control response time and that it needs long recovery time to pre-fault condition after fault clear. Thus, this paper proposes improved de-loading method and we analyze control performance for DC voltage in LVRT control of HVDC for an offshore wind farm.

An Efficient Design of a DC-Block Band Pass Filter for the L-Band

  • Kaur, Avneet;Malhotra, Jyoteesh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.62-65
    • /
    • 2017
  • In this paper, three DC Block designs are presented which efficiently meet the need of modern-day compactsize wireless communication systems. As one of the important parts of a complete system design, the proposed microstrip-based DC block with coupled transmission lines efficiently attenuates unwanted frequencies that cause damage to the system. The compact-sized DC block structures are created by incorporating an extended coupled-line section with a radial stub, an enveloped coupled-line section, and using alternate up-down meandering techniques. The structures are analyzed for the L-Band using a high-resistive silicon substrate. At a resonating frequency of 1.575 GHz, the designed DC Block structures have a return loss better than -10 dB, an insertion loss of around -1 dB, and also possess wide pass-band characteristics.

Optimal Power Flow of DC-Grid Based on Improved PSO Algorithm

  • Liu, Xianzheng;Wang, Xingcheng;Wen, Jialiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1586-1592
    • /
    • 2017
  • Voltage sourced converter (VSC) based direct-current (DC) grid has the ability to control power flow flexibly and securely, thus it has become one of the most valid approaches in aspect of large-scale renewable power generation, oceanic island power supply and new urban grid construction. To solve the optimal power flow (OPF) problem in DC grid, an adaptive particle swarm optimization (PSO) algorithm based on fuzzy control theory is proposed in this paper, and the optimal operation considering both power loss and voltage quality is realized. Firstly, the fuzzy membership curve is used to transform two objectives into one, the fitness value of latest step is introduced as input of fuzzy controller to adjust the controlling parameters of PSO dynamically. The proposed strategy was applied in solving the power flow issue in six terminals DC grid model, and corresponding results are presented to verify the effectiveness and feasibility of proposed algorithm.

A Study on Nonlinear Controller of DC Servo-motors with Harmonic Drive Gearing and Its Synchronous Operation (하모닉 드라이브를 가진 DC 서보 모터의 비선형 제어기와 동기 운전에 관한 연구)

  • 김연태;최정원;홍동기;이석규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.8
    • /
    • pp.60-70
    • /
    • 1998
  • A harmonic drive is compact torque transmission device with no backlash which is widely applied in industrial field to transmit torque precisely. However, one of the disadvantages of harmonic drives is the existence of mechanical flexibility caused by its structural properties, which imposes great limitation on designing precise controller This paper proposes a nonlinear controller for synchronous operation of DC servo-motors with harmonic drive, using Integrator Backstepping method. Furthermore, an alternative algorithm for serial type synchronous operation of multiple DC servo-motors is proposed. Simulation results by SIMULINK for proposed controller shows considerably small error and rapid approach to reference input, which can be adapted to industrial applications.

  • PDF

A Distance Relaying Algorithm Using an Improved Technique for Removing DC-offset (DC-Offset 제거 기능을 향상시킨 거리계전 알고리즘)

  • No, Jae-Keun;Kang, Sang-Hee;Nam, Soon-Ryul;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.118-120
    • /
    • 2001
  • This paper presents a distance relaying algorithm based on the Discrete Fourier Transform(DFT) for elimination of DC-Offset. When the DFT is applied to current signal. the real and imaginary parts of fundamental component consist of fundamental component itself and DC-Offset. The DC-Offset is calculated by four consecutive values of the imaginary components, so that the fundamental component can be accurately estimated. Performance evaluation is presented for A-phase ground faults on 154kV 80km overhead transmission line. The proposed algorithm is inspected by software simulation and hardware simulation.

  • PDF