• Title/Summary/Keyword: DC relay

Search Result 87, Processing Time 0.023 seconds

A Design Method of Iron-cored CTs To Prevent Satruation (포화를 방지하기 위한 보호용 철심 변류기 설계 방법)

  • Lee, Ju-Hun;Gang, Sang-Hui;Gang, Yong-Cheol;Lee, Seung-Jae;Bae, Ju-Cheon;An, Jun-Gi;Lee, Cheong-Hak;Lee, Jeong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current without exceeding 10% ratio error. However, the possibility of CT saturation still remains if the fault current contains substantial amounts of ac and/or dc components. This paper presents a design method of iron-cored CTs for use with protective relays to prevent CT saturation. The proposed design method determines the core cross section of the CT; it employs the transient dimensioning factor to consider relay's operating time (duty cycle) and dc component as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider the biggest fault current. The method designs the cross section of CTs in cases of reclosure and no reclosure.

  • PDF

EMTP-RV Modeling of CT Saturation (EMTP-RV를 이용한 CT포화 모델링)

  • Kang, Yong-Cheol;Choi, Jae-Sun;Zheng, Tai-Ying;Kang, Hae-Gweon;Jang, Sung-Il;Kim, Yong-Gyun;Ryu, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.9-11
    • /
    • 2008
  • A protection current transformer (CT) has been widely used for protection devices. When a fault occurs, a CT should provide the faithful reproduction of the primary fault current. However, a CT may saturates due to the magnitude of fault current, dc component primary time constant and the remanent flux of the iron core, and the secondary current of a CT is distorted. The distorted current can cause mal-operation or the operating time delay of a protection relay. This paper provides a modeling of CT saturation using EMTP-RV. The performance of the proposed CT saturation modeling was investigated under various fault conditions varying the fault distance, fault inception angle, and remanent flux of the iron core. The results indicate that the proposed EMTP-RV modeling can operate correctly, and the reasons for CT saturation are verified by EMTP-RV simulations.

  • PDF

Variable Output and Parallel Operation Control of EV Charger (전기자동차용 충전기의 가변출력 및 병렬운전 제어)

  • Lee, Sang-Hyeok;Kang, Seong-Gu;Awasthi, Prakash;Hwang, Jung-Goo;Lee, Seung-Yul;Wi, Han-Byul;Park, Sung-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.153-160
    • /
    • 2013
  • This research paper describes the development of battery charger with a variable output voltage capacity for charging the batteries used in electrical vehicles. The voltage and current accordingly is control via the buck converter that receives three phase current at primary side and fed to bridge rectifier which is comprised of full bridge converter and HFTR(High Frequency Transformer) for isolation and a square wave AC output. The transformer primary side is in series to divide certain charging current and the secondary side is comprised of six fix transformers so that they can generate certain amount of power and various output voltage through relay connection using 6 DC outputs. Moreover, all parallel connected full bridge serial resonant converter communicate together with upper(main) controller. The constructed structure is verified by conducting the test on PSIM as well as experimentally.

A FPGA Implementation of Digital Protective Relays for Electrical Power Installation (전력설비를 위한 디지털보호계전기의 FPGA 구현)

  • Kim, Jong-Tae;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.131-137
    • /
    • 2005
  • Protective relays provide important features to electrical power systems for protecting against faults and consequent short circuits. This research presents a novel VLSI design of the digital protective relay, which overcomes today's uP/DSP-based relays. This design features good cancellation of DC/k-th harmonic components, noticeable not performance and flexible Protection behavior in the minimized core area The proposed design was successfully implemented by a FPGA(Field Programmable Gate Array) device and can concurrently process over 16KSPS at less $0.03[\%]$ error rate.

VHDL Design of High Performance FIR Filter for Digital Protection Relay Using Least Square Algorithm (최소자승 알고리즘을 이용한 디지털 보호 계전기용 고성능 FIR 필터의 VHDL 모델 설계)

  • Shin, Jae-Shin;Kim, Jong-Tae;Park, Jong-Kang;Seo, Jong-Wan;Shin, Myung-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.345-347
    • /
    • 2003
  • 본 논문에서는 디지털 보호 계전기에 쓰이는 필터 중에서 최소 자승 알고리즘을 이용한 고성능 FIR 필터를 설계하였다. 기존의 DFT필터와 MATLAB 시뮬레이션을 이용하여 비교하였으며 FIR 필터의 VHDL모델 및 합성에 중점을 두었다. FIR 필터는 기본적으로 유한개의 임펄스 응답이 이루어지기 때문에 기타 다른 필터에 비하여 안정도가 높으며 선형적인 위상을 가지기 때문에 차단 주파수 대역의 왜곡현상을 없앨 수 있는 장점을 가지고 있다. 여러 가지 알고리즘으로 구현한 FIR 필터를 시뮬레이션 한 결과 최소 자승 알고리즘이 가장 우수한 결과를 나타내었다. 기본적으로 디지털 보호 계전기에서 디지털 필터의 기능은 사고 전압, 전류로부터 60Hz의 기본파 추출 CT, PT 왜곡 및 DC offset을 제거하는데 있다. 본 논문에서는 이러한 기능을 가지면서 샘플링 주파수와 차수를 같게 하여 FIR 필터와 DFT 필터의 주파수 응답과 연 산 속도를 비교 하였다. 본 논문에서 설계된 최소 자승 알고리즘을 이용한 FIR 필터는 같은 조건의 DFT필터에 비해 1고조파와 2고조파의 차이가 10db 이상 더 우수 하였으며 연산 속도 또한 2배 이상 좋은 결과를 보였다.

  • PDF

A Study on Operation Method of Protection Device for LVDC Distribution Feeder in Light Rail System (경전철용 LVDC 배전계통의 보호기기 운용 방안에 관한 연구)

  • Kang, Min-Kwan;Choi, Sung Sik;Lee, Hu-Dong;Kim, Gi-Yung;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.25-34
    • /
    • 2019
  • Recently, when a fault occurs at a long-distance point in a LVDC (low voltage direct current) distribution feeder in a light rail system, the magnitude of the current can decrease to less than that of the load current of a light rail system. Therefore, proper protection coordination method to distinguish a fault current from a load current is required. To overcome these problems, this paper proposes an optimal algorithm of protection devices for a LVDC distribution feeder in a light rail system. In other words, based on the characteristics of the fault current for ground resistance and fault location, this paper proposes an optimal operation algorithm of a selective relay to properly identify the fault current compared to the load current in a light rail system. In addition, this paper modelled the distribution system including AC/DC converter using a PSCAD/EMTDC S/W and from the simulation results for a real light rail system, the proposed algorithm was found to be a useful and practical tool to correctly identify the fault current and load current.

A Study on the Implementation of Zigbee Sensor Node for Building USN Using only Transmission of Fire Sensing Data (화재감지데이터 전송용 USN망 구축을 위한 지그비 센서노드 구현)

  • Cheon, Dong-Jin;Jung, Do-Young;Kwak, Dong-Kurl
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.75-81
    • /
    • 2009
  • In this paper, USN of wireless communication with easy to install and effectiveness with variety information gathering has been proposed as a alternative of wired-based line for transmission of fire sensing data. But, The sensor node using USN should be considered for wireless transmission range and reliability of information. In this study, the zigbee protocol sensor node was implemented and then tested transmission range of sensor node as 10m interval using voltage information of DC 3V & 5V. Here, maximum transmission distance was confirmed 90m inside-outside. When used mesh routing relay node, distance was not limited. In USN network building, when fire sensing data transmitted, the sensing data same between direct sensing data from sensor and collecting data at USN. Therefore, was confirmed reliability for transmission range and information of proposed zigbee sensor node.