• 제목/요약/키워드: DC load flow

검색결과 60건 처리시간 0.023초

DC 마이크로 그리드를 위한 Three-port Dual Active Bridge DC-DC 컨버터의 독립 전력 제어 (Decoupled Power Control of Three-port Dual Active Bridge DC-DC Converter for DC Microgrid Systems)

  • 심주영;이준영;최현준;김학선;정지훈
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.366-372
    • /
    • 2018
  • Three-port dual-active bridge (DAB) converter in a DC microgrid was studied due to its high power density and cost-effectiveness. The other advantages of DAB include galvanic isolation and bidirectional power conversion capability using simple control modulation. The three-port DAB converter consists of a three winding transformer and three bridges. The transformer has three phases, which means that the ports are coupled. Thus, the three-port DAB converter causes unwanted power flows when the load connected to each port changes. The basic operational principles of the three-port DAB converter are presented in this study. The decoupling control strategy of the independent port power transfer is presented with a mathematical power model to overcome the unexpected power flow problem. The validity of the proposed analysis and control strategy is verified with PSIM simulation and experiments using a 1-kW prototype power converter.

PPTC 소자를 사용한 저전압 직류차단기의 아크소호기술 (Arc Extinguishment for Low-voltage DC (LVDC) Circuit Breaker by PPTC Device)

  • 김용중;나재호;김효성
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.299-304
    • /
    • 2018
  • An ideal circuit breaker should supply electric power to loads without losses in a conduction state and completely isolate the load from the power source by providing insulation strength in a break state. Fault current is relatively easy to break in an Alternating Current (AC) circuit breaker because the AC current becomes zero at every half cycle. However, fault current in DC circuit breaker (DCCB) should be reduced by generating a high arc voltage at the breaker contact point. Large fire may occur if the DCCB does not take sufficient arc voltage and allows the continuous flow of the arc fault current with high temperature. A semiconductor circuit breaker with a power electronic device has many advantages. These advantages include quick breaking time, lack of arc generation, and lower noise than mechanical circuit breakers. However, a large load capacity cannot be applied because of large conduction loss. An extinguishing technology of DCCB with polymeric positive temperature coefficient (PPTC) device is proposed and evaluated through experiments in this study to take advantage of low conduction loss of mechanical circuit breaker and arcless breaking characteristic of semiconductor devices.

송전망 이용요금 산정을 위한 교육용 시뮬레이터 개발 (A Windows-based Software for Education and Training of Transmission Network Charge)

  • 김현홍;조기선;정윤원;박종배;신중린
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1373-1381
    • /
    • 2007
  • This paper presents a graphical windows-based software for the education and training of transmission network charge. The motivation for the development of the simulator is to provide students with a simple and useable tool for gaining an intuitive feel for transmission network charge. The developed simulator consists of the main module (MMI, GUI), the power flow module (PF), the power flow tracing module (PFT), and usage cost DB module (UCD). Each module has a separate graphical and interactive interfacing window. The developed simulator provides with two power system analysis methods (i.e., DC-PF and Modified DC-PF) and supports the PSS/E input data format to load input data of power system. Also, power flow tracing can be calculate using four methods such as "Felix Wu", "Modified Felix Wu", "DCLF ICRP", and "Reverse MW mile". Results of calculation for transmission usage cost are displayed and compared on the window through the table and/or chart. Therefore, the developed simulator can be utilize as a useful tool for effective education and training of transmission network charge.

Experimental performance characteristics of 1 kW commercial PEM fuel cell

  • Shubhaditya Kumar;Pranshu Shrivastava;Anil Kumar
    • Advances in Energy Research
    • /
    • 제8권4호
    • /
    • pp.203-211
    • /
    • 2022
  • The aim of this paper is to analyze the performance of commercial fuel cell (rated capacity 1000W) with the help of resistive load and output power variation with change in H2 flow rate and calculate the maximum power point (MPP) of the proton exchange membrane (PEM) while changing AC and DC load respectively. The factors influencing the output power of a fuel cell are hydrogen flow rate, cell temperature, and membrane water content. The results show that when the H2 flow rate is changed from 11, 13, and 15 Lpm, MPP is increased from lower to higher flow rate. The power of the fuel cell is increased at the rate of 29% by increasing the flow rate from 11 to 15 lpm. This study will allow small-scale industries and residential buildings (in remote or inaccessible areas) to characterize the performance of PEMFC. Furthermore, fuel cell helps in reducing emission in the environment compared to fossil fuels. Also, fuel cells are ecofriendly as well as cost effective and can be the best alternative way to convert energy.

V2G-V2H 기능을 갖는 3.3kW급 전기자동차용 양방향 충전기 (A 3.3kW Bi-directional EV Charger with V2G and V2H function)

  • 정세형;홍석용;박준성;최세완
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.31-37
    • /
    • 2015
  • This paper proposes a 3.3-kW bi-directional EV charger with V2G and V2H functions. The bi-directional EV charger consists of a DC-DC converter and a DC-AC inverter. The proposed EV charger is suitable for wide battery voltage control due to the two-stage configuration of the DC-DC converter. By employing a fixed-frequency series loaded resonant converter as the isolated DC-DC converter, zero-current-switching can be achieved regardless of battery voltage variation, load variation, and power flow. A 3.3-kW prototype of the proposed EV charger has been built and verified with experiments, and indicates a maximum efficiency of 94.39% and rated efficiency of 94.23%.

Novel High Step-Up DC/DC Converter Structure Using a Coupled Inductor with Minimal Voltage Stress on the Main Switch

  • Moradzadeh, Majid;Hamkari, Sajjad;Zamiri, Elyas;Barzegarkhoo, Reza
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2005-2015
    • /
    • 2016
  • A high-step-up DC/DC converter for renewable energy systems is proposed. The proposed structure provides high voltage gain by using a coupled inductor without the need for high duty cycles and high turn ratios. The voltage gain is increased through capacitor-charging techniques. In the proposed converter, the energy of the leakage inductors of the coupled inductor is reused. This feature reduces the stress on the switch. Therefore, a switch with low ON-state resistance can be used in the proposed converter to reduce losses and increase efficiency. The main switch is placed in series with the source. Therefore, the converter can control the energy flow from the source to the load. The operating principle is discussed in detail, and a steady state analysis of the proposed converter is conducted. The performance of the proposed converter is verified by experimental results.

New ZVZCT Bidirectional DC-DC Converter Using Coupled Inductors

  • Qian, Wei;Zhang, Xi;Li, Zhe;Jin, Wenqiang;Wiedemann, Jochen
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.11-23
    • /
    • 2019
  • In this study, a novel zero voltage zero current transition (ZVZCT) bidirectional DC-DC converter is proposed by employing coupled inductors. This converter can turn the main switch on at ZVZCT and it can turn it off with zero voltage switching (ZVS) for both the boost and buck modes. These characteristics are obtained by using a simple auxiliary sub-circuit regardless of the power flow direction. In the boost mode, the auxiliary switch achieves zero current switching (ZCS) turn-on and ZVS turn off. Due to the coupling inductors, this converter can make further efficiency improvements because the resonant energy in the capacitor or inductor can be transferred to the load. The main diode operates with ZVT turn-on and ZCS turn-off in the boost mode. For the buck mode, there is a releasing circuit to conduct the currents generated by the magnetic flux leakage to the output. The auxiliary switch turns on with ZCS and it turns off with ZVT. The main diode also turns on with ZVT and turns off with ZCS. The design method and operation principles of the converter are discussed. A 500 W experimental prototype has been built and verified by experimental results.

Analysis and Design of Sliding Mode Control for a Single-Phase AC-DC Converter

  • Sawaengsinkasikit, Winyu;Tipsuwanporn, Vittaya;Tarasantisuk, Chanlit
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2291-2294
    • /
    • 2003
  • In this paper, analysis and control design of ac-dc converter, normally nonlinear time-varying system, using sliding mode controller to achieve fast output voltage response, disturbance rejection and robust system in the presence of load variation are demonstrated. The objective of this method is to develop methodology for output voltage to be constant and input current sinusoidal that results in nearly unity power factor, respectively. In addition the converter can be also bidirectional power flow. Simulation results using Matlab/Simulink show the effectiveness of sliding mode control system compared with linear feedback controller to guarantee enhanced PF>0.98, THD<5%, and ripple output voltage is less than 1% at the maximum output power.

  • PDF

단자망을 이용한 직류전기철도 해석방안에 관한 연구 (A Study on Analysis Method of DC Electric Railroad using Terminal Network Analysis)

  • 이장무;장동욱;김재원;한문섭;정환수;김주락
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1913-1918
    • /
    • 2016
  • In order to analyze the power consumption pattern of the DC urban rail system, the method to obtain a solution establishing the current equation according to fixed position of the substation and varying position of the train is used. The proposed analysis method using the network analysis is to model the transfer function of the component constituting a direct current power supply system (dc substation, train, catenary) to the voltage and current. By multiplying the model formula consecutive, it can calculate the voltage and current of each element of power supply circuit and shows a simple case analysis.

회생차량을 포함한 급전시스템 해석 알고리즘 (The Computer Algorithm for DC Traction Power Supply System Analysis Including Regenerative Braking Vehicles)

  • 정상기;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.639-646
    • /
    • 2003
  • Nowadays traction motors in the urban rail transit vehicle are controlled by VVVF inverter and have capability of regenerative braking. The algorithms to deal with the regenerating vehicle in simulation for the DC traction power supply is introduced in this paper. Substations have to be separated from the system to represent reverse biased rectifiers in substations. The model of the trains in regenerative braking has to be changed from the ideal current source to the constant voltage source since the train input voltage has to be controlled below the certain train maximum voltage. Some mismatches are unevitable because the constraint of the regenerated power can not be imposed with the constant voltage source. The mismatches represent the unused regenerated power. A computer program is developed to verify the validity of the algorithm. The test run result shows the program behaves as it is expected and proves the algorithm's validity.