• Title/Summary/Keyword: DC interaction

Search Result 97, Processing Time 0.029 seconds

A Dynamic Analysis of Distribution Network for SCP (DC와 DC의 상호작용을 고려한 분배망 분석 기법)

  • Na, Yun-Ji;Ko, Il-Seok;Cho, Dong-Wook
    • The KIPS Transactions:PartD
    • /
    • v.10D no.7
    • /
    • pp.1207-1212
    • /
    • 2003
  • As development of the e-commerce, the distributing network for a logistics currency is more complicated. A management of the distributing network (DN) is important factor in distribution planning. The DN can be expressed to distribution center (DC) and the interaction of DC. An internal factor of DC and an external factor to occur by an interaction of DC have many influences on the DN. Therefore, for an efficient DN management plan, analysis of the DN that considered DC and an interaction of DC is required. Until now a study on a viewpoint of supply chain management as resources assignment was performed, but the study on analysis of the distribution network was not performed. This paper propose the distribution network analysis technique that considered DC and an interaction of DC. A proposed technique consists of two steps largely. First of all a DN is expressed with the graph that included an interaction of DC and DC. It uses a reachibility tree, and the following, a DN expressed with a graph is analyzed. Also we presented an example model, and show an usefulness of proposal technique with the analysis of this model.

Input Impedances of PWM DC-DC Converters: Unified Analysis and Application Example

  • Pidaparthy, Syam Kumar;Choi, Byungcho
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2045-2056
    • /
    • 2016
  • The input impedances of pulse width modulated (PWM) dc-to-dc converters, which dictate the outcomes of the dynamic interaction between dc-to-dc converters and their source subsystem, are analyzed in a general and unified manner. The input impedances of three basic PWM dc-to-dc converters are derived with both voltage mode control and current mode control. This paper presents the analytical expressions of the 24 input impedances of three basic PWM dc-to-dc converters with the two different control schemes in a factorized time-constant form. It also provides a comprehensive reference for future dynamic interaction analyses requiring knowledge of the converters' input impedances. The theoretical predictions of the paper are all supported by measurements on prototype dc-to-dc converters. The use of the presented results is demonstrated via a practical application example, which analyzes the small-signal dynamics of an input-filter coupled current-mode controlled buck converter. This elucidates the theoretical background for the previously-reported eccentric behavior of the converter.

Synaptotagmin 5 Controls SYP132-VAMP721/722 Interaction for Arabidopsis Immunity to Pseudomonas syringae pv tomato DC3000

  • Kim, Soohong;Kim, Hyeran;Park, Keunchun;Cho, Da Jeong;Kim, Mi Kyung;Kwon, Chian;Yun, Hye Sup
    • Molecules and Cells
    • /
    • v.44 no.9
    • /
    • pp.670-679
    • /
    • 2021
  • Vesicle-associated membrane proteins 721 and 722 (VAMP721/722) are secretory vesicle-localized arginine-conserved soluble N-ethylmaleimide-sensitive factor attachment protein receptors (R-SNAREs) to drive exocytosis in plants. They are involved in diverse physiological processes in plants by interacting with distinct plasma membrane (PM) syntaxins. Here, we show that synaptotagmin 5 (SYT5) is involved in plant defense against Pseudomonas syringae pv tomato (Pst) DC3000 by regulating SYP132-VAMP721/722 interactions. Calcium-dependent stimulation of in vitro SYP132-VAMP722 interaction by SYT5 and reduced in vivo SYP132-VAMP721/722 interaction in syt5 plants suggest that SYT5 regulates the interaction between SYP132 and VAMP721/722. We interestingly found that disease resistance to Pst DC3000 bacterium but not to Erysiphe pisi fungus is compromised in syt5 plants. Since SYP132 plays an immune function to bacteria, elevated growth of surface-inoculated Pst DC3000 in VAMP721/722-deficient plants suggests that SYT5 contributes to plant immunity to Pst DC3000 by promoting the SYP132-VAMP721/722 immune secretory pathway.

The Study of Steady-State Interaction Between AC and DC Lines on the Same Transmission Tower (AC 및 DC 송전 선로 병렬 연계에 따른 정상상태 커플링 영향 분석)

  • Yoon, Jong-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1221-1225
    • /
    • 2010
  • The application of the AC and DC lines on the same transmission tower is an economical and practical approaching that increase the power transmission capacity of an existing transmission corridor. But, In this case, Inductive and capacitive coupling between AC and DC lines on the same tower should be investigated in advance. According to the installation plan of 80kV ${\pm}$60MW bipole HVDC in Cheju, KOREA that will be commissioned until 2011, DC lines will parallely operate with 154kV 2 AC lines in existed 154kV AC 4 lines transmission tower. This paper presents the steady state analysis results about the interaction between 154kV AC and 80kV DC lines in the same transmission tower.

The Impact of Interaction Factors of Digital Contents on Flow and Use Intention (디지털콘텐츠의 상호작용요인이 몰입과 사용의도에 미치는 영향)

  • Kim, Chang-Su;Lee, Sung-Ho;Oh, Eun-Hae
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.212-224
    • /
    • 2011
  • Users in the Web 2.0 era, which is based on the convergence of wired and wireless technologies, tend to have a high regard for digital contents interactions, as compared to the technology experienced at the analog era. To boost the digital contents business, it is necessary to focus on the digital contents(DC) interactions based on user-centered thinking to satisfy user preferences. According to previous studies, this study classified DC interactions into three types: interaction between users, interactions between contents and users, and interactions between system and users. This study empirically verifies that DC interactions factors affect flow as well as DC flow influences the DC use intention.

Electical Transport Properties of La$_{1.6}$Ca$_{1.4}$Mn$_2$O$_{7.07}$ System (La$_{1.6}$Ca$_{1.4}$Mn$_2$O$_{7.07}$의 전기전도특성)

  • 정우환
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.8
    • /
    • pp.843-847
    • /
    • 1999
  • The dc resistivity dc magnetization and thermopower of layered perovskite La1.6Ca1.4Mn2O7.07 have been studied. The ceramic sample of La1.6Ca1.4Mn2O7.07 undergoes the metal-insulator transition at 120K while a first-order phase transition from a ferromagnetic phase to a paramagnetic phae is observed at 260 K=TC This behavior is quite different from that of the well-known double exchange ferromagnets such as La1-xCaxMnO3 This phenomenon could be understood by considering the effects of the anisotropic double exchange interaction caused by two dimensional Mn-O-Mn networks in this materials. The dc magnetization between 120K and 250K is nearly constant and decreases rapidly with increasing temperature above 250K The measurements of dc resistivity and thermopower indicate that Zener polaron hopping conduction takes place above 260 K.

  • PDF

Computations of Line Reactor Parameters and DC Bus Capacitance for Inverter (인버터의 선형 리액터 파라미터와 DC 버스 용량 계산)

  • Chen, Dezhi;Chai, Wenping;Kwon, Byung-il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.968-969
    • /
    • 2015
  • This paper proposes a novel analysis method for calculating inverter DC bus capacitance and line reactor parameters. In the realization process, DC bus capacitance parameter, and ripple current, life of DC bus capacitor, interaction between DC bus capacitance can be calculated by using Newton-Raphson procedure. The design scheme of DC bus capacitor and line reactor, specific parameters such as capacitance, loss, ripple current, central average temperature, life, ripple current, loss, size, central temperature of the reactor were given. Simulation results show that this scheme can accurately calculate the DC bus capacitance and line reactor parameters. Compared with calculation result of references, cost and volume are half. The indicators meet the demand of practical engineering. It had affirmed precision of the analytical method and verified correctness and feasibility of this method.

  • PDF

An analysis and control of double chopper DC-DC converter (이중 쵸퍼 DC-DC 컨버터의 해석과 제어)

  • Han, Sang-Wan;Sin, Dong-Hee;Hong, Seok-Gyo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.576-581
    • /
    • 1997
  • DC-DC converter with chopper is seen to have problems, such as, loop instability and degradation of transient response, due to the interaction between input filter and switching regulator. In this paper, the switching regulator consisting of input filter and double chopper is analyzed, and the state space model at continuous current mode and the transfer function between duty ratio of switching pulse and output voltage are derived. The controller in this paper is designed as feedforward(P) and feedback(PI) control scheme to minimize the variation of output voltage, and computer simulation results are presented to show the performance of the proposed controller.

  • PDF

A STUDY ON SOLUTION AGAINST CORE SATURATION INSTABILITY AT AN HVDC CONVERTER

  • Yang Byeong-Mo;Kim Chan-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.591-599
    • /
    • 2001
  • The paper identifies a severe form of core saturation instability in an DC/AC interaction system. It then seeks solutions to the problem by HVDC control means. This is achieved by a proper design of the Voltage Dependent Current Order Limiter (VDCOL), the Current Regulator and Timing Pulse generator. Supplementary control loops have also been introduced to result in a satisfactory performance as compared to that obtained one with the use of uncharacteristic harmonic filter on the AC side. Robustness of all the options has been demonstrated through recovery performance of the DC link in response to both I-phase and 3-phase 5 cycle faults on both rectifier and inverter commutating buses.

  • PDF

Stability Analysis Using G-Parameters of Converters Constituting DC Microgrid and Stability Enhancement Through Virtual Impedance (G-parameter를 이용한 직류 마이크로그리드의 컨버터 상호 안정도 분석 및 가상 임피던스를 이용한 안정도 향상)

  • Lee, Jae-Suk;Lee, Gi-Young;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.321-327
    • /
    • 2018
  • DC microgrid system composed of multiple converters has a tendency to make the system unstable due to the interaction of converters. To solve this problem, in this paper, the interaction between cascaded converters with LC input filter is analyzed with impedance modeling using g-parameter. The input impedance and the output impedance of the system can be obtained through this technique. The stability of the system can be determined by applying Middlebrook's stability criterion to the impedance. Virtual impedance is added to the controller to enhance stability. The validity of the analysis is verified by the result of several simulations and experiments.