• 제목/요약/키워드: DC Traction power supply system

검색결과 37건 처리시간 0.027초

정전압 DC 급전시스템에서의 회생전력모의를 위한 조류계산 알고리즘 (Loadflow algorithm for Fixed voltage DC Electric Power Supply System)

  • 정상기;이병송;정낙교;박성혁;이승재
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.335-342
    • /
    • 2001
  • The problems in the loadflow study of the fixed voltage DC traction power supply system including the regeneration power is analyzed. And the computer algorithm to avoid the problem is developed. A computer program using the developed algorithm was developed. A test run of the computer program is conducted and the result shows the algorithm and the program developed is very effective for the loadflow study of the system including the regeneration power.

  • PDF

DC 급전시스템의 지락보호계전시스템 개발 (Development of Ground Fault Protective Relaying Schemes for DC Traction Power Supply System)

  • 정상기;정락교;조홍식;이안호;권삼영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권9호
    • /
    • pp.427-433
    • /
    • 2005
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot Identify the faulted region which causes long traffic delays and safety problem to passengers. Two new ground fault protective relay schemes that can identify the faulted region are presented in this paper. One is bus differential protective relay and the other is ground overcurrent protective relay. Both type of relays is similar in principle to the ordinary bus differential protective relay and the ground overcurrent relay used in other power system. In DC traction power supply system, since it is ungrounded, ground fault current is not big enough to operate those relays. To solve the problem, a current control device, called device 'X', is newly introduced in both system, which enables large amount of ground fault current flow upon the positive line to ground fault. Algorithms for these relays are developed and their validity are verified by EMTP simulation.

직류전철용 전력공급 장치의 에너지희생에 관한 연구 (A study on energy regeneration of power supply for DC electric traction system)

  • 방효진;장수진;송상훈;원충연;김용기;안규복
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.439-442
    • /
    • 2004
  • This paper described a dc power system, which can generate the excessive do power form do bus line to ac source in substation for traction system. The proposed regeneration inverter system for dc traction can be used as both an inverter and an active power filter(APF). As a regeneration inverter mode, it can recycle regenerative energy caused by decelerating tractions and as an active power filter mode, it can compensate for harmonic distortion produced by the rectifier substation.

  • PDF

경전철 시험선용 전력공급시스템 설계 (The design of the traction power supply for the test line of Light Rail Vehicle)

  • 김국진;백병산;전용주;정상기;김남규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 추계학술대회 논문집
    • /
    • pp.322-328
    • /
    • 2001
  • In the electric railway systems, it is very important that we should design the system configuration, location and power capacity of substation. This paper presents the results of system configuration and system design of the DC traction power supply for the test line of Light Rail Vehicle. The voltage fluctuation of train and the power capacity of substation are calculated by computer simulation using the nodal equation, K.C.L/K.V.L, Ohm's law and superposition theory.

  • PDF

슈퍼 커패시터를 이용한 직류철도 회생에너지 저장장치 (DC Traction Regenerative Energy Storage Devices using Super-capacitor)

  • 김종윤;정두용;장수진;이병국;원충연
    • 전력전자학회논문지
    • /
    • 제13권4호
    • /
    • pp.247-256
    • /
    • 2008
  • 직류철도의 회생제동 시 발생되는 회생에너지는 급전선로의 직류가선전압의 상승에 의해 시스템의 오동작이나 차량 정류기의 파손, 또는 급전 시스템의 전력변환 장치의 고장을 일으키는 원인이 될 수 있다. 슈퍼 커패시터를 이용한 회생에너지 저장장치는 직류가선전압을 안정화 하게하는 방법이다. 본 논문에서는 슈퍼 커패시터 뱅크를 이용하여 직류철도 시스템의 에너지 저장장치를 구현하였고, 지하철 2호선 N역과 S역의 실측값을 이용하여 가선전압이 전동차에 의한 회생에너지 발생에 따른 동작 특성과 슈퍼 커패시터의 충 방전 특성을 확인하였다. 본 논문을 통하여 직류철도 시스템에 설치된 회생에너지 저장시스템용 슈퍼 커패시터 뱅크의 동작 특성을 알 수 있고, 향 후 직류철도 모든 변전소의 직류 가선전압 실측 데이터를 이용한다면, 특정 직류철도 운행 구간에 대한 회생에너지 저장장치의 운전특성과 슈퍼커패시터의 용량 및 수명 예측으로 가격을 절감 할 수 있고 전체 시스템의 안정도 와 신뢰성을 향상시킬 수 있다.

DC 비접지 급전계통 선택차단형 통합보호계전기 시뮬레이터 개발 및 알고리즘 테스트 (Development of a Simulator and Algorithm Test for Selective-breaking Integrated Protective Relay for Ungrounded DC Traction Power Supply System)

  • 안태풍;윤준석;정태영;김인웅;정호성
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.899-904
    • /
    • 2012
  • In recent years, a lot of research was done for earth fault protection in ungrounded dc power supply system. As a result, selective-breaking integrated protective relaying system is developed in progress and is currently field-testing are planned. Algorithm on a PC using PSCAD done a lot of testing before performing field tests, but in this study developed algorithms and functions needed to determine whether they were operating normally. Therefore, simulated system is similar to the actual situation was required and made. selective-breaking algorithm verification and validation was performed with simulator.

비접지 DC 급전시스템에서의 Delta-I 지락보호계전 시스템 (Development of Delta-I ground fault Protective Relaying Scheme for DC Traction Power Supply System)

  • 정상기;권삼영;정호성;김주락
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.529-535
    • /
    • 2006
  • In DC tracking power supply system, ground faults are currently detected by the potential relay, 64P. Though 64P relay detects ground fault, it cannot identify the faulted region which causes long traffic delays and safety problem to passengers. A new ground fault protective relay scheme, ${\Delta}I$ ground fault protective relay, that can identify the faulted region is presented in this paper. In ${\Delta}I$ ground fault protective relaying scheme, ground fault is detected by 59, overvoltage relay, which operates ground switch installed between the negative bus and the ground. It preliminarily chooses the faulted feeder after comparing the current increases among feeders and trips the corresponding feeder breaker. After some time delay, it then recloses the breaker if it finds the preselected feeder is not the actual faulted feeder. Whether or not the preselected feeder is the actual faulted feeder is determined by checking the breaker trip status in the neighboring substation in the direction of the tripped breaker. If the corresponding breaker in the neighboring substation is also tripped, it finally judges the preselected feeder is actually a faulted feeder. Otherwise it recloses the tripped breaker. Its algorithms is presented and verified by EMTP simulation.

경량전철 전력공급시스템의 용량 산정에 관한 연구 (A Study on Capacity Calculation of Power Supply System for Light Rail Transit)

  • 백병산;서광덕;김종구
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.696-703
    • /
    • 2000
  • This paper describes the capacity calculation of power supply system for light Rail Transit Three factors are considered for the design i.e. substation arrangements, line configuration and substation power capacity. In this study, we considered all of them for capacity calculation of power supply system for LRT. At first DC-fed-traction system is introduced on an outline, a characteristics of train and fed network, and design method of substation arrangements. Optimal design procedures are described, and program for capacity calculation of the system is presented. In addition, the computer simulated results are computed with the conventional simple calculation method.

  • PDF

SVPWM을 이용한 직류전력 회생시스템의 역률개선에 관한 연구 (A Study on the Power Factor Improvement of DC Power Regenerating Systems Using SVPWM)

  • 고영민;채수용;서영민;정대택;배영욱;홍순찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.196-198
    • /
    • 2007
  • In the substations for traction systems and the large-scale discharging system of secondary batteries, the voltage of DC bus line goes up by the regenerated energy and the energy is usually wasted in resistor for system stability. This paper proposes the DC power regenerating system using a three phase PWM inverter. The proposed system can regenerate the excessive DC power from DC bus line to AC supply and control the power factor of AC supply to unity. To implement unity power factor, the magnitude of the inverter output voltage should be higher than that of AC supply and therefore SVPWM technique is adopted. Computer simulations are carried out to verify the validity of the proposed system.

  • PDF

고조파 저감 능력을 가진 직류전철 회생인버터 시스템 (Regeneration Inverter System for DC Traction with Hormonic Reduction Capability)

  • 원충연;장수진;김용기;방효진;송상훈;안규복
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.96-104
    • /
    • 2004
  • 본 논문에서는 전철시스템의 변전소에서 직류모선에 발생하는 잉여분의 직류전력을 교류전원 측으로 회생시킬 수 있는 직류전력 회생시스템을 제안한다. 제안된 직류 전철용 회생인버터 시스템은 인버터와 능동전력필터로 사용할 수 있다. 회생인버터 모드에서는 전철의 감속에 의해 회생되는 에너지를 재사용 할 수 있으며, 능동전력필터 모드에서는 변전소의 정류기에 의해 발생되는 고조파 왜곡을 보상하기 위해 사용할 수 있다. 전력용량과 스위칭 손실을 고려하여 시스템은 3상 PWM 인버터를 기반으로 설계되며 병렬인버터, 출력변압기와LCL필터로 구성된다.