• Title/Summary/Keyword: DC Pulse Signal

Search Result 88, Processing Time 0.02 seconds

Pulse Detection from PPG Signal with Motion Artifact using Independent Component Analysis and Nonlinear Auto-correlation (독립 성분 분석과 비선형 자기상관을 이용한 동잡음이 포함된 PPG 신호에서의 맥박 검출)

  • Jeon, Hak-Jae;Kim, Jeong-Do;Lim, Seung-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.71-78
    • /
    • 2016
  • PPG signal measured by pulse oximeter can measure pulse and the oxygen saturation of arterial blood. But the PPG signal is distorted by finger movement or other movement in the body. To detect pulse from the PPG signal with motion artifact, we use band pass filter(BPF), Independent component analysis(ICA) and nonlinear autocorrelation(NAC). BPF is used to remove DC component and high frequency noise in the PPG signal with motion artifacts. ICA is used to separate pulse signal and motion artifact. However, pulse signal separated by ICA have no choice but to accompany signal distortion because pulse signal and motion artifact are not completely independent. So, we use nonlinear autocorrelation to emphasize the pure pulse signal from the distorted signal.

DC voltage control by drive signal pulse-width control of full-bridged inverter

  • Ishikawa, Junichi;Suzuki, Taiju;Ikeda, Hiroaki;Mizutani, Yoko;Yoshida, Hirofumi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.255-258
    • /
    • 1996
  • This paper describes a DC voltage controller for the DC power supply which is constructed using the full-bridged MOS-FET DC-to-RF power inverter and rectifier. The full-bridged MOS-FET DC-to-RF inverter consisting of four MOSFET arrays and an output power transformer has a control function which is able to control the RF output power when the widths of the pulse voltages which are fed to four MOS-FET arrays of the fall-bridged inverter are changed using the pulse width control circuit. The power conversion efficiency of the full-bridged MOS-FET DC-to-RF power inverter was approximately 85 % when the duty cycles of the pulse voltages were changed from 30 % to 50 %. The RF output voltage from the full-bridged MOS-FET DC-to-RF inverter is fed to the rectifier circuit through the output transformer. The rectifier circuit consists of GaAs schottky diodes and filters, each of which is made of a coil and capacitors. The power conversion efficiency of the rectifier circuit was over 80 % when the duty cycles of the pulse voltages were changed from 30 % to 50 %. The output voltage of the rectifier circuit was changed from 34.7V to 37.6 V when the duty cycles of the pulse voltages were changed from 30 % to 50 %.

  • PDF

An Optical Pulse-Width Modulation Generator Using a Single-Mode Fabry-Pérot Laser Diode

  • Tran, Quoc-Hoai;Nakarmi, Bikash;Won, Yong Hyub
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.255-259
    • /
    • 2015
  • We have proposed and experimentally verified a pulse-width modulation (PWM) generator which directly generated a PWM signal in the optical domain. Output waveforms were clear at the repetition rate of 16 MHz; the duty cycle (DC) was from 14.7% to 72.1%; and the DC-control resolution was about 4.399%/dB. The PWM generator' operation principle is based on the injection-locking property of a single-mode Fabry-$P{\acute{e}}rot$ laser diode (SMFP-LD). The SMFP-LD, which has a self-locked mode wavelength at ${\lambda}_{PWM}$, was used to detect the power of the injection-locking signal (optical analog input). If the analog input power is high, the SMFP-LD is locked to the wavelength of the input signal ${\lambda}_a$ and there is no output after an optical bandpass filter (OBF). If the analog input power is low, the SMFP-LD is unlocked and there is output signal at ${\lambda}_{PWM}$ after the OBF. Thus, the SMFP-LD plus the OBF provide digital output for an analog input. The DC of the output PWM signal can be controlled by tuning the power of the analog input.

Characteristics comparison of food parallel type high frequency resonant inverter by driving signal control method (구동신호 제어기법에 의한 부하병렬형 고주파 인버터의 특성비교)

  • 이봉섭;원재선;김동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.94-102
    • /
    • 2003
  • This paper describes the load parallel type full-bridge high frequency resonant inverter can be used as power source. Output control method of proposed circuit is compared with pulse frequency modulation(PFM), pulse width modulation(PWM) and pulse phase variation(Phase-Shift). The analysis of the proposed circuit is generally described by using the normalized parameters. The principle of basic operating and the its characteristics are estimated according to the parameters such as switching frequency(${\mu}$), pulse width($\theta$d) the variation of phase angle($\phi$) by three driving signal patterns. Experimental results are presented to verify the theoretical analysis result. In future, Characteristics by three driving signal control method is provided as useful data in case of output control of a power supply in various fields as induction heating application, DC-DC converter etc.

A Development of Pulse Oximeter module for Measurement of $SpO_2$ (산소포화도 측정을 위한 모듈형 펄스 옥시메터 개발)

  • 이한욱;이주원;이종회;조원래;이건기
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.3
    • /
    • pp.575-583
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the $SpO_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have been required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. Therefore we simplify the calculation algorithm for $SpO_2$. The implemented system have the high performance such an accuracy and a processing time than the traditional method.

  • PDF

Speed Control of DC Motor for Roller Type Seeder (롤러형 파종기 구동용 직류모터의 회전속도 제어)

  • 이중용;김유용;박상래
    • Journal of Biosystems Engineering
    • /
    • v.25 no.5
    • /
    • pp.351-358
    • /
    • 2000
  • This study was conducted to develop a speed control system of a DC motor which drove a barley seeder mounted on a combine harvester. Barley seeder mounted on a combine has been known to reduce labor and cost of barley cultivation. However, development of the seeder has been unsuccessful because the combine, a dedicated rice and barley harvester has not enough space and proper power take-off for barley seeder. To develop a barley seeder, small powered motor speed controller was required. A proximity sensor for detecting working speed of the combine and a programmable one board microprocessor was used to develope a control system. Motor parameters and motor constant, relationship between seeding rate, motor speed, groove volumes of a tested roller, torque were measured. The proximity sensor sent a frequency signal to the microprocessor. In laboratory experiments, the excitation voltage of the motor was shown not to be proportional to the size of pulse width (duty ratio). A table transforming frequency signal, that represented for working speed to proper pulse width was developed from seeding rate experiments. However, seeding rate at low frequency signal was not proportional to the working speed. Seeding rate control proportional to the frequency signal was achieved by shifting of the frequency signal.

  • PDF

An Improvement of Signal Processing of Pulse Oximeter Using Modulization (모듈화를 이용한 펄스 옥시메터의 신호처리 개선)

  • 이한욱;이주원;이종희;조원래;장두봉;김영일;이건기
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.117-120
    • /
    • 2000
  • Pulse oximetry is a well established non-invasive optical technique for monitoring the SpO$_2$ during anaesthesia, recovery and intensive care. Pulse oximeters determine the oxygen saturation level of blood by measuring the light absorption of arterial blood. The sensors consists of red and infrared light sources and photodetectors. In the measurement of the hemoglobin oxygen saturation, conventional method has required the technique of filtering of remove the noise, and of complex signal processing algorithm. So much time have required to signal processing. In this research, we separate AC signal and DC signal in the stage of signal detection. We filter the noise from each signal and convert A/D. We obtain the SpO$_2$ using the DSP algorithm.

  • PDF

Speed Control of DC Servo Motor using FPGA (FPGA를 이용한 DC Servo Motor의 속도제어)

  • Park, In-Soo;Seo, Young-Won;Park, Kwang-Hyeon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.313-315
    • /
    • 2009
  • In this thesis, A methodology of system implement for PID controller, PWM logic, HSC logic, Host Communication and external DAC interface are implemented into single FPGA chip is proposed. The implemented system is used to control the speed of DC servo motor. A DATA block transfers set point value(SV) and P, I, D gain parameters to the corresponding Blocks respectively by the Host Communication to Computer. A HSC block generates process value(PV) by a pulse and $90^{\circ}$ shifted pulse from the encoder A PID block makes error(E) signal from the set value and process value and output manufacture value(MV) through the PID controller. In PWM block using the MV from the PID block, drives H-bridge controlling the Motor. Also DAC interface controls the DAC to graph the digital signal such as SV, PV, E, MV in FPGA onto the Oscilloscope.

  • PDF

Pulsed Power Modulator based on IGBTs (IGBT 기반 고압 펄스전원장치)

  • Ryoo, H.J.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.43-46
    • /
    • 2007
  • In this paper, a novel new pulse power generator based on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9 power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is important for series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used. Proposed scheme has lots of advantages such as long lifecyle, compact size, flat topped pulse forming, small weight, protection for arc, high efficiency and flexibility to generate various kinds of pulse output.

  • PDF

Development of 60KV Pulse Power Supply using IGBT Stacks (IGBT 직렬구동에 의한 60KV 펄스 전원장치 개발)

  • Ryoo, H.J.;Kim, J.S.;Rim, G.H.;Sytykh, D.;Gussev, G.I.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.917-918
    • /
    • 2006
  • In this paper, a novel new pulse power generatorbased on IGBT stacks is proposed for pulse power application. Proposed scheme consists of series connected 9power stages to generate maximum 60kV output pulse and one series resonant power inverter to charge DC capacitor voltage. Each power stages are configured as 8 series connected power cells and each power cell generates up to 850VDC pulse. Finally pulse output voltage is applied using total 72 series connected IGBTs. The synchronization of gating signal is importantfor series operation of IGBTs. For gating signal synchronization, full bridge inverter and pulse transformer generates on-off signals of IGBT gating and specially designed gate power circuit was used.

  • PDF