• 제목/요약/키워드: DC Power Supply

검색결과 968건 처리시간 0.03초

DC급전 시스템 가전기기의 안정성 규격 정립을 위한 AC 기기 규격분석 및 방향제시 (A Suggestion of Direction for Safety Standards Setup of Appliances in DC Power Supply System on Analysis of AC Appliances Standards)

  • 안정훈;구근완;김동희;이병국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.356-358
    • /
    • 2010
  • 본 논문은 DC 가전기기의 '안정성 규격' 정립을 위한 연구를 수행한다. 첫째, AC 기기와 DC 기기의 차이점을 비교하고 둘째, AC 가전기기의 국제적 안전 규격을 분석한다. 이에 따라 AC 기기가 DC 기기로 변화할 때, DC 안정성의 규격정립을 위한 많은 항목 중 무엇을 어떻게 보완해야 하는지 그 방향과 논점을 AC 기기 규격을 바탕으로 하여 제시한다.

  • PDF

Design of DC-DC Boost Converter with RF Noise Immunity for OLED Displays

  • Kim, Tae-Un;Kim, Hak-Yun;Baek, Donkyu;Choi, Ho-Yong
    • Journal of Semiconductor Engineering
    • /
    • 제3권1호
    • /
    • pp.154-160
    • /
    • 2022
  • In this paper, we design a DC-DC boost converter with RF noise immunity to supply a stable positive output voltage for OLED displays. For RF noise immunity, an input voltage variation reduction circuit (IVVRC) is adopted to ensure display quality by reducing the undershoot and overshoot of output voltage. The boost converter for a positive voltage Vpos operates in the SPWM-PWM dual mode and has a dead-time controller using a dead-time detector, resulting in increased power efficiency. A chip was fabricated using a 0.18 um BCDMOS process. Measurement results show that power efficiency is 30% ~ 76% for load current range from 1 mA to 100 mA. The boost converter with the IVVRC has an overshoot of 6 mV and undershoot of 4 mV compared to a boost converter without that circuit with 18 mV and 20 mV, respectively.

전류형 고주파 공진 DC-DC 컨버터의 특성해석 (Characteristic analysis of the current type high frequency resonant DC - DC converter)

  • 황계호;남승식;김동희;심광열;안항목
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.86-93
    • /
    • 2003
  • 본 논문은 출력전류를 증가하기 위해서 L과 C를 공진 탱크회로로 구성하는 고주파 공진을 이용한 전류형 고주파 공진 U-U 컨버터를 보여주고 있다. 이 회로구성은 L과 C를 공진 탱크회로로 구성하였고, 스위칭 양단에 커패시터를 삽입하여 공진과 ZVS(Zero Voltage Switching) 커패시터로 동시에 사용하였다. 따라서, 컨버터는 턴ㆍ온, 턴ㆍ오프에서 스위칭 손실과 집음, 전압 스트레스를 줄일 수 있고, U전원 공급으로부터 리플이 적은 일정한 전류를 공급하기 위한 U 리액터는 공진 리액터와 연결되어 있기 때문에 부하 단락시 안정하게 동작하는 장점이 있다. 본 컨버터의 회로해석은 무차원화 파라미터 기법을 도입하여 행하였고, 또한 ZVS영역특성, 출력전력특성, 출력전압특성, 출력전류특성 등 여러 특성평가를 하였다. 여러 특성평가를 바탕으로 설계하였고, 실험을 통한 실험치와 이론치를 비교하여 이론해석의 정당성도 입증하였다.

육지-제주간 2차 HVDC SYSTEM 개요 (The Introduction of #2 HVDC SYSTEM)

  • 장석한;유승환;신명식;이규용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.107-109
    • /
    • 2008
  • Cheju-Haenam HVDC transmission system start it's commercial operation since 1998. JEJU island is supplied with it's about 45% of total electric power from main land with HVDC link. In JEJU island, the demand of electric power is growing every year. With a current power supply, electric power reserve rate will be below the recommended one. For a stable power supply to JEJU island, KEPCO start a construction of #2 HVDC transmission system. This report is for introduction and understanding of #2 HVDC system which will be installed between JEJU island and main land. This report includes a specification of converter station and DC cable. KEPCO expect that this system will solve the power supply problem and maximum wind power plant capacity problem as well.

  • PDF

Digital DC power supply for light accelerator

  • Kim, Yoon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권8호
    • /
    • pp.1000-1003
    • /
    • 2014
  • There are 70 vertical and 70 horizontal correctors for Pohang Light Source. Until mid of 2000, power supplies for these correctors were based on 1990's technology, so the global orbit feedback system was not possible with poor 12 bit resolution. A new task force team was assembled to develop new power supplies with BESSY type DAC cards. After the project, two vertical correctors in each lattice were connected with new power supplies, and the global orbit feedback was available within the accuracy of 5 microns. However, this replacement was not enough to satisfy the beam stability requirement of 2 microns for PLS. We have launched another power supply design based on all digital technology. This attempt was completed within a year, and 80 units were assembled in house. Currently, the global orbit feedback system is running successfully with new digital power supplies and the compensation of chamber motion due to the thermal load by using digital displacement transducers attached on each BPMs.

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

Single-phase SRM Drive with Torque Ripple Reduction and Power Factor Improvement

  • Lee, D.H.;Ahn, J.W.;Lee, Z.G.
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.57-61
    • /
    • 2006
  • In the single-phase switched reluctance motor (SRM) drive, the required DC source is generally supplied by the circuit consisting of bridge rectifier and large filter capacitor connected with DC line terminal. Due to the large capacity of the capacitor, the charged time of capacitor is very short from the AC source. Lead to the bridge rectifiers draws pulsating current from the AC source side, which results in reduction of power factor and low system efficiency. Therefore a novel single-phase SRM drive system is presented in this paper, which includes drive circuit realizing reduction of torque ripple and improvement of power factor with a novel switching topology. The proposed drive circuit consists of one switching part and diode, which can separate the output of AC/DC rectifier from the large capacitor and supply power to SRM alternately, in order to realize the torque ripple reduction and power factor improvement through the switching scheme. In addition, the validity of the proposed method is tested by some simulations and experiments.

  • PDF

A Power Control System for the Rod Drive Coil of Control Element Drive Mechanism in Pressurized Water Reactor

  • Hwang, Dong-Hwan;Seong, Se-Jin;Park, Gwang-Seok
    • Nuclear Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.1-8
    • /
    • 1999
  • In this paper, we propose a new type of power control system for the rod drive coil of the CEDM of the PWR NPP in order to supply more reliable DC power The electrical modelling of the controlled rod drive coil was done by referring related documentations. The design of the proposed system is based on this electric81 model satisfying the existing specification. A high power DC-DC converter scheme is adopted utilizing the SMPS technique in the design of the proposed system. In order to show the effectiveness of the proposed system, an experimental system with the capability of 3.2 K Watt was set up for a rod with four cores and some computer simulations and experimentations were carried out. The result shows a very similar tracking performance with that of the existing system to the driving command. As a result of this, the proposed method can be applied to the power control system for the rod drive coil of the CEDM of the PWR NPP.

  • PDF

구조물 능동진동제어를 위한 압전 작동기 구동 파워앰프와 제어 알고리즘 구현 시스템의 개발 (Development of Power Amplifier for Piezoelectric Actuator and Control Algorithm Realization System for Active Vibration Control of Structures)

  • 이완주;곽문규
    • 한국소음진동공학회논문집
    • /
    • 제22권2호
    • /
    • pp.170-178
    • /
    • 2012
  • This paper is concerned with the development of power amplifier and controller for piezoelectric actuator and sensor used in smart structures. Even though a high-voltage power amplifier is provided in the form of an operational amplifier, a very high DC voltage is still necessary as a power supply. In this study, we propose a low-cost design for the power amplifier including the DC power supply. We also need a controller on which a control algorithm will be mounted. In general, a digital signal processing chip is popularly used because of high speed. However, only commercial product is available for smart structure applications. In this paper, a controller consisting of a DSP and electronic circuits suitable for piezoelectric sensor and actuator pair is proposed. To validate the proposed controller with power amplifier, experiment on smart structure was carried out. The experimental results show that the proposed control system can be effectively used for smart structure applications with low cost.

능동 클램프형 포워드 DC-DC 컨버터의 효율에 관한 연구 (A Study on Efficiency of Active Clamp Type Forward DC-DC Converter)

  • 안태영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권5호
    • /
    • pp.351-357
    • /
    • 2004
  • In this paper, we present an analytical method that provides fast and efficient evaluation of the conversion efficiency for switching power supplies. In the proposed method, the conduction losses are evaluated by calculating the effective values of the ideal current waveform first and incorporating them into an exact equivalent circuit model of the switching power supply that includes all the parasitic resistances of the circuit components. While the winding losses and core losses are accurately accounted for the magnetic components, the skin and proximity effects are assumed to be negligible in order to simplify the analysis. The validity and accuracy of the proposed method are verified with experiments on a prototype active-clamped forward converter with synchronous rectification. An excellent correlation between the experiments and theories are obtained for the input voltages of 36-75 V with 4-6 MOSFETs employed for the synchronous rectification.