• 제목/요약/키워드: DC Cable

Search Result 128, Processing Time 0.024 seconds

Normal Zone Propagation Properties of Ag Sheathed Bi-2223 Tape for HTS Cable and Cylindrical Stacked Conductor (HTS 케이블용 은시스 Bi-2223 테이프 및 원통형 적층 도체의 상전도 영역전파 특성)

  • 이병성;김영석;장현만;백승명;김상현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.448-451
    • /
    • 2000
  • Normal zone propagation(NZP) characteristics were investigated on Ag sheathed Bi-2223 tape and cylindrical stacked conductor. Normal zone propagation(N2P) experiments with tape were conducted with refrigerator in temperature from 45 K to 77 K, 0 T. Cylindrical stacked conductor was molding with epoxy and experiments were conducted with adiabatic condition in $LN_2$. NZP velocities of tape with two condition of DC and AC were almost same at each temperature. NZP velocities of cylindrical stacked conductor were 1.9-2.4 cdsec in $LN_2$. Numerical analysis was carried out by a one-dimensional heat balance equation. As a result, simulated results of NZP velocity with Bi-2223 tape were similar to experimental results in DC.

  • PDF

A Study on Space Charge Distribution of HDPE Mixed with EVA (HDPE/EVA혼합수지의 공간 전하 분포에 관한 연구)

  • Jung, Eui-Hwan;Heo, Jun;Yoon, Jae-Hun;Lim, Kee-Joe;Lee, Hyung-Kyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2229-2235
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately, it resulted from extinction of space charge in the interfacial region of spherulites.

Composition Technology of Pulsed Power System with High Current (대전류 고속펄스파워시스템의 구성기술)

  • Lee, Hyeong-Ho;Seo, Kil-Soo;Kim, Young-Bae;Cho, Kook-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2179-2181
    • /
    • 1999
  • This paper describes the composition technology of pulsed power system with high current. The capacitor bank, control cabinet, dc charging unit, closing switch and cable system etc. employed with the system components are described. Especially the development of the inverse pinch switch enabled the generation of the very high current.

  • PDF

A Study of DC/AC Characteristics on 22.9 kV distribution class HTS-cable (22.9 kV 배전급 초전도케이블의 DC/AC 특성에 관한 연구)

  • Ma, Y.H.;Ryu, K.;Sohn, S.H.;Lim, J.H.;Hwang, S.D.;Choi, H.O.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.287-287
    • /
    • 2008
  • HTS-케이블은 구리도체 대신 고온초전도도체를 사용하여 저항이 0이 되는 초전도현상을 이용하여 대용량 전력수송이 가능한 전력케이블로서 대도시의 전력부하 집중문제를 해결할 수 있는 환경 친화적 전력케이블이다. 최근 고온초전도선재의 고임계전류밀도화 및 장척화에 힘입어 HTS-케이블의 실용화를 목표로 경제성이 있는 전력케이블을 개발하려는 움직임뿐만 아니라 실증시험 등 활발한 연구가 진행 중이다. 그러나 초전도전력케이블에서 발생되는 교류손실은 케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가로 인한 기존 케이블과의 가격경쟁에서 경제성을 저하시키는 주된 요인으로 작용하기 때문에 이의 상용화에 앞서 교류손실에 대한 정확한 규명이 되어야 하며 또한 실계통 투입 시 중요한 선로임피던스에 대한 정확한 규명도 필요하다. 본 논문에서는 실제 한전 주관으로 고창시험장에 설치된 배전급 22.9 kV, 100 m, 50 MVA급 3 상 HTS-케이블에 대한 통전특성을 규명하기 위하여 먼저 HTS-케이블의 DC 통전특성을 조사하였다. 또한 3상평형운전상태에서 AC 통전특성(인덕턴스 및 교류손실)을 실험적으로 조사하였으며 5m-케이블에서 측정된 결과와 비교 검토하였다.

  • PDF

Development of Optical Video Device for HD-SDI Video Signal Transmission (HD-SDI 비디오 신호 전송을 위한 광 비디오 전송 장치 개발)

  • Lee, Dong-Real
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.6
    • /
    • pp.245-250
    • /
    • 2015
  • We have developed an optical video transmission device for HD-SDI signal transmission. The optical transmitter/receiver unit operates at DC 5 volt and small enough to be attaced near surveillance camera. They have internal voltage regulating circuits to supply 3.3V to other circuits inside the unit. The optical transmitter is composed of cable driver, laser diode driver, and laser diode. The optical receiver is composed of photodiode, limiting amp, and cable equalizer. The wavelength of the trasmitter was 1.3 um, and optical power was -5dBm, and the speed was 1.485Gbps. The receiver sensitivity was -23 dBm. We confirmed that the optical device can transmit HD-SDI video through 30 km optical fiber without any interruption.

The Signal Distortion Due to the Electromagnetic Induction Inside a Cable (전선의 전자기유도 현상에 의한 신호 왜곡)

  • Jeong Ji-Min;Choi Seong-Jun;Kim Jung-Ho;Song Young-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.4
    • /
    • pp.251-255
    • /
    • 2004
  • Electric cables such as multi-interphone cables and ribbon cab]os are commonly used for data aquisition in the DC resistivity survey. In general, electromagnetic induction may occur in the electric cables when electric current flows through them. In case of using multi-interphone cables in the DC resistivity survey, electromagnetic induction could take place due to the entangled wires of the multi-interphone cables, when the current flows through them. Then, the electromagnetic induction may cause measured DC resistivity data to be distorted. In this study, a monitoring system with PXI (PCI Extention for Instrumentation) was constructed to examine signal distortion on the DC resistivity data, attributed to the electromagnetic induction. Common electric cables used in the DC resistivity survey were tested to observe the waveforms of the electric voltages. The waveforms measured were compared to examine signal distortion due to the electromagnetic induction. The results may provide information on the resistivity data obtained using different electric cables in the DC resistivity survey. The distortion of waveforms attributed to the electromagnetic induction wat not observed when using ribbon cables for DC resistivity data aquisition, while the distortion were observed when using multi-interphone. Therefore, the ribbon cables provide better quality of data than other cables in the DC resistivity data aquisition.

Residual magnetic field profiles and their current density profiles of coated conductors for fast and slow cut-off current operations

  • Sun, J.;Tallouli, M.;Shyshkin, O.;Hamabe, M.;Watanabe, H.;Chikumoto, N.;Yamaguchi, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.17-20
    • /
    • 2015
  • Coated conductor is an important candidate for power cable applications due to its high current density. Even for DC power cable transmission, we must study the transport properties of HTS tapes after slow and fast discharge. In order to evaluate relation of the magnetic field with applied current we developed a scanning magnetic field measurements system by employing a Hall probe. This work presents the measurements of the magnetic fields above a coated conductor by varying applied current pattern. In the work, a transport current of 100 A, less than the critical current, is applied to YBCO coated conductor. We measured the residual magnetic field distributions after cut off the transport current with slow and fast operations. The results show differences of the magnetic field profiles and the corresponding current profiles by an inverse solution from the magnetic field measurement between these two operations because of the hysteresis of coated conductor excited by the transport current.

Design and Quench Characteristics of a 6 kJ SMES Coil (6 kJ SMES 코일의 설계 및 퀜치특성)

  • Ryu, K.;Kim, H.J.;Seong, K.C.;Lee, E.Y.;Cho, J.W.;Jin, H.B.;Ryu, K.S.;Choi, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.104-106
    • /
    • 1998
  • For the development of the 0.7 MJ small-sized superconducting magnetic energy storage (${\mu}$SMES) device, quench currents of a kA class superconducting cable were tested for various winding tensions because a dry superconducting coil is usually quenched by an abrupt heat pulse due to strand motions. The test coil similar to parameters of the optimally designed 0.7 MJ ${\mu}$SMES except a stored energy and a size was fabricated based on the test results of the kA class superconducting cable and tested. These experimental results show that the highly prestressed test coil has an excellent DC performance in spite of a dry type coil but its quench current is much degraded even at the low field ramping rate of about 0.4 T/s.

  • PDF

Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment (완화전류 측정에 의한 지중배전케이블의 열화진단)

  • Kim, Ju-Yong;Song, Il-Keun;Kim, Dong-Myung;Yun, Tae-Sang;Jeong, Sang-Bong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

Risk Assessment of Energy Storage System using Event Tree Analysis (ETA를 이용한 에너지저장시스템의 위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Eui-Sik;Park, Young-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.34-41
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on six items of ESS: the whole system, battery, BMS, PCS, ESS and cable. To achieve that, ESS work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew initiation events (IE) and end states (ES). ETA is applied to the main functions of each item, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events ; loss of grid electricity of ESS, loss of battery electricity(DC) of battery, impairment of electric function of BMS, loss of grid electricity(AC) of PCS, loss of data of EMS, Mechanical damage of cable, event sequence analysis conducted on the basis of event trees. If the suggested IEs and ESs are applied on the basis of ESS event cases, it is expected to prevent the same kinds of accident and operate ESS safely.