The Study of Transient Coupling between AC and DC lines on the Same Transmission Tower (AC 및 DC 송전선로 과도상태 커플링 영향 분석)

  • Yoon, Jong-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.14-19
    • /
    • 2011
  • The implemetation of the AC and DC lines on the same transmission tower is an economical and practical approaching that increase the power transmission capacity of an existing transmission corridor. But, In this case, Inductive and capacitive coupling between AC and DC lines on the same tower should be investigated in advance. According to the installation plan of ${\pm}80kV$ 60MW bipole HVDC in Jeju island, KOREA that will be commissioned until 2011, DC lines will parallely operate with 154kV 2 AC lines in existed 154kV AC 4 lines transmission tower. This paper presents the transient analysis results about the interaction between 154kV AC and 80kV DC lines in the same transmission tower.

A novel robust MMC HVDC topology in dc line fault (DC 지락 사고에 강인한 MMC HVDC의 새로운 토폴로지)

  • Jung, Hong-Ju;Kim, Si-Hwan;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.514-515
    • /
    • 2013
  • 본 논문은 해상풍력단지와 같은 대용량 신재생에너지를 송전하는데 적합한 전압형 HVDC(High Voltage DC) 중에서, 최근 실용화되어 많은 연구가 이루어지고 있는 Modular Multi-level Converter HVDC(MMC HVDC)에 대한 새로운 토폴로지를 제안한 내용이다. 대표적인 MMC HVDC는 독일의 R. Marquardt 교수가 제안한 Half-Bridge 모듈을 적용하여 MMC를 구현하는 방식으로 이는 계통에 DC 지락 사고가 발생할 경우 컨버터를 구성하는 모듈에 큰 고장 전류가 흐르게 되고 결국 모듈의 주요 구성품인 IGBT가 소손 될 수 있는 약점을 지니고 있다. 이를 보완하기 위해 각 모듈에 Thyristor를 삽입하거나 새로운 모듈을 적용하는 방식이 제안되었다. 본 논문에서는 DC 지락 고장시 큰 고장 전류를 차단할 수 있는 새로운 모듈 구성을 제안하였다. 또한 제안된 토폴로지에 대한 기본 동작을 설명하고 시뮬레이션을 통해 제안한 방식과 기존의 방식을 비교 분석 하였다.

  • PDF

Advanced Distance Relaying of on a Double Circuit Transmission Line (병행 2회선 송전선로의 개선된 거리계전기법)

  • Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.23-31
    • /
    • 2015
  • This paper proposes an advanced distance relaying based on the DC offset removal filter to minimize the effects of DC offset on a double circuit transmission line. The proposed DC offset removal filter uses only one cycle of data for phasor extraction computation, which does not need to preset the time constant of the DC offset component. This proposed distance relaying uses not only the residual current of the faulted circuit but also mutual current of the healthy adjacent circuit. A series of off-line test results using ATP simulation data show the effectiveness of the an advanced distance relaying.

Study on Dip Variation of STACIR/AW Conductor Using DC Current Facility (STACIR/AW전선의 대전류설비에 의한 실증적 이도특성에 관한 고찰)

  • Shin, Koo-Yong;Lee, Seong-Doo;Min, Byung-Uk;Wi, Hwa-Bok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.566-568
    • /
    • 2005
  • STACIR/AW은 최근 사용이 증가되고 있는 증용량전선으로 기존 송전선에 비해 많은 전류를 송전하면서도 이도특성이 우수한 장점을 가지고 있다. 이 논문에서는 STACIR/AW 전선의 온도 및 대전류특성에 대한 실증시험을 위하여 구축된 송전선로용 3[kA]급 대전류 발생 장치를 이용해 345kV 송전선로의 표준경간인 350m 시험선로에 $480\;mm^2$$410\;mm^2$ 전선을 가선하여 전류 특성 시험을 수행하였다. 본 논문에서는 최대 허용전류에 대한 단계별 이도특성을 외기 조건과 전선의 장력 변화를 고려하여 고찰하여 국내 주요 전선사의 증용량전선에 대한 신뢰성을 검증하고, 또한 계절별 특성시험 및 환경시험 챔버를 이용한 참고시험과 기본적 동적해석을 통하여 외기 조건에 전선의 최대허용전류를 검토하였다. 또한 실선로에 적용된 $480\;mm^2$$410\;mm^2$ 의 증용량 전선에 최대 부하율을 파악하고 동일 조건에 부하전류를 인가한 실증시험을 통하여 전선의 이도증가율을 분석하여 상용선로의 운전조건을 검토하였다.

  • PDF

Enhanced Fault Location Algorithm for Short Faults of Transmission Line (1회선 송전선로 단락사고의 개선된 고장점 표정기법)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.955-961
    • /
    • 2016
  • Fault location estimation is an important element for rapid recovery of power system when fault occur in transmission line. In order to calculate line impedance, most of fault location algorithm uses by measuring relaying waveform using DFT. So if there is a calculation error due to the influence of phasor by DC offset component, due to large vibration by line impedance computation, abnormal and non-operation of fault locator can be issue. It is very important to implement the robust fault location algorithm that is not affected by DC offset component. This paper describes an enhanced fault location algorithm based on the DC offset elimination filter to minimize the effects of DC offset on a long transmission line. The proposed DC offset elimination filter has not need any erstwhile information. The phase angle delay of the proposed DC offset filter did not occurred and the gain error was not found. The enhanced fault location algorithm uses DFT filter as well as the proposed DC offset filter. The behavior of the proposed fault location algorithm using off-line simulation has been verified by data about several fault conditions generated by the ATP simulation program.

DC-OPF Algorithm using Relative-Contribution Index in Generators (송전선에 흐르는 전력조류의 발전기별 상대 기여도를 이용한 DC-OPF 알고리듬)

  • Bang, Young-Sun;Ko, Dong-Wook;Chun, Yeong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.390-391
    • /
    • 2006
  • The economic dispatch problem is important in both power system planning and operation, although there have been major advances in defining and solving more complete Optimal Power Flow(OPF) problems, there exists a need for constrained economic dispatch techniques which, though not as rigorous or as exact an OPF, are fast enough to be used on desktop computers. This paper presents a DC-OPF algorithm that is based upon Relative-Contribution Index in Generators. The transmission constraints are modeled as linear constraint based on a DC-Power-Flow model. An detailed illustrative example is presented.

  • PDF

A Study on the Design of DC Circuit Breaker with Transformer (변압기결합형 DC 차단기 설계에 관한 연구)

  • Park, Seong-Mi;Lee, Sang-Hun;Na, Jeong-Sueng;Chung, Dae-Won;Yang, Seung-Hak;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.471-472
    • /
    • 2017
  • DC 전력전송은 송전선로의 원거리화 및 절연내력의 저감과 같은 장점이 있으나, 전류 차단 시 큰 아크로 인하여 고속 차단기 구성이 어렵다는 큰 단점이 있다. 최근 소용량 DC 전력전송에 있어서 큰 과제인 고속차단을 위해 전자식 차단기에 대한 연구가 이루어지고 있다. 본 연구에서는 변압기와 결합한 SCR을 이용한 새로운 전자식 차단기를 제안한다. 제안된 방식은 SCR 오프시 변압기를 이용하여 SCR에 역전압을 인가하므로 전류를 소호하는 방식이다. 또한 Psim을 이용한 시뮬레이션을 통하여 제안된 방식의 타당성 검증하였다.

  • PDF

Study on SCR Type High Speed DC Circuit Breaker Using Bus Voltage (모선 전압을 이용한 SCR Type 고속 DC 차단기 연구)

  • Ju, Hong-Ju;Kim, Soo-Yeon;Kang, Seong-Yong;Kim, Kuk-Hyeon;Park, Seong-Mi;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.325-326
    • /
    • 2017
  • 태양광 발전의 DC 전압 출력 및 케이블을 이용한 해상풍력 발전과 같은 신재생 에너지 이용이 증대되고 있다. 또한, 에너지의 전력전송 대용량화에 따른 기존의 AC 전력전송 방식을 개선한 DC 전력전송에 대한 연구가 활발히 연구되고 있다. DC 전력전송은 송전선로의 원거리화 및 절연내력의 저감과 같은 장점이 있으나, 전류 차단 시 큰 아크로 인하여 고속차단기 구성이 매우 어렵다는 단점이 있다. 최근에는 DC 전력전송에 있어서 큰 과제인 고속차단을 위해 전자식 차단기에 대한 연구가 이루어지고 있다. 이러한 전자식 차단기를 구성할 경우 차단기 투입 시 큰 돌입전류와 입출력 절연저항이 기존 차단기보다 낮아지는 단점으로 인해 매우 큰 아크가 발생한다. 본 논문에서는 고 전압 대 전류에 적합하고 피크성 전압/전류에 강인한 소자인 SCR을 이용한 전자식 DC 차단기 연구를 진행하였다.

  • PDF

Comparison of DC/AC breakdown characteristics of polymer sheets for polymer insulator (실리콘 베이스와 첨가제 함량에 따른 폴리머애자용 고분자의 DC/AC 절연파괴 특성 연구)

  • Seong, Jae-Kyu;Seo, In-Jin;Park, Tae-Gun;Shin, Woo-Ju;Oh, Seok-Ho;Khan, Umer Amir.;Hwang, Jae-Sang;Lee, Bang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1592-1593
    • /
    • 2011
  • 전 세계적으로 전력사용량의 증가와 전력기술이 발전함에 따라 절연소재 또한 급속한 발전을 가져왔다. 특히 폴리머 애자는 경량성, 내오염성, 시공의 용이성 등과 같은 장점으로 오랫동안 사용해온 자기 애자를 대체하여 사용되고 있다. 최근 고효율 장거리 전력 송전이 가능한 HVDC 송전선로가 증가함에 따라 직류 절연물에 대한 연구가 활발히 이루어지고 있다. 본 연구에서는 두 종류의 실리콘 베이스와 첨가제 함량을 변화시킨 폴리머 시편의 직류 파괴전압 실험과 교류 파괴전압 실험을 실시하였다. 취득한 데이터를 Weibull 분포를 통해 분석 한 결과 직류 파괴전압이 교류 파괴전압에 비해 2~5배 높은 것으로 나타났다.

  • PDF

New Control Method of Converter to Improve Transient Response in HVDC Link System (직류송전에서 과도응답특성 개선을 위한 컨버터의 제어)

  • Min, Wan-Ki;Yoo, Myeong-Ho;Kim, Yeong-Han;Choi, Jeo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.342-344
    • /
    • 1996
  • This paper describes the usefulness of new control method in HVDC link system which suffers from severe condition of weak ac system. The proposed control scheme is used for the positive feedback control which directly controlls dc current at dc link system. The object of this paper is to improve the transient response of HVDC link system in disturbances such as faults. To achieve this objective, digital time-domain simulations are employed by the Electro Magnetic Transient Program for DC system(EMTDC).

  • PDF