• Title/Summary/Keyword: DC(direct current)

Search Result 435, Processing Time 0.033 seconds

The Development of System for Measuring Ion Generated from HVDC Overhead Transmission Line (초고압 직류 가공 송전선로에서 발생되는 이온 계측시스템 개발)

  • Ju, Mun-No;Yang, Kwang-Ho;Lee, Dong-Il;Shin, Koo-Yong;Lim, Jae-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2035-2040
    • /
    • 2008
  • The electrical discharge of high voltage direct current(HVDC) overhead transmission line generate audible noise, radio noise, electric field, ion current and induced voltage on the ground. These items are major factors to design environmentally friendly configuration of DC transmission line. Therefore, HVDC transmission lines must be designed to keep all these corona effects within acceptable levels. Several techniques have been used to assess interference caused by ions on HVDC overhead transmission line. In this study, to assess the ion characteristic of DC line, the ion current density and induced voltage caused by ion flow were measured by plate electrodes manufactured from a metal flat board and charged bodies, respectively. The charged body has two types of cylinder and cylindrical plate. From the results of calibration experiments, the sensitivity of flat electrode and charged body can be obtained. At present, the developed system is used to investigate the ion generation characteristics of Kochang DC ${\pm}500kV$ test line.

Optimal Power Flow of DC-Grid Based on Improved PSO Algorithm

  • Liu, Xianzheng;Wang, Xingcheng;Wen, Jialiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1586-1592
    • /
    • 2017
  • Voltage sourced converter (VSC) based direct-current (DC) grid has the ability to control power flow flexibly and securely, thus it has become one of the most valid approaches in aspect of large-scale renewable power generation, oceanic island power supply and new urban grid construction. To solve the optimal power flow (OPF) problem in DC grid, an adaptive particle swarm optimization (PSO) algorithm based on fuzzy control theory is proposed in this paper, and the optimal operation considering both power loss and voltage quality is realized. Firstly, the fuzzy membership curve is used to transform two objectives into one, the fitness value of latest step is introduced as input of fuzzy controller to adjust the controlling parameters of PSO dynamically. The proposed strategy was applied in solving the power flow issue in six terminals DC grid model, and corresponding results are presented to verify the effectiveness and feasibility of proposed algorithm.

Commutation Modeling and Characteristic Analysis of DC Motor using Circuit Parameters (회로정수를 이용한 직류전동기의 정류회로 모델링 및 특성 해석)

  • Kim, Young Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.57-62
    • /
    • 2013
  • Because of high torque and easiness of speed control, Direct Current(DC) motors have been used for a long time. But, its applications are limited in circumstance and performance, since they contained brush and commutator. The commutation characteristic gives effect to life and performance of the DC motor. Naturally, the commutation characteristic analysis is strongly required. In this paper, With the result of finite element analysis, The inductance is calculated each rotor position and applied to the voltage equations coupled with commutation equation. Also, contact resistances of brush/commutator assembly are considered using contact area and brush width converted with commutator segments. The time derivative term in the differential equation is solved in time difference method. This algorithm was applied to 2-pole shunt DC motor. We considered commutation characteristic by changing contact resistance between brush and commutator segment.

A Study on Current Control of Dual Active Bridges Using Virtual Direct Power Control (가상 직접 전력 제어를 이용한 듀얼 액티브 브리지의 전류 제어에 대한 연구)

  • Kang, Ja-Yoon;Lee, Sang-Taek;Shin, Duck-Shick
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.463-464
    • /
    • 2020
  • 전세계적으로 신재생에너지 연구가 개발되면서 DC 마이크로 그리드가 빠르게 확산되고 있다. DC 마이크로 그리드에는 ESS가 필수적으로 적용되는데, ESS 충방전을 위해 양방향 및 절연 기능이 포함한 토폴로지가 적용되어야 한다. 최근에는 절연형 양방향 컨버터로 듀얼 액티브 브리지 토폴로지가 제어에 대한 연구와 함께 많이 적용되어지고 있다. DC 마이크로 그리드에는 여러 DC-DC 컨버터로 구성되어 있어 상위 제어기에서 전류지령 값을 통해 전류제어로 운영된다. 본 논문에서는 가상 직접 전력 제어를 이용하여 빠른 응답을 구현하는 전류제어를 제안하였다. 검증 방법으로는 시뮬레이션을 통해 검증 하였다.

  • PDF

Low-Cost SVM-DTC Strategy of Induction Machine Drives Using Single DC-link Current Sensor

  • Wang, Wei;Cheng, Ming;Hua, Wei;Ding, Shichuan;Zhu, Ying;Zhao, Wenxiang
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In conventional direct torque control (DTC) using space-vector modulation (SVM) of induction machine (IM) drives, at least three current sensors are needed. In this paper, a low-cost SVM-DTC strategy is proposed, in which only a single current sensor is used. The position of the voltage space vector is divided into two areas: effective and non-effective area. If it is located in the non-effective area, the voltage space vector will be shifted into the effective area with minimum distortion. Further, the switching frequency remains constant. The simulation is carried out on a MATLAB/Simulink platform and the simulated results verify the effectiveness of the proposed strategy.

Reduced Switch Count Topology of Current Flow Control Apparatus for MTDC Grids

  • Diab, Hatem Yassin;Marei, Mostafa Ibrahim;Tennakoon, Sarath B.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1743-1751
    • /
    • 2016
  • The increasing demand for high voltage DC grids resulting from the continuous installation of offshore wind farms in the North Sea has led to the concept of multi-terminal direct current (MTDC) grids, which face some challenges. Power (current) flow control is a challenge that must be addressed to realize a reliable operation of MTDC grids. This paper presents a reduced switch count topology of a current flow controller (CFC) for power flow and current limiting applications in MTDC grids. A simple control system based on hysteresis band current control is proposed for the CFC. The theory of operation and control of the CFC are demonstrated. The key features of the proposed controller, including cable current balancing, cable current limiting, and current nulling, are illustrated. An MTDC grid is simulated using MATLAB/SIMULINK software to evaluate the steady state and dynamic performance of the proposed CFC topology. Furthermore, a low power prototype is built for a CFC to experimentally validate its performance using rapid control prototyping. Simulation and experimental studies indicate the fast dynamic response and precise results of the proposed topology. Furthermore, the proposed controller offers a real solution for power flow challenges in MTDC grids.

Treatment of Heavy Metals and Phenol in Contaminated Soil Using Direct Current and Pulse Voltage (직류 전원과 펄스 전원을 이용하여 오염된 토양에서의 중금속과 페놀 처리)

  • Choi, Changsik;Hong, Bumeui;Choi, Hee Young;Lee, Eunsil;Choi, Suk Soon
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.606-611
    • /
    • 2016
  • In this work, the treatment of heavy metals and phenol in the contaminated soil was investigated by applying direct current (DC) and pulse voltage. When the DC was used, the removal efficiencies for Cu, Zn, As, and Pb were 73, 88, 10, and 10%, respectively, and more than 95% for phenol was removed. Furthermore, when a pulse voltage was employed the removal efficiencies for Cu, Zn, As, and Pb were 88, 92, 40, and 40%, respectively, and 87% of phenol was removed. The results indicate that the application of a pulse voltage for the treatment of contaminated soil reduced electro-osmosis, but increased the rate of electric current movement of heavy metals. In addition, the removal efficiencies for As and Pb have been improved due to the enhanced adsorption capacity of clay components in the soil. Therefore, these experimental results could be effectively applied in remediation technology for the treatment of various heavy metals and phenol.

Study on the effect of DC voltage in oil-immersed transformer insulation system (DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구)

  • Jang, Hyo-Jae;Kim, Yong-Han;Seok, Bok-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

The Problems in the Measurement of DC Potential on Meridian Skin Area (경락노선상 직류 전위 측정에서의 문제점)

  • Heo, Ik-Beom;Lee, Woo-Cheol;Lee, Yoo-Jeong;Yin, Chang-Shik
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.9 no.1
    • /
    • pp.131-135
    • /
    • 2005
  • Background and purpose: The measurement of direct current (DC) potential on skin area of meridian has recently been adopted to explore the electrophysiological characteristics of meridian system, But there exists two problems to be explained; the entity of the DC potential to be measured and the characteristics of electrode gel interface of measurement system, It is not clear whether the DC potential reflect, at least hypothetically, the entity of meridian, and if there exist any unstable factor in the DC potential measurement system. Methods: In this study, we designed an electronic circuit model of skin and applied known DC potential sources $({\pm}10.75mV,\;0mV)$ to the electrode interface of the skin model. Results: The result showed that the measured DC potential changed according to the time, and the same phenomenon was observed when the electrode gel was replaced with an electric condenser. It is suggested that the measurement of DC potential on electrode gel interface is very difficult and produces unstable values due to the capacity effect of electrode gel. Conclusion: Further studies on the DC potential evaluation in the context of meridian study should consider and bypass this problem.

  • PDF

Complementary Power Control of the Bipolar-type Low Voltage DC Distribution System

  • Byeon, Gilsung;Hwang, Chul-Sang;Jeon, Jin-Hong;Kim, Seul-Ki;Kim, Jong-Yul;Kim, Kisuk;Ko, Bokyung;Kim, Eung-Sang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.786-794
    • /
    • 2015
  • In this paper, a new power control strategy for the bipolar-type low voltage direct current (LVDC) distribution system is being proposed. The dc distribution system is considered as an innovative system according to the increase of dc loads and dc output type distribution energy resources (DERs) such as photovoltaic (PV) systems and energy storage systems (ESS). Since the dc distribution system has many advantages such as feasible connection of DERs, reduction of conversion losses between dc output sources and loads, no reactive power issues, it is very suitable solution for new type buildings and residences interfaced with DERs and ESSs. In the bipolar-type, if it has each grid-interfaced converter, both sides (upper, lower-side) can be operated individually or collectively. A complementary power control strategy using two ESSs in both sides for effective and reliable operation is proposed in this paper. Detailed power control methods of the host controller and local controllers are described. To verify the performances of the proposed control strategy, simulation analysis using PSCAD/EMTDC is being performed where the results show that the proposed strategy provides efficient operations and can be applied to the bipolar-type dc distribution system.