• Title/Summary/Keyword: DAQ(Data Acquisition)

Search Result 62, Processing Time 0.024 seconds

Development of Mobile System for Field Data Acquisition based on CompactFlash Card (CompactFlash 카드 기반의 필드 데이터 수집을 위한 모바일 시스템의 개발)

  • Seo, Jung-Hee;Park, Hung-Bog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1693-1700
    • /
    • 2010
  • Field data acquisition is faster in PDA-based mobile environment compared with document-based data acquisition, ensuring accurate data acquisition. However, portable DAQ systems of mobile environment can effectively replace DAQ systems embedded in computers but are less capable than DAQ systems embedded in computers and usually used in environments different from computers, causing noises whose cause are characteristics not certainly known. Therefore, in order to collect mobile-based field data, CompactFlash card-based hardware prototypes are suggested and mobile applications which guarantee acquisition of large amount of data with low hardware capability are performed. According to the test, mobile environments such as PDA were proved to be an effective way of collecting large amount of data. However, hardware performance has major effects on sequential data acquisition in mobile environments regardless of data display.

Real -Time ECG Signal Acquisition and Processing Using LabVIEW

  • Sharma, Akshay Kumar;Kim, Kyung Ki
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.162-171
    • /
    • 2020
  • The incidences of cardiovascular diseases are rapidly increasing worldwide. The electrocardiogram (ECG) is a test to detect and monitor heart issues via electric signals in the heart. Presently, detecting heart disease in real time is not only possible but also easy using the myDAQ data acquisition device and LabVIEW. Hence, this paper proposes a system that can acquire ECG signals in real time, as well as detect heart abnormalities, and through light-emitting diodes (LEDs) it can simultaneously reveal whether a particular waveform is in range or otherwise. The main hardware components used in the system are the myDAQ device, Vernier adapter, and ECG sensor, which are connected to ECG monitoring electrodes for data acquisition from the human body, while further processing is accomplished using the LabVIEW software. In the Results section, the proposed system is compared with some other studies based on the features detected. This system is tested on 10 randomly selected people, and the results are presented in the Simulation Results section.

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

Development of a Rapid Control Prototyping System Based on Matlab and USB DAQ boards (Matlab과 USB DAQ 장치를 이용한 Rapid Control Prototyping System 개발)

  • Lee, Young-Sam;Yang, Ji-Hyuk;Kim, Seuk-Yun;Kim, Won-Sik;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.10
    • /
    • pp.912-920
    • /
    • 2012
  • In this paper, we propose a new and cost-effective RCP (Rapid Control Prototyping) system based on Matlab/Simulink and a DAQ (Data Acquisition) unit with the high speed USB communication interface. The proposed RCP system has a feature that a computer on which Simulink is running acts as a realtime controller and a DAQ unit performs data acquisition, transmission of the data to and from a computer, and the application of control data received from the computer. For its implementation, we develop 10 communication blocks each of which is constructed by using S-function. In order to increase the data communication speed and thus to reduce the sampling period of the overall control system, we propose to use a batch transfer strategy through the USB interface. The proposed RCP system has several advantages over existing methods such as good maintainability, portability due to the USB interface, low cost, and no necessity for C-code generation even though it can only be applied to control systems with moderate sampling rates. It is expected that the proposed RCP system can be useful in teaching control-related topics to undergraduate and graduate students.

Using Requirements Engineering to support Non-Functional Requirements Elicitation for DAQ System

  • Kim, Kyung-Sik;Lee, Seok-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.3
    • /
    • pp.99-109
    • /
    • 2021
  • In recent machine learning studies, in order to consider the quality and completeness of data, derivation of non-functional requirements for data has been proposed from the viewpoint of requirements engineering. In particular, requirements engineers have defined data requirements in machine learning. In this study, data requirements were derived at the data acquisition (DAQ) stage, where data is collected and stored before data preprocessing. Through this, it is possible to express the requirements of all data required in the existing DAQ system, the presence of tasks (functions) satisfying them, and the relationship between the requirements and functions. In addition, it is possible to elicit requirements and to define the relationship, so that a software design document can be produced, and a systematic approach and direction can be established in terms of software design and maintenance. This research using existing DAQ system cases, scenarios and use cases for requirements engineering approach are created, and data requirements for each case are extracted based on them, and the relationship between requirements, functions, and goals is illustrated through goal modeling. Through the research results, it was possible to extract the non-functional requirements of the system, especially the data requirements, from the DAQ system using requirements engineering.

Proposal for guided missile actuator device inspection using data acquisition device (데이터 수집 장치를 이용한 유도탄 구동장치 점검 제안)

  • Eui-Jae Jung;Tack-Keun Oh;Jung-Min Lee;Pil-joong Yoo
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.423-428
    • /
    • 2023
  • In the missile actuator system, the time and position of the wings of the drive device are very important factors in the initial maneuver of the missile, and therefore, the missile actuator device must be inspected while ensuring the accuracy and real-time of motion collection data of the actuator. In this study, the difference between the design and implementation method for checking the existing actuator device and the design implementation method of the actuator device through the DAQ(Data Acquisition) device is compared, and the difference in data collection amount and real-time data collection performance is compared and tested, and the data shown through actual tests are compared. is converted into a graph, the actuator waveform is compared and analyzed, and based on the analyzed data, DAQ device inspection configuration that guarantees real-time response speed and stability during inspection of existing actuators and DAQ devices is proposed.

Development of a Measurement System for High-Speed Spindle Displacement (고속 스핀들의 변위측정 시스템 개발)

  • Kim, H.G.;Chung, W.J.;Ju, J.H.;Cho, Y.D.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.8-13
    • /
    • 2008
  • At present many research projects on high-speed spindles are being conducted. These projects require a measurement technique which includes heat expansion, vibration and displacement measurement according to angular velocity. This paper presents the development of a measurement system for high-speed spindle displacement. The measurement system is based on $LabView^{(R)}$ and features the following sensors: optical sensor which reacts to the position of a marker on the spindle and enables two Laser Displacement Sensors(LDS). These Laser Displacement Sensors send their data to a DAQ(Data Acquisition Device). It is important that the delay time caused by the response times of the sensors as well as the sampling rate of the DAQ is considered because the spindle revolves at very high speeds.

The Design of Biosignal Acquisition Board Using USB (USB를 이용한 생체 신호 계측용 데이터 수집보드의 설계)

  • Hwang, Eon-Ju;Park, Min-Je;Kim, Dong-Yeon;Yoo, Jae-Ha;Kim, Soo-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2008.04a
    • /
    • pp.135-136
    • /
    • 2008
  • 본 연구에서는 USB(Universal Serial Bus)통신과 전기적 절연을 이용하여 생체신호계측이 가능한 USB 데이터 수집(DAQ, Data acquisition)보드를 설계 및 구현한 것이다. 대부분의 데이터 수집보드는 전기적 절연이 되어 있지 않기 때문에 의용계측에 있어서 적합하지 않다. 보드를 평가하기 위해 설계한 USB DAQ 보드와 PC를 사용하여 사인파와 램프신호 그리고 생체신호중 하나인 ECG 신호를 측정하였다. 제안한 USB 데이터 수집보드는 AD변환부, 전기적 절연부, 전송부, 디지털 입 출력부 그리고 DC-DC변환기(DC DC Convertor)로 구성되었고, 최대 1KHz의 샘플링 주파수와 12비트 분해능과 8채널의 성능을 가진다.

  • PDF

Hand Tracking and Calibration Algorithm Using the EPIC Sensors (EPIC 센서를 이용한 Hand Tracking 및 Calibration 알고리즘)

  • Jo, Jung Jae;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.2 no.1
    • /
    • pp.27-30
    • /
    • 2013
  • In this paper, we research the hand tracking and calibration algorithm using the EPIC sensor. We analyze the characteristics of EPIC sensor to be more sensitive in the around E-filed, and then we implement the 2-dimensional axis-transformation using the difference of detected amplitude between EPIC sensors. In addition, we implement the calibration algorithm considering the characteristics of EPIC sensor, and then we apply the Kalman filter to efficiently track a target. Thus, we implement the environment of window applications for verification and analysis the implemented algorithm. In turn, we use the DAQ API to extract the analog data. The DAQ hardware has the function of measuring and generating an electrical signal. Moreover, we confirm the movement of mouse cursor by detecting the potential difference depending on the movement of the user's hands.

  • PDF