• Title/Summary/Keyword: D50

Search Result 9,729, Processing Time 0.039 seconds

An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls (중량벽체의 차음특성에 관한 실험적 연구)

  • 김선우;이태강;송민정
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

Comparison on Accommodative Response Changes in the Normal Group and Convergence Insufficiency (정상군과 폭주부족군에서 조절반응 변화량의 비교)

  • Kwak, Ho-Weon;Lee, Se-Hee;Kwak, Hyung-Bin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.79-85
    • /
    • 2014
  • Purpose: This study investigated accommodative changes by measuring accommodative response, appearing on the normal and convergence insufficiency Group, by using both eyes open-view auto-refractometer (Nvision-K5001, shin-nippon, Japan). Methods: It carried out objective and subjective refractions, targeting 74 college students (54 males and 20 females) aged between 19 and 29 ($21.59{\pm}2.53$), spherical equivalent OD $-2.28{\pm}2.03$ D, OS $-2.18{\pm}2.01$ D, by measuring accommodative responses at full correction and under correction with plus lens +0.25, +0.50, +0.75 arbitrarily added. Results: In the group of normal and convergence insufficiency, the shorter fixation distances were, the greater accommodative lags showed. The group of convergence insufficiency showed the lesser changes of accommodative response than those of normal. But we found that the convergence insufficiency group had a little larger accommodative amplitude in the total fixation distances. The full correction of convergence insufficiency group and the under correction (+0.50 D) of normal were alike in the accommodative responses. We have also investigated that the correlation between accommodative responses and fixation distances was decreased steeply at the excessive low vision correction. Conclusions: Under correction (+0.50 D) in a near distance is expected to avoid unnecessary accommodative responses, make eyes relaxed and comfortable.

Evaluation of Pressurized Water Diffusion in Water Treatment Process Using CFD (전산유체역학(CFD)를 활용한 정수공정에서 압력수 확산공정 진단)

  • Cho, Young-Man;Yoo, Soo-Jeon;Roh, Jae-Soon;Bin, Jae-Hoon;Choe, Kwang-Ju;Lee, Kwang-Ug;Lee, Gi-Bong;Lee, Jeong-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.359-367
    • /
    • 2011
  • The Process of Pressurized water diffusion is mixing process by pressurized water injection with coagulate and chlorine water in the water treatment system. The objectives of this research were to evaluate the mixing length and diameter of diffusion plate and distance from injection pipe for complete mixing by using computational fluid dynamics. From the results of CFD simulation, when diameter of injection pipe is 50 mm, 100 mm and injection pressure is $5kg/cm^2$ and the diameter of inlet pipe is 2,200 mm, the complete mixing length is 4D (D: Length as diameter of inlet pipe). When diameter of injection pipe is 50 mm, the diameter of the diffusion plate in o.1D and distance from injection pipe is 0.2D, the complete mixing length is 3D that is the most short mixing length. But when diameter of injection pipe is 100 mm and mutually related the diameter, distance of diffusion plate, the complete mixing length is 4D over. Therefore, as the diameter of inlet pipe is 2,200 mm, the injection pipe 50 mm is more efficient than 100 mm.

Design of Ohmic Contact RF MEMS Silicon Switch with High Isolation at High Frequencies (고주파에서 높은 신호 격리도를 갖는 접촉식 RF MEMS 스위치의 설계)

  • Lee, Yong-Seok;Jang, Yun-Ho;Kim, Jung-Mu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1509_1510
    • /
    • 2009
  • This paper presents the design and simulation results of ohmic contact RF MEMS silicon switch with a high isolation at high frequencies along with the position of a contact part, initial off-state and intermediate off-state including the state where a contact part is placed right over a signal line of coplanar waveguide (CPW). The ohmic contact part is connected with comb drives made of high resistivity single crystalline silicon. The released contact part is $30{\mu}m$ apart from the edge of signal line on the glass substrate along the lateral direction (x-direction) at initial off-state. The electrostatic force of the comb electrode creates the x-directional movement thus initial state is converted to the intermediate off-state. The initial off-state of the switch results in isolations of -31 dB, -24 dB and reflections of -0.45 dB, -0.67 dB at 50 GHz and 110 GHz, respectively. It shows the isolation degradation when the contact part moves right over the signal line of CPW like an initial off-state of a conventional MEMS switch. The isolations and reflections are -31 dB, -24 dB and -0.50 dB, -1.31 dB at 50 GHz and 110 GHz, respectively at the intermediate off-state.

  • PDF

Analysis on the Interference Effects between HAPS and NGSO Systems in the Feeder Link (HAPS와 NGSO 시스템간의 Feeder Link상의 간섭분석)

  • Kang, Young-Heung;Mun, Seung-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.4 no.2
    • /
    • pp.182-190
    • /
    • 2000
  • In this paper, interference effects between NGSO and HAPS in the feeder link have been simulated and analyzed by means of calculating excess time percent and duration below the ell protection ratio. As the results, in the case of HAPS interference into NGSO, it can be obtained that the lowest C/I values are 20.42dB in 50km and 12.73dB in 20km of HAPS altitudes, respectively. And in the case of NGSO interference into HAPS, it can be obtained that the lowest ell values are 13.94dB and 10.42dB respectively. HAPS system has more interference reception from other systems or effects more interference into other systems as its altitude is lower. Also, the lowest ell values are appeared at difference time with its altitude.

  • PDF

Analysis on the Interference Effects between HAPS and NGSO Systems in the Feeder Link (HAPS와 NGSO 시스템의 Feeder Link상의 간섭분석)

  • 문승영;김봉석;강영흥
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.34-38
    • /
    • 2000
  • In this paper, interference effects between NGSO and HAPS in the feeder link have been simulated and analyzed by means of calculating excess time percent and duration below the C/I protection ratio. As the results, in the case of HAPS interference into NGSO, it can be obtained that the lowest C/I values are 27.42dB in 50km and 12.73dB in 20Km of HAPS altitudes, respectively. And in the case of NGSO interference into HAPS, it can be obtained that the lowest C/I values are 13.94dB and 10.42dB respectively. HAPS system has more interference reception from other systems or effects more interference into other systems as its altitude is lower. Also, the lowest C/I values are appeared at difference time with its altitude.

  • PDF

Studies on Tolerance of Mice to X-rays (X-선에 대한 마우스의 내력)

  • 김정진
    • The Korean Journal of Zoology
    • /
    • v.6 no.2
    • /
    • pp.11-15
    • /
    • 1963
  • A total of 220 adult male mice (18-20g) of the S.M. strain were divided into ten experimental and control groups. The total-body X-ray irradiation doses used were 50 r, 100r, 200r, 400r, 600r, 800r, 1,000r, 1,200r, 1,400r, and1,600r. The respiratory arrest (mortality) caused by each irradiation doses were observed for 30 days. Relationships between irradiation doses and survival time and percentage of response were examined. From this experiment, a formula was obtained to express the relationship among three factors, which may be presented as follows : {{{{{{{{P= { 10} over { SQRT { 2 pi } } INT _{ - INF }^{ p'} e-{(p'-50)^2 } over {200 }dp···(a) p'=100 LEFT { t^0.3- LEFT ( { { 16.9965} over {D-60 } } RIGHT ) ^{ { 1} over {2.5 } } } / LEFT { LEFT ( { 26372.43} over {D-81.86 } RIGHT ) ^{ { 1} over {2.5 } } -( { { 16.9965} over {D-60 } } RIGHT ) ^{ { 1} over {2.5 } } ···(b) p= { (D-60) t^0.75-16.9965} over {0.2186 t^0.75 +263.55434 }····(c) }} {{{{P= { 10} over { SQRT { 2 pi } } INT _{ - INF }^{ p'} e-{(p'-50)^2 } over {200 }dp···(a) p'=100 LEFT { t^0.3- LEFT ( { { 16.9965} over {D-60 } } RIGHT ) ^{ { 1} over {2.5 } } } / LEFT { LEFT ( { 26372.43} over {D-81.86 } RIGHT ) ^{ { 1} over {2.5 } } -( { { 16.9965} over {D-60 } } RIGHT ) ^{ { 1} over {2.5 } } ···(b) p= { (D-60) t^0.75-16.9965} over {0.2186 t^0.75 +263.55434 }····(c)

  • PDF

A NOTE ON LPI DOMAINS

  • Hu, Kui;Wang, Fanggui;Chen, Hanlin
    • Bulletin of the Korean Mathematical Society
    • /
    • v.50 no.3
    • /
    • pp.719-725
    • /
    • 2013
  • A domain is called an LPI domain if every locally principal ideal is invertible. It is proved in this note that if D is a LPI domain, then D[X] is also an LPI domain. This fact gives a positive answer to an open question put forward by D. D. Anderson and M. Zafrullah.

Target Strength for the Mugil Cephalus , Pleuronichthys Cornutus and Hexagrammos Otarii (숭어 , 도다리 , 쥐노래미의 초음파 반사강도에 관한 연구)

  • Hwang, Du-Jin;Sin, Hyeong-Il;Lee, Dae-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.1
    • /
    • pp.34-44
    • /
    • 1990
  • This paper describe on the target strengths for the dorsal and the side aspects of swimbladdered fishes, Mullet Mugil cephalus, Flounder Pleuronichthys cornutus and Rock trout Hexagrammos otakii two frequencies of 50KHz and 200KHz in the experimental water tank in order to improve the biomass estimation by the scientific fish finder. The results obtained are as follows: 1. The average of maximum target strength normalized by squared total length in cm unit are almost ranging from -70.9 dB to -66.8 dB regardless of species or frequencies. 2. The average of maximum target strength normalized by two-thirds squared body weight in g unit are almost ranging from -57.1 dB to -54.1 dB regardless of species or frequencies. 3. In comparison with target strength for 50KHz and 200KHz the former is more strong than the latter.

  • PDF

Depigmenting Effects of Esculetin and Esculin Isolated from Fraxinus rhynchophyllaHance (물푸레나무로부터 분리된 Esculetin와 Esculin의 미백 효능)

  • Hong, Yong Deog;Nam, Mi Hee;Lee, Chang Suk;Shin, Song Seok;Park, Young Ho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.1
    • /
    • pp.89-94
    • /
    • 2014
  • Stem bark extracts of Fraxinus rhynchophylla Hance were found to contain two major bioactive components, esculetin and esculin. Esculetin substantially inhibited melanogenesis in B16F10 melanoma cells, with an $IC_{50}$ value of $2.8{\mu}M$, and reduced melanin synthesis in Melan-A cells. Moreover, esculetin suppressed melanin biosynthesis by inhibiting mushroom tyrosinase activity, with an $IC_{50}$ value of $40{\mu}M$. Taken together, these results suggest that esculetin could serve as an effective skin-lightening agent that inhibits melanin production by regulating the activity of melanogenic enzymes.