• Title/Summary/Keyword: D.I.Y.

Search Result 11,778, Processing Time 0.04 seconds

Creativity Strategy of 3-Dimensional Illustration -through Printed Media- (3-D 일러스트레이션의 표현 전략 -인쇄매체를 중심으로-)

  • 신용순
    • Archives of design research
    • /
    • v.13 no.2
    • /
    • pp.123-132
    • /
    • 2000
  • Illustration is the work that brings out objective analyzing nature and things in many direction. Its purpose is to deliver the theme in an effective manner to appeal to the proper audience. Especially for 3 dimensional illustration, it is really important because its creativity can be complicated. Also, 3-D illustration are comprised of many materials and skills, so it is vital that 30D illustration is scientific and practical. In the research I am selecting on illustration that can be used in publishing and advertisements. I intend to give a clear understanding of 3-D illustration to my audience. In order to do that I have suggested an illustration must be developed through creativity strategy. Also through suggesting the condition of effective illustration, I want to help to set systematic and practical strategy of 3-D illustration.

  • PDF

Inhibition of the Formation of Adducts Between Metabolites of Benzo(a)pyrene and DNA by Panaxydol in vivo and in vitro (Benzo(a)pyrene 대사물질들의 DNA에 대한 Adduct 형성 억제에 미치는 Parlalrydol의 효과)

  • 박진규;김신일
    • Journal of Ginseng Research
    • /
    • v.13 no.1
    • /
    • pp.42-48
    • /
    • 1989
  • The binding of bay region diol-epoxides of polycyclic aromatic hydrocarbons (PAHs) to target tissue DNA is thought to be essential for the initiation of cancer by these compounds. In this study we investigated the effect of polyacetylenes such as panaxynol and panaxydol on the formation of benzo(a)pyreno (BP)-metabolite-DNA adduct in the liver of ICR mice. Treatment of mice by i.p. administration of polyacetylenes produced a marked reduction in BP metabolite binding to DNA in vitro. Following i.v. administration of (3H)BP(300, ${\mu}$Ci/21 nmoles/0.1 nt DMSO) to mice, radioactivity was detected in the DNA of the liver in vivo. The result of tentative identification of the 4 peaks between the two standard markers for high pressure liquid chromatography showed that the peaks. I, II, III, and IV were BP-phenol oxide-DNA adduct (or BP-diol-epoxide-dCyt. adduct), (-) BP$.$diolepoxide I:dGuO adduct, (+) BP-diol-epoxide I: dGuo adduct, and BP-diol-epoxide II:dGuO adduct, respectively. The minor adduct, (-) BP-diol epoxide I: dGuo was reduced to 6971 of the amount of the control, while the major adduct, (+) BP-diolepoxide I: dGuO(peak II) which was produced from (-) BP-7, 8-diol was reduced to 78% of that of the control. The amount of the minor adduct, BP-diol-epoxide II:dGuo adduct(peak IV) which formed from (+) BP-7, 8-diol was 58% of the control. These results show that the panaxydol is more related to inhibition of the formation of the minor ad- ducts than of the major adducts, which were generally produced from ($\pm$) BP-7, 8-dihydro-dials.

  • PDF

The Substates with Mutants That Negatively Charged Aspartate in Position 172 Was Replaced with Positive Charge in Murine Inward Rectifier Potassium Channel (Murine Kir2.1)

  • So, I.;Ashmole, I.;Stanfield, P.R.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.5
    • /
    • pp.267-273
    • /
    • 2003
  • We have investigated the effect on inducing substate(s) of positively charged residues replaced in position 172 of the second transmembrane domain in murine inward rectifier potassium channels, formed by stable or transient transfection of Kir2.1 gene in MEL or CHO cells. Single channel recordings were obtained from either cell-attached patches or inside-out patches excised into solution containing 10 mM EDTA to rule out the effect of $Mg^{2+}$ on the channel gating. The substate(s) could be recorded with all mutants D172H, D172K and D172R. The unitary current-voltage (I-V) relation was not linear with D172H at $pH_i$ 6.3, whereas the unitary I-V relation was linear at $pH_i$ 8.0. The relative occupancy at $S_{LC}$ was increased from 0.018 at $pH_i$ 8.0 to 0.45 at $pH_i$ 5.5. In H-N dimer, that was increased from 0.016 at $pH_i$ 8.0 to 0.23 at $pH_i$ 5.5. The larger the size of the side chain or $pK_a$ with mutants (D172H, D172K and D172R), the more frequent the transitions between the fully open state and substate within an opening. The conductance of the substate also depended upon the pKa or the size of the side chain. The relative occupancy at substate $S_{LC}$ with monomer D172K (0.50) was less than that in K-H dimer (0.83). However, the relative occupancy at substate with D172R (0.79) was similar to that with R-N dimer (0.82). In the contrary to ROMK1, positive charge as well as negative charge in position 172 can induce the substate rather than block the pore in murine Kir2.1. The single channel properties of the mutant, that is, unitary I-V relation, the voltage dependence of the mean open time and relative occupancy of the substates and the increased latency to the first opening, explain the intrinsic gating observed in whole cell recordings.

Evaluation on Accuracy of Noise Measurement Applications for iPhone 4 and iPhone 3Gs (아이폰 4 및 아이폰 3Gs의 소음측정 애플리케이션에 대한 정확도 평가)

  • Ma, Hye Ran;Park, Doo Yong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.1
    • /
    • pp.24-28
    • /
    • 2013
  • This article evaluates the accuracy of noise measurements for 37 noise measurement applications for iPhone 4 and iPhone 3Gs. Noise levels were measured using simultaneously a precision sound level meter and iPhones installed noise measurement applications at the levels of 70 dB, 80 dB and 90 dB at 1,000 Hz. Measurement errors were estimated by subtracting two measurements between iPhone and sound level meter. It was found that measurement errors of 34 applications(89.2%) were greater than ${\pm}2$ dB which is the maximum allowable error range for the Type II sound level meter. It was only 4 applications that measurement errors lie within ${\pm}2$ dB error range. There was no significant differences among measurements with four iPhone 4s. However, there were significant differences between the measurements with iPhone 4 and iPhone 3Gs using the same application. It was due to the different hardware specifications such as microphone. Therefore, noise measurement applications, for example, which has to utilize hardware of the smartphone, should be programmed to identify hardware specifications and to adopt appropriate correction factors upon hardware specifications. In conclusion, it is necessary to check accuracy and validity before using the noise measurement applications for iPhones. Also, it was suggested that it should develop an evaluation guideline or protocol on accuracy testing for the measurement applications using a smartphone.

Studies on Hemicellulase System in Aspergillus niger ( I ) - Purification and reconstitution of D-xylanase - (Aspergillus niger의 Hemicellulase계 효소에 관한 연구-D-xylanase계 효소의 정제와 재조합)

  • Park, Yang-Do;Lee, Hee-Jong;Moon H. Han
    • Microbiology and Biotechnology Letters
    • /
    • v.11 no.1
    • /
    • pp.23-32
    • /
    • 1983
  • In the present study, two kinds of D-xylanases (1, 4-$\beta$-D-xylan xylanohydrolase (EC 3.2.1.8) were purified and characterized from crude extract of Aspergillus niger KG79. Xylanase I was most active at pH 5.0, whereas xylanse II at pH 4.0 Both enzymes demonstrated their maximum activity at 45$^{\circ}C$. They were relatively stable between pH 4.0 and 6.0 at 3$0^{\circ}C$ for 6 hours. Molecular weight of xylanse I and II were 12, 500 and 11, 500, respectively. Michaelis-Menten constants of xylanse I and II were 0.28% and 0.26% of xylan, respectively. Both enzymes could degrade commercial D-xylan to xylose, xylobiose, and xylotriose to the degree of about 10% of total reducing power. Xylanse I could, however, liberate arabinose from barley straw xylan in addition to xylose and xylooligasaccharides more rapidly than xylanase II. The degree of hydrolysis was about 25%. The reconstituted D-xylanase system with purified xylanases and $\beta$-xylosidase degraded commercial xylan and barley straw xylan to the degree of 28% and 54% respectively. The limit of hydrolysis by the enzymes was suggested to be resulted from the physical structure of the substrate.

  • PDF

Measuring Visual Fatigue of Glasses-free Interactive 3D System Under Various Viewing Conditions (다양한 시청환경에 따른 무안경식 interactive 3D 시스템의 시각피로도 측정)

  • Kim, Jung-Yul;Li, Hyung-Chul O.;Kim, ShinWoo
    • Journal of Broadcast Engineering
    • /
    • v.18 no.3
    • /
    • pp.425-434
    • /
    • 2013
  • Observers usually experience visual fatigue when they watch contents displayed on 3D display. There has been various research on visual fatigue incurred in stereoscopic displays that use 3D glasses, but relatively less studies have been done in the area of autostereoscopic displays. i3D system refers to interactive 3D system that makes it possible for users to interact with contents using their hands. Current research measured visual fatigue that users experience from i3D under various visual environments. We examined the effects of viewing distance, disparities and visual orientation on visual fatigue in i3D. The results indicated that visual fatigue decreased with longer distance and smaller disparity. Visual fatigue increased with angle when 3D fusion was unstable. In addition, there was an interaction effect between angle and distance in which visual fatigue increased with distance under stable 3D fusion but there was no difference in visual fatigue as a function of distance when 3D fusion was unstable. These results would be importantly used to develop autostereoscopic displays that minimize visual fatigue.

Study on Polarographic Reduction of p-Nitrobenzeneazoresorcinol in Dimethylsulfoxide (디메틸술폭시드용매 속에서 파라니트로벤젠아조레조르시놀의 폴라로그래피的 還元에 관한 硏究)

  • Chil Nam Choe;Ki Hyung Jo;Chu Hyun Choe
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.433-440
    • /
    • 1986
  • The direct current polarographic behavior of 4n-BAR in dimethylsulfoxide as an aprotic solvent have been investigated. The reduction of 4n-BAR in 0.05M sodium perchlorate solution proceeds along two one-electron steps to give the corresponding compound containing hydrazo groups, each reduction wave was considerably diffusion controlled and irreversible. By addition of acid HAc to 4n-BAR in DMSO solvent, the two reduction waves have coalesced into one in the condition M $\geq$ mole ratio, acid/reductant(M = 2), the slope of $log(i_d-i)(Mi_d/2-i)/i$/ vs. (-E) is irreversible along one-electron steps reduction waves.

  • PDF

Development of a 3D Roughness Measurement System of Rock Joint Using Laser Type Displacement Meter (레이저 변위계를 이용한 암석 절리면의 3차원 거칠기 측정기 개발)

  • 배기윤;이정인
    • Tunnel and Underground Space
    • /
    • v.12 no.4
    • /
    • pp.268-276
    • /
    • 2002
  • In this study, a 3D coordinate measurement system equipped with a laser displacement meter for digitizing rock joint surface was established and the digitized data were used to calculate several roughness parameters. The parameters used in this study were micro avenge inclination $angle(i_{ave})$, average slope of joint $asperity(SL_{ ave})$, root mean square of $i-angle(i_{rms})$, standard deviation of height(SDH), standard deviation of $i-angle(SD_i)$, roughness profile $index(R_P)$, and fractal dimension(D). The relationships between the roughness parameters based on the digitzation of the surface profile were analyzed. Since the measured value varied according to the degree of reflection and the variation of colors at the measuring point, rock joint surface was painted in white to minimize the influence of the surface conditions. The comparison of the measured values and roughness parameters before and after painting revealed the better consequence from measurement on the painted surfaces. Also, effect of measuring interval was studied. As measured interval was increased, roughness parameters were exponentially decreased. The incremental sequence of degree of decrease was $SDH\; i_{ave},\; i_{rms},\; SD_i,\;and\; R_ p-1$. As a result of comparison of parameters from pin-type measurement system and laser type measurement system, all value of parameters were higher when laser-type measurement system was used, except SDH.

Clinical Study on Two Patients Typed as Soyangin with Cold Hypersensitivity on Hands and Feet (소양인 처방을 활용한 수족랭증(手足冷症) 치험 2례)

  • Kim, Oh-Young;Kim, Dong-Hoon;Ryu, Su-Hyang;Park, Soo-Gon;Lee, Jang-Sik;Park, Hye-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1082-1086
    • /
    • 2010
  • This study reports two cases of patients with cold hypersensitivity on hands and feet who were typed as the Soyangin. Although the two patients were experiencing the same symptom of cold hypersensitivity on hands and feet, we diagnosed one as a Soyangin Kyel-Hyung syndrome(結胸證) and the other as a Mang-eum syndrome(亡陰證). So we prescribed them Medications for Soyangin. And we used D.I.T.I.(Digital Infrared Thermal Imaging) to prove the improvement for cold hypersensitivity on hands and feet. The temperature change of D.I.T.I. after treatment showed that the main symptom After treatment, their symptoms were improved and the patients' D.I.T.I results also showed their improvement.

Standardization of diagnosis of cold hypersensitivity of hands and feet by D.I.T.I.

  • Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.3 no.1
    • /
    • pp.15-19
    • /
    • 2004
  • Cold hypersensitivity means a condition feeling cold at a temperature when one should not feel so. Cold hypersensitivity has been diagnosed based on the patient's subjective complaints. But these days, cold hypersensitivity can be diagnosed by the help of D.I.T.I.(Digital Infrared Thermal Imaging) This study is designed to verify the validity of diagnosis of cold hypersensitivity by D.I.T.I. Thermographic findings of 100 outpatients who visited the Kangnam Korean Hospital, KyungHee University, Seoul, Korea, from June 2000 to November 2000 were analyzed. The experimental group consisted of 50 patients who complained cold hypersensitivity, and for the control group, 50 patients who did not complain cold hypersensitivity. For the diagnosis of cold hypersensitivity of the hands, thermographic measurements were performed on two pairs of areas(palm-upper arm and back of hand-upper arm). And for that of the feet, other two pairs of areas(anterior thigh-top of the feet and posterior thigh-heel). When the criterion for thermal deviation between the palm and the upper arm was appointed as higher than $0.3^{\circ}C$, the sensitivity was 94.0% and the specificity, 90.0%. And when the criterion for that between the anterior thigh and the top of feet was appointed higher than $2.0^{\circ}C$, the sensitivity was 94.0% and the specificity, 76.0%. Through this study, the diagnostic standard for cold hypersensitivity of hands and feet could be presented.

  • PDF