• Title/Summary/Keyword: D.I.Y.

Search Result 11,778, Processing Time 0.053 seconds

Dose Distribution and Characterization for Radiation Fields of Multileaf Collimateor System (방사선 입체조형치료용 다엽콜리메이터의 특성과 조직내 선량분포 측정)

  • Chu, Sung-Sil;Kim, Gwi-Eon
    • Radiation Oncology Journal
    • /
    • v.14 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Purpose : Multileaf collimator(MLC) is very suitable tool for conformal radio-therapy and commissioning measurements for a multileaf collimator installed on a dual energy accelerator with 6 and 10MV photons are required, For modeling the collimator with treament planning software, detailed dosimetric characterization of the multileaf collimator including the penumbra width, leaf transmission between leaf leakage and localization of the leaf ends and sides is an essential requirement. materials and Methods : Measurement of characteristic data of the MLC with 26 pair block leaves installed on CLINAC 2100C linear accelerator was performed. Low sensitive radiographic film(X-omatV) was used for the penumbra measurement and separate experiments using radiographic film and thermoluminescent dosimeters were performed to verify the dose distribution, Measured films were analized with a photodensitometer of WP700i scanner. Results : For 6 & 10 MV x-ray energies, approximately $2.0\%$ of photons incident on the multileaf collimator were transmitted and an additional $0.5\%$ leakage occurs between the leaves. Localizing the physical end of the leaves showed less than 1mm deviation from the $50\%$ decrement line and this difference is attributed to the curved shaped end on the leaves One side of a sin히e leaf corresponded to the $50\%$ decrement line, but the opposite face was aligned with a lower value. This difference is due to the tongue and groove used to decrease between leaf leakage. Alignment of the leaves to form a straight edge resulted larger penumbra at far position from isocenter as compare with divergent alloy blocks. When the MLC edge is stepped by sloping field, the isodose lines follow the leaf pattern and Produce scalloping isodose curves in tissue. The effective penumbra by 45 degree stepped MLC is about 10mm at 10cm depth for 6MV x-ray. The difference of effective penumbra in deep tissue between MLC and divergent alloy blocks is small (5mm). Conclusion : Using the characteristic data of MLC, the MLC has the clinlical acceptability and suitability for 3-D conformal radiotherapy except small field size.

  • PDF

Weed-Ecological Classification of the Collected Barnyardgrass [Echinochloa crus-galli(L.) Beauv.] in Korea - III. Intra-specific variation of collected barnyardgrass species and accessions to herbicides response (한국산(韓國産) 피(Echinochloa crus-galli (L.) Beauv.) 수집종(蒐集種)의 잡초생태학적(雜草生態學的) 분류(分類)에 관(關한) 연구(硏究) - 제(第)III보(報) 수집종(蒐集種) 피의 제초제(除草劑) 반응(反應)에 대(對)한 종내변이(種內變異))

  • Im, I.B.;Guh, J.O.;Lee, D.J.
    • Korean Journal of Weed Science
    • /
    • v.9 no.1
    • /
    • pp.16-27
    • /
    • 1989
  • The six barnyardgrass [Echinochloa oryzicola (vasing.) Vasing.] and seventeen barnyardgrass [Echinochloa crus-gadli (L.) Beauv.] accessions, which were collected national widely in 1986 and selected two times through 1987. To study different growth response due to herbicide, pyrazolate, bifenox, quinclorac, the experiment was conducted with herbicide agar culture without nutrients, 1. Albinistic discoloration due to pyrazolate was more sensitive in E, crus-galli than E. oryzicola and among barnyardgrass accessions, Kumi, Ichon-A, Ichon-B, Boun-B and Kwangju-B were rather susceptible than Gyongju, Ansong, Boun-A, Jongju-A and Kwangju-A. 2. Twisting and growth retardation due to bifenox was less sensitive in E. oryzicola with less intra-specific variations than in E. crus-galli. Among E. crus-galli accessions, Boun-B, Ansong, Ichon-A, Ichon-B, Wonju and Kwangju-B were particulary susceptible, and Jinyang, Jongju-B, Jongju-A, Daejon, Kurye and Kwangju-A were tolerant as much as E. oryzicola. 3. Growth retardation and withering to dead due to quinclorac was more sensitive in E. oryzicola with less intra-specific variations than in E. crus-galli. Among accessions of E. curs-galli, Boun-A, Iri, Jongju-A, Jongju-B, Kwangju-A and Kwangju-B were rather similar suseptible to E, oryzicola than kimhae, Gyongju, Kumi, Wonju, Ichon-A, Ichon-B and Ansong. 4. Most accession of E. oryzicola was tolerant to both pyrazolate and bifenox, while susceptible to quinclorac. Among other accessions of E. crus-galli, Kurye, Kimhae, and Daejon were tolerant to all experimented herbicides, and Iri, Jongju-A, Jongju-B, and Kwangju-A were only tolerant to both pyrazolate and bifenox, while Kumi, Wonju, Ichon-A, Ichon-B, Boun-B and Kwangju-B were only tolerant to quinclorac.

  • PDF

Triple Detector SPECT Imaging with $^{99m}Tc-DMSA$ in Adult Patients with Urinary Tract Infection (성인 요로 감염 환자에서 $^{99m}Tc-DMSA$ 삼중검출기 SPECT 영상의 유용성)

  • Ryu Jin-Sook;Bae, Won-Gyu;Moon Dae-Hyuk;Lee, Myung-Hae;Kim, Soon-Bae,;Park, Su-Kil;Park, Jung-Sik;Hong, Chang-Gi D.;Cho, Kyung-Sik
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.290-298
    • /
    • 1992
  • Although early diagnosis of urinary tract infection is important, the radiologic evaluation is still controversial because of the low sensitivity and the lack of cost-effectiveness. This study was carried out to evaluate the clinical utility of high resolution triple head $^{99m}Tc-DMSA$ SPECT imaging in urinary tract infection. We prospectively performed $^{99m}Tc-DMSA$ planar and SPECT imaging, ultrasound of kidney (US), intravenous pyelography (IVP) and voiding cystourethrography (VCU) in all 60 adult patients with UTI [26 with first episode of acute pyelonephritis (APN), 22 with recurrent APN, and 12 persistent asymptomatic pyuria] and 25 normal persons. To assess reversibility of the renal cortical defect (RCD), $^{99m}Tc-DMSA$ SPECT was repeated 1 to 8 months later in those patients with abnormal initial findings. Overall detection rate of $^{99m}Tc-DMSA$ SPECT imaging was 83% (50/60), but planar, US, IVP and VCU showed abnormal findings in 68%, 28%, 32% and 13%, respectively. 25 out of 27 patients with normal or single RCD were all normal in other radioligic studies. Only two patients showed vesicoureteral reflux (VUR) on VCU (grade I) and mild hydronephrosis on IVP. But, high proportion of those with multiple RCD showed abnormal findings on US (17/33), IVP (18/33), and VCU (7/33): 67% in any of these 3 studies. Especially, 3 out 7 patients with VUR showed multiple RCD on $^{99m}Tc-DMSA$ SPECT without any abnormality on IVP or US. 25 normal persons showed normal findings in all studies except one false positive finding on $^{99m}Tc-DMSA$ SPECT imaging. Follow-up $^{99m}Tc-DMSA$ SPECT was done in 28 patients (13 with single RCD, 15 with multiple RCD). All 13 patients with single RCD showed improvement. Those with multiple RCD presented improvement in 4, no change in 10, and aggravation in 1 on follow-up studies. With these results, we conclude: 1) $^{99m}Tc-DMSA$ SPECT imaging is superior to planar imaging, US, IVP or VCU in detection of renal lesion in urinary tract infection. $^{99m}Tc-DMSA$ SPECT is useful as a initial diagnostic tool in adult patients with urinary tract infection. 2) The multiple RCD on $^{99m}Tc-DMSA$ SPECT represent the high probability of irreversible tissue change and need of extensive urological work-up.

  • PDF

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward (고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구)

  • Ryu, Jae-Kwang;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.19-26
    • /
    • 2008
  • Purpose: In general, We discharged radioactive wastewater and sewages less than $8.1{\times}10^{-13}$ Ci/ml in a exclusive water-purifier tank. Our hospital operating three exclusive water-purifier tank for radioactive wastewater and sewages of 60 tons capacity respectively. In order to meet the criteria it need a enough decay more than 125 days per each exclusive tank. However, recently we fell into the serious situation that decay period was decreased remarkably, owing to the wastewater amount increased rapidly by enlarge the therapy ward. For that reason, in this article, I'd like to say the way that reducing of radioactive wastewater and sewages rationally. Materials and Methods: From January, 2006 to October, four hundred and two cases were analyzed. They were all hospitalized during 3 days and 2 nights. We calculated the average amount of water used (include toilet water used, shower water used, washstand water used, $\cdots$), each exclusive water-purifier tank's decay period, as well as try to search the increased factors about water-purifier tank inflow flux by re-analysis of the procedure of radioisotope therapy step by step. Results: We could increase each exclusive water-purifier tank's decay period from 84 days to 130 days through the improvement about following cause: (1) Improvement of conventional toilet stool for excessive water waste $\rightarrow$ Replacement of water saving style toilet stool (2) Prevention of unnecessary shower and wash (3) Stop the diuretics taking during hospitalization (4) Analysis of relationship between water intakes and residual dose of body (5) Education about outside toilet utilization before the administration (6) Changed each water-purifier tank's maximum level from85% to 90% Conclusion: The originality of our efforts are not only software but hardware performance improvements. Incidentally the side of software's are change of therapy procedures and protocols, the side of hardware's are replacement of water saving style toilet stool and change of each water-purifier tank's maximum level. Thus even if a long lapse of time, problem such as return to the former conditions may not happen. Besides, We expect that our trials become a new reasonable model in similar situation.

  • PDF

Antioxidant Activities of Stachys sieboldii MIQ Roots (초석잠(Stachys sieboldii MIQ) 뿌리 추출물의 항산화 활성 고찰)

  • 백홍석;나영수;김도한;이창한;류병호;송승구
    • Journal of Life Science
    • /
    • v.14 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • The root of Stnchys Sieboldif MIQ was extracted three times with methanol and extract was found to contain 3.02% of polyphenols and 1.97% of flavonoids. DPPH radical scavenging method, ferric thiocyanate method, and nitrite scavenging ability method were employed to investigate the constituents of the extract and to measure their activity on antioxidation. The fraction extracted by ethylacetate showed higher anti oxidation value than that of $\alpha-tocopherol$, butylated hydroxyanisole (BHA), and butylated hydroxytoluene (BHT) at the same concentration. UV-VIS spectral data of the extract by ethylacetate that was isolated on a silica gel column proved adsorption maxima in the range of 280∼330 nm. The fraction ES-RS that has $\lambda_{max}(nm)$ of band 1, 325nm and band II, 289nm exhibitd the strongest activity on antioxidation. ES-R5 fraction showed similar pattern to flavones by the analysis of UV-VIS spectral data.

Effect of Seeding Date and Fall Harvest Method on the Growth Charateristics , Forage Yield and Quality of Winter Rye (파종시기 및 가을 수확방법이 추파호밀의 생육특성 , 사초수량 및 사료가치에 미치는 영향)

  • 김종덕;김동암
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.14 no.3
    • /
    • pp.238-246
    • /
    • 1994
  • This experiment was carried out to determine the effects of seeding date and fall harvest method on the growth characteristics, forage yield and quality of winter rye(Seca1e cereale L.) at the forage experimental field, College of Agriculture and Life Sciences, SNU, Suweon from 5 September 1992 to 21 May 1993. The experiment was arranged in a split plot design with three replications. Main plots consisted of three harvests, no defoliation, cutting and grazing. Sub-plots consisted of seeding dates, early(5 September), mid(25 September) and late(l0 October). The results obtained are summari7d as follows; I . A 3-day difference in the first heading of rye was observed between no defoliation and fall grazing, while there was a 6day difference between early and late seeding dates. Therefore, the effect of seeding dates on the fist heading date of rye was larger than that of fall harvest methods. 2. CP content of rye with fall grazing was slightly higher averaged 16.5% compared with both fall cutting and no defoliated 1ye(15.6%). Mean CP content of rye at the early, mid and late seeding dates was 14.2, 14.5 and 19.1 %, respectively. 3. ADF content of rye was slightly higher with both fall cutting(29.99) and no defoliation(29.5%) than that of fall grazing(28.0%). ADF content of rye at the early, mid and late seeding dates was 30.7, 29.1 and 27.7%, respectively. Effect of fall harvest methods and seeding dates on NDF content of rye were similar to the observations made on ADF. 4. RFV and IVDMD of rye were lower with both no defoliation and fall cutting than fall grazing. but those of rye slightly increased with seeding dates progressed. 5. Dry matter yield of rye was the highest of 6,779 kg/ha with fall cutting, while the lowest yield of 6,240 kg/ha was obtained from no defoliation But no significant difference was found among the harvest methods. Dry matter yield of rye was significantly declined with later seedings. It is concluded that the highest forage yield of rye be possible from two harvest systems of fall and spring with earlier seeding rather than from one harvest system of spring.

  • PDF

A Study on Sickness and the Status of Medical Care in a Rural Area (일부(一部) 농촌주민(農村住民)의 상병(傷病) 및 의료실태(醫療實態)에 관(關)한 조사연구(調査硏究))

  • Park, Jeong-Sun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.14 no.1
    • /
    • pp.65-74
    • /
    • 1981
  • This survey was made to determine the overall health situation on (1) the status of sickness; (2) the medical care utilization; (3) the medical cost in Mi-Kum Myun, Nam Yang Ju Gun, Kyung-Gi Do. The survey with questionnaire was carried out with 2,840 peoples in 560 households from August 9th to 16th, 1979. The findings from the survey were as follows; 1. Annual morbidity rate of the prolonged ill cases was 97.2 per 1,000 population (male 94.7, female 99.6), The highest age specific morbidity rate was 274.5 of the 45-to 64-year group and the lowest was 21.9 of the 5-to 14-year group. 2. Annual morbidity rate of the new patients was 777.5 per 1,000 population(male 644.5, female 909.5). 3. The chief complaints distribution of the prolonged ill cases was: local pain 36.6%, indigestion 22.4%, and coughing 7.3%, respectively, In terms of age and sex distribution, a large number of female of the 45-to 64-year group complained of local pain or general pain and a large number of both sexes of the 25-to 44-year group complaned of indigestion. 4. The major diseases of the new patients which classified with International Classfication of Diseases (I.C.D.) were disease of the respiratory system, disease of the digestive system, and disease of the musculo-skeletal system and connective tissue for male, disease of the respiratory system, disease of the digestive system, and accident, poisoning, violence for female. 5. Total ill days of the 92 new patients were 536 days and average ill days per case were $6{\pm}38.3$ days. 6. The rate of receiving treatment in the prolonged ill cases was 82.2%(medical facilities 46.4%, drug stores 27.5%, herb medicine 8.3%). 7. The rate of receiving treatment by first choice of the new patients was 88.0% (drug stores 57.%, medical facilities 28.2%, and herb medicine 2.2%), and the rate of receiving treatment by second choice was 30.9% of first treatment cases (medical facilities 44.0%, drug store 44.0% and herb meicine 12.0%). 8. Annual hospitalization rate per 1,000 population was 12.0 (male 12.0, female 11.9). 9. The locations of medical facilities utilized by out-patients were: in the prolonged ill cases Seoul or other places 66.4%, Nam Yang Ju Gun 33.6%, in cases of the new patients Seoul or other places 35.1% and Nam Yang Ju Gun 64.9% respectively. 10. The satisfaction rate of the new patients by mode of receiving treatment was: in cases of primary utilization by first choice herb medicine 100.0%, medical facilities 88.5%, and drug stores 69.8%, in cases of secondary utilization medical facilities 100.0%, herb medicine 100.0%, and drug stores 72.7% respectively. 11. The medical cost per utilized facilities was as follows; in average medical fee per case out-patient 8.947 won, in-patient 266,000 won, drug stores 1,532 won, and herb medicine 15,607 won, in average medical fee per day out-patient 4,829 won, in patient 14,178 won, drug stores 891 won, and herb medicine 4,906 won respectively. 12. The sources of the hospital charges paid out were: there own expense 50.0%, debt 35.3%, and security of medical care 14.7% respectively.

  • PDF

Imaging of Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression with Radiolabeled 5-(2-iodovinyl)-2'-deoxyuridine (IVDU) in liver by Hydrodynamic-based Procedure (Hydrodynamic-based Procedure를 이용한 간에서의 HSV1-tk 발현 확인을 위한 방사표지 5-(2-iodovinyl)-2'-deoxyuridine (IVDU)의 영상연구)

  • Song, In-Ho;Lee, Tae-Sup;Kang, Joo-Hyun;Lee, Yong-Jin;Kim, Kwang-Il;An, Gwang-Il;Chung, Wee-Sup;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.468-477
    • /
    • 2009
  • Purpose: Hydrodynamic-based procedure is a simple and effective gene delivery method to lead a high gene expression in liver tissue. Non-invasive imaging reporter gene system has been used widely with herpes simplex virus type 1 thymidine kinase (HSV1-tk) and its various substrates. In the present study, we investigated to image the expression of HSV1-tk gene with 5-(2-iodovinyD-2'-deoxyuridine (IVDU) in mouse liver by the hydrodynamicbased procedure. Materials and Methods: HSV1-tk or enhanced green fluorescence protein (EGFP) encoded plasmid DNA was transferred into the mouse liver by hydrodynaminc injection. At 24 h post-injection, RT-PCR, biodistribution, fluorescence imaging, nuclear imaging and digital wholebody autoradiography (DWBA) were performed to confirm transferred gene expression. Results: In RT-PCR assay using mRNA from the mouse liver, specific bands of HSV1-tk and EGFP gene were observed in HSV1-tk and EGFP expressing plasmid injected mouse, respectively. Higher uptake of radiolabeled IVDU was exhibited in liver of HSV1-tk gene transferred mouse by biodistribution study. In fluorescence imaging, the liver showed specific fluorescence signal in EGFP gene transferred mouse. Gamma-camera image and DWBA results showed that radiolabeled IVDU was accumulated in the liver of HSV1-tk gene transferred mouse. Conclusion: In this study, hydrodynamic-based procedure was effective in liver-specific gene delivery and it could be quantified with molecular imaging methods. Therefore, co-expression of HSV1-tk reporter gene and target gene by hydrodynamic-based procedure is expected to be a useful method for the evaluation of the target gene expression level with radiolabeled IVDU.

A STUDY ON IN VIVO AND IN VITRO AMALGAM CORROSION (아말감의 구강내 부식 및 인공 부식에 관한 연구)

  • Lim, Byong-Mok;Kwon, Hyuk-Choon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.1-33
    • /
    • 1997
  • The objective of this study was to analyze the in vitro and in vivo corrosion products of low and high copper amalgams. The four different types of amalgam alloy used in this study were Fine cut, Caulk spherical, Dispersalloy, and Tytin. After each amalgam alloy and Hg were triturated according to the directions of the manufacturer by means of the mechanical amalgamator(Amalgam mixer. Shinhung Co. Korea), the triturated mass was inserted into a cylindrical metal mold which was 12mm in diameter and 10mm in height. The mass was condensed by 150Kg/cm compressive force. The specimen was removed from the mold and aged at room temperature for about seven days. The standard surface preparation was routinely carried out by emery paper polishing under running water. In vitro amalgam specimens were potentiostatically polarized ten times in a normal saline solution at $37^{\circ}C$(potentiostat : HA-301. Hukuto Denko Corp. Japan). Each specimen was subjected to anodic polarization scan within the potential range -1700mV to+400mV(SCE). After corrosion tests, anodic polarization curves and corrosion potentials were obtained. The amount of component elements dissolved from amalgams into solution was measured three times by ICP AES(Inductive Coupled Plasma Atomic Emission Spectrometry: Plasma 40. Perkim Elmer Co. U.S.A.). The four different types of amalgam were filled in occlusal and buccal class I cavities of four human 3rd molars. After about five years the restorations were carefully removed after tooth extraction to preserve the structural details including the deteriorated margins. The occlusal surface, amalgam-tooth interface and the fractured surface of in vivo amalgam corrosion products were analyzed. In vivo and in vitro amalgam specimens were examined and analyzed metallographically by SEM(Scanning Electron Microscope: JSM 840. Jeol Co. Japan) and EDAX(Energy Dispersive Micro X-ray Analyser: JSM 840. Jeol Co. Japan). 1. The following results are obtained from in vitro corrosion tests. 1) Corrosion potentials of all amalgams became more noble after ten times passing through the in vitro corrosion test compared to first time. 2) After times through the test, released Cu concentration in saline solution was almost equal but highest in Fine cut. Ag and Hg ion concentration was highest in Caulk spherical and Sn was highest in Dispersalloy. 3) Analyses of surface corrosion products in vitro reveal the following results. a)The corroded surface of Caulk spherical has Na-Sn-Cl containing clusters of $5{\mu}m$ needle-like crystals and oval shapes of Sn-Cl phase, polyhedral Sn oxide phase. b)In Fine cut, there appeared to be a large Sn containing phase, surrounded by many Cu-Sn phases of $1{\mu}m$ granular shapes. c)Dispersalloy was covered by a thick reticular layer which contained Zn-Cl phase. d)In Tytin, a very thin, corroded layer had formed with irregularly growing Sn-Cl phases that looked like a stack of plates. 2. The following results are obtained by an analysis of in vivo amalgam corrosion products. 1) Occlusal surfaces of all amalgams were covered by thick amorphous layers containing Ca-P elements which were abraded by occlusal force. 2) In tooth-amalgam interface, Ca-P containing products were examined in all amalgams but were most clearly seen in low copper amalgams. 3) Sn oxide appeared as a polyhedral shape in internal space in Caulk spherical and Fine cut. 4) Apical pyramidal shaped Sn oxide and curved plate-like Sn-Cl phases resulted in Dispersalloy. 5) In Tytin, Sn oxide and Sn hydroxide were not seen but polyhedral Ag-Hg phase crystal appeared in internal space which assumed a ${\beta}_l$ phase.

  • PDF