• Title/Summary/Keyword: D.I.Y.

Search Result 11,783, Processing Time 0.047 seconds

Biomonitoring Human Exposure to VOCs : Using Individual Susceptibility Markers

  • Kim, Jung-Hyun;Kim, Dae-Seon;Park, Jae-Sung;Kang, Tack-Shin
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.187-191
    • /
    • 2003
  • In this study, biomonitoring methods were developed to measure BTEXs exposure level in the air, metabolites of benzene and toluene in human urine, individual susceptibility markers in human blood for evaluation of the health effects about environmental pollution. We have also performed a small-scaled molecular epidemiology study on residents in Chuncheon and workers in workplace for these method applications. The workers in workplace were surveyed as study areas, and the residents in Chuncheon which is in the suburban area were surveyed as comparative areas in this study. Actually, 31 workers in as target group and 33 residences in as control group this epidemiological study. The results obtained from this study were as follows: 1. Benzene is a well-known carcinogen, it's median concentrations were 0.00024∼0.02057ppm at suburban area and 0.002∼00.654ppm at work place, These benzene concentrations were not exceed the OSHA(Occupational Safety and Health Administration) threshold benzene level of 1ppm in the states. 2. Metabolites product of benzene(t,t-Muconic Acid) and toluene(Hippuric Acid) were not significant both in suburban and workplace area. The median concentration of t,t-MA and HA were 0.0122, 1.44277g/g creatinine, respectively. 3. In the case of individual susceptibility markers as CYPlAl, 41.8% of them has homozygous wild type(W) and who has heterozygous variant type(H) was 35.4% and 22.8% of homozygous variant type(M) genetic type. In the case of CYP2E1, 62.82% of them has homozygous wild type(D) type, 34.62% of each has heterozygous variant type (DC) and 2.56% of them has homozygous variant type (CC). Who doesn't have GSTM1 gene was 46.25% and who has GSTM1 gene was 53.75%. Who doesn't have GSTT1 gene was 40.0% in study groups and who has GSTT1 gene was 60.0%. Who has W genetic type, which is homozygous wild type of GSTP1, was 69.18% and H genetic type, which is heterozygous variant type was 28.4%. M genetic type which is homozygous variant type was 2.4%. 4. Concentration differences of metabolites such as t,t-MA and HA in urine, which is generated by individual susceptibility marker of GSTM1, GSTT1, GSTP1 gene of Phase I and CYP1A1, CYP2E1 gene of Phase II, was examined. As a result, GSTP1 and GSTM1 indicate slight differences depend on the amount of metabolites in urine, it was not statistically significant.

  • PDF

Aspects of Staphylococcus in Povidone Disinfection of Patients with a Tracheostomy (기관절개술 환자의 Povidone 소독에 따른 포도상구균의 양상)

  • Hong, Hae-Sook;Kim, Yun-Kyung
    • Journal of Korean Biological Nursing Science
    • /
    • v.3 no.2
    • /
    • pp.1-20
    • /
    • 2001
  • The object of this study was to measure the biocidal effect of povidone on staphylococcus found in tracheal incision site, change following the disinfection frequency and duration, and tolerance to the antibiotics. The data was analysed by percentage and t-test using SAS program. The subjects of this study are 35 tracheostomy patients in and Intensive Care Unite of the hospital located in Daegu city and analysing term was from January 16 to February 26, 2001. The results of this study were as follows. The biocidal effect of povidone on Staphylococcus was strong regardless of time and concentration. Staphylococcus aureus was found on third day and found to be highest concentration on 6th day after disinfection of once/a day. Coagulase negative Staphylococcus was not found from 1st to 3rd day and highest on 4th day after disinfection of once/a day. As to bacteria colonization following the disinfection frequency, twice per day of disinfection was more effective on Staphylococcus aureus than once a day. In tolerance test of Staphylococcus aureus and Coagulase negative Staphylococcus, 72.7% of Staphylococcus aureus showed tolerance in Methicillin, 63.6% in Imipenem, and 37.5% of Coagulase negative Staphylococcus showed tolerance in Methicillin, 12.5% in Imipenem. Both of them do not have any tolerance in Vancomycin. The results of this study can be used as the basis for protection against hospital mediated infection through thorough disinfection. With above results, I suggest the following. First, we should research relation between antiseptics and fungi, virus more deeply. Secondly, all medical personnel should try to protect against the hospital medicated infection. Thirdly, there is a need of training professional disinfection personnel for preventing hospital mediated infection and the progress of nursing science.

  • PDF

Quality Characteristics and Storage Improvement of Seasoned Pork Added with Phlomis umbrosa Turcz. Extracts (속단추출물의 첨가로 인한 양념 돈육의 품질특성 및 저장성 향상)

  • Kim, Hyun-Jeong;Kim, Mi-Jin;Oh, Song-I;Jung, Young-Tae;Park, Soo-Kyoung;Lee, In-Seon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.1
    • /
    • pp.102-109
    • /
    • 2011
  • Antioxidant and antibacterial activities of Phlomis umbrosa Turcz. (PU) ethanol extracts were investigated in vitro. Total polyphenols, flavonoids and FRAP values of PU extracts were $57.32{\pm}2.30{\mu}g$/mg, $21.44{\pm}2.52{\mu}g$/mg and 0.26 mmol $Fe^{2+}$/g, respectively. The PU extracts also showed strong DPPH scavenging activity and antibacterial effects against Staphylococcus aureus. In addition, the DPPH scavenging effect of the seasoning sauces was increased by the addition of PU extracts. This study was also conducted to evaluate the quality characteristics of seasoned pork treated with PU extracts during storage at $4^{\circ}C$ for 21 days. Seasoned pork was produced containing 0, 0.5, and 1% PU extracts and 0.1% BHA. The total bacteria and TBARS values of seasoned pork added with PU were decreased compared to the control, whereas coliform bacteria were not detected after longer storage periods. With regards to sensory evaluation, seasoned pork treated with 0.5% PU had higher juiciness, flavor and overall acceptability compared to seasoned fork. These results suggest the possibility of manufacturing seasoned pork with PU extracts for the improvement of shelf-life and quality.

Steam Gasification of Coal and Petroleum Coke in a Thermobalance and a Fluidized Bed Reactor (열천칭과 유동층반응기에서 석탄과 Petroleum Coke의 수증기 가스화반응)

  • Ji, Keunho;Song, Byungho
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1015-1020
    • /
    • 2012
  • Lignite of low rank coal and petroleum coke of high sulfur content can be high potential energy sources for coal gasification process because of their plentiful supply. The steam gasification of lignite, anthracite, and pet coke has been carried out in both an atmospheric thermobalance reactor and a lab-scale fludized bed reactor (0.02 m i.d. ${\times}$ 0.6 m height). The effects of gasification temperature ($600{\sim}900^{\circ}C$) and partial pressure of steam (0.15~0.95 atm) on the gasification rate and on the heating value of product gas have been investigated. The modified volumetric reaction model was applied to the experimental data to describe the behavior of carbon conversion, and to evaluate kinetic parameters of char gasification. The results shows that higher temperature bring more hydrogen in the product syngas, and thus increased gas heating value. The feed rate of steam is needed to be optimized because an excess steam input would lower the gasification temperature which results in a degradation of fuel quality. The rank of calorific value of the product gas was anthracite > lignite > pet coke. Their obtained calorific value at $900^{\circ}C$ with 95% steam feed were 10.0 > 6.9 > 5.7 $MJ/m^3$. This study indicates that lignite and pet coke has a potential in fuel gas production.

Functionalities of Squid Liver Hydrolysates (오징어 간 가수분해물의 기능성)

  • Lee, Su-Seon;Park, Si-Hyang;Park, Joo-Dong;Konno, Kunihiko;Choi, Yeung Joon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.12
    • /
    • pp.1677-1685
    • /
    • 2012
  • The autolysate and hydrolysate of a common squid liver, Todarodes pacificus, were prepared. Autolysis (liver ratio, pH, temperature) and Protamex-treated hydrolysis (pH, temperature, ratio of protease to liver) conditions were optimized by response surface methodology using central composite design for under 1 hr of hydrolysis time. The desirability profile indicated that maximum DH could be achieved at a squid liver of 93.5%, pH 6.4, and $47^{\circ}C$ in autolysis, while that of Protamex-treated hydrolysis did at a Protamex-to-squid liver level of 0.33%, pH 6.0, and $55^{\circ}C$. Three amino acids, proline, cysteine, and methionine, were not detected in the total amino acid composition of the Protamex-treated hydrolysate, while they were detected in the free amino acid composition. Cadmium was $8.32{\pm}0.03$ mg/100 g-powder for raw, $3.56{\pm}0.02$ mg/100 g-powder for the autolysate, and $13.26{\pm}0.04$ mg/100 g powder for the Protamex-treated hydrolysate. The major molecular weight ranged from 1.0 to 1.5 kDa for the autolysate and from 210 to 470 Da for the Protamex-treated hydrolysate. Food functionalities of the autolysate, such as surface hydrolphobicity, emulsion activity index, emulsion stability, water, and fat adsorption, were similar to the Protamex-treated hydrolysate. Both the autolysate and Protamex-hydrolysate showed high inhibitory activities on the angiotensin-I converting enzyme. Cell toxicity against the HepG2 cell line was not detected in the autolysate or the Protamex-treated hydrolysate by 200 ${\mu}g/mL$.

The analgesic effect of combined electroacupuncture at Hoku (LI4) and Zusanli (ST36) using TFL (합곡혈(合谷穴)과 족삼리혈(足三里穴) 병용자극(倂用刺戟)이 TEL에 미치는 영향)

  • Baek, Kyong-Won;Ko, Eun-Sang;Min, Byung-Il;Park, Dong-Suk
    • Journal of Acupuncture Research
    • /
    • v.18 no.1
    • /
    • pp.76-87
    • /
    • 2001
  • Objective : Zusanli(ST36) and Hoku(Li4) are analgesic acupuncture points frequently used for acupuncture in Oriental medicine. The present study was conducted to see the antinociceptive effects produced by electroacupuncture combined two frequencies(Low, High) and two different acupuncture points(LI4, ST36) in the rat tail flick test. Method : In this study the Rats (Sprague-Dawley, 250-300g) were partially anesthetized with thiopental sodium(40mg/kg, i.p.). The basal reaction time for the tail-flick was 3${\pm}$0.5 sec. Low frequency(3Hz, 5V, biphasic) and high frequency(100Hz, 5V, biphasic) were applied to the inserted needle for the period of insertion(twenty minutes). Experimental groups are divied as follow; a) electroacupuncture stimulation groups at Hoku with or high frequency(L-EA, H-EA), b) electroacupuncture stimulation groups at Zusanli with low or high frequency(1-EA, h-EA), c) low frequency at Hoku and Zusanli(LIEA), d) low frequency at Hoku and high frequency at Zusanli(LhEA), e) high frequency at Hoku and low frequency at Zusanli(HIEA), f) high frequency at Hoku and Zusanli(HhEA) Results : The individual stimulation at either Hoku or Zusanli with low frequency has stronger and longer analgesic effect than high frequency stimulation. In addition, the combined stimulation at Hoku and Zusanli with low frequency has superior effect to individual stimulation with low frequency. LhEA and LIEA have superior effect to other stimulation groups among the combined groups. In order to determine the involvement of opioid system on the different antinociceptive effects, Naloxone, an opioid antagonist, was used in the combined groups. LIEA is the most sensitive when naloxone was administrated among study groups. HhEA is the least sensitive in the administration of naloxone. Conclusion : From results, this study confirmed that the opioid system is involved in analgesic effect of low frequency stimulation of acupuncture point, and we also can suggest the stronger analgesic effect of combining stimulation points is due to the theory of spatial summation in the nervous system.

  • PDF

A Study on the Effects of Supportive Touch and Patient Educative on the Patient이s Post-operative Pain (지지적 접촉과 환자교육이 수술후 동통에 미치는 영향에 관한 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.15 no.3
    • /
    • pp.5-20
    • /
    • 1985
  • The purpose of this study was to assess the value-of post-operative treatment in terms of nursing care in the allevation of pain. More specifically, the effects of supportive touch and patient education were examined. On the date before each patient's operation, the Bevels of anxiety, depression and affiliation were examined. The post-operative treatment was adminis. tered after an initial measurement of the patient's fain, according to the experimental category for the three days following the operation. On the final day, the level of anxiety and depression were again measured. The subjects of this study were 138 patient from the general surgical and gynecological wards in H university Hospital in Seoul. The study was conducted over a three-month period from June 24, 1984 to September 18, 1984. All patients had undergone laparatomies. Various standard instruments were used to measure the pain, anxiety, depression and affiliation levels. for pain, 5 grate Simple Descriptive Scale, and the Mclachlan four-range Observational Pain Scale were employed. For anxiety and depression, respectively the Spielberger State Anxiety Inventory and Beck Depression Inventory (B.D.I.) were used. Lastly, the affiliation was determined by the Mehrabian Affiliation Scale. The outcome of the research was as follows: 1. The first hypothesis concerning the existence of lower pain levels of Experimental Group A and Experimental Group B than the pain levels of Control Croup C was not supported. 2. The second hypothesis concerning the existence if lower anxiety levels of Experimental Group A and Experimental Group B than the anxiety levels of Control Group C was supported at the level of F=3.58 (p=.03). 3. The third hypothesis concerning the existence of lower depression levels of Experimental Group A and Experimental Group B than the depression levels of Control Group C was not supported. 4. The fourth hypothesis concerning the existence of different levels of pain in accordance with the levels of affiliation in Experimental Group A was not supported. 5. A positive correlation did exist between pain and anxiety after surgery (r=.34, p=.0001). Thus, the fifth hypothesis was supported. 6. A positive correlation did exist between pain and depression following surgery(r=.36, p=.0001). Thus, the sixth hypothesis was supported. Based on the above results, it was found that supportive touch and patient education either through human sources or via tape recorder do influence the anxiety of a patient after surgery, that a Positive correlation between pain, anxiety and deparession exist, that affiliation does not alter the influence of supportive touch, and that the graph on which pain levels were depicted indicates the possibility of development even if the effects of supportive touch did not reach a meaningful level. Thus it can be concluded that patient education, regardless of its form, is essential for the patient after surgery and that supportive touch, when reasonably modified and supplemented, can be an effective method of alleviating pain.

  • PDF

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

Holographic phase gratings in back- and frontlights for LCD's

  • Bastiaansen, C.W.M.;Heesch, C. van;Broer, D.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.421-421
    • /
    • 2006
  • The light and energy-efficiency of classical liquid crystal displays is notoriously poor due to the use of absorption-based linear polarisers and colour filters. For instance, the light efficiency of PVAL polarisers is typically between 40 and 45 % and the colour filters have a typical efficiency below 35 % which results in a total light and energy-efficiency of the display below 10 %. In the past, a variety of polarizers were developed with an enhanced efficiency in generating linearly polarized light. Typically, these polarizers are based on the polarisationselective reflection, scattering or refraction of light i.e. one polarisation direction of light is directly transmitted to the LCD/viewer and the other polarization direction of light is depolarised and recycled which results in a typical efficiency for generating linearly polarized light of 70-85 %. Also, special colour filters have been proposed based on chiral-nematic reactive mesogens which increase the efficiency of generating colour. Despite the enormous progress in this field, a need persists for improved methods for generating polarized light and colour based on low cost optical components with a high efficiency. Here, the use of holographic phase gratings is reported for the generation of polarized light and colour. The phase grating are recorded in a photopolymer which is coated onto a backor frontlight for LCDs. Typically the recording is performed in the transmisson mode or in the waveguiding mode and slanted phase gratings are generated with their refractive index modulation at an angle between 20o and 45o with the normal of the substrate. It is shown that phase gratings with a high refractive index modulation and a high efficiency can be generated by a proper selection of the photopolymer and illumination conditions. These phase gratings coupleout linearly polarized light with a high contrast (> 100) and the light is directed directly to the LCD/viewer without the need for redirection foils. Dependent on the type of phase grating, the different colours are coupled-out at a slightly different angle which potentially increases the efficiency of classical colour filters. Moreover, the phase gratings are completely transparent in direct view which opens the possibility to use them in frontlights for LCDs. Holographic polarization gratings posses a periodic pattern in the polarization state of light (and not in the intensity of light). A periodic pattern in the polarization direction of linearly polarized light is obtained upon interference of two circularly polarized laser beams. In the second part of the lecture, it is shown that these periodic polarization patterns can be recorded in a linear photo-polymerizable polymer (LPP) and that such an alignment layer induces a period rotation in the director of (reactive and non-reactive) liquid crystals. By a proper design, optical components can be produced with only first order diffraction and with a very high efficiency (>0.98). It is shown that these diffraction gratings are potentially useful in projection displays with a high brightness and energy efficiency

  • PDF

A Study on the Contamination of Solution with Suction used in Tracheostomy Patients (기관지절개술 환자의 흡인시 사용하는 용액의 오염수준 변화 연구)

  • Lim Yun-Hee;Yu Kwang Soo
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.2
    • /
    • pp.185-200
    • /
    • 1998
  • It has been contributed to public health that the hospital has multiplied in the aspect of number and has been a large size with development of modern medical science, meanwhile the problem of hospital infection is coming out seriously. Respiratory hospital infection among hospital infections develops, very commonly from patients having taken the operation of intubation or tracheostomy, which results from a big factor that the infection developed from medical appliances used for respiration aids, contamination of solution and infection of medical staff. This study is separated into four steps-the time to use normal saline and distillation water for storaging catheter which are the cause of the infection of solution to store distillation water and catheter, not to say the catheter used when the patient who should get tracheostomy operation takes suction. The purpose of this study is to offer the basic data which are needed to check contamination degree as time goes by and nurse intervention and grope for a new nursing intervention. The target of this study is hospitalized 1D an intensive care unit having 700 sickbeds which is located in IKSAN city and it targeted patients before 7 days passed after an operaion of a tracheostormy. Materials collected were analyzed by SPSS PC+ figures program. The result of this study were as follows ; 1. The gradual contamination levels of the normal saline used In suction are showing that colony increase in proportion to the length of time. 2. while colony increases in normal saline with the lapse of time. distillation water mixed with 5cc of potadine did not show any sign of the formation of colony from its preparation until it was used for 8 hours. 3. Such variables as the period of intubation insertion. the length of hospitalization in I.C.U. the age and the level of contamination of normal saline have no inter-relationship. Therefore. as the length of normal saline used In suction. the contamination level increases with the excelleration of the contamination speed. 4. Regarding the number of suction and the contamination level of the normal saline. We can observe correlation contamination level in the 3 step of suction(mean value:13.4) and the saline which was used for one hours(r=0.702. P=0.00l). four hours(r=0.694. P=0.00l). eight hours(r=0.488. P=0.029). Further we can observe contamination in the 4 step of suction (mean value: 17 .8) well as saline used for eight hours; [for one hours (r=0.64l. P=0.002). four hours (r=0.670. P=0.00l). eight hours (r=0.57 4. P=0.008)]. Thesedays clinics use normal saline by changing it. three times a day. however. the timing of saline change and the current suction methoed should be changed given the one hour used normal saline contamination number 79.850. Regarding the number of suction and the contamination lend of the normal saline.

  • PDF