• Title/Summary/Keyword: D.B.H. analysis

Search Result 1,378, Processing Time 0.038 seconds

FEM Analysis for the Prediction of Void Closure On the Open Die Forging Process (자유단조공정에서 기공폐쇄 예측을 위한 유한요소해석)

  • Min, K.Y.;Lim, S.J.;Choi, H.J.;Choi, S.;Park, Y.B.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.71-74
    • /
    • 2008
  • In order to resolve the problems which appear after the clean large ingot production process, the impurities which are involved in the steel smelting process should be removed by developing cleaner materials. Through the rationalization of cogging process that is the first forging process of large ingot the quality is to be improved. For the sake of the optimization of an open die forging process and the improvement of the subject matter frequency ratio, a hazard precise die forging process must be developed and a Near Net Shape Forming accomplished. As a result, energy can be reduced by minimizing an after control process. In order to produce large axes and other forming parts, processing techniques are to be developed. In this context, this paper is a study about a reduction ratio, dies width ratio and rotary angles, the amount of overlap, and intends to analysis cogging processes, utilizing Deform-3D cogging module

  • PDF

Studies on Moisture Evaporation and Economical Analysis for Composting of Piggery Slurry (양돈 슬러리 퇴비화 방법의 수분증발율 및 경제성 분석에 관한 연구)

  • Park, C.H.;Yoon, T.H.;Ryoo, J.W.;Kim, J.H.;Choi, T.B.;Choi, D.Y.;Kwag, J.H.;Jeong, K.W.;Kim, H.H.
    • Journal of Animal Environmental Science
    • /
    • v.8 no.2
    • /
    • pp.119-124
    • /
    • 2002
  • To evaluate composting process of piggery slurry, we made $1m^3$ bench scale composting reactor, and investigated the input and output of mass, moisture evaporation, volatile solid degradation, and running cost. For 15 days experimentation the results was as followed, The quantity of sawdust used was 0.47ton(18,000won) per 1ton slurry. The amount of moisture evaporated was 16.8kg/kg VS degradated. Total evaporation and VS degradation were 24.8%, 5.7% respectably. To analysis the running cost of that, we included only two factors, sawdust cost and compost income. The compost price to sell was 63won/kg(50% of market price) it made 8,694won income to 756 won loss, but 25won/kg, it was $13,650{\sim}23,100won$ loss per 1 ton slurry in the current pig farmer's condition. This cost was $8.5{\sim}14.4%$ of pig production cost and damage strongly to pig farmers to treat it.

  • PDF

EFFECT OF STANDING AND LYING BEHAVIORS ON HEAT PRODUCTION OF DAIRY HEIFERS DIFFERING IN FEED INTAKE LEVELS

  • Purwanto, B.P.;Matsumoto, T.;Nakamasu, F.;Ito, T.;Yamamoto, Sadaki
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.2
    • /
    • pp.271-274
    • /
    • 1993
  • Four Holstein heifers were used in the present study to investigate the effect of standing and lying behaviors on heat production and physiological responses under low (L), medium (M) and high (H) levels of TDN intake. Rectal temperature (RT), respiration rate (RR), heart rate (HR), heat production (HP) and animals behavior (standing time, ST) were measured continuously for 5h (11:00-16:00) periods. There was a tendency for increased RT with TDN intake, and no difference in RT was observed between standing and lying. The RR, HR and HP during standing were significantly higher (p<0.05) than during lying. The difference between standing and lying HP were 4.41, 4.68 and $5.37kJ/kg^{0.75}$ h for L, M and H of TDN intake, respectively. These values showed that standing HP was 18.6-20.9% higher than lying HP. A multiple regression analysis of HP ($kJ/kg^{0.75}$ h) on TDN intake ($g/kg^{0.75}$ d) and ST (min/h) was HP = 7.75 + 0.28 TDN intake + 0.12 ST (R = 0.84). This analysis showed that the total HP not only depend on feed intake levels, but also depends on animal behavior. It was suggested that the change in HP due to the change in feed intake and animal behavior would influence the level of heat loss which was indicated by the changes in the RR and HR.

Hydroelastic Analysis of Structural Vibration in Contact with Fluid (접수구조물 진동의 유력탄성해석)

  • K.T. Chung;Y.B. Kim;H.S. Kang;J.H. Roh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.1
    • /
    • pp.135-142
    • /
    • 1992
  • In the vibration analysis or submerged of floating bodies such as ship and offshore structures, the coupled system between structure and fluid satisfying the compatibility conditions on the wetted surface should be considered. It is well known that the hydroelastic analysis of structural vibration in contact with fluid can be solved by applying the finite element method to structure and the boundary element method to fluid domain. However such an approach is impractical, because fluid added mass matrix is fully coupled on whole wetted surface. To overcome this shortcoming, an efficient approach based on reanalysis scheme is proposed in this paper. The proposed method can be applied for cases with higher modes lacking 3-D reduction factor J as well as beam-like modes of marine structures. It is well known the traditional method using 2-D added mass and J-factor is good only for beam-like modes with reliable J values. The validity and the calculation efficiency of the proposed method are proved with numerical examples.

  • PDF

Survey & Analysis for the Calculation on the Industrial Customer Interruption Costs (산업용 수용가의 정전비용 산출을 위한 조사 분석(I))

  • Nam, K.Y.;Choi, S.B.;Ryoo, H.S.;Jeong, S.H.;Lee, J.D.;Kim, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.122-124
    • /
    • 2003
  • In recent, the various electric & electronic machines are newly developed everyday and the electricity supply system & environment on the process from generation to consumption of electricity also is being changed. In other words, both supplier and consumer of electricity are required to be responsible for their interruption costs. So, it is very important and meaningful work for evaluating the interruption costs in quantitative. Additionally, since the restructuring of electric industry is on going in world wide, after restructuring, most of all electric utilities and consumer have to consider the supply reliability and quality as a important element of the calculating the related costs and contract because it takes costs to keep the supply reliability and quality highly. Especially, the interruption or the supply reliability will have influence on the bilateral contract between supplier and customer as a key point to determine the once in competitive electric market. Therefore, it has very important moaning to calculate the interruption costs in the present that it is prepared to open the competitive electric market. In this paper, international standards, i.e. IEC, IEEE, are applied to the analysis on the interruption costs used in the questionnaires which are newly designed including short duration interruption by the authors instead of traditional interruption criteria. Firstly, using the questionnaires, the authors got related data from industries according to the standard industry classification which are being used in electric utility and other national statistics in Korea. However, analysis results are hard to say typical value because of the not so many samples. So, the authors are going to survey and focus on not all kinds of industry but a few kinds of them that their facilities are effected or stop by short duration interruptions, so there are large economical damages. Finally, the authors hope to find the reliable and meaningful model in interruption costs of industrial customer.

  • PDF

ISM Properties and Star Formation Activities in IC 10 : 2D Cross Correlation Analysis of Multi-wavelength data

  • Kim, Seongjoong;Lee, Bumhyun;Oh, Se-Heon;Chung, Aeree;Rey, Soo-Chang;Jung, Teahyun;Kang, Miju
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.31.3-32
    • /
    • 2015
  • We present the physical properties of star forming regions in IC 10 obtained from Korea VLBI Network (KVN) 22GHz, the Submillimeter Array (SMA) CO, Very Large Array (VLA) HI 21cm, optical (U, B, V and H-alpha), and Spitzer infrared observations. IC 10 is a nearby (~0.7Mpc) irregular blue compact dwarf (BCD) galaxy which is likely to be experiencing an intense and recent burst of star formation. This nearby infant system showing high star formation rate but low metallicity (<20% of that of the Sun) provides critical environment of interstellar medium (ISM) under which current galactic star formation models are challenged. To make quantitative analysis of the ISM in the galaxy, we apply 2D cross-correlation technique to the multi-wavelength data for the first time. By cross-correlating different tracers of star formation, dust and gas phases in IC 10 in a two dimensional way, we discuss the gas properties and star formation history of the galaxy.

  • PDF

Effect of Residual Stress on Femoral Arterial Stress-Strain Behavior

  • Chandran, K.B.;Mun, J.H.;Chen, J.S.;Nagaraj, A.;McPherson, D.D.
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2001
  • It is well established that arteries are subjected to residual stress. Due to the effect of residual stress, the arteries open to a horse-shoe shape when a longitudinal cut is made on an excised arterial segment. Previously, the residual stress has been quantified by the opening angle of the horse-shoe shape. We have employed a finite element analysis of the open arterial segment to restore the same to the original cylindrical shape and computed the circumferential strain as well as the stress distribution in the wall. In this study, the stress distribution in the femoral arteries of miniswine was computed with and without the residual stress for a range of transmural pressures. Our analysis showed that the residual stress has the effect of redistribution of the circumferential stresses between the intima and the adventitia under physiological loading. The redistribution of the stress with the inclusion of residual stress may be important in the studies on effect of wall stresses on the endothelial and vascular smooth muscle cells.

  • PDF

Analysis of the Plantar Pressure on the Flat and Slope Walking by Insole Type

  • Kim, Bu Gan;Lee, Joong Sook;Yang, Jeong Ok;Lee, Bom Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.165-173
    • /
    • 2018
  • Objective: The purpose of this study is to provide biomechanical basis data for the analysis of the maximum vertical ground reaction force, the maximum plantar pressure, the average plantar pressure, and the contact area according to the type of the insole through the insole insertion type foot pressure gauge. Method: In the treadmill, the slope was set at 10%, the first type A was worn at a walking speed of 3.5 km / h, and then walking was carried out using B, C, and D types. Data from 20 boots with consistent walking were extracted and plantar pressure data were collected and analyzed. Results: Functional insole was more effective than conventional insole for maximum vertical ground reaction force, maximum plantar pressure, average plantar pressure, and contact area at 10% of treadmill ramps. Conclusion: In this study, D-type insole supports the cushion in the middle part and supports the heel cup with hardness in the hind part, so that it is the most effective insole by lowering the plantar pressure and dispersing it more widely.

Application of Low Frequency Region of Microwave Transmission Spectrum in the Cutoff Probe

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.147-147
    • /
    • 2012
  • Cutoff probe has been used for measuring a plasma density using the cutoff peak which is located at the plasma frequency in the low pressure plasma. However, research on analysis of low frequency region of transmission microwave frequency (TMF) spectrum does not performed even though important plasma parameters are located in the low frequency region, i.e., ion plasma frequency and collision frequency. In this research, we analyzed the low frequency region of the TMF spectrum. Experimental results reveal the effect of plasma parameters on the low frequency region on the TMF spectrum. Based on the response of TMF spectrum from changing of plasma parameters, deduction of the plasma parameters was tried. This comprehensive analysis of TMF spectrum expands applicable area of cutoff probe.

  • PDF

Measurement of Local Heat Transfer Coefficients and Numerical Analysis in the Flow Passage of Disc Brake with Spirally Grooved Surfaces (나선형 홈을 가진 브레이크 유로 내에서의 국소 열전달 측정 및 열 유동 해석)

  • Lee, D.H.;Park, S.B.;Lim, C.Y.;Kim, H.S.;Lee, K.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.104-111
    • /
    • 2006
  • A ventilated disc brake having spirally fluted surface has been proposed to improve the thermal judder by way of heat transfer enhancement. The local heat transfer coefficients were measured in the flow passage of disc brake. These measured local heat transfer data were utilized to do the finite element numerical analysis which predicts the maximum temperatures on the disc brake. The results show that the maximum temperatures on the disc surface with spirally fluted surface are approximately 26.6% lower than those without them.