Synthesis and Biological Activity of Poly[(tri-O-acetyl-D-glucal)-alt-(maleic anhydride)] Derivatives

  • Han, Man-Jung;Lee, Choong-Whan;Kim, Ki-Ho;Lee, Won-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.1
    • /
    • pp.85-87
    • /
    • 1991
  • Poly[(tri-O-acetyl-D-glucal)-alt-(maleic anhydride)] was synthesized by free radical copolymerizations of the relevant comonomers. The alternating sequence of the copolymer was confirmed by $^1$H-NMR, elemental analysis, and titration of anhydride groups incorporated into the copolymer. Hydrolysis of the copolymer under different conditions resulted in poly[(2-acetoxymethyl-3,4-diacetoxytetrahydropyran-5,6-diyl) (1,2-dicarboxyethylene)] and poly[(2-hydroxymethyl-3,4-dihydroxytetrahydropyran-5,6-diyl) (1,2-dicarboxyethylene)]. The cytotoxicities of these polymers measured against normal and tumor cells (3LL, B16) in vitro were found to be higher than that of DIVEMA, a prototype polymer having a high antitumor activity.

Development of an Adaptive Neuro-Fuzzy Techniques based PD-Model for the Insulation Condition Monitoring and Diagnosis

  • Kim, Y.J.;Lim, J.S.;Park, D.H.;Cho, K.B.
    • Electrical & Electronic Materials
    • /
    • v.11 no.11
    • /
    • pp.1-8
    • /
    • 1998
  • This paper presents an arificial neuro-fuzzy technique based prtial discharge (PD) pattern classifier to power system application. This may require a complicated analysis method employ -ing an experts system due to very complex progressing discharge form under exter-nal stress. After referring briefly to the developments of artificical neural network based PD measurements, the paper outlines how the introduction of new emerging technology has resulted in the design of a number of PD diagnostic systems for practical applicaton of residual lifetime prediction. The appropriate PD data base structure and selection of learning data size of PD pattern based on fractal dimentsional and 3-D PD-normalization, extraction of relevant characteristic fea-ture of PD recognition are discussed. Some practical aspects encountered with unknown stress in the neuro-fuzzy techniques based real time PD recognition are also addressed.

  • PDF

Analysis of a new Soft-Switching High-Frequency Inverter for High Current (대전류화를 위한 새로운 소프트 스위칭 고주파 인버터의 회로 해석)

  • Lee, E.Y.;Ra, B.H.;Suh, K.Y.;Kwon, S.K.;Lee, H.W.;Kwak, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1187-1189
    • /
    • 2002
  • In the case of an existing high frequency inverter is became forced extinction by quick load change, due to be connected with series inductor on switch, it is destroyed or is generated conduction loss by resistance component in reactor. And, In the operation of high current with a soft switching, conduction loss can not neglect. In this paper, for the high current power source, we make sure of soft swtching operation and reducing surge when the forced extinction by using a connected switch with series inductor. Also, we poropos a topology of the half bridge type high frequency inverter that can be realized high amplitude operation of the load current. And, analyze the circuit to decide an opmtial circuit parameter.

  • PDF

Characteristic analysis of low frequency vibration forming (저주파 가진 성형의 특성 분석)

  • Park, C.J.;Choi, J.P.;Park, D.Y.;Hong, N.P.;Lee, H.J.;Lee, N.K.;Kim, S.O.;Chu, Andy;Kim, B.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.254-258
    • /
    • 2009
  • In this paper, the low frequency vibration forming system is developed for micro-patterns formation on the metal substrate. many researchers have studied about micro-forming technologies such as micro deep drawing, press forming, forging, extrusion etc. for the formation of precise micro-patterns on the surface of metal substrates, multi-step forming process must be used to improve qualifies of the deformed patterns. Since the low frequency vibration forming system could easily deform the surface of metal substrates, several steps of multi-step forming process should be removed by using the low frequency vibration forming system. In order to find optimal process conditions, we have carried out low frequency vibration forming process with varying the vibration frequency from 110Hz to 500Hz.

  • PDF

Analysis of an Active Clamp Forward Converter with Current-Doubler Rectifier for Wide Range Zero Voltage Switching (전류증배 정류회로를 사용한 능동 클램프 포워드 컨버터의 개선된 영전압 스위칭에 대한 분석)

  • Kim, D.H.;Jang, Paul;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.137-138
    • /
    • 2013
  • 능동 클램프 포워드 컨버터의 2차단에 전류 증배 정류회로를 사용할 경우 2차단에서의 도통 손실을 줄일 수 있다. 뿐만 아니라 상대적으로 큰 자화 인덕턴스와 작은 누설 인덕턴스를 이용하여 영전압 스위칭을 달성할 수 있으므로 회로 전체 동작 측면에서 바람직하다. 본 논문에서는 제안된 회로의 동작 설명과 함께 영전압 스위칭을 위한 조건을 다루었고 240W급 (12-V/20-A) 프로토타입 회로를 통해 분석 결과의 타당성을 검증하였다.

  • PDF

Phenomenological behavior of Bubbles and dry spots at CHF on a short heated wall: Pool boiling of R-113 (소형가열면에서 CHF 발생시 Bubble 및 Dry Spot의 현상학적 거동 R-113의 수조비등)

  • Chung, H.J.;Kim, B.D.;Chun, S.Y.;No, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.189-194
    • /
    • 2001
  • A simultaneous visualization of the behavior of bubbles and dry spots has been carried out for pool boiling of R-1l3 on a horizontal heater. From video imaging and image processing analysis, the formation of bubbles and dry spots occurs simultaneously, and therefore they should be considered as a synchronized concept rather than independent identities. The dry spot density is equivalent to the active site density in the region before CHF. At CHF point, large dry areas due to the coalescence of neighboring dry areas cover the heater surface.

  • PDF

The Comparison of X-ray Response Characteristics of Vacuum Evaporated $Cd_{1-x}Zn_{x}Te$ Detector (진공증착된 $Cd_{1-x}Zn_{x}Te$ 검출기의 X선 반응 특성 비교)

  • Kang, S.S.;Choi, J.Y.;Lee, D.G.;Cha, B.Y.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.39-42
    • /
    • 2002
  • There is a renewed interest in the application of photoconductors especially Cd(Zn)Te to x-ray imaging. In this paper, We investigate effects on x-ray detection characteristic of Zn dopped CdTe detector. Cd(Zn)Te film was fabricated by vacuum thermal evaporation method and then investigate physical analysis using EPMA and XRD. We investigated the leakage current and X-ray photosensitivity as applied voltage about fabricated Cd(Zn)Te film. Experimental results showed that the increase of Zn dopped concentration in $Cd_{1-x}Zn_{x}Te$ detector reduced a leakage current and improved a signal to noise ratio significantly.

  • PDF

EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear (가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석)

  • Chung, Y.H.;Lee, D.S.;Kim, J.B.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

UNSTEADY AERODYNAMIC ANALYSIS OF HELICOPTER ROTOR BLADES USING DIAGONAL IMPLICIT HARMONIC BALANCE METHOD (대각 내재적 조화균형법을 이용한 헬리콥터 로터 블레이드의 비정상 공력 해석)

  • Im, D.K.;Choi, S.I.;Park, S.H.;Kwon, J.H.
    • Journal of computational fluids engineering
    • /
    • v.16 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • In this paper, the diagonal implicit harmonic balance method is applied to analyze helicopter rotor blade flow. The periodic boundary condition for Fourier coefficients is also applied in hover and forward flight conditions. It is available enough to simulate the forward flight problem with only one rotor blade using the periodic boundary condition in the frequency domain. In order to demonstrate the present method, Caradonna & Tung's rotor blades were used and the results were compared to the time-accurate method and experimental data.

The comparison of AE and Acceleration transducer for the early detection on the low-speed bearing (저속 회전 베어링 결함 검출을 위한 AE와 가속도계 변환기 비교)

  • Kim, H.J.;Gu, D.S.;Jeong, H.E.;Tan, Andy;Kim, Eric;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.324-328
    • /
    • 2007
  • Vibration monitoring of rolling element bearings is probably the most established diagnostic technique for rotating machinery. Acoustic Emission (AE) Analysis is an extremely powerful technology that can be used within a wide range of applications of non destructive testing. Therefor, this paper investigates the detection methods using AE for rolling element bearings about low-speed. Two transducers, the accelerometer and acoustic emission sensor, are used to acquire data and the results are compared for the capacity of early fault detection.

  • PDF