• 제목/요약/키워드: D-values

Search Result 7,369, Processing Time 0.041 seconds

3D Reconstruction Method for 3D Engraving Systems (3D 조각가공 시스템을 위한 3 차원 복원 방법)

  • Lee, Won-Seck;Chung, Sung-Chong
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1204-1209
    • /
    • 2008
  • Design is important in the IT, digital appliance, and auto industries. Aesthetic and art images are being applied for better design satisfaction of the products. Various artistic image patterns are used to satisfy demand of design, but it takes much lead-time and effort to implement them for making dies and molds. In this paper, a hybrid reverse engineering method generating accurate 3D engraving models from 2D art images is proposed through image processing, 3D reconstruction, and NURBS interpolation methods. In order to generate the 3D model from the 2D artistic image, cloud points with z-depth are extracted according to intensity values of the image. An adaptive median filter and harmonic filter are used to obtain the intensity values accurately. NURBS surfaces are generated through the interpolation of the cloud points. Performance of the developed system is to be confirmed through the realization of Mona Lisa and Golden Gate Bridge.

  • PDF

2D to 3D Anaglyph Image Conversion using Linear Curve in HTML5 (HTML5에서 직선의 기울기를 이용한 2D to 3D 입체 이미지 변환)

  • Park, Young Soo
    • Journal of Digital Convergence
    • /
    • v.12 no.12
    • /
    • pp.521-528
    • /
    • 2014
  • In this paper, we propose the method of converting 2D image to 3D image using linear curves in HTML5. We use only one image without any other information about depth map for creating 3D images. So we filter the original image to extract RGB colors for left and right eyes. After selecting the ready-made control point of linear curves to set up depth values, users can set up the depth values and modify them. Based on the depth values that the end users select, we reflect them. Anaglyph 3D is automatically made with the whole and partial depth information. As all of this work has been designed and implemented in Web environment using HTML5, it is very easy and convenient and end users can create any 3D image that they want to make.

Dose comparison between prescription methods according to anatomical variations in intracavitary brachytherapy for cervical cancer

  • Choi, Euncheol;Kim, Jae Ho;Kim, Ok Bae;Byun, Sang Jun;Kim, Jin Hee;Oh, Young Kee
    • Radiation Oncology Journal
    • /
    • v.36 no.3
    • /
    • pp.227-234
    • /
    • 2018
  • Purpose: We compared how doses delivered via two-dimensional (2D) intracavitary brachytherapy (ICBT) and three-dimensional (3D) ICBT varied anatomically. Materials and Methods: A total of 50 patients who received 30 Gy of 3D ICBT after external radiotherapy (RT) were enrolled. We compared the doses of the actual 3D and 2D ICBT plans among patients grouped according to six anatomical variations: differences in a small-bowel V2Gy, small bowel circumference, the direction of bladder distension, bladder volume, sigmoid V3.5Gy, and sigmoid circumference. Seven dose parameters were measured in line with the EMBRACE recommendations. Results: In terms of bladder volume, the bladder and small-bowel D2cc values were lower in the 150-250 mL bladder volume subgroup; and the rectum, sigmoid, and bladder D2mL values were all lower in the >250 mL subgroup, for 3D vs. 2D ICBT. In the sigmoid V3.5Gy >2 mL subgroup, the sigmoid and bladder D2mL values were significantly lower for 3D than 2D ICBT. The bladder D2mL value was also significantly lower for 3D ICBT, as reflected by the sigmoid circumference. In patients with a small bowel V2.0Gy >10 mL or small bowel circumference >15%, most dose parameters were significantly lower for 3D than 2D ICBT. The bladder distension direction did not significantly affect the doses. Conclusion: Compared to 2D ICBT, a greater bladder volume can reduce the internal 3D ICBT organ dose without affecting the target dose.

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

Changes of Distribution Coefficients of Cu, Cr, and As in Different Soil Matrix in a Laboratory Scale

  • Kang, Sung-Mo;Ra, Jong-Bum;Kim, Suk-Kuwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.137-140
    • /
    • 2009
  • Chromated copper arsenate (CCA), a long history of successful preservative, have raised environmental concerns. Adsorption characteristics of domestic soils for chromium, copper, and arsenic were assessed by measuring distribution coefficient ($K_d$) values of these metal components in a laboratory scale. The results revealed that $K_d$ values were higher in chromium, followed by arsenic and copper in soil matrix. Different soil matrixes resulted in varying mobilities of CCA components. The values of $K_d$ for all three metals increased with organic matter contents. The results suggest that the mobility of metal components may be very limited to the surface area adjacent to CCA-treated wood due to their fairly large distribution coefficient ($K_d$). However, the metal components would be persistent and accumulated in the soil, resulting in high chemical concentration in service area of treated wood.

Preventive Effects of Typhae Pollen on the Diet-induced Hyperlipidemia in Rats (흰쥐의 식이성 고지혈증에 대한 포황의 예방 효과)

  • 신형섭;김규열;서일복;김호현
    • The Journal of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.32-39
    • /
    • 2003
  • Objectives : In Oriental Medicine, hyperlipidemia is considered as phlegm retention (痰飮) and blood stasis (瘀血). Typhae pollen helps remove blood stasis and hemorrhage, and it also has an effect of relieving pain caused by blood stasis. The purpose of this study is to investigate the preventive effects of Typhae pollen on diet-induced hyperlipidemia in rats. Methods : Thirty-two male Sprague-Dawley rats were divided into normal, control and treated groups. The control and treated groups were fed with a 1.5% cholesterol diet over 4 weeks, and extract of Typhae pollen was administered to the treated group during the same period. Blood samples were collected from each animal at 0 and 4 weeks and used for the blood chemical analysis. Animals were sacrificed at 4 weeks and chemical analysis was performed on the collected liver samples. Results : The serum total cholesterol ($122.45{\pm}4.96mg/dL$), LDL-cholesterol ($54.27{\pm}4.95mg/dL$), and triglyceride ($122.00{\pm}7.33mg/dL$) values of the treated group were significantly lower compared with the serum total cholesterol ($147.91{\pm}7.22mg/dL$), LDL-cholesterol ($81.91{\pm}8.34mg/dL$), and triglyceride ($169.27{\pm}12.34mg/dL$) values of the control group. The liver total cholesterol (TEX>$230.18<{\pm}18.81mg/dL$) values of the treated group were significantly higher compared with the liver total cholesterol ($178.54{\pm}$10.11mg/dL) values of the control group. Conclusions : On the basis of these results, it is confirmed that Typhae pollen has preventive effects on diet-induced hyperlipidemia in rats.

  • PDF

A Study on Create Depth Map using Focus/Defocus in single frame (단일 프레임 영상에서 초점을 이용한 깊이정보 생성에 관한 연구)

  • Han, Hyeon-Ho;Lee, Gang-Seong;Lee, Sang-Hun
    • Journal of Digital Convergence
    • /
    • v.10 no.4
    • /
    • pp.191-197
    • /
    • 2012
  • In this paper we present creating 3D image from 2D image by extract initial depth values calculated from focal values. The initial depth values are created by using the extracted focal information, which is calculated by the comparison of original image and Gaussian filtered image. This initial depth information is allocated to the object segments obtained from normalized cut technique. Then the depth of the objects are corrected to the average of depth values in the objects so that the single object can have the same depth. The generated depth is used to convert to 3D image using DIBR(Depth Image Based Rendering) and the generated 3D image is compared to the images generated by other techniques.

A Study on LED Distance Recognition Measure Using Distance Measurement Correction Algorithm (거리계산 보정 알고리즘을 이용한 LED 거리 인식 측정에 관한 연구)

  • Kim, Ji-Seong;Jung, Dae-Chul;Kim, Yong-Kab
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.2
    • /
    • pp.63-68
    • /
    • 2017
  • In this paper, Distance recognition measurement using distance calculation correction algorithm, was realization through LED dimming control. The calculation values for the RSSI average filtering and the RSSI feedback filtering were calculated and applied to reduce the error of the RSSI value measured from a long distance. It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements. A distance calculation correction algorithm to improve the accuracy was applied, which confirmed that as the distance increases, the range of errors decreases. In conclusion, unstable signals were corrected using the RSSI measurement result filtering, and the distance calculation correction algorithm was applied and performed to reduce the range of errors. In addition, RGB colors were implemented by LED to indicate the distance determination and the signal stability.

The Combined Effect of Heat and Gamma Irradiation on the Inactivation of Selected Microorganisms Associated with Food Hygiene (식품위생관계 미생물에 대한 가열처리와 감마선조사의 병용효과)

  • 권오진;변명우
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.5
    • /
    • pp.804-809
    • /
    • 1996
  • The bactericidal effectiveness of radiation alone or in combination with heat against 8 strains associated with food hygiene were evaluated. In the case of radiation alone, D$_{10}$ values of micro-organisms were 0.14~0.48 kGy, and inactivation factors were 4.54~21.43 at the doses of 2~3 kGy. Escherichia coli was the most sensitive among the tested strains, resulting in a D$_{10}$ value of 0.14 kGy. D$_{min}$ values of tile strains were 10~40 minutes at $50\pm1^{\circ}C,$ and 5~10 minutes at $60\pm1^{\circ}C.$ Combination with heat and radiation showed D$_{10}$ values of 0.04~0.31. Inactivation factors were 6.45~75 at the doses of 2 to 3 kGy. Therefore, heat treatment prior to irradiation significantly increased mactivation rate by increasing radiation sensitivity of microorganisms.ganisms.

  • PDF

Hematological and Blood Chemical Values for Elks Raised in Korea (국내 사육 Elk(Cervus canadensis)의 혈액학치와 혈액화학치)

  • 금창훈;장종식;이현범
    • Journal of Veterinary Clinics
    • /
    • v.15 no.1
    • /
    • pp.162-170
    • /
    • 1998
  • Present experiments were undertaken in order to determine the normal hematological and blood chemical values of elks raised in Korea. Blood samples were collected from 22 healthy adult (5~10 years old) male elks raised in Kyung-pook prefecture and examined for 9 hematological and 15 blood chemical parameters using automatic blood cell counter and automatic blood chemical analyzer. The mean hematological values were determined as PCV : 34.23%, RBC count : $6.70{\times}10^{6}/{\mu}l, Hb : 12.15g/61, WBC count : 3.17{\times}10^{3}/{\mu}l$, neutrophil : 54.09%, eosinophil : 12.27%, Iymphocyte : 28.86%, monocyte : 5.23%, and platelet : $39.94$\times$10^{5}/{\mu}l$

  • PDF