• 제목/요약/키워드: D-axis control

검색결과 428건 처리시간 0.029초

농형 유도발전기를 이용한 계통 연계형 풍력발전 시스템 (Grid-Connected Wind Power Generation System Using Cage-Type Induction Generators)

  • 김형균;;이동춘;석줄기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.73-76
    • /
    • 2003
  • This paper proposes a maximum output power control of grid-connected wind power generation system using cage-type induction generators. For generator control, indirect vector control is used, where d-axis current controls the excitation level and q-axis current controls the generator speed. The generated power flows into the utility through the grid-side converter, by which the do link voltage is controlled to be constant and the ac current is controlled in sinusoid and. The generator speed is adjusted according to wind speed for extracting maximum power generation. Experimental results are shown to verify the validity of the proposed scheme.

  • PDF

스텝 모터에 의한 X-Y 평면 구동 제어 시스템 개발 (DEVELOPMENT OF X-Y PLANE DRIVING CONTROL SYSTEM BY STEPPING MOTOR)

  • 이사영;김봉희;박성대;김홍철;김원철;홍일선;우천희;오봉환;이복구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2166-2168
    • /
    • 1998
  • A PWM inverter using power FET is developed to switch the excitation current of 5 phase hybrid stepping motor for the use of driving X, Y table. A micro processor based controller is also developed to control the excitation current switching of X, Y axis stepping motor as well as synchronizing operation of Z-axis servo motor. The developed driving control system is applied to the industrial embroidery sewing machine.

  • PDF

저주파 진동 감쇠를 위한 UPFG의 제어 (Control of UPFG to Reduce Low Frequency Oscillation)

  • 김태현;서장철;문승일;박종근;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.848-850
    • /
    • 1997
  • A control method of UPFC (Unified Power Flow Controller) to reduce low frequency oscillation is proposed. UPFC is modelled by voltage source, which magnitude and phase angle can be controlled. Because there needs some time to change to desired value, d-axis voltage and Q-axis voltage is modeled by 1st order delay. LQG(Linear Quadratic Gaussian) is used. It is shown that low frequency can be damped by control of UPFC effectively.

  • PDF

On-line Parameter Estimation of Interior Permanent Magnet Synchronous Motor using an Extended Kalman Filter

  • Sim, Hyun-Woo;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.600-608
    • /
    • 2014
  • This paper presents estimation of d-axis and q-axis inductance of an interior permanent magnet synchronous motor (IPMSM) by using an extended Kalman filter (EKF). The EKF is widely used for control applications including the motor sensorless control and parameter estimation. The motor parameters can be changed by temperature and air-gap flux. In particular, the variation of the inductance affects torque characteristics like the maximum torque per ampere (MTPA) control. Therefore, by estimating the parameters, it is possible to improve the torque characteristics of the motor. The performance of the proposed estimator is verified by simulations and experimental results based on an 11kW PMSM drive system.

다층퍼셉트론의 정합 근사화에 의한 2차원 영상의 카메라 오차보정 (A 2-D Image Camera Calibration using a Mapping Approximation of Multi-Layer Perceptrons)

  • 이문규;이정화
    • 제어로봇시스템학회논문지
    • /
    • 제4권4호
    • /
    • pp.487-493
    • /
    • 1998
  • Camera calibration is the process of determining the coordinate relationship between a camera image and its real world space. Accurate calibration of a camera is necessary for the applications that involve quantitative measurement of camera images. However, if the camera plane is parallel or near parallel to the calibration board on which 2 dimensional objects are defined(this is called "ill-conditioned"), existing solution procedures are not well applied. In this paper, we propose a neural network-based approach to camera calibration for 2D images formed by a mono-camera or a pair of cameras. Multi-layer perceptrons are developed to transform the coordinates of each image point to the world coordinates. The validity of the approach is tested with data points which cover the whole 2D space concerned. Experimental results for both mono-camera and stereo-camera cases indicate that the proposed approach is comparable to Tsai's method[8]. Especially for the stereo camera case, the approach works better than the Tsai's method as the angle between the camera optical axis and the Z-axis increases. Therefore, we believe the approach could be an alternative solution procedure for the ill -conditioned camera calibration.libration.

  • PDF

Extraction of Geomagnetic Field from KOMSAT-1 Three-Axis Magnetometer Data

  • Hwang, Jong-Sun;Lee, Sun-Ho;Min, Kyung-Duck;Kim, Jeong-Woo
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.242-242
    • /
    • 2002
  • The Earth's magnetic field acquired from KOMPSAT-1's TAM (Three-Axis Magnetometer) between June 19th and 21st 2000 was analyzed. The TAM, one of the KOMPSAT-1's Attitude and Orbit Control Subsystems, plays an important role in determining and controlling the satellite's attitude. This also can provide new insight on the Earth's magnetic field. By transforming the satellite coordinate from ECI to ECEF, spherical coordinate of total magnetic field was achieved. These data were grouped into dusk (ascending) and dawn (descending) data sets, based on their local magnetic times. This partitioning is essential for performing 1-D WCA (Wavenumber Correlation Analysis). Also, this enhances the perception of external fields in the Kompsat-1's TAM magnetic maps that were compiled according to different local. The dusk and dawn data are processed independently and then merged to produce a total field magnetic anomaly map. To extract static and dynamic components, the 1-D and 2-D WCAs were applied to the sub-parallel neighboring tracks and dawn-dusk data sets. The static components were compared with the IGRF, the global spherical harmonic magnetic field model. The static and dynamic components were analyzed in terms of corefield, external, and crustal signals based on their origins.

  • PDF

불확실성 요소를 갖는 3D 크레인 시스템의 강인적응제어 (Robust Adaptive Control of 3D Crane Systems with Uncertainty)

  • 정상철;김동원;이형기;조현철
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.102-108
    • /
    • 2008
  • This paper presents robust and adaptive control method for complicated three dimensional crane systems with uncertain effect. We consider an overhead crane system in which a trolly located on its top is moved to x- and y-axis independently. We first approximate the complicated crane model through linearization approach to simply construct a PD control and then design an adaptive control system for compensating modeling error and control deviation which is feasibly occurred due to system perturbation in practice. An adaptive control scheme is analytically derived using Lyapunov stability theory for a given bound of system perturbation. We accomplish numerical simulation for evaluation of the proposed control system and demonstrate its superiority comparing with the traditional control strategy.

5[kVA]급 3상 능동전력필터를 위한 저가형 제어기 설계 (Design of Low Cost Controller for 5[kVA] 3-Phase Active Power Filter)

  • 이승요;채영민;최해룡;신우석;최규하
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.26-34
    • /
    • 1999
  • 비선형 반도체 전력변화장치의 사용이 급증함에 따라 전원 측에 발생되는 고조파 및 무효전력을 보상하기 위한 능동전력필터에 관한 연구가 많이 이루어져 왔으며 실용화를 위한 노력이 계속 되고 있다. 그러나 수동필터 대비 능동전력필터의 가격이 아직까지는 고가이기 때문에 이의 상용화가 더디게 진전되고 있는 추세이며, 특히 소·중용량의 능동전력필터의 제어를 위하여 디지털 신호 처리용 프로세서인 DSP(digital signal processor)를 사용하는 경우 아직까지 그 가격이 고가이기 때문에 능동필터의 제어가격을 상승시키는 요인으로 작용한다. 한편 능동전력필터의 가격을 낮추기 위해 아날로그 제어기만을 도입하는 경우 제어회로가 너무 복잡해 지고 제어의 유연성이 떨어지는 단점을 수반하게 된다. 본 논문에서는 3상 5[kVA]급 농동전력필터의 저가형 제어기를 구현하기 위해 저가의 원칩 마이크로프로세서인 80C196KC를 사용하영 디지털 제어부를 구성하며 이를 통해 보상전류 성분의 계산 및 직류단 일정 전압제어를 수행하고, 능동필터 시스템의 전류제어를 위하여 아날로글 형태의 제어기인 히스테리시스 제어기를 함께 사용한다. 컴퓨터 시뮬레이션을 통해서 보상 시스템의 특성을 해석하였으며 실험에 의해 능동전력필터의 저가화를 위해 설계된 제어기가 고조파 및 무효전력 보상을 충실히 수행함을 확인하였다.

회전자 위치 추정 PI 제어기를 이용한 비돌극형 PMSM 센서리스 제어 (Sensorless Control of Non-salient PMSM using Rotor Position Tracking PI Controller)

  • 이종건;석줄기;이동춘;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.664-670
    • /
    • 2004
  • This paper presents a new velocity estimation strategy of a non-salient permanent magnet synchronous motor (PMSM) drive without high frequency signal injection or special PWM pattern. This approach is based on the d-axis current regulator output voltage of the drive system that has the information of rotor position error. The rotor velocity can be estimated through a rotor position tracking PI controller that controls the position error to zero. For zero and low speed operation, PI controller gains of rotor position tracking controller have a variable structure according to the estimated rotor velocity. In order to boost the bandwidth of PI controller around zero speed, a loop recovery technique is applied to the control system. The proposed method only requires the flux linkage of permanent magnet and is insensitive to the parameter estimation error and variation. The designers can easily determine the possible operating range with a desired bandwidth and perform the vector control even at low speeds. The experimental results show the satisfactory operation of the proposed sensorless algorithm under rated load conditions.

동기기를 사용한 계통연계형 가변속 풍력발전 시스템의 AC-DC-AC 컨버터 구현 및 제어 (Implementation and Control of AC-DC-AC Power Converter in a Grid-Connected Variable Speed Wind Turbine System with Synchronous Generator)

  • 송승호;김성주;함년근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권12호
    • /
    • pp.609-615
    • /
    • 2005
  • A 30kW electrical power conversion system is developed for a variable speed wind turbine. In the wind energy conversion system(WECS) a synchronous generator with field current excitation converts the mechanical energy into electrical energy. As the voltage and the frequency of the generator output vary according to the wind speed, a 6-bridge diode rectifier and a PWM boost chopper is utilized as an ac-dc converter maintaining the constant dc-link voltage with only single switch control. An input current control algorithm for maximum power generation during the variable speed operation is proposed without any usage of speed sensor. Grid connection type PWM inverter converts dc input power to ac output currents into the grid. The active power to the grid is controlled by q-axis current and the reactive power is controlled by d-axis current with appropriate decoupling. The phase angle of utility voltage is detected using software PLL(Phased Locked Loop) in d-q synchronous reference frame. Experimental results from the test of 30kW prototype wind turbine system show that the generator power can be controlled effectively during the variable speed operation without any speed sensor.