• Title/Summary/Keyword: D-T Generator

Search Result 117, Processing Time 0.038 seconds

Reduction of series transformer voltage variation of voltage disturbance generator (전압변동 발생기의 직렬변압기에 의한 전압변동 개선)

  • Nho, E.C.;Lee, Y.H.;Min, B.H.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Choi, N.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.218-220
    • /
    • 2007
  • A new 3-phase voltage disturbance generator is proposed. The voltage drop of the conventional generator in normal mode can be reduced significantly. The output voltage of the proposed generator is constant in normal mode and the efficiency of the series transformer is improved. The proposed generator has good feature of simple structure, cost effective implementation, high reliability, high efficiency, and easy control. The usefulness of the scheme is verified through simulation and experiments.

  • PDF

Outage and Voltage Unbalance Generator for the Test of Flywheel Energy Storage UPS (플라이휠 저장에너지 UPS의 성능 시험을 위한 순간정전 및 전압불평형 발생기)

  • Kim J. W.;Lee K. S.;Byeon W. Y.;Nho E. C.;Kim I. D.;Chun T. W.;Kim H. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.570-574
    • /
    • 2004
  • This paper deals with a novel 3-phase power quality disturbance generator. The proposed generator can be applied to the performance that of custom power devices. Voltage sag, swell, outage unbalance and phase shift are provided by the generator. The control scheme for the disturbance generation is simple, and hardware setup is cost effective compared with conventional scheme. The operating principle of the generator is described and the usefulness verified through simulation with 10kVA power rating.

  • PDF

Instantaneous Voltage Disturbance Generator for the Performance Test of Dynamic UPS (다이나믹 UPS의 성능시험을 위한 순시전압 변동 발생기)

  • Kim J.W.;Lee K.S.;Byeon W.Y.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1254-1256
    • /
    • 2004
  • This paper deals with a novel 3-phase power quality disturbance generator. The proposed generator can be applied to the performance that of custom power devices. Voltage sag, swell and outage are provided by the generator. The control scheme for the disturbance generation is simple, and hardware setup is cost effective, compared with conventional scheme. The operating principle of the generator is described and the usefulness verified through simulation with 10KVA power rating.

  • PDF

Voltage Disturbance Generator for the Test of Custom Power Devices with Nonlinear Load Characteristics (비선형 부하특성을 갖는 전력품질 개선장치의 성능시험을 위한 전압변동발생기)

  • Park, S.D.;Lee, B.C.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.935-936
    • /
    • 2006
  • This paper deals with a 3-phase voltage disturbance generator. The proposed generator can be used for the performance teat of custom power devices with nonlinear load characteristics as well as linear load. The principle of the voltage sag, swell, outage, and unbalance generation is described. The switching pattern for the SCR thyristors in each mode is analysed to guarantee the system reliability. The validity of the proposed scheme is verified through simulation result.

  • PDF

Analysis of Electromagnetic Field Characteristics of 30 KVA Superconducting Generator Using 3D FEM Program (3차원 유한요소 프로그램을 이용한 30 KVA 초전도발전기의 전자장 특성 해석)

  • Lee, Jong-Hyuk;Shin, Pan-Seok;Lee, Jae-Kun;Park, Do-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.250-253
    • /
    • 1998
  • This paper has proposed a method to analyze a 30 KVA superconducting generator using 3-dimensional FEM program. 3 kinds of 3D formulation methods are employed such as scalar potential in core region, reduced scalar potential in air region and T-${\omega}$ formulation in stator coil region. As results of the simulation, various parameters of the generator have been analyzed like air gap flux density, induced voltage, inductance, etc.

  • PDF

A Coupled Circuit and Field Analysis of a Stand-Alone Permanent-Magnet Synchronous Generator with Inset Rotor

  • Chan T. F.;Yan Lie-Tong;Lai L. L.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.253-257
    • /
    • 2005
  • By using a coupled circuit, time-stepping, two-dimensional finite element method (2-D FEM), the performance of a stand-alone permanent-magnet synchronous generator (PMSG) with inset rotor can be computed without involving the classical two-axis model. The effects of interpolar air gap length and armature resistance on the load characteristics are investigated. It is shown that the interpolar flux density, and hence the amount of voltage compensation, is affected by magnetic saturation. Validity of the coupled circuit and field analysis is confirmed by experiments on a prototype generator. The machine exhibits an approximately level load characteristic when it is supplying an isolated unity-power-factor load.

Output Characteristic Analysis of Outage and Phase Jump Generator for Microgrid (마이크로그리드용 순간정전 및 위상급변 발생기의 출력특성 해석)

  • Lee, Y.H.;Min, B.H.;Jung, J.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.106-108
    • /
    • 2008
  • This paper describes output characteristics analysis of outage and phase jump generator for microgrid. The outage and phase jump can be generated with 3-phase voltage disturbance generator. As soon as the outage occurs the STS(Solid Transfer Switch)s are switched off. At the beginning of the outage the PCS is required to limit the reverse current within the rated PCS output current. In case of phase jump the PCS output voltage phase should be adjusted. The generator output characteristics are analysed through simulation.

  • PDF

Development and Usefulness Evaluation of Simulator for Educational Radiation Generator (방사선발생장치 교육을 위한 시뮬레이터의 개발과 유용성 평가)

  • Seo, Jeong-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.591-597
    • /
    • 2021
  • In the present study, we developed virtual reality education contents for radiation generator on radiation education field. The radiation generator was divided by module and even the X-ray exposure part was manufactured in detail for designing 3D models. The mechanical details of the X-ray exposure part, the function of adjusting field size of the X-ray, the function of moving the exposure part, and the demonstrating the principle of the X-ray tube were applied. For developing VR contents, the Unreal Engine was used. To evaluate the usefulness of virtual reality content, we used t-test by SPSS. The group used the simulator showed significantly higher levels of understanding of X-ray generation, X-ray irradiation unit composition, irradiation field size adjustment, irradiation unit position adjustment, and overall composition and function. We believe that this VR contents will be used well with radiation safe environment.

Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator (수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가)

  • Hwang, D.H.;Kim, J.B.;Kim, Y.J.;Park, M.S.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF