• Title/Summary/Keyword: D-T Generator

Search Result 117, Processing Time 0.024 seconds

Analysis of the Electromagnetic Clutch for Emergency Power Generator (비상발전기용 전자클러치의 자계해석)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.111-116
    • /
    • 2011
  • This paper deals with the electromagnetic clutch which stop the generator at emergency by using the engine power of generator. The electromagnetic field was analyzed using Flux-2d program with different conditions : voltage, air gap, coil locations. As a result, the maximum magnetic flux density of electromagnetic clutch occurred between the coil and wheel : 0.27[T], 0.41[T] at 12[V], 24[V]. The maximum flux density was at the center location of the coil.

Cheju Hanlim S/T Model Parameter Determination and Assessment of Voltage Control Loop on the Characteristic Tests of Generator/Excitation System (발전기/제어계 특성시험을 통한 제주한림 S/T 모델정수 결정과 전압제어특성 평가)

  • Kim, D.J.;Moon, Y.H.;Lee, K.J.;Yun, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.147-149
    • /
    • 1999
  • This paper deals with the determination of generator/exciter model parameters for a Cheju Hanlim steam turbine unit. Using the recorded data from the generator characteristic tests, the model parameters have been derived and verified by comparing the simulation results and recorded data. In addition to it, the closed-loop performance of voltage control on no-load condition has been assessed in the frequency domain by taking advantage of derived generator/exciter model parameters.

  • PDF

MEASUREMENT OF THE D-D NEUTRON GENERATION RATE BY PROTON COUNTING

  • Kim, In-Jung;Jung, Nam-Suk;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.299-304
    • /
    • 2008
  • A detection system was set up to measure the neutron generation rate of a recently developed D-D neutron generator. The system is composed of a Si detector, He-3 detector, and electronics for pulse height analysis. The neutron generation rate was measured by counting protons using the Si detector, and the data was crosschecked by counting neutrons with the He-3 detector. The efficiencies of the Si and He-3 detectors were calibrated independently by using a standard alpha particle source $^{241}Am$ and a bare isotopic neutron source $^{252}Cf$, respectively. The effect of the cross-sectional difference between the D(d,p)T and $D(d,n)^3He$ reactions was evaluated for the case of a thick target. The neutron generation rate was theoretically corrected for the anisotropic emission of protons and neutrons in the D-D reactions. The attenuations of neutron on the path to the He-3 detector by the target assembly and vacuum flange of the neutron generator were considered by the Monte Carlo method using the MCNP 4C2 code. As a result, the neutron generation rate based on the Si detector measurement was determined with a relative uncertainty of ${\pm}5%$, and the two rates measured by both detectors corroborated within 20%.

Power Quality Disturance Generator with Phase Jump Function (위상 급변 기능이 있는 전력품질 외란 발생기)

  • Lee B.C.;Choi S.H.;Paeng S.H.;Nho E.C.;Kim I.D.;Chun T.W.;Kim H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.96-100
    • /
    • 2004
  • This paper deals with power quality disturbance generator with phase jump function. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The phase jump operating principle of the generator is described and analysed. The control scheme of the disturbance generator is simple and hardware setup is cost effective compared with the conventional scheme. The usefulness of the generator is verified through simulation and experimental results.

  • PDF

Development of On-tine Partial Discharge Monitoring System for High-Voltage Motor Stator Windings (고압 전동기 고정자 권선의 운전중 절연감시 시스템 개발)

  • Hwang, D.H.;Sim, W.Y.;Park, D.Y.;Gang, Dong-Sik;Kim, Y.J.;Song, S.O.;Kim, H.D.
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.224-226
    • /
    • 2001
  • In this paper, a novel high-voltage motor monitoring system (HVMMS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, EMC (Epoxy-Mica Coupler) is used for PD measurement PD signals are continuously measured and digitized with a peak-hold A/D converter to build the database of the high-voltage motor's insulation condition. Also, this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

Open Die Forging of Steel Forgings for the Large Tubesheet (대형 튜브시트 단강품의 자유단조)

  • Kim D. K.;Kim J. C.;Kim Y. D.;Kim D. Y.;Kim J. T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.10a
    • /
    • pp.333-337
    • /
    • 2004
  • Steam Generator is one of the most important structural part of nuclear power plant. It is manufactured by various steel forgings such as shell, head, torus and tubesheet. These steel forgings have been made by open die forging process. After steel melting and ingot making, open die forging has been carried out to get a good quality which means high soundness and homogeniety of the steel forgings by using high capacity hydraulic press. This paper introduced the open die forging process and manufacturing experience of large tubesheet forgings which will be used for the steam generator of 1,400MW nuclear power plant.

  • PDF

Power Quality Disturbance Generator with Arbitrary Phase Jump and Voltage Control for Nonlinear Load (비선형 부하를 위한 임의의 위상 급변 및 전압제어가 가능한 전력품질 외란 발생기)

  • Park, P.S.;Nho, E.C.;Kim, I.D.;Choi, N.S.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.146-148
    • /
    • 2006
  • This paper deals with a simple structured power quality disturbance generator for nonlinear load devices. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The improving phase jump operating principle of the generator is described and analysed. The usefulness of the generator is verified through simulation.

  • PDF

A simple structured voltage disturbance generator for power quality improving devices (전력품질 개선장치를 위한 간단한 구조의 전압변동 발생기)

  • Lee, B.C.;Choi, S.H.;Paeng, S.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.552-554
    • /
    • 2005
  • This paper deals with a simple structured voltage disturbance generator for power quality improving devices. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The improving phase jump operating principle of the generator is described and analysed. The usefulness of the generator is verified through simulation.

  • PDF

A Novel Control Scheme for T-Type Three-Level SSG Converters Using Adaptive PR Controller with a Variable Frequency Resonant PLL

  • Lin, Zhenjun;Huang, Shenghua;Wan, Shanming
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1176-1189
    • /
    • 2016
  • In this paper, a novel quasi-direct power control (Q-DPC) scheme based on a resonant frequency adaptive proportional-resonant (PR) current controller with a variable frequency resonant phase locked loop (RPLL) is proposed, which can achieve a fast power response with a unity power factor. It can also adapt to variations of the generator frequency in T-type Three-level shaft synchronous generator (SSG) converters. The PR controller under the static α-β frame is designed to track ac signals and to avert the strong cross coupling under the rotating d-q frame. The fundamental frequency can be precisely acquired by a RPLL from the generator terminal voltage which is distorted by harmonics. Thus, the resonant frequency of the PR controller can be confirmed exactly with optimized performance. Based on an instantaneous power balance, the load power feed-forward is added to the power command to improve the anti-disturbance performance of the dc-link. Simulations based on MATLAB/Simulink and experimental results obtained from a 75kW prototype validate the correctness and effectiveness of the proposed control scheme.

CHARACTERIZATIONS OF STABILITY OF ABSTRACT DYNAMIC EQUATIONS ON TIME SCALES

  • Hamza, Alaa E.;Oraby, Karima M.
    • Communications of the Korean Mathematical Society
    • /
    • v.34 no.1
    • /
    • pp.185-202
    • /
    • 2019
  • In this paper, we investigate many types of stability, like (uniform stability, exponential stability and h-stability) of the first order dynamic equations of the form $$\{u^{\Delta}(t)=Au(t)+f(t),\;\;t{\in}{\mathbb{T}},\;t>t_0\\u(t_0)=x{\in}D(A),$$ and $$\{u^{\Delta}(t)=Au(t)+f(t,u),\;\;t{\in}{\mathbb{T}},\;t>t_0\\u(t_0)=x{\in}D(A),$$ in terms of the stability of the homogeneous equation $$\{u^{\Delta}(t)=Au(t),\;\;t{\in}{\mathbb{T}},\;t>t_0\\u(t_0)=x{\in}D(A),$$ where f is rd-continuous in $t{\in}{\mathbb{T}}$ and with values in a Banach space X, with f(t, 0) = 0, and A is the generator of a $C_0$-semigroup $\{T(t):t{\in}{\mathbb{T}}\}{\subset}L(X)$, the space of all bounded linear operators from X into itself. Here D(A) is the domain of A and ${\mathbb{T}}{\subseteq}{\mathbb{R}}^{{\geq}0}$ is a time scale which is an additive semigroup with property that $a-b{\in}{\mathbb{T}}$ for any $a,b{\in}{\mathbb{T}}$ such that a > b. Finally, we give illustrative examples.