• Title/Summary/Keyword: D factor

Search Result 6,458, Processing Time 0.034 seconds

An Analysis of the Antenna Height Gain Factor in Microcell Environment (마이크로 셀 환경에서의 안테나 높이 이득 해석)

  • 김병옥;하덕호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.6
    • /
    • pp.551-557
    • /
    • 1997
  • In mobile radio environment, it is well known that the base station antenna height gain factor is 6 dB / octave. But the mobile radio environment is not simple and affected by the terrain contour or the man-made structures, so the antenna height gain factor varies due to the propagation conditions. This paper represents the received signal power gain due to the base station antenna height in the microcell environment on the basis of the flat terrain and sloping terrain model. The gain point which shows the antenna height gain is derived in this paper.

  • PDF

Study of ground vibration induced by high-speed trains moving on multi-span bridges

  • Ju, S.H.
    • Structural Engineering and Mechanics
    • /
    • v.59 no.2
    • /
    • pp.277-290
    • /
    • 2016
  • This paper investigates the ground vibration induced by high-speed trains moving on multi-span continuous bridges. The dynamic impact factor of multi-span continuous bridges under trainloads was first determined in the parametric study, which shows that the dynamic impact factor will be large when the first bridge vertical natural frequency is equal to the trainload dominant frequencies, nV/D, where n is a positive integer, V is the train speed, and D is the train carriage interval. In addition, more continuous spans will produce smaller dynamic impact factors at this resonance condition. Based on the results of three-dimensional finite element analyses using the soil-structure interaction for realistic high-speed railway bridges, we suggest that the bridge span be set at 1.4 to 1.5 times the carriage interval for simply supported bridges. If not, the use of four or more-than-four-span continuous bridges is suggested to reduce the train-induced vibration. This study also indicates that the vibration in the train is major generated from the rail irregularities and that from the bridge deformation is not dominant.

A study on the improvement in Q-factor chracteristics of VCO resonance part (VCO 공진부의 Q-factor 특성향상에 관한 연구)

  • Lee, Hyun-Jong;Kim, In-Sung;Min, Bok-Gi;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1506-1508
    • /
    • 2005
  • VCO(voltage controlled oscillator) using mobile communication device decides direct characteristics as parts that affect important in stable oscillation and distortion characteristics of system. VCO used 900 MHz band was designed by the transformation of Colpitts circuit form use ADS that consider Q-factor to minimize phase noise. VCO manufactured together evaluation board and voltage control oscillator to FR-4 PCB. VCO experimented chracteristics after control through resonance department tuning. In our research, the designed VCO has 15.5 dBm output level at the bias condition of 6V and 10mA and the operating frequency range of 917 MHz$\sim$937 MHz band. Phase noise is -98.28 dBc/Hz at 1 MHz frequency offset from the carrier.

  • PDF

Characteristics of Pressure Drops in Square Channels with Twisted Tape Inserts plus Axial Interrupted Ribs (테이프와 거칠기가 설치된 사각 채널의 압력강하 특성)

  • Ahn, S.W.;Bae, S.T.;Kang, H.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.38-42
    • /
    • 2006
  • Pressure drops and friction factors in square channels with twisted tape inserts plus axial interrupted ribs are investigated. Tests are performed for Reynolds numbers ranging from 8,900 to 29,000. The rib height-to-channel hydraulic diameter, $e/D_h$, is kept at 0.057 and test section length-to-hydraulic diameter, $L/D_h$ is 30. The pressure drops and friction factor values are enhanced with axial interrupted ribs and twisted tape inserts. Square channels with twisted tape inserts plus axial interrupted ribs show the greatest pressure loss penalty in the present work. Friction factor data obtained for the square channel with twisted tape inserts plus axial interrupted ribs are less than those in the past publications for circular tubes with axial interrupted ribs and twisted tape inserts.

  • PDF

Improvement and Validation of Convective Rainfall Rate Retrieved from Visible and Infrared Image Bands of the COMS Satellite (COMS 위성의 가시 및 적외 영상 채널로부터 복원된 대류운의 강우강도 향상과 검증)

  • Moon, Yun Seob;Lee, Kangyeol
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.420-433
    • /
    • 2016
  • The purpose of this study is to improve the calibration matrixes of 2-D and 3-D convective rainfall rates (CRR) using the brightness temperature of the infrared $10.8{\mu}m$ channel (IR), the difference of brightness temperatures between infrared $10.8{\mu}m$ and vapor $6.7{\mu}m$ channels (IR-WV), and the normalized reflectance of the visible channel (VIS) from the COMS satellite and rainfall rate from the weather radar for the period of 75 rainy days from April 22, 2011 to October 22, 2011 in Korea. Especially, the rainfall rate data of the weather radar are used to validate the new 2-D and 3-DCRR calibration matrixes suitable for the Korean peninsula for the period of 24 rainy days in 2011. The 2D and 3D calibration matrixes provide the basic and maximum CRR values ($mm\;h^{-1}$) by multiplying the rain probability matrix, which is calculated by using the number of rainy and no-rainy pixels with associated 2-D (IR, IR-WV) and 3-D (IR, IR-WV, VIS) matrixes, by the mean and maximum rainfall rate matrixes, respectively, which is calculated by dividing the accumulated rainfall rate by the number of rainy pixels and by the product of the maximum rain rate for the calibration period by the number of rain occurrences. Finally, new 2-D and 3-D CRR calibration matrixes are obtained experimentally from the regression analysis of both basic and maximum rainfall rate matrixes. As a result, an area of rainfall rate more than 10 mm/h is magnified in the new ones as well as CRR is shown in lower class ranges in matrixes between IR brightness temperature and IR-WV brightness temperature difference than the existing ones. Accuracy and categorical statistics are computed for the data of CRR events occurred during the given period. The mean error (ME), mean absolute error (MAE), and root mean squire error (RMSE) in new 2-D and 3-D CRR calibrations led to smaller than in the existing ones, where false alarm ratio had decreased, probability of detection had increased a bit, and critical success index scores had improved. To take into account the strong rainfall rate in the weather events such as thunderstorms and typhoon, a moisture correction factor is corrected. This factor is defined as the product of the total precipitable waterby the relative humidity (PW RH), a mean value between surface and 500 hPa level, obtained from a numerical model or the COMS retrieval data. In this study, when the IR cloud top brightness temperature is lower than 210 K and the relative humidity is greater than 40%, the moisture correction factor is empirically scaled from 1.0 to 2.0 basing on PW RH values. Consequently, in applying to this factor in new 2D and 2D CRR calibrations, the ME, MAE, and RMSE are smaller than the new ones.

The Effects of the Computer Aided Innovation Capabilities on the R&D Capabilities: Focusing on the SMEs of Korea (Computer Aided Innovation 역량이 연구개발역량에 미치는 효과: 국내 중소기업을 대상으로)

  • Shim, Jae Eok;Byeon, Moo Jang;Moon, Hyo Gon;Oh, Jay In
    • Asia pacific journal of information systems
    • /
    • v.23 no.3
    • /
    • pp.25-53
    • /
    • 2013
  • This study analyzes the effect of Computer Aided Innovation (CAI) to improve R&D Capabilities empirically. Survey was distributed by e-mail and Google Docs, targeting CTO of 235 SMEs. 142 surveys were returned back (rate of return 60.4%) from companies. Survey results from 119 companies (83.8%) which are effective samples except no-response, insincere response, estimated value, etc. were used for statistics analysis. Companies with less than 50billion KRW sales of entire researched companies occupy 76.5% in terms of sample traits. Companies with less than 300 employees occupy 83.2%. In terms of the type of company business Partners (called 'partners with big companies' hereunder) who work with big companies for business occupy 68.1%. SMEs based on their own business (called 'independent small companies') appear to occupy 31.9%. The present status of holding IT system according to traits of company business was classified into partners with big companies versus independent SMEs. The present status of ERP is 18.5% to 34.5%. QMS is 11.8% to 9.2%. And PLM (Product Life-cycle Management) is 6.7% to 2.5%. The holding of 3D CAD is 47.1% to 21%. IT system-holding and its application of independent SMEs seemed very vulnerable, compared with partner companies of big companies. This study is comprised of IT infra and IT Utilization as CAI capacity factors which are independent variables. factors of R&D capabilities which are independent variables are organization capability, process capability, HR capability, technology-accumulating capability, and internal/external collaboration capability. The highest average value of variables was 4.24 in organization capability 2. The lowest average value was 3.01 in IT infra which makes users access to data and information in other areas and use them with ease when required during new product development. It seems that the inferior environment of IT infra of general SMEs is reflected in CAI itself. In order to review the validity used to measure variables, Factors have been analyzed. 7 factors which have over 1.0 pure value of their dependent and independent variables were extracted. These factors appear to explain 71.167% in total of total variances. From the result of factor analysis about measurable variables in this study, reliability of each item was checked by Cronbach's Alpha coefficient. All measurable factors at least over 0.611 seemed to acquire reliability. Next, correlation has been done to explain certain phenomenon by correlation analysis between variables. As R&D capabilities factors which are arranged as dependent variables, organization capability, process capability, HR capability, technology-accumulating capability, and internal/external collaboration capability turned out that they acquire significant correlation at 99% reliability level in all variables of IT infra and IT Utilization which are independent variables. In addition, correlation coefficient between each factor is less than 0.8, which proves that the validity of this study judgement has been acquired. The pair with the highest coefficient had 0.628 for IT utilization and technology-accumulating capability. Regression model which can estimate independent variables was used in this study under the hypothesis that there is linear relation between independent variables and dependent variables so as to identify CAI capability's impact factors on R&D. The total explanations of IT infra among CAI capability for independent variables such as organization capability, process capability, human resources capability, technology-accumulating capability, and collaboration capability are 10.3%, 7%, 11.9%, 30.9%, and 10.5% respectively. IT Utilization exposes comprehensively low explanatory capability with 12.4%, 5.9%, 11.1%, 38.9%, and 13.4% for organization capability, process capability, human resources capability, technology-accumulating capability, and collaboration capability respectively. However, both factors of independent variables expose very high explanatory capability relatively for technology-accumulating capability among independent variable. Regression formula which is comprised of independent variables and dependent variables are all significant (P<0.005). The suitability of regression model seems high. When the results of test for dependent variables and independent variables are estimated, the hypothesis of 10 different factors appeared all significant in regression analysis model coefficient (P<0.01) which is estimated to affect in the hypothesis. As a result of liner regression analysis between two independent variables drawn by influence factor analysis for R&D capability and R&D capability. IT infra and IT Utilization which are CAI capability factors has positive correlation to organization capability, process capability, human resources capability, technology-accumulating capability, and collaboration capability with inside and outside which are dependent variables, R&D capability factors. It was identified as a significant factor which affects R&D capability. However, considering adjustable variables, a big gap is found, compared to entire company. First of all, in case of partner companies with big companies, in IT infra as CAI capability, organization capability, process capability, human resources capability, and technology capability out of R&D capacities seems to have positive correlation. However, collaboration capability appeared insignificance. IT utilization which is a CAI capability factor seemed to have positive relation to organization capability, process capability, human resources capability, and internal/external collaboration capability just as those of entire companies. Next, by analyzing independent types of SMEs as an adjustable variable, very different results were found from those of entire companies or partner companies with big companies. First of all, all factors in IT infra except technology-accumulating capability were rejected. IT utilization was rejected except technology-accumulating capability and collaboration capability. Comprehending the above adjustable variables, the following results were drawn in this study. First, in case of big companies or partner companies with big companies, IT infra and IT utilization affect improving R&D Capabilities positively. It was because most of big companies encourage innovation by using IT utilization and IT infra building over certain level to their partner companies. Second, in all companies, IT infra and IT utilization as CAI capability affect improving technology-accumulating capability positively at least as R&D capability factor. The most of factor explanation is low at around 10%. However, technology-accumulating capability is rather high around 25.6% to 38.4%. It was found that CAI capability contributes to technology-accumulating capability highly. Companies shouldn't consider IT infra and IT utilization as a simple product developing tool in R&D section. However, they have to consider to use them as a management innovating strategy tool which proceeds entire-company management innovation centered in new product development. Not only the improvement of technology-accumulating capability in department of R&D. Centered in new product development, it has to be used as original management innovative strategy which proceeds entire company management innovation. It suggests that it can be a method to improve technology-accumulating capability in R&D section and Dynamic capability to acquire sustainable competitive advantage.

The Evaluation Method for Viewing Angle Image Control (VIC) Technology

  • Kwon, Jung-Bum;Park, Seung-Chul;Le, Don-Gyou;Lee, Lim-Soo;Ahn, Byung-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.700-702
    • /
    • 2008
  • A new evaluation method which named 'Security Viewing Angle Factor (SVAF)' was suggested for VIC (Viewing-angle Image Control) technology to quantify a visual hiding performance of LCD. Currently, Contrast Ration (CR) is the general method to evaluate VIC technology. However, CR shows a significant difference when compared with the result of human visual system. Furthermore, a perceptional evaluation method and its conditions were established.

  • PDF

Towards a Structure-Function Relationship for Vascular Endothelial Growth Factor-B (VEGF-B)

  • Scrofani, Sergio D.B.;Nash, Andrew D.
    • Journal of Microbiology and Biotechnology
    • /
    • v.11 no.4
    • /
    • pp.543-551
    • /
    • 2001
  • The vascular endothelial growth factor (VEGF), or VEGF-A, is intimately involved in both physiological and pathological forms of angiogenesis. VEGF-A is now recognized as the founding member of a family of growth factors that has expanded to include VEGF-B, VEGF-C, VEGF-D, VEGF-E, and placental growth factor (PIGF). This family of cytokines binds differentially to at least three receptor tyrosine kinases, however, the extent to which family members other than VEGF-A contribute to physiological and pathological angiogenesis remains unclear. Issues that are of relevance include uncertainty regarding the consequences of signaling through VEGF - RI in particular, and the ability of some family members to heterodimerize, leading to the possibility ofheterodimeric receptor complexes. Structural characterization is one approach that can be used to address these issues, however, the vast majority of previous structure-function studies have only focused on VEGF-A. While these studies may provide some clues regarding the structural basis of the interaction of other family members with their receptors, studies using the ligands themselves are clearly required if highly specific interactions are to be revealed. With the recent progress toward refolding and purifying substantial' quantities of other VEGF family members, such structural studies are now possible. Here, these ~ssues are addressed with a particular emphasis on VEGF-B and its receptors.

  • PDF

Comparative Experiment to Determine the Activation Factor of Lead dioxide by Kinds in Measuring the Concentration of Sulfur oxides in the Atmosphere by $PbO_2$ Cylinder Method (사용시약별로 본 이산화연법에 의한 대기중 황산화물의 비교측정및 자동측정 성적과의 비교)

  • 최덕일
    • Journal of Environmental Health Sciences
    • /
    • v.2 no.1
    • /
    • pp.29-31
    • /
    • 1975
  • This experiment Was carried out under two points of view, from May 1st to the end of 1973. One was the comparative determination of the activation factor of Lead dioxide by kinds in measuring of Sulfur oxides concentration by $PbO_2$ cylinder method, and the other was the comparison that result with the record of auto analyzer. Five measuring sites were selected out of Seoul City. Three kinds of Lead dioxide made in Japan (B,C and D) were compared with Standard $PbO_2$ (A for use in Determination of Sulphur in the atmosphere, purity 99% up) made in British Institution, and monthly measuring was conducted at every sampling site. The recording by auto analyzer (Beckman Model 906-A $SO_2$ Analyzer) was conducted once or twice a month for 24 hours at each sampling site during the same period. And some significant results were obtained. 1. In comparative experiments to determine the activation degree of three kinds of Lead dioxide (B,C and D), the obtained correction factor of B reagent was 1.09, 1.16 in C and 1.30 in D against Standard $PbO_2$ (A). Therefore, it should be in need of standardization or clear statement about the reagents for use, in determination sulfur oxides by $PbO_2$ cylinder method. 2. Generally, the concentration of Sulfur dioxide by wilkins' convertion method from $SO_3$ showed about 20-30% higher than those by Auto analyzer.

  • PDF

Classification of Men's Somatotype According to Body Shape and Size(Part II) -Classification of Side View and Compound of Front and Side View- (남성의 동체부 체형분류(제2보) -측면체형의 분류 및 정면과 측면 체형의 조합-)

  • 정재은;김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.10
    • /
    • pp.1443-1454
    • /
    • 2002
  • The purposes of this study were to classify body type of adult males into several kind of shape and to provide the characteristics of size of each group which has same shape. As the sample, subjects were 1290 males of 20 to 54 year-old. The procedure and results were follows; 1. As the result of the previous reserch, the front line of body was classified in X, H, Y and A types. 2. The principal component analysis was used to obtain the shape factor of the side line of the trunk. 9 factors in the side were extracted. As the result of the cluster analysis of factor scores, the side line of body was classified in 5 types. It was named X, A, Y and H type in the front and S, D1, d, I and D2 type in the side. 3. In order to consider the shape of body as a whole, the body shape of the front and side were compounded. The whole body shapes of adult male were very various, and 6 body shapes, XS, YS, Yd, YI, AD2 and HD1 were selected as the basic types. In each type of body, several groups were classified by size factor, height and chest girth and master size was selected considering appearance frequency.