• Title/Summary/Keyword: D 002

Search Result 480, Processing Time 0.042 seconds

Association of ionized magnesium, total magnesium, gestational age, and intraventricular hemorrhage in preterm babies (미숙아에서 이온화 마그네슘, 총 마그네슘과 재태 연령과의 관계 및 뇌실 내 출혈과의 관계)

  • Kim, Tae-Yeon;Lee, Hyun-Hee;Sung, Tae-Jung
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.10
    • /
    • pp.1140-1146
    • /
    • 2009
  • Purpose:The pathophysiology of magnesium, the second highest common compound in humans, is still unclear, especially in preterm babies. We accessed the association between total magnesium (tMg), ionized Mg (iMg), and gestational age (GA) and that between serum magnesium (sMg) and intraventricular hemorrhage (IVH) in preterm babies. Methods:In all, 119 inborn preterm infants admitted between July 2006 and February 2008 were divided into the IVH group (19) and the control group (100) and were prospectively analyzed. TMg, iMg, pH, total calcium (tCa), and ionized Ca (iCa) levels were determined immediately after delivery or within 3 hours after birth, and their correlation with GA were investigated. Results:TMg was not correlated with GA, tCa, iCa, and pH. IMg was correlated with tMg (r=0.288, P=0.002) and iCa (r=0.212, P=0.021); however, it was not correlated with GA and pH. Mean GA and birth weight were significantly lower (P=0.002) and smaller (P=0.030) in the IVH group. Mean sMg was higher in the IVH group ($2.5{\pm}0.9mg/dL$) than in the control group ($2.1{\pm}0.6mg/dL$) (P=0.021). SMg was a risk factor even after logistic regression analysis (OR, 2.798; 95% C.I., 1.265-6.192; P=0.011). Conclusion:In less than 37-week-old preterm babies, tMg and iMg were similar, regardless of GA. High sMg may be a risk factor for IVH in premature babies, regardless of their exposure to antenatal magnesium.

Comparison between FDG Uptake and Clinicopathologic and Immunohistochemical Parameters in Pre-operative PET/CT Scan of Primary Gastric Carcinoma (원발성 위암 환자의 치료 전 PET/CT 스캔에서 FDG 섭취 정도와 임상병리학적 및 면역조직화학적 지표들과의 비교)

  • Han, Eun-Ji;Choi, Woo-Hee;Chung, Yong-An;Kim, Ki-Jun;Maeng, Lee-So;Sohn, Kyung-Myung;Jung, Hyun-Suk;Sohn, Hyung-Sun;Chung, Soo-Kyo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.1
    • /
    • pp.26-34
    • /
    • 2009
  • Purpose: The purpose of this study was to find out what clinicopathologic or immunohistochemical parameter that may affect FDG uptake of primary tumor in PET/CT scan of the gastric carcinoma patient. Materials and Methods: Eighty-nine patients with stomach cancer who underwent pre-operative FDG PET/CT scans were included. In cases with perceptible FDG uptake in primary tumor, the maximum standardized uptake value (SUVmax) was calculated. The clinicopathologic results such as depth of invasion (T stage), tumor size, lymph node metastasis, tumor differentiation and Lauren's classification and immunohistochemical markers such as Ki-67 index, expression of p53, EGFR, Cathepsin D, c-erb-B2 and COX-2 were reviewed. Results: Nineteen out of 89 gastric carcinomas showed imperceptible FDG uptake on PET/CT images. In cases with perceptible FDG uptake in primary tumor, SUVmax was significantly higher in T2, T3 and T4 tumors than T1 tumors ($5.8{\pm}3.1$ vs. $3.7{\pm}2.1$, p=0.002). SUVmax of large tumors (above or equal to 3 cm) was also significantly higher than SUVmax of small ones (less than 3 cm) ($5.7{\pm}3.2$ vs. $3.7{\pm}2.0$, p=0.002). The intestinal types of gastric carcinomas according to Lauren showed higher FDG uptake compared to the non-intestinal types ($5.4{\pm}2.8$ vs. $3.7{\pm}1.3$, p=0.003). SUVmax between p53 positive group and negative group was significantly different ($6.0{\pm}2.8$ vs. $4.4{\pm}3.0$, p=0.035). No significant difference was found in presence of LN metastasis, tumor differentiation, Ki-67 index, and expression of EGFR, Cathepsin D, c-erb-B2 and COX-2. Conclusion: T stage of gastric carcinoma influenced the detectability of gastric cancer on FDG PET PET/CT scan. When gastric carcinoma was perceptible on PET/CT scan, T stage, size of primary tumor, Lauren's classification and p53 expression were related to degree of FDG uptake in primary tumor.

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

Vitamin D status and its association with cardiometabolic risk factors in Korean adults based on a 2008-2010 Korean National Health and Nutrition Examination Survey

  • Chung, Ji-Youn;Hong, Sung-Ho
    • Nutrition Research and Practice
    • /
    • v.7 no.6
    • /
    • pp.495-502
    • /
    • 2013
  • Recent studies suggest that vitamin D deficiency and cardiometabolic disorders are becoming increasingly more prevalent across multiple populations. However, there is a lack of comprehensive data for Korean adults. We investigated the vitamin D status, the prevalence of vitamin D deficiency and its association with metabolic syndrome (MS) risk in Korean adults aged 20 years or older. The study subjects (n = 18,305) were individuals who participated in the Korean National Health Examination and Nutrition Survey (KNHANES) in 2008-2010. Vitamin D status (25-hydroxyvitamin D [25(OH)D]) was categorized as < 20, 21-29, and ${\geq}$ 30 ng/mL, which are the cut-off points for deficiency, insufficiency and normal limits. A wide variety of cardiometabolic risk factors were compared according to the vitamin D status. Vitamin D deficiency was found in 53.9% of men and 70.5% of women. Mean BMI, systolic BP, HbA1c and low density lipoprotein cholesterol (LDL-C) were highest in the vitamin D deficiency group in both genders. Further, the MS was most prevalent in the vitamin D deficiency group in both genders (12.3%, P = 0.002 in men and 9.2%, P < 0.001 in women). Compared to the vitamin D normal group, the adjusted odds ratio (ORs) (95% confidence interval [95% CI]) for MS in the vitamin D deficiency group were 1.46 (1.05-2.02) in men and 1.60 (1.21-2.11) in women, after adjusting for confounding variables. In conclusion, Vitamin D deficiency is a very common health problem in Korean adults and is independently associated with the increasing risk of MS.

A Comparative study on Perceived Importance and Frequency of Core Nursing Skills between General and Special wards (일반병동과 특수병동의 핵심기본간호술에 대한 중요성인식과 수행 빈도 비교)

  • Chang, Eun-Hee;Mo, Moon-Hee;Choi, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1264-1272
    • /
    • 2015
  • This study was performed to compare the perceived importance and performance frequency of the core nursing skills between general and special department. Subjects were 182 nurses who work on the hospital. Data was collected using items made by Korean accreditation board of nursing education and analyzed by frequency, mean and t-test. There were differences of importance and frequencies about nursing core skill between general and special wards. Core nursing skills of general wards were higher importance on intradermal injection(p=.011), transfusion(p=.028), simple catheterization(p=.047), cleansing enema(p=<.001), preoperative and postoperative care(p=.035), management administration(p=.027) and oxygenation with cannular(p=.002) than special wards. Actual performance frequency core nursing skills of general wards were higher similar on transfusion(p=.002), intermittent tube feeding(p=.032), simple catheterization(p=<.001), cleansing enema(p=<.001), preoperative care(p=.001), postoperative care(p=<.001), management administration(p=.001), protection equipment for quarantine room and waste disposal(p=.021), oxygenation with cannular(p=<.001) than special wards. It is needed to develop efficient and sequential program to learning the nursing core skills for nursing students.

Association of Airflow Limitation and COPD Composite Index with Peripheral Oxygen Saturation in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환자에서 기류제한 및 COPD 복합지수와 말초산소포화도의 연관성)

  • Jong Seong Lee;Jae Hoon Shin;Jin Ee Baek;Hyerim Son;Byung-soon Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.57-66
    • /
    • 2024
  • Objective: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that is only partly reversible, inflammation in the airways, and systemic effects. This study aimed to investigate the association between low peripheral oxygen saturation levels (SpO2), and composite indices predicting death in male patients with (COPD). Method: A total of 140 participants with post-bronchodilator FEV1/FVC ratio less than 0.7 were included. Three composite indices (ADO, DOSE, BODEx) were calculated using six variables such as age (A), airflow obstruction (O), body mass index (B), dyspnea (D), exacerbation history (E or Ex), and smoking status (S). Severity of airflow limitation was classified according to Global Initiative for Obstructive Lung Disease (GOLD) guidelines. SpO2 was measured by pulse oximetry, and anemia and iron deficiency were assessed based on blood hemoglobin levels and serum markers such as ferritin, transferrin saturation, or soluble transferrin receptor. Results: Participants with low SpO2 (<95%) showed significantly lower levels of %FEV1 predicted (p=0.020) and %FEV1/FVC ratio (p=0.002) compared to those with normal SpO2 levels. The mMRC dyspnea scale (p<0.001) and GOLD grade (p=0.002) showed a significant increase in the low SpO2 group. Receiver Operating Characteristic analysis revealed higher area under the curve for %FEV1 (p=0.020), %FEV1/FVC(p=0.002), mMRC dyspnea scale (p=0.001), GOLD grade (p=0.010), ADO (p=0.004), DOSE (p=0.002), and BODEx (p=0.011) in the low SpO2 group. Conclusion: These results suggest that low SpO2 levels are related to increased airflow limitation and the composite indices of COPD.

Oscillator Design and Fabrication using a Miniatured Hairpin Resonator

  • Kim, Jang-Gu;Han, Sok-Kyun;Park, Hyung-Ha
    • Journal of Navigation and Port Research
    • /
    • v.28 no.4
    • /
    • pp.293-297
    • /
    • 2004
  • In this papers, an S-band oscillator of the low phase noise property using a miniaturized micro-strip hairpin shaped ring resonator is presented The substrate has a dielectric constant $\epsilon_\gamma$=3.5, a thickness h=0.508 mm, and loss tangent $tan\delta$=0.002. A designed and fabricated oscillator shows low phase noise performance of 99. 71 dBc/Hz at 100 KHz offset frequency and of output power 19.584 dBm at center frequency 2.450 GHz. This circuit was fabricated with hybrid technique, but can be fully compatible with the MMIC due to its entirely planar structure.

Fermented ginseng, GBCK25, ameliorates hemodynamic function on experimentally induced myocardial injury

  • Aravinthan, Adithan;Antonisamy, Paulrayer;Kim, Bumseok;Kim, Nam Soo;Shin, Dong Gyu;Seo, Jeong Hun;Kim, Jong-Hoon
    • Journal of Ginseng Research
    • /
    • v.40 no.4
    • /
    • pp.462-465
    • /
    • 2016
  • In the present study, we investigated whether treatment with GBCK25 facilitated the recovery of hemodynamic parameters, left ventricle systolic pressure, left ventricular developed pressure, and electrocardiographic changes. GBCK25 significantly prevented the decrease in hemodynamic parameters and ameliorated the electrocardiographic abnormality. These results indicate that GBCK25 has distinct cardioprotective effects in rat heart.

Package-Platformed Linear/Circular Polarization Reconfigurable Antenna Using an Integrated Silicon RF MEMS Switch

  • Hyeon, Ik-Jae;Jung, Tony J.;Lim, Sung-Joon;Baek, Chang-Wook
    • ETRI Journal
    • /
    • v.33 no.5
    • /
    • pp.802-805
    • /
    • 2011
  • This letter presents a K-band polarization reconfigurable antenna integrated with a silicon radio frequency MEMS switch into the form of a compact package. The proposed antenna can change its state from linear polarization (LP) to circular polarization (CP) by actuating the MEMS switch, which controls the configuration of the coupling ring slot. Low-loss quartz is used for a radiating patch substrate and at the same time for a packaging lid by stacking it onto the MEMS substrate, which can increase the system integrity. The fabricated antenna shows broadband impedance matching and exhibits high axial ratios better than 15 dB in the LP and small axial ratios in the CP, with a minimum value of 0.002 dB at 20.8 GHz in the K-band.

Broadband Stacked Patch Antenna with Low VSWR and Low Cross-Polarization

  • Wang, Zhongbao;Fang, Shaojun;Fu, Shiqiang
    • ETRI Journal
    • /
    • v.32 no.4
    • /
    • pp.618-621
    • /
    • 2010
  • A low cross-polarization broadband stacked patch antenna is proposed. By means of the stacked patch configuration and probe-fed strip feed technique, the VSWR 1.2:1 bandwidth of the patch antenna is enhanced to 22% from 804 MHz to 1,002 MHz, which outperforms the other available patch antennas (<10%). Furthermore, the antenna has a cross-polarization level of less than -20 dB and a gain level of about 9 dBi across the operating bandwidth. Simulation results are compared with the measurements, and a good agreement is observed.