The Preparation and Property of Carbon Foams from Carbon Black Embedded Pitch Using PU Template (카본블랙이 내첨된 핏치로부터 폴리우레탄 조공제를 이용한 탄소 폼의 제조 및 특성)

  • Lee, Sangmin;Kim, Ji-Hyun;Jeong, Euigyung;Lee, Young-Seak
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.268-273
    • /
    • 2016
  • To improve mechanical strength of carbon foams, the carbon black (CB) added carbon foams were fabricated by impregnating different contents of carbon black (CB) and mesophase pitch using polyvinyl alcohol (PVA) solution into polyurethane foam and being followed by heat treatment. The cell wall-thicknesses of carbon foams were controlled by adding amounts of CB, and it was confirmed that the compressive strength of carbon foams was increased as increasing cell wall-thickness. The compressive strength had the highest value of $0.22{\pm}0.05MPa$ with the highest bulk density of $0.44g/cm^3$ when adding 5 wt% CB in carbon foam. However, the thermal conductivity was decreased by adding CB in carbon foam. The results indicated that the thermal conductivities of carbon foams were reduced by increased interlayer spacing ($d_{002}$) with the addition of CB in carbon foams.

Image Sticking Evaluation Methods for OLED TV Applications

  • Lee, Hun-Jung;Choi, Dong-Wook;Lee, Eun-Jung;Kim, Su-Young;Shin, Mi-Ok;Yang, Sun-A;Lee, Seung-Bae;Lee, Han-Yong;Berkeley, Brian H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1077-1080
    • /
    • 2009
  • In this paper, we propose a new method for measuring image sticking of an OLED display using a human visual test. We determined that the perceptual image sticking threshold is 2% of luminance difference at 200 nits and 1% at 100 nits, respectively. Color shift must also be considered when evaluating image sticking, as a ${\Delta}$(u', v') shift of just over 0.002 can be recognized regardless of background brightness. Perception of image sticking is affected by the background level, test pattern, and ambient illumination conditions. The evaluation standard must consider both luminance variation and color shift simultaneously.

  • PDF

Thermal Behavior and Crystallographic Characteristics of an Epitaxial C49-$TiSi_2$ Phase Formed in the Si (001) Substrate by $N_2$Treatment (Si (001) 기판에서 $N_2$처리에 의해 형성된 에피택셜 C49-$TiSi_2$상의 열적 거동과 결정학적 특성에 관한 연구)

  • Yang, Jun-Mo;Lee, Wan-Gyu;Park, Tae-Soo;Lee, Tae-Kwon;Kim, Joong-Jung;Kim, Weon;Kim, Ho-Joung;Park, Ju-Chul;Lee, Soun-Young
    • Korean Journal of Materials Research
    • /
    • v.11 no.2
    • /
    • pp.88-93
    • /
    • 2001
  • The thermal behavior and the crystallographic characteristics of an epitaxial $C49-TiSi_2$ island formed in a Si (001) substrate by $N_2$, treatment were investigated by X-ray diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM). It was found from the analyzed results that the epitaxial $C49-TiSi_2$ was thermally stable even at high temperature of $1000^{\circ}C$ therefore did not transform into the C54-stable phase and did not deform morphologically. HRTEM results clearly showed that the epitaxial $TiSi_2$ phase and Si have the orientation relationship of (060)[001]$TiSi_2$//(002)[110]Si, and the lattice strain energy at the interface was mostly relaxed by the formation of misfit dislocations. Furthermore, the mechanism on the formation of the epitaxial $_C49-TiSi2$ in Si and stacking faults lying on the (020) plane of the C49 Phase were discussed through the analysis of the HRTEM image and the atomic modeling.

  • PDF

Heavy Metals in Fishery Products, Sold at Fish Markets in Seoul (서울시내 수산시장에서 유통되고 있는 수산물의 비소(As), 카드뮴(Cd) 및 납(Plb)의 함량)

  • 차영섭;함희진;이재인;이정자
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.4
    • /
    • pp.315-323
    • /
    • 2001
  • This study was concentrated that the contents of heavy metals were estimated from 782 samples of sold fisheries in Seoul(33 species in fishes, 15 in bivalves, 12 in crustaceans and 10 in others) by Atomic Absorption Spectrometer. The contents of As, Cd and Pb [minimum~maximum (mean)] were N.D.~0.162 mg/kg(0.021),0.001~0.120 mg/kg(0.014) and 0.015~0.499 mg/kg(0.111) in fishes, 0.003~0.311 mg/kg(0.052), N.D.~1.905 mg/kg(0.182) and 0.013~0.462 mg/kg(0.138) in bivalves, N.D.~0.328 mg/kg(0.042), 0.002~1.113mg/kg(0.079) and 0.006~-.510 mg/kg(0.109) in crustaceans, N.D. ~0.181 mg/kg(0.024), 0.001~0.214 mg/kg(0.033) and 0.010~0.877 mg/kg(0.118) in others respectively, bivalves were the highest than others. The average weekly intakes of three metals from sold fisheries took about 1.4~26.4% of PTWI (provisional tolerable weekly intakes) that FAO/WHO Joint Food Additive and Contaminants Committee had set to evaluate their safety.

  • PDF

Meta-Analysis of the Association between H63D and C282Y Polymorphisms in HFE and Cancer Risk

  • Zhang, Meng;Xiong, Hu;Fang, Lu;Lu, Wei;Wu, Xun;Wang, Yong-Qiang;Cai, Zhi-Ming;Wu, Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.11
    • /
    • pp.4633-4639
    • /
    • 2015
  • Background: Previous studies suggested that the H63D and C282Y polymorphisms in the HFE genes were susceptible to many cancer types, nevertheless, the present results were inconclusive. Thus, the present study was aimed to evaluate the association between the HFE polymorphisms (H63D and C282Y) and cancer risk via meta-analysis. Materials and Methods: We retrieved PubMed, Google Scholar, Embase and Web of Science databases for all eligible studies up to April 1, 2015. All the statistical analysis was conducted by STATA 12.0. Results: Finally, a total of 20 publications including 24 case-control studies, comprising 6,524 cases and 31,080 controls for HFE-C282Y polymorphism and 19 publications including 21 case control studies, comprising 5,648 cases and 14,257 controls for HFE-H63D polymorphism were enrolled in our analysis. An increased risk for overall cancer risk was identified in HFE-H63D polymorphism under allele contrast (D vs H: OR=1.153; 95%CI=1.031-1.289, Pheterogeneity=0.002), homozygotes vs wide type (DD vs HH: OR=1.449; 95%CI=1.182-1.777, Pheterogeneity=0.391), dominant model (DD+HD vs HH: OR=1.145; 95%CI=1.007-1.301, Pheterogeneity=0.002) and recessive model (DD vs HD+HH: OR=1.416 ; 95%CI=1.156-1.735, Pheterogeneity=0.549), as well as HFE-C282Y under homozygotes vs wide type (YY vs CC: OR=1.428, 95%CI=1.017-2.006, Pheterogeneity=0.220). In addition, in the stratified analysis by cancer type, an increased risk was identified in hepatocellular carcinoma and breast cancer in C282Y polymorphism, as well as pancreatic cancer in H63D polymorphism, whereas a decreased risk of colorectal cancer was identified in C282Y polymorphism. Conclusions: Present study suggested that H63D and C282Y polymorphisms associated with an increased risk of overall cancer. Nevertheless, well-designed study with large sample size will be continued on this issue of interest.

Catalytic Effects on Graphitized Carbon Fibers of Graphitization Catalysts Introduced during Hot-Water Stretching (열수 연신시 흑연화 촉매 도입에 따른 탄소섬유의 흑연화 촉진효과)

  • Hyun-Jae Cho;Hye Rin Lee;Byoung-Suhk, Kim;Yong-Sik, Chung
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.162-169
    • /
    • 2024
  • In this study, PAN(polyacrylonitrile)-based precursor fibers were produced through a wet-spinning process, and their morphologies and graphitization behavior were investigated in the presence of two graphitization catalysts (Ca, Ni). The graphitization catalysts were introduced into the formed pores during hot-water stretching of wet-spun PAN-based precursor fibers. The catalytic effects of graphitization catalysts were examined through crystal structure and Raman analysis. At a relatively low temperature of 1500℃, the graphitization was not significantly affected, whereas at a high temperature of 2400℃, the obtained ID/IG value of graphite fiber (GF-Ni100) was decreased by about twice (~0.28) compared to the untreated fibers (GF-AS~0.54). By comparing the ID/IG values (GF-Ca100~0.42: GF-Ni100~0.28) of Ca and Ni graphitization catalyst, it was found that the degree of graphitization of Ni graphitization catalyst showed higher influence than that of Ca graphitization catalyst. Moreover, 2D band was also observed, indicating that the graphite plane structures composed of multiple layers were developed. XRD results confirmed that the crystal inter-planar distance (d002) of the graphite crystal was slightly decreased after the treatment with the graphitization catalyst, But, the crystal size of Ca-treated graphite fiber (GF-Ca100) was increased by up to ~5 nm.

Effects of Impregnation on the Manufacture of High Density Carbon Materials (고밀도 탄소재 제조시의 함침효과)

  • 염희남;김경자;이종민;정윤중
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.10
    • /
    • pp.852-858
    • /
    • 1993
  • The effect of coal tar ptch-impregnated carbon materials which were made from petroleum coke was investigated at various pressure time and impregnation-sintering cycle. As a result, density and bending strength of the carbon materials were remarkably increased in the condition of pressure times of 5hrs and of the cycle of 3rd times. And the value of d002 and Lc of the graphitic carbon sintered at 230$0^{\circ}C$ shwoed 3.387$\AA$ and 167$\AA$, respectively.

  • PDF

Clinical Effects of SJ-002 on URI - Upper Respiratory Tract Infection - (상기도감염증에 대한 SJ-002액의 임상적 고찰)

  • Chung, Byung-Chun;Kim, Kwang-Won;Woo, Un-Joh;Lee, Young-Sunk;Kim, Seung-Woan;Choi, Young-Hwan;Kim, Yeon-Jae;Kim, Sung-Rok;Kim, Soo-Dong
    • The Korean Journal of Pharmacology
    • /
    • v.27 no.2
    • /
    • pp.211-214
    • /
    • 1991
  • SJ-200 is an oral liquid preparation of acetaminophen, ibuprofen, Dl-methyleph edrine HCl, caffeine, chlorpheniramine maleate, guaifenesin and dextromethorphan HBr, which is indicated when there is a need to improve various cold symptoms such as headache, sore throat, fever, or cough etc. Thirty patients was enroled for this study fro June to July, 1991. They were given one bottle (30 ml) of SJ-200 t.i.d dy P.O for an average of one to seven days. 1) Twenty-eight patients (84.8%) were relieved from the symptoms of upper respiratory tract infection. 2) Side effects with this preparation occured in 8 patients924.2%) but in four patients, they were mild, which wee transienty by the discontinuation f the medication.

  • PDF

Evaluation of the Usefulness of the Self-developed Kw-infrared Reflective Marker in Non-coplanar Treatment (비동일면 치료 시 자체 제작한 Kw-infrared Reflective Marker의 유용성 평가)

  • Kwon, Dong-Yeol;Ahn, Jong-Ho;Park, Young-Hwan;Song, Ki-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose: In radiotherapy that takes into account respiration using a RPM (Real time Position Management, Varian, USA) system, which can treat in consideration of the movement of tumor, infrared reflective markers supplied by manufacturers cannot obtain respiratory signal if the couch rotates at a certain angle or larger. In order to solve this problem, the author developed the 3D infrared reflective marker named 'Kw-marker' that can obtain respiratory signal at any angle, and evaluate its usefulness. Materials and Methods: In order to measure the stability of respiratory signal, we put the infrared reflective marker on the 3D moving phantom that can reproduce respiratory movement and acquired respiratory signal for 3 minutes under each of 3 conditions (A: $couch\;0^{\circ}$, a manufacturer's infrared reflective marker B: $couch\;0^{\circ}$, Kw-marker C: $couch\;90^{\circ}$, Kw-marker). By analyzing the respiratory signal using a breath analysis program (Labview Ver. 7.0), we obtained the peak value, valley value, standard deviation, variation value, and amplitude value. In order to examine the rotation error and moving range of the target, we placed a B.B phantom on the 3D moving phantom, and obtained images at a couch angle of $0^{\circ}$ and $90^{\circ}$ using OBI, and then acquired the X, Y and Z values (mm) of the ball bearing at the center of the B.B phantom. Results: According to the results of analyzing the respiratory signal, the standard deviation at the peak value was A: 0.002, B: 0.002 and C: 0.003, and the stability of respiration for amplitude was A: 0.15%, B: 0.14% and C:0.13%, showing that we could get respiratory signal stably by using the Kw-marker. When the couch rotated $couch\;90^{\circ}$, the mean rotation error of the ball bearing, namely, the target was X: -1.25 mm, Y: -0.45 mm and Z: +0.1 mm, which were within 1.3 mm on the average in all directions, and the difference in the moving range of the target was within 0.3 mm. Conclusion: When we obtained respiratory signal using the Kw-marker in non-coplanar treatment where the couch rotated, we could acquire respiratory signal stably and the Kw-marker was effective enough to substitute for the manufacturer's infrared reflective marker. When the rotation error and moving range of the target were measured, there was little difference, indicating that the displacement of the reflector movement in couch rotation is the cause of change in the scale and amplitude of respiratory signal. If the converted value of amplitude height according to couch angle is studied further and applied, it may be possible to perform non-coplanar phase-based gating treatment.

  • PDF

A Clinical and Pathological Analysis of Children with Membranoproliferative Glomerulonephritis According to the Clinical Manifestations at Presentation (발견 양상에 따른 소아 막증식성 사구체신염의 임상적 및 병리조직학적분석)

  • Jeon Chang-Ho;Kang Mi-Seon;Chung Woo-Yeong
    • Childhood Kidney Diseases
    • /
    • v.8 no.2
    • /
    • pp.186-194
    • /
    • 2004
  • Purpose: Membranoproliferative glomeulonephritis(MPGN) has been diagnosed in an increasing number of asymptomatic cases. These cases have been detected by school urinary screening test even though the total cases of MPGN show a decreasing trend. We have analyzed the clinical and pathological characteristics of children with MPGN according to the clinical manifestations at the time of disease presentation. Methods: A total of 18 patients who had been diagnosed with idiopathic MPGN by percutaneous renal biopsy from January 1990 to February 2004 were involved in our study. The patients were divided into 2 groups as the school urinary screening(A) group and the symptomatic(S) group according to the clinical manifestations at the time of disease presentation. Results: Out of the total 18 patients, 8(44.4%) were in the S group and 10(55.6%) were in the A group. The mean serum total protein, albumin and $C_3$ levels in the S group were significantly lower than those levels of the A group, respectively($4.9{\pm}1.2\;g/dL,\;vs\;7.0{\pm}0.5\;g/dL\;P=0.002,\;2.8{\pm}0.9\;g/dL\;vs.\;4.1{\pm}0.3\;g/dL\;P=0.002,\;63.9{\pm}36.4\;mg/dL\;vs.\;100.8{\pm}39.5\;g/dL\;P=0.041$). The mean total protein amount of 24 hour collected urine in the S group were significantly higher than that of the A group($3684.0{\pm}2601.3\;mg/m^2\;vs.\;559.4{\pm}4.6.9\;mg/m^2$, respectively, P=0.001). Hypocomplementemia was observed in 11(61.1%) out of 18 patients at the time of disease onset, 7(87.5%) in the S group and 4(40%) in the A group. However the hypocomplementemia was decreased in 6(33.3%) out of 18 patients at the time of final follow-up, 3(37.5%) in the S group and 3(30%) in the A group. According to the pathologic type, hypocomplementemia was observed 8 patients(61.5%) with type I disease, 1 patients (100%) with type II disease, 2 patients(50%) in type III disease at the disease onset, but 4 patients(30.8%) in type I disease, 1 patient(100%) in type II disease, 1 patient(33.3%) with type III disease at the time of last follow-up. The incidence of cellular crescent formation and tubular atropy. as observed on light microscopy, were higher in the S group compared to the A group. Mean grade of capillary wall thickening and, mesangial proliferation were significantly higher in the S group. Conclusion: MPGN, as diagnosed in patients with only asymptomatic urinary abnormalities, has been increasing, it is more frequent in asymptomatic patients than in patients with presenting symptoms. Our result suggests that MPGN should be considered in the renal biopsy diagnosis regardless of serum $C_3$ level when urinary abnormalities are found by school urinary screening test.

  • PDF