• 제목/요약/키워드: Cylindrical separator

검색결과 16건 처리시간 0.022초

Development of Physical Treatment Technology for Stall Wastewater

  • Oh, In-Hwan;Park, Jeung-Hyun
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.728-736
    • /
    • 1996
  • Solid/Liquid(S/L) separation is crucial for biological treatment of animal wastewater. Liquid portion from S/L separation has less BOD-load and proper post-strip treatment can be obtained . Screen or declined sieve was normally used to separate the solid parts. For better separating efficiency a vibration and a cylindrical separator were constructed and tested. The results are summarized as follows : Solids removal efficiency and moisture content of separated solid were 15-26% and 85-88%, respectively for the vibration separator. For the cylindrical separator, solid removal efficiency and moisture content of solid were 16-39% and 86-89% , respectively. The greatest amount of drymatter was obtained when operating vibration separator with 10。 inclination and 100% vibrating power. For the cylindrical separator maximum efficiency was obtained with 40rpm and 19 inclination . The vibration and the cylindrical separator have shown 21% and 26% in BOD removal, respectively. These two types of separator were proved to be applicable methods for animal wastewater separation.

  • PDF

畜舍尿汚水의 物理的 固液分離技術 開發 (Development of Solid/liquid Separation Technology for Stall Wastewater)

  • 오인환;박정현;장동일
    • 한국축산시설환경학회지
    • /
    • 제2권1호
    • /
    • pp.79-86
    • /
    • 1996
  • 축사뇨오수의 전처리단계로 고액 분리기를 제작하여 분리효율에 관한 시험을 수행한 결과는 다음과 같다. 진동체 고액분리기는 최저 15%에서 최고 26%까지 분리율을 나타내었으며, 분리고형물의 수분함량은 85~88% 사이였다. 회전원통형 고액분리기도 최저 16%에서 최고 39%까지 분리율을 나타내었으며, 고형물의 수분함량은 86~89% 사이였다. 최대의 분리고형물량은 진동체 고액분리기의 경우에 체의 경사도 $10^{\circ}$와 진동모터 가진력 100%, 회전원통형 고액분리기에서는 회전속도 40rpm과 경사각 19$^{\circ}$에서 얻을 수 있었다. BOD 제거율은 회전원통형 고액분리기가 26%로 진동체 고액분리기의 21% 보다 다소 높았다. 관리측면에서는 회전원통형 고액분리기는 주기적으로 세척을 하여 주어야 한다.

  • PDF

호기성 그래뉼 슬러지 선별 분리기가 호기성 그래뉼 슬러지의 안정성에 미치는 영향 (Effects of Aerobic Granular Sludge Separator on the Stability of Aerobic Granular Sludge (AGS))

  • 권규태;김현구;안대희
    • 한국환경과학회지
    • /
    • 제30권12호
    • /
    • pp.1081-1092
    • /
    • 2021
  • In this study, the effect on the stability of Aerobic Granular Sludge (AGS) caused by an AGS separator was investigated. The AGS separator was a hydrocyclone. The main factors of the AGS separator were filter pore size (0.125~0.600 mm), conical-to-cylindrical ratio (1.5~3.0), and operating time (1~20 min). The AGS/mixed liquor suspended solid (MLSS) ratio gradually increased to 0.500 mm (AGS/MLSS: 84.3±3.0%). AGS was best separated at the conical-to-cylindrical ratio of 2.5 (AGS/MLSS: 84.7±3.3%). As the operating time increased, the AGS separation performance also tended to increase. The shortest AGS separator run time, but the highest AGS separation performance was 10 min (87.0±2.5%). AGS stability was evaluated by operating the selected AGS separator and sequencing batch reactor. The average removal efficiencies of TOC, TCODCr, SS, TN, and TP were 95.7%, 96.9%, 93.0%, 89.0%, and 96.2%, respectively, which met the effluent standards in Korea. In addition, the AGS/MLSS ratio tended to remain constant, and the sludge volume index demonstrated a tendency to decrease from 140 mL/g to 70 mL/g. During the operation, the particles of AGS in optical microscope observations gradually increased.

원통형 회전 분리기를 감시하기 위한 전기저항법의 이용 (An Application of Electrical Resistance Method for Monitoring of Rotating Cylindrical Separator)

  • 이보안;김신
    • 에너지공학
    • /
    • 제20권1호
    • /
    • pp.21-25
    • /
    • 2011
  • 본 연구에서는 방사성 폐기물을 처리하는 원통형 회전 분리기를 감시하기 위해 전기 저항법을 제안하고 수학적 모델을 연구하였다. 회전형 방사성 폐기물 분리기에서 관 벽에 설치된 한 쌍의 전극의 전기 저항은 표면을 따라 형성된 불용해성 입자의 환상 영역의 두께와 그 영역의 불용해성 입자의 농도와 관련이 있다. 본 연구는 전위 방정식에 대한 2차원 해와 실험적인 전도도-농도 관계를 기반으로 전술한 인자들 사이의 해석적 관계를 기술하였다. 또한, 원통형 회전 분리기를 감시하기 위한 전기 저항법의 적용 가능성을 논의 하였다.

실린더형 기-액 원심분리기 내의 유동특성 연구를 위한 CFD 시뮬레이션 (CFD Simulation to Study Flow Characteristics in Cylindrical Gas-Liquid Cyclone Separator)

  • 박경도;박종천;김경미
    • 한국해양공학회지
    • /
    • 제28권4호
    • /
    • pp.280-287
    • /
    • 2014
  • In this paper, the numerical simulation of the gas-liquid flow in a cylinder cyclone separator is performed to investigate the flow characteristics using a commercial software, FLUENT, which solves the Reynolds-averaged Navier-Stokes(RaNS) equations. First, a single-phase flow with water in a gas-liquid cylinder cyclone(GLCC) separator is simulated and compared with the experiments(Farchi, 1990) and numerical simulations(Erdal, 1997). Then, the characteristics of the multi-phase flow for water-air, mud-only, and mud-air cases are discussed in the view point of the feasibilities for a mud handling system.

DEVELOPMENT AND TESTING OF MEDIUM CAPACITY GRAIN FLOUR SEPARATOR

  • Kachru, Rajinder-P
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.966-978
    • /
    • 1993
  • A power operated 90.5 hp electric motor) grain flour separator was designed and developed for separation of grain (wheat, corn, chickpea and soybean) flour into various fractions based on the size of the particles of the product. The separator agitating mechanism, feed control, cylindrical separator unit and an eccentric mechanism. The machine was tested for wheat ( variety ; Sujata) flour separation into four fractions, viz ; semolina, Gr-I and II, flour (coarse) and white (fine) flour. Wheat samples (6.8% m.c., db) were first pearled by CIAE pearler for 15.8% bran removal . The pearled wheat grains were then milled for semolina by a burre mill. The product and machine characteristics were determined at different capacities varying from 24 kg/h to 143 kg/h. It was found that 76 kg/h capacity gave reasonably best results in terms of purity and recovery of semolina vis-a-vis the market product. The energy requirement of the machine at no-load was found to be 230 W and at load c nditions, it varied between 36.3-6.4 KJ per kg of fead seperation. The macine could be used by small flour millers small/medium size traders and retailers and other processors for making available various flour products of different particle size in the market for ready use of the consumers.

  • PDF

Some theoretical and experimental aspects of a new electrodynamic separator

  • Kachru, Rajinder-P
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.979-983
    • /
    • 1993
  • A power operated (0.5 hp electric motor) grain flour separator was designed and developed for separation of grain (wheat, corn, chickpea and soybean) flour it no various fractions based on the size of the particles of the product. The separator is made of mild steel and consists of a hopper, power driven agitating mechanism, feed control , cylindrical separator unit and an eccentric mechanism. The machine was tested for wheat (variety : Subjata) flour separation into four fraction, viz : semolina ; Gr-I and II, flour (coarse) and white (fine) flour. Wheat samples (6.8% m.c., db) were first pearled by CIAE pearler for 15.8% bran removal . The product and machine characteristics were determined at different capacities varying from 24 kg/h to 143 kg/h. It was found that 76 kg/h capacity gave reasonably best results in terms of purity and recovery of semolina vis-a-vis the market product. The energy requirement of the machine at no-load was found to be 230 w and at load conditio s, it varied between 36.3-6.4kj per kg of feed separation. The machine could be used by small flour millers, small/medium size traders and retailers and other processors for making available various flour products of different particle size in the market for ready use fo the consumers.

  • PDF

고정상세포분리기의 개발 및 Cyclosporin A 생산을 위한 고정화 연속배양공정에의 적용

  • 이태호;박성관;장용근;전계택
    • 한국미생물·생명공학회지
    • /
    • 제24권6호
    • /
    • pp.717-725
    • /
    • 1996
  • We have developed an efficient immobilized cell separator for continuous operation of immobilized fungal cell cultures, and applied this separator to actual fermentation process for the production of cyclosporin A (CyA), a powerful immunosuppressant. In the experiments employing highly viscous polymer (carboxymethyl cellulose) solution, the decantor showed good separating performances at high solution viscosites and fast dilution rates. Air duct and cylindrical separator installed inside the decantor turned out to play key roles for the efficient separation of the immobilized cells. By installing the decantor in an immobilized perfusion reactor system (IPRS), continuous immobilized culture was stably carried out even at high dilution rate for a long period, leading to high productivities of free cells and CyA. Almost no immobilized biomass existed in effuluent stream of the IPRS, demonstrating the effectiveness of the decan- tor system for a long-term continuous fermentation. It was noteworthy that we could obtain these results despite of the unfavorable fermentation conditions, i.e., reduced density of the biosupports caused by overgrowth of cells inside the bead particles and existence of high density of suspended fungal cells (10g/l) in the fermentation broth.

  • PDF

Pulsating fluid induced dynamic stability of embedded viscoelastic piezoelectric separators using different cylindrical shell theories

  • Pour, H. Rahimi;Arani, A. Ghorbanpour;Sheikhzadeh, Gh.
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.499-512
    • /
    • 2017
  • This paper deals with nonlinear dynamic stability of embedded piezoelectric nano-composite separators conveying pulsating fluid. For presenting a realistic model, the material properties of structure are assumed viscoelastic based on Kelvin-Voigt model. The separator is reinforced with single-walled carbon nanotubes (SWCNTs) which the equivalent material properties are obtained by mixture rule. The separator is surrounded by elastic medium modeled by nonlinear orthotropic visco Pasternak foundation. The separator is subjected to 3D electric and 2D magnetic fields. For mathematical modeling of structure, three theories of classical shell theory (CST), first order shear deformation theory (FSDT) and sinusoidal shear deformation theory (SSDT) are applied. The differential quadrature method (DQM) in conjunction with Bolotin method is employed for calculating the dynamic instability region (DIR). The detailed parametric study is conducted, focusing on the combined effects of the external voltage, magnetic field, visco-Pasternak foundation, structural damping and volume percent of SWCNTs on the dynamic instability of structure. The numerical results are validated with other published works as well as comparing results obtained by three theories. Numerical results indicate that the magnetic and electric fields as well as SWCNTs as reinforcer are very important in dynamic instability analysis of structure.

조사후시험시설에서의 핫셀 배기포집시스템의 성능평가 (Performance of the Exhaust Filtration System of Hot Cell at PIEF)

  • 황용화
    • 설비공학논문집
    • /
    • 제23권12호
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.