• Title/Summary/Keyword: Cylindrical PN Junction

Search Result 2, Processing Time 0.018 seconds

Approximate Equations and Sensitivity for Breakdown Voltages of Cylindrical PN Junctions in Power Semiconductor Devices (전력 반도체 소자에 적용되는 원통형 PN 접합의 항복전압에 대한 근사식과 민감도)

  • Yun, Jun-Ho;Kim, Hae-Mi;Seo, Hyeon-Seok;Jo, Jung-Yol;Choi, Yearn-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2234-2237
    • /
    • 2008
  • Approximate equations for cylindrical breakdown voltages of planar pn junctions are proposed and verified. The equations show good agreement with the Baliga's results for $r_{j}/Wpp{\leqq}0.3$ and with numerical results for $r_{j}/Wpp{\geqq}0.3$ within 1% error. Sensitivity of the breakdown voltage with respect to the doping concentrations is successfully derived using the approximate equations. The sensitivity formula can be utilized in the area of tolerance design of power semiconductor devices.

Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters (수종의 측정기에 의한 전자선의 선량 측정의 비교)

  • Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.93-100
    • /
    • 1989
  • Several combinations of measuring devices and phantoms were studied to measure electron beams. Silicon Pmt junction diode was used to find the dependence of depth dose profile on field size on axis of electron beam Depths of 50, 80 and $90\%$ doses increased with the field size for small fields. For some larger fields, they were nearly constant. The smallest of field sizes over which the parameters were constant was enlarged with increase of the energy of electron beams. Depth dose distributions on axis of electron beam of $10\times10cm^2$ field were studied with several combinations of measuring devices and phantoms. Cylindrical ion chamber could not be used for measurement of surface dose, and was not convenient for measurement of near surface region of 6MeV electron. With some exceptions, parameters agreed well with those studied by different devices and phantoms. Surface dose in some energies showed $4\%$ difference between maximum and minimum. For 18MeV, depths of 80 and $90\%$ doses were considerably shallower by film than by others. Parallel-plate ion chamber with polystyrene phamtom and silicon PN junction would be recommended for measurement of central axis depth dose of electron beams with considerably large field size. It is desirable not to use cylindrical ion chamber for the purpose of measurement of surface dose or near surface region for lower energy electron beam. It is questionable that film would be recommended for measurement of dose distribution of electron with high energy like as 18MeV.

  • PDF