• Title/Summary/Keyword: Cylindrical Cup

Search Result 65, Processing Time 0.018 seconds

An Improved Scheme for the Blank Holding Force in 3-D Sheet Metal Forming Analysis (3차원 박판금속 성형해석에서의 블랭크 홀딩력 적용방법에 관한 연구)

  • Choi, Tae-Hoon;Huh, Hoon;Lee, Choong-Ho
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.10a
    • /
    • pp.93-97
    • /
    • 1997
  • Since the modified membrane element has the same external appearance as the ordinary membrane element, it is not able to apply the thickness variation of sheet metal in the blank holder to the contact treatment and the equally distributed blank holding force should be inevitably imposed on sheet metal along the periphery regardless of the contact status. But sheet metal does not contact with the blank holder at the periphery, nor the blank holding force is distributed uniformly along the boundary. To impose the blank holding force properly, the scheme is improved so that the blank holding force at each node imposed on sheet metal is dependent on the calculated thickness derivation and a state of equilibrium with the total blank holding force. The validity of the improved scheme is demonstrated with the simulation of cylindrical and rectangular cup deep drawing.

  • PDF

Sclerotinia Rot on Water Cress (Oenanthe javanica) Caused by Sclerotinia sclerotiorum (Sclerotinia sclerotiorum에 의한 미나리 균핵병)

  • Kwon, Jin-Hyeuk;Shen, Shun-Shan;Park, Chang-Seuk
    • Research in Plant Disease
    • /
    • v.9 no.2
    • /
    • pp.85-88
    • /
    • 2003
  • A sclerotinia rot of Water cress (Oenanthe javanica) occurred in the commerical farmers field at Garye-myon, Uiryeong-gun, Gyeongnam Province, Korea, 2002. The typical symptoms appeared on leaves and stems. At first, the infected leaves or stems turned dark green later become watery soft rotted; white fluffy mycelia grew from the lesion, later formed black sclerotia. Sclerotia on the infected plants and PDA medium were globose to cylindrical or irregular in shape and 1.0~10.7 ${\times}$1.0~7.6 mm in size. Cup-shaped aphothecia with numerous asci were formed from sclerotinia and the size were 0.4~1.6 cm in diameter. Asci with 8 spores were cylindrical and 74~236 ${\times}$ 4.2~24.8 m in size. Ascospores of one cell were hyaline, ellipsoid to ovoid in shape, and 8.3~12.4 ${\times}$ 3.6~7.2 m in size. The optimum temperature for mycelial growth was $25^{\circ}C$ , and sclerotinia forma-tion was between 15~$20^{\circ}C$. On the basis of mycological characteristics and pathogenecity test to host plants, the fungus was identified as Sclerotinia sclerotiorum. This is the first report of Sclerotinia sclerotiorum caused sclerotinia rot on Oenanthe javanica caused by in Korea.

Two new naturalized species from South Korea, Chaerophyllum tainturieri Hook. (Umbelliferae) and Barbarea verna (Mill.) Asch. (Cruciferae) (한국 미기록 귀화식물: 전호아재비(산형과)와 봄나도냉이(십자화과))

  • Hong, Jeong-Ki;Park, Su-Hyun;Lee, You-Mi;Oh, Seung-Hwan;Jung, Su-Young;Lee, Bong-Sik
    • Korean Journal of Plant Taxonomy
    • /
    • v.42 no.2
    • /
    • pp.171-177
    • /
    • 2012
  • Two naturalized species, Chaerophyllum tainturieri Hook. (Umbelliferae) and Barbarea verna (Mill.) Asch. (Cruciferae) were newly reported from South Korea. C. tainturieri., 'Jeon-Ho-A-Jae-Bi', was found at World Cup park in Sangam-dong, Mapo-gu, in Seoul, and the genus Chaerophyllum is reported for the first time from South Korea in the present paper. It is distinguished from the genus Sphallerocarpus by having cylindrical fruit, and each furrow with one vitta. B. verna, 'Bom-Na-Do-Naeng-I', was found on a riverside area of Suyeong River, Geumsa-dong, in Busan. It can be distinguished from B. orthoceras by silique 4-8 mm long , seeds 1-2 mm long, and basal rosette leaves with a 4-11 large pairs of lateral lobes.

Sclerotinia Rot of Peucedanum japonicum Thunb. Caused by Sclerotinia sclerotiorum (Sclerotinia sclerotiorum에 의한 갯기름나물 균핵병 발생)

  • Jung, Won-Kwon;Lim, Yang-Sook;Kim, Min-Ki;Kim, Jong-Su
    • Research in Plant Disease
    • /
    • v.27 no.3
    • /
    • pp.115-119
    • /
    • 2021
  • Sclerotinia rot was occurred on the leaf and stem of Peucedanum japonicum Thunb. in greenhouse field of Pohang city of Gyeongbuk province in Korea. The typical symptom of the disease was light brown spot and tipburn on infected leaves. The colony of the isolated fungus was white to light gray in color. Asci were cylindrical shape and 75-240×5.9-17.3 ㎛ in size. Apothecia were cup-shaped with numerous asci and 0.5-0.9 cm in size. Ascospores were aseptate and ellipsoid in shape, and 8.4-10.7×4.8-5.8 ㎛ in size. Sclerotia formed on the plants and potato dextrose agar medium were globose to irregular in shape and black in color. Partial sequencing of rDNA of this isolate showed that it was 100% consistent with that of Sclerotinia sclerotiorum. It was confirmed that the same lesion was formed by reinoculating this pathogen on a healthy P. japonicum Thunb. and the same strain was isolated. This is the first report on the Sclerotinia rot of P. japonicum Thunb. caused by S. sclerotiorum in Korea.

Evaluation of image quality for metal artifact using protocol parameters in the MRI (자기공명영상에서 프로토콜 변화를 이용한 금속인공물의 영상평가)

  • Lee, Su-Hyun;Kim, Do-Gyoung;Kim, Yo-Han;Yeum, Hyei-Jeong;Lee, Heon-Jun;Lim, Ju-Yeon;Choi, Woo-Jeon;Kim, Dong-hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.582-585
    • /
    • 2015
  • In the aging society, TKRA is steadily increased because of joint diseases. Artificial joint used in TKRA generates metal artifacts in the MRI. Metal artifact may affect diagnosis. In study, We are going to minimize the effect of metal artifact to improve the value of diagnosis by changing the sequence and the type of artificial joint(Co-Cr, Ni-Ti). 1.5T AVANTO, plastic containers and each of the artificial joint (Normal, Co-Cr, NiTi) were used. After the artificial joints fixed in a paper cup was inserted in a plastic container of cylindrical, Signal intensity was measured. To obtain strong and uniform signal intensity, the plastic container was filled with water. We changed Sequences(T1 TSE, T2 TSE, PD TSE) and obtained an Axial image. After excepting the maximum and minimum values, We calculated the average of SNR, CNR and PSNR. Consequently, The SNR, CNR value of PD TSE are measured higher than these of T1 TSE, T2 TSE and The PSNR of Co-Cr is higher than this of Ni-Ti. The SNR of Co-Cr is similar to the SNR of normal comparing this of Ni-Ti. As a result, Using sequence of PD Tse and Co-Cr alloy is considered to be useful.

  • PDF