• Title/Summary/Keyword: Cyclic voltammetry

Search Result 1,016, Processing Time 0.022 seconds

Quantitative estimation of reversibility of the discharge process undergone by nickel hydroxide film cathodically deposited on pure nickel as a positive supercapacitor electrode using cyclic voltammetry and potential drop method

  • Pyun Su-Il;Moon Sung-Mo
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.8-13
    • /
    • 1998
  • This work presents the way how to evaluate the degree of reversibility of the discharging process undergone by the nickel hydroxide film cathodically deposited on pure nickel as a positive electrode for electrochemical capacitor using the combined cyclic voltammetry and potential drop method, supplemented by galvanostatic discharge and open-circuit potential transient methods. The time interval necessary just to establish the current reversal of anodic to cathodic direction from the moment just after applying the potential inversion of anodic to cathodic direction, was obtained on cyclic voltammogram. The cathodic charge density passed upon dropping the applied potential, was calculated on potentiostatic current density-time curve. Both the time interval and the cathodic charge density in magnitude can be regarded as being measures of the degree of reversibility of the discharging process undergone by the positive active material for supercapacitor, i.e. , the longer the time interval is, the lower is the degree of reversibility and the greater the cathodic charge density is, the higher is the degree of reversibility. From the applied potential dependences of the time interval and cathodic charge density, discharge at $0.42 V_{SCE}$ was determined to be the most reversible.

A Study on the Stability of Langmuir-Blodgett Films Mixed with Myristic Acid and Stearic Acid (미리스트산과 스테아르산 혼합 LB막의 안정성에 관한 연구)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.2
    • /
    • pp.376-381
    • /
    • 2017
  • We were investigated by cyclic voltammetry to the stability through the electrochemical characteristics of Langmuir-Blodgett films mixed with myristic acid and stearic acid. Fatty acid mixture monolayer LB films was deposited by the LB method on the indium tin oxide(ITO) glass. The electrochemical properties was measured by cyclic voltammetry with a three-electrode system in 0.01 N $NaClO_4$ solution. The measuring range is continuously oxidized to 1650 mV, with an initial potential of -1350 mV was reduced. Scanning rates of 50, 100, 150, 200, and 250 mV/s was set. As a result, LB monolayer films of fatty acid mixture was appeared on irreversible processes by the oxidation current from the cyclic voltammogram. Diffusion coefficient (D) of fatty acid mixture was calculated $7.9{\times}10^{-2}cm^2s^{-1}$ at 0.01 N $NaClO_4$ solution.

A Study on the Electrochemical Characteristics of Langmuir-Blodgett Nano-Films of Phospholipid Compound (인지질 화합물의 나노 Langmuir-Blodgett막의 전기화학적 특성에 관한 연구)

  • Jung, A-Jin;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.311-316
    • /
    • 2012
  • We are investigated to an electrochemical characteristic for Langmuir-Blodgett (LB) films by cyclic voltammetry method. The phospholipid compound was deposited by using the LB method on the Indium tin oxide(ITO) glass. We tried to measure the electrochemical by using cyclic voltammetry with three-electrode system(an Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode) in 0.5, 1.0, 1.5 and 2.0 N $NaClO_4$ solution. A measuring range was reduced from initial potential -1350 mV, continuously oxidized to 1650 mV. As a result, LB films of the phospholipid compounds are appeared irreversible process caused by only the oxidation current from the cyclic voltammogram. The diffusivity(D) effect of LB films decreased with increasing of phospholipid compound amount.

A Study on the Stability of Langmuir-Blodgett(LB) Films of Saturated Fatty Acid Monolayer (포화지방산 단분자층 LB막의 안정성에 관한 연구)

  • Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.352-358
    • /
    • 2014
  • We were investigated the stability through the electrochemical characteristics of saturated fatty acid(C12, C14, C16, C18) monolayer LB films by cyclic voltammetry. Saturated fatty acid monolayer LB films was deposited on the indium tin oxide(ITO) glass by the LB method. The electrochemical properties were measured by cyclic voltammetry with a three-electrode system in 0.1 N $NaClO_4$ solution. The measuring range was continuously oxidized to 1650 mV, with an initial potential of -1350 mV was reduced. Scanning rates of 50, 100, 150, 200, and 250 mV/s were set. As a result, LB monolayer films of saturated fatty acid were appeared on irreversible processes by the oxidation current from the cyclic voltammogram. Diffusion coefficient(D) of saturated fatty acid(C12, C14, C16, and C18) was calculated 22.231, 2.461, 7.114 and 2.371 ($cm^2s^{-1}{\times}10^{-4}$) in 0.1 N $NaClO_4$ solution, respectively.

Assay of Trace Gold Ion in a Skin Cell Using a Stripping Voltammetry

  • Ly, Suw-Young;Lee, Jin-Hui;Yi, Jae-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.15-21
    • /
    • 2011
  • Threelectrodes systems were used in stripping voltammetry (SW) and cyclic voltammetry (CV) instead of the expensive platinum and Ag/AgCl reference electrodes. Moreover, the electrolyte solution was used with deep seawater, which can reduce water pollution, is more eco-friendly, and has a lower cost. The analytical optimum parameters measured via CV and SW and with working ranges were obtained from 10 to 80 ug/L using fluorine immobilized on a graphite pencil electrode (FE). Under the optimum conditions, the analytical detection limit of 6.30 ug/LAu was obtained. The results of the study can be applied to diagnostic assay for natural minerals and human finger tissue.

Diagnostic Ex-vivo Assay of Metal Gold in Rat Droppings Using Voltammetry

  • Ly, Suw-Young;Lee, Chang-Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.626-630
    • /
    • 2012
  • Diagnosis with an ex-vivo gold sensor was done using a modified fluorine-doping sensor, and cyclic voltammetry (CV) redox potentials of 0.4 V anodic and -0.2 V cathodic were obtained. Both peak currents were optimized using square-wave (SW) stripping voltammetry, and an analytical working range of 10-80 ug/L SW was attained. The precision of the 10-mg/L Au was 0.765 (n=8) RSD under the optimum conditions, and the analytical detection limit approached 0.006 ug/L (S/N=3) with only a 60 sec accumulation time. The developed method was used to examine the mouse droppings for medicinal diagnosis.

α -Cyclodextrin Modified Screen Printed Graphite Electrodes for Detection of Phenols

  • Kim, Hwa-jeong;Jang, Seung-Cheol;Shim, Yoon-Bo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.427-431
    • /
    • 2002
  • A screen printed graphite electrode has been developed for a simple and sensitive determination of phenolic compounds in an aqueous solution. The electrode developed uses a simple and effective screen printing technique with ${\alpha}-Cyclodextrin({\alpha}-CD)$ modified graphite ink. Phenols were captured on the surface of the ${\alpha}-CD$ modified electrode through complex formation. The phenol/ ${\alpha}-CD$ complex was deposited and quantified electrochemically using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and square wave voltammetry (SWV). The optimization of the experimental parameters was performed in regard to electrode composition, pH, temperature, sample preconcentration time. Interferences from other organic compounds were investigated. The detection limit for phenols was 500 ${\pm}7$ nM for DPV, with the linear range of 0.5 ${\mu}M$ -25.0 ${\mu}M$ and 30 ${\pm}2$ nM for SWV, with the linear range of 30 nM - $50{\mu}M$, respectively.

Mass Transport Properties and Influence of Natural Convection for Voltammetry at the Agarose Hydrogel Interface

  • Kim, Byung-Kwon;Park, Kyungsoon
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.347-353
    • /
    • 2022
  • Agarose hydrogel, a solid electrolyte, was investigated voltammetrically in terms of transport properties and natural convection effects using a ferrocenyl compound as a redox probe. To confirm the diffusion properties of solute on the agarose interface, the diffusion coefficients (D) of ferrocenemethanol in agarose hydrogel were determined by cyclic voltammetry (CV) according to the concentration of agarose hydrogel. While the value of D on the agarose interface is smaller than that in the bulk solution, the square root of the scan rate-dependent peak current reveals that the mass transport behavior of the solute on the agarose surface shows negligible convection or migration effects. In order to confirm the reduced natural convection on the gel interface, scan rate-dependent CV was performed in the solution phase and on the agarose surface, respectively. Slow scan voltammetry at the gel interface can determine a conventional and reproducible diffusion-controlled current down to a scan rate of 0.3 mV/s without any complicated equipment.

Measuring Oxytetracycline Using a Simple Prepared DNA Immobilized on a Carbon Nanotube Paste Electrode in Fish Tissue (DNA 고정 탄소나노튜브 페이스트전극의 물고기 세포속 테트라싸이클린에 정량)

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • Journal of the Korean Chemical Society
    • /
    • v.51 no.5
    • /
    • pp.412-417
    • /
    • 2007
  • A simple prepared paste electrode (PE) of DNA immobilized on a carbon nanotube was utilized for monitoring the antibacterial agent oxytetracycline (OTC), using square-wave anodic stripping voltammetry (SWASV) and cyclic voltammetry (CV). Given these conditions, SWASV and CV working ranges were observed within 1-10 ngL-1 OTC. In the SWASV and CV for OTC concentrations of 0.1 mgL-1, the relative standard deviations (n=15) were 0.068 and 0.067, respectively. At the optimized condition, the detection limit was found to be 0.4 ngL-1 OTC. This method was applied to the hatchery fish tissue.

Capacitance Properties of the Polypyrrole Films Electropolymerized in Different Electrolyte Solutions (전해 중합에 따른 폴리피롤 필름의 캐페시턴스 특성)

  • Park Ho Chul;Noh Kun Ae;Kim Jong Huy;Ko Jang Myoun
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.94-97
    • /
    • 2001
  • Electro-conducting Polypyrrole(PPy) films were Prepared by applying constant current in various electrolytes solutions and their capacitance properties were investigated using cyclic voltammetry. Capacitance values were strongly dependent on the electrolytes solution used in electrochemical polymerization. PPy prepared in PC/AN mixture solution containing 0.5M $LiClO_4$ with small amount water showed 401 F/g and that electrogenerated in $AN/H_2O$ mixture solution containing 0.5M $LiClO_4$ retained $70\%$ of initial capacitance after 2000 cycles.