• Title/Summary/Keyword: Cyclic Measurement

Search Result 250, Processing Time 0.022 seconds

Development of a Fatigue Index Based on the Measurement of Localized Muscular Fatigue During the Cyclic Isometric Contraction (주기적 등척성 수축에서의 국소근육피로 측정을 통한 피로지수의 개발)

  • Jung, So-Ra;Chung, Min-Keun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.19 no.4
    • /
    • pp.87-96
    • /
    • 1993
  • Spectrum analysis of surface electromyogram (FMG) signals is an effective approach to the study of localized muscular fatigue during isometric contraction. Many investigators have con firmed the frequency of the EMG signals being lowered during sustained contaction. In this study, the cyclic loading tasks were performed, and a comparison was made for the median power frequency shift pattern of the EMG signals with the sustained contraction of the same load. The median power frequency shift of the EMG signals for the cyclic loading task was found to be a part of that for the sustained contraction. Based on this result, a new muscle fatigue index was computed by normalizing the duration of the sustained contraction. A fatigue index was obtained as a function of exertion level and the work/rest schedule. With the proposed fatigue index, it is possible to evaluate or predict the degree of muscular fatigue for a physically demanding task.

  • PDF

Evaluation of Fatigue Strain Intensity Factor on Fatigue Crack Propagation Rate (da/dN) (금속 재료의 피로 균열 전파 속도(da/dN) 평가를 위한 변형율 확대 계수의 유효성 검토)

  • 유재환;최재강;손종동
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.3-8
    • /
    • 1996
  • Fatigue fracture is the cyclic fracture phenomena at a very small local area near a crack tip. Therefore, the detailed quantitative experimental analysis about local cyclic strain distribution near a crack tip is prerequisite In order to make an effective parameter able to account for fatigue fracture problems. However, there are few reports on detailed quantitative experimental analysis of a local cyclic strain distribution near a crack tip, because of experimental difficulties. In this study, the distribution of local fatigue strains near a fatigue crack tip was in detail studied using by fine dot grid strain measurement method. From these results, a single parameter, which characterizes local fatigue strain field, was proposed. In addition, this parameter was applied to evaluate the fatigue crack propagation rate.

  • PDF

Long-Term Measurement under the Moving train at the Test Reinforced Roadbed Site in Railway (철도강화노반 시험부설구간에서의 열차 주행시 장기거동 계측)

  • 황선근;신민호;이성혁;최찬용;이시한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.223-230
    • /
    • 2001
  • Nine different types of the reinforced railroad roadbeds which . are located in between Suwon-Chunan station of Kyongbu line were constructed in order to increase the bearing capacity of railroad roadbed and to improve the ridability as a part of speed-up project of conventional railroad systems. Each three sections were composed of weathered granite soil, crushed stone and furnace slag(HMS25), and fully instrumented with earth pressure cells, settlement plates and geophones to monitor the behavior of roadbeds under actual train loads. Field measurement has continued since October 31, 2000 and presently with rather longer measurement interval. The measurement data such as settlement, earth pressure and vibration levels are currently under analysis process. In this paper, only cumulative measurement data of railroad roadbeds were introduced. In the near future, comprehensive measurement data and result of analysis will be presented and design technique for the reinforced railroad roadbed will be proposed as a final product of this study.

  • PDF

Electrochemical Properties of Langmuir-Blodgett(LB) Film of Alkyl Bromides (브롬화 알킬화합물 LB막의 전기화학적 특성)

  • Park, Keun-Ho;Son, Tae-Chul;Min, Chang-Hun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.451-456
    • /
    • 2009
  • We carried out this experiment to observe an electrochemical properties for LB films of alkyl compounds by the cyclic voltammetry. Alkyl bromides was deposited by using the Langmuir- Blodgett method on the ITO glass. We measured to an electrochemical measurement by using cyclic voltammetry with a three-electrode system(an Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode) in 0.5, 1.0, 1.5 and 2.0 N $NaClO_4$ solution. A measuring range was reduced from initial potential to -1350 mV, continuously oxidized to 1650 mV. The scan rate were 100 mV/s. As a result, an electrochemical properties of the LB films of alkyl bromides appeared irreversible process caused by only the oxidation current from the cyclic voltammogram. The diffusivity(D) effect of LB films decreased with increasing of alkyl compounds amount.

Electrochemical Properties of Langmuir-Blodgett Films of 4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene and Dilauroyl-L-${\alpha}$-Phosphayidylcholine Mixture (4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene과 Dilauroyl-L-${\alpha}$- Phosphayidylcholine의 혼합 LB막의 전기화학적 특성)

  • Kim, Beom-Joon;Min, Byoung-Chul;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2002
  • We carried out this experiment to observe electrochemical properties for LB films of phospholipid(Dilauroyl-L-${\alpha}$-Phosphayidylcholine) and 4-octyl-4'-(5-carboxypentamethylene-oxy)azobenzene mixture by the cyclic voltammetry. LB films of 8A5H and 8A5H-DLPC(1:1, 2:1) were deposited by using the Langmuir-Blodgett method on the ITO glass. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference elect rode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in 0.1, 0.5, and 1.0 mol/L $NaClO_{4}$ solution. A measuring range was reduced from initial potential to -1350 mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150 and 200 mV/s. As a result, LB films of 8A5H 8A5H-DLPC appeared irreversible process caused by only the oxidation current from the cyclic voltammogram.

Nondestructive Damage Sensitivity of Carbon Nanotube and Nanofiber/Epoxy Composites Using Electro-Micromechanical Technique and Acoustic Emission (Electro-Micromechanical 시험법과 음향방출을 이용한 탄소 나노튜브와 나노섬유 강화 에폭시 복합재료의 비파괴적 손상 감지능)

  • Kim, Dae-Sik;Park, Joung-Man;Lee, Jae-Rock;Kim, Tae-Wook
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.117-120
    • /
    • 2003
  • Electro-micromechanical techniques were applied using four-probe method for carbon nanotube (CNT) or nanofiber (CNF)/epoxy composites with their content. Carbon black (CB) was used to compare with CNT and CNF. The fracture of carbon fiber was detected by nondestructive acoustic emission (AE) relating to electrical resistivity for double-matrix composites test. Sensing for fiber tension was performed by electro-pullout test under uniform cyclic strain. The sensitivity for fiber damage such as fiber fracture and fiber tension was the highest for CNT/epoxy composites, and in CB case they were the lowest compared with CNT and CNF. Reinforcing effect of CNT obtained from apparent modulus measurement was the highest in the same content. The results obtained from sensing fiber damage were correlated with the morphological observation of nano-scale structure using FE-SEM. The information on fiber damage and matrix deformation and reinforcing effect of carbon nanocomposites could be obtained from electrical resistivity measurement as a new concept of nondestructive evaluation.

  • PDF

유압펌프에서 발생되는 고주파 유량맥동의 고응답 계측

  • 이상기;김도태
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.267-272
    • /
    • 1995
  • The paper describes an approach for measuring flow ripple generated by oil hydraulic axial piston pumps. Flow ripple has periodic waveforms due to the cyclic nature of a pump's operation, and interacts with the connected hydraulic systems such as pipes and components to produce a pressure ripple, also known as fluid-borne noise. It is indispensable to measure a flow ripple because increasing of vibration and noise caused by a flow ripple has become a point to be considered and has need of solving these problems. The measurement of flow ripple with high frequencies from oil hydraulic axial piston pumps is msde by using the remote instantaneous flow rate measurement method. As a result, the reverse flow through the relief groove in valve plate has an important effect upon a flow ripple generated by a pumps.

  • PDF

Effect of internal stress on cyclic fatigue failure in .06 taper ProFile (내부 응력이 .06 taper ProFile의 피로 파절에 미치는 영향)

  • Jung, Hye-Rim;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.79-83
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. Materials and Methods: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. Results: In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). Conclusion: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.

Development of SFM System for Nano In-Process Profile Measurement (나노인프로세스 표면형상계측을 위한 SFM시스템의 개발)

  • Kweon, Hyun-Kyu;Choi, Seong-Dae;Hong, Sung-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.2
    • /
    • pp.53-59
    • /
    • 2004
  • In this paper, we propose a new multi-purpose Scanning Force Microscope (SFM) system. The system can be used for nano/micro-scratching, in-process profile measurement, and observation of potential surface defects which occur during the scratching in air or liquid. Experimental results of nano/micro-scratching show that the smallest scratching depth can be controlled to be 10nm, which corresponds to the stability of the SFM system. Profile measurements of nano/micro-scratching surfaces have also been performed by the method of on-machine measurement and in-process measurement. Two measurement results were in good agreement with each other. The maximum difference was approximately 10 nm, which was mainly caused by the sampling repeatability error that influences the measurement accuracy Also, micro-defects on the micro-scratching surface were successfully detected by the SFM system. It was confirmed that the number of micro-defects increases when the surface is subjected to a cyclic bending load. The maximum depth was less than 100nm.

  • PDF

Characteristics of hydrogen adsorption peaks of electrodes containing ionic liquid for high temperature polymer electrolyte fuel cells (고온 연료전지용 이온성 액체를 함유한 전극의 수소 흡착피크의 특성)

  • Ryu, Sung-Kwan;Park, Jin-Soo;Yang, Tae-Hyun;Park, Seung-Hee;Park, S.H.;Yoon, Y.G.;Kim, Han-Sung;Kim, Chang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.382-382
    • /
    • 2009
  • In this study, we prepared electrodes containing ionic liquid for high temperature polymer electrolyte fuel cells. Effects of ILs on electrochemical properties of the electrodes were investigated carrying out measurement of cyclic voltammograms of the various electrodes with the content of IL in a strong supporting electrolyte. As the ILs content increased in electrodes, electrochemical surface area(ESA) decreased due to the leakage of ILs from Nafion ionomer. In addition, two case of cyclic voltammograms under two simulated environment, i.e. IL leakage from Nafion ionomer in I) electrode and ii) polymer electrolyte, were investigated. As a result, IL leakage from polymer electrolyte showed worse results in electrochemical properties of the electrode.

  • PDF