• 제목/요약/키워드: Cyclic Measurement

검색결과 250건 처리시간 0.026초

Poly-${\gamma}$ Benzyl $_D$-Glutamate 유기박막의 전자이동특성에 관한 연구 (A Study on the Electronic Properties of Poly-$\gamma$ Benzyl $_D$-Glutamate Organic Thin Films)

  • 송진원;이경섭;이봉주;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 센서 박막재료 반도체재료 기술교육
    • /
    • pp.86-89
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Al and Au/Poly-${\gamma}$ Benzyl $_D$-Glutamate/Au; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

OFDM 심벌 타이밍 옵셋에 의한 Uncoded-BER 측정 결과 (Measurement Results of Uncoded-BER with respect to OFDM Symbol Timing Offset)

  • 이재호;라상중;최동준;허남호
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2014년도 하계학술대회
    • /
    • pp.243-245
    • /
    • 2014
  • 본 논문에서는 OFDM(Orthogonal Frequency Division Multiplexing)시스템에서 OFDM 심벌 타이밍 옵셋에 따른 4096QAM 의 uncoded-BER(Bit Error Rate) 및 성상도를 측정하였다. uncoded-BER 은 수신기의 FEC(Forward Error Correction) 복호기 이전에서 측정된 BER 을 의미한다. 측정을 위해, OFDM 을 사용하는 DVB-C2(Digital Video Broadcasting for Cable Systems 2) 송수신기를 FPGA(Field Programmable Gate Array)를 이용하여 구현하였으며, OFDM 심벌의 CP(Cyclic Prefix)를 이용하여 OFDM 심벌 동기를 수행하였다. 일반적으로, OFDM 심벌 동기는 OFDM 심벌에서 CP 가 반복된다는 특성을 이용한 상관기를 사용한다. 또한, ISI(Inter Symbol Interference) 및 ICI(Inter Channel Interference)를 최소화하기 위해, 채널의 최대 지연시간을 고려하여 CP 내에서 OFDM 심벌 동기가 획득된다. 이럴 경우 수신기에서는 각 부반송파에 할당된 QAM 심벌들의 위상 회전이 발생하지만, 등화기에서 이러한 위상 회전이 보상된다. 부반송파에 할당된 파일롯 심벌들을 이용하여 채널 추정 및 보상을 하는 등화기에서, 파일롯 심볼들도 OFDM 심벌 타이밍 옵셋에 의해 위상회전이 발생하기 때문에 채널 추정 값에 영향을 미친다. 따라서, 본 논문에서는 4096QAM 과 ZF-LE(Zero Forcing Linear Equalizer)를 사용한 경우, OFDM 심벌 타이밍 옵셋에 따른 uncoded-BER 및 성상도의 측정 결과를 제시하였다.

  • PDF

원격계측을 위한 무선 통신 에러 검사 알고리즘 개발 (The Development of the Data Error Inspection Algorithm for the Remote Sensing by Wireless Communication)

  • 김희식;김영일;설대연;남철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.993-997
    • /
    • 2004
  • A data error inspection algorithm for wireless digital data communication was developed. Original data converted By wireless digital data error inspection algorithm. Wireless digital data is high possibility to get distortion and lose by noise and barrier on wireless. If the data check damaged and lost at receiver, can't make it clear and can't judge whether this data is right or not. Therefore, by wireless transmission data need the data error inspection algorithm in order to decrease the data distortion and lose and to monitoring the transmission data as real time. This study consists of RF station for wireless transmission, Water Level Meter station for water level measurement and Error inspection algorithm for error check of transmission data. This study is also that investigation and search for error inspection algorithm in order to wireless digital data transmission in condition of the least data's damage and lose. Designed transmitter and receiver with one - chip micro process to protect to swell the volume of circuit. Had designed RF transmitter - receiver station simply by means of ATMEL one - chip micro processing the systems. Used 10mW of the best RF power and 448MHz-449MHz on frequency band which is open to public touse free within the limited power.

  • PDF

스크린 프린터에 의한 광캐패시터용 카본 전극 제작 (Screen-printed carbonaceous matrrials for photocapacitor electrode)

  • 최우진;곽동주;성열문;하순호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.411-414
    • /
    • 2009
  • Photo-capacitor electrodes are attracting great attention because of their high capacitance and potential applications in electronic devices. Carbon capacitor, active carbon capacitor and its combination will be fabricated using simple sandwich capacitor electrode method as carbonaceous material on each type of capacitor electrodes with 20 ${\times}$ 15 mm cell size. Carbon/active carbon cell was fabricated using sol-gel process with 120oC dry temperature in l hour and using sintering process with 500oC in 2 hour. The effect of sintering temperature on carbon properties was also investigated with X-ray diffraction technique to get the best sintering temperature. The detail of fabrication process will be explained. Elemental composition in electrode material can be measured using quantitative spectroscopic as and a cyclic voltammetric technique was used to study the combined effects of electrode material and effect of annealing temperature and also time on the capacitance of thermally treated in capacitor electrode. In this work, characterization impedance technique is used to measurement of capacitance and giving complementary results. Active carbon as carbonaceous material has a better capacitance in charge/discharge process with mean thickness $32{\mu}m$ and with particle size $1{\mu}m$ to $4.5{\mu}m$ in 20 ${\times}$ 15 mm sample size of capacitor electrode.

  • PDF

전도성 고분자/CdTe 나노입자/탄소 나노튜브 복합박막의 특성 연구 (Characterization of Conducting Polymer/CdTe Nanoparticles/Carbon Nanotube Composites in Thin Films)

  • 김도훈;심성은;김정수;남대근;오원태
    • 한국전기전자재료학회논문지
    • /
    • 제26권4호
    • /
    • pp.315-320
    • /
    • 2013
  • The composites composed of conducting polymer (MEH-PPV), CdTe nanoparticles, and multiwalled carbon nanotubes (MWNTs) were spectroscopically and electrically characterized in their thin films. The composite films were prepared by spray coating. These composites were prepared from the mixture solution of MEH-PPV and CdTe-embedded MWNTs, in which CdTe nanoparticles were electrostatically bound to MWNTs. UV/vis and PL spectra were analyzed to investigate the optical absorbance and emission of the composite films. In addition, their structural, electrochemical, and electrical properties were studied by transmission electron microscopy, cyclic voltammetry, and I-V measurement.

직접 메탄올 연료전지용 PtRu/GNF 성능에 대한 화학적 처리의 영향 (Effect of Chemical Treatment on Performance Behaviors of PtRu/GNFs Catalysts for DMFCs)

  • 박수진;박정민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.369-372
    • /
    • 2009
  • In the present study, the effect of chemical treatment on graphite nanofibers (GNFs) supports with various concentrated nitric acids was investigated for methanol oxidation. To optimize the electrocatalytic activity, PtRu catalysts were deposited on GNF supports by impregnation method. The surface and structural properties of the GNF supports were characterized by X-ray photoelectron spectroscopy (XPS), element analyzer (EA), and X-ray diffraction (XRD). The morphology of the catalysts was observed by means of transmission electron microscopy (TEM). The electrocatalytic activity of PtRu/GNF catalysts was investigated by cyclic voltammetry measurement. As a result, the oxygen functional groups were introduced on the GNF supports and were gradually increased with increasing of concentrated nitric acid, causing the smaller particle size and higher loading level. And the electrocatalytic activity of the catalysts for methanol oxidation was gradually improved. Consequently, it was found that chemical treatments could influence on surface properties of the carbon supports, resulting in enhancing the electrocatalytic activity of the catalysts for DMFCs.

  • PDF

Reference Electrode at Molten Salt: A Comparative Analysis of Electroceramic Membranes

  • Yoon, Seokjoo;Kang, Dokyu;Sohn, Sungjune;Park, Jaeyeong;Lee, Minho;Choi, Sungyeol
    • 방사성폐기물학회지
    • /
    • 제18권2호
    • /
    • pp.143-155
    • /
    • 2020
  • A reference electrode is important for controlling electrochemical reactions. Evaluating properties such as the reduction potential of the elements is necessary to optimize the electrochemical processes in pyroprocessing, especially in a multicomponent environment. In molten chloride systems, which are widely used in pyroprocessing, a reference electrode is made by enclosing the silver wire and molten salt solution containing silver chloride into the membranes. However, owing to the high temperature of the molten salt, the choice of the membrane for the reference electrode is limited. In this study, three types of electroceramic, mullite, Pyrex, and quartz, were compared as reference electrode membranes. They are widely used in molten salt electrochemical processes. The potential measurements between the two reference electrode systems showed that the mullite membrane has potential deviations of approximately 50 mV or less at temperatures higher than 650℃, Pyrex at temperatures lower than 500℃, and quartz at temperatures higher than 800℃. Cyclic voltammograms with different membranes showed a significant potential shift when different membranes were utilized. This research demonstrated the uncertainties of potential measurement by a single membrane and the potential shift that occurs because of the use of different membranes.

Metal/Organic Films/Metal에서 계면특성에 관한 연구 (A Study on the Interface Properties of Metal/Organic Films/Metal)

  • 송진원;조수영;최영일;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.723-726
    • /
    • 2002
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 10[mN/m]. In processing of a device manufacture, we can see the process is good from the change of a surface pressure for organic thin films and transfer ratio of area per molecule. The structure of manufactured device is Au/Poly-$\gamma$ Benzyl $_D$-Glutamate/Al; the number of accumulated layers is 1, 3, 5 and 7. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system. LB film accumulated by monolayer on an ITO. In the cyclicvoltammetry, An Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in $LiBF_4$ solution, stable up to 0.9V vs. Ag/AgCl.

  • PDF

지능형 로봇을 위한 이중 커널 구조의 제어 시스템 구현 및 실시간 제어 성능 분석 (Implementation of Dual-Kernel based Control System and Evaluation of Real-time Control Performance for Intelligent Robots)

  • 박정호;이수영;최병욱
    • 제어로봇시스템학회논문지
    • /
    • 제14권11호
    • /
    • pp.1117-1123
    • /
    • 2008
  • This paper implements dual-kernel system using standard Linux and real-time embedded Linux for the real-time control of intelligent robot systems. Such system provides more useful services including standard Linux thread that is easy to implement complicated tasks and real-time tasks for the deterministic response to velocity control. Here, an open source real-time embedded Linux, XENOMAI, is ported on embedded target board. And for interfacing with motor controller we adopted a real-time serial device driver. The real-time task was implemented with a priority to keep the cyclic control command for trajectory control. In order to validate deterministic response of the proposed system, the performance measurement of the delay in performing trajectory control with feedback loop is evaluated with non real-time standard Linux. The proposed software architecture is anticipated to take advantage of features in both standard Linux and real-time operating systems for the intelligent robot systems.

Concept Analysis of Health Literacy for Patients with Cardiovascular Disease using Hybrid Model

  • Sim, Jeong Eun;Hwang, Seon Young
    • 지역사회간호학회지
    • /
    • 제30권4호
    • /
    • pp.494-507
    • /
    • 2019
  • Purpose: The purpose of this study is to provide a clear definition of the health literacy for patients with cardiovascular disease by analyzing the dimensions and properties using Hybrid concept analysis. Methods: The concept of health literacy of patients with cardiovascular disease was analyzed according to the cyclic process of theoretical phase-field work phase-final analysis phase presented in the Hybrid model. We reviewed 26 literatures and conducted in-depth interviews with 13 patients with cardiovascular disease. Results: The concept of health literacy in cardiovascular patients is derived from two dimensions and five attributes. Literacy skills, health information search ability and health information utilization skills were derived as attributes in the individual functional dimension, while active communication with the medical team and utilization of health information support resources were derived at the interrelational dimension. It is defined as the individualized and integrated ability of an individual to explore and utilize the various health information needed to make appropriate health decisions during the chronic course after diagnosis of cardiovascular disease, to communicate proactively with medical staffs and to utilize support resources. Conclusion: This study will contribute to the development and related research of health literacy measurement tools that can be used in cardiovascular nursing practice based on the attributes and indicators of health literacy for patients with cardiovascular disease.