• Title/Summary/Keyword: Cycles To Failure

Search Result 423, Processing Time 0.03 seconds

A Study on Growth Behavior of Small Fatigue Crack in 304 Stainless Steel at Elevated Temperatures (고온하 304 스테인레스강의 작은 표면구열의 성장거동에 관한 연구)

  • 서창민;김영호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.87-95
    • /
    • 1990
  • Rotating bending fatigue tests of an authentic steel 304 were performed at various temperatures such as room temperature, $538^{\circ}$ and $593^{\circ}C$. The plastic replica method was also applied in order to estimate the fatigue life on the basis of serial observation of small fatigue crack initiation and growth on the pit specimen surface. The fatigue crack growth behavior of 304 stainless steel was investigated within the frame work of elastic-plastic fracture mechanics within a narrow scatterband in spite of different stress levels at elevated temperature as at room temperature. The growth law of small surface crack is determined uniquely by the term. $\DELTA\sigma^{n}a$ where $\DELTA\sigma$ is the stress amplitude, a is the crack length, and n is a constant. It is found that the small crack growth behavior is basically equivalent to the S-$N_{f}$ relationship, where S and $N_{f}$ are stress and number of cycles to failure, and the fatigue life prediction is in good agreement with the experimental results.

Frictional and Fatigue Characteristics of Journal Bearings by Ultrasonic Nanocrystal Surface Modification (UNSM) (초음파나노표면개질기술을 이용한 저널베어링 마찰 및 피로특성 연구)

  • Choi, Gab-Su;Darisuren, Shirmendagva;Lee, Seung-Chul;Kim, Jun-Hyong;Amanov, Auezhan;Pyun, Young-Sik
    • Tribology and Lubricants
    • /
    • v.31 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • In this study, we apply an ultrasonic nanocrystal surface modification (UNSM) technique to radial journal bearings (JBs) and disks made of SUJ2 and SCM440, respectively. We investigate frictional properties of untreated and UNSM-treated specimens using a ball-on-disk tester. We construct the Stribeck curve at the boundary, under mixed and full hydrodynamic lubrication conditions for the specimens using friction data obtained from JB tests. The friction at the boundary lubrication condition and the transition period to mixed lubrication condition on the UNSM-treated specimens is reduced, which improves the service life of JBs. The major effects of this reduction in the three lubrication regimes can be explained in the terms of improved mechanical properties and the presence of micro dimples. Moreover, we estimate the friction and fatigue properties of SCM440 specimens using a ball-on-disk specimen under dry and oil-lubricated conditions. Friction test results reveal that the UNSM-treated specimens show lower friction coefficient than the untreated specimens under both dry and oil-lubricated conditions. We evaluate the fatigue properties of SCM440 specimens by calculating the Hertzian stress with respect to the failure cycles. Fatigue tests results also reveal that the UNSM-treated specimens possess a longer fatigue life than the untreated specimens. The improved properties are effective in increasing the energy efficiency of bearings.

Low-Cycle Fatigue in Ni-Base Superalloy IN738LC at Elevated Temperature (니켈기 초내열합금 IN738LC의 고온 저주기피로 거동)

  • Hwang, Kwon-Tae;Kim, Jae-Hoon;Yoo, Keun-Bong;Lee, Han-Sang;Yoo, Young-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.10
    • /
    • pp.1403-1409
    • /
    • 2010
  • For many years, high-strength nickel-base superalloys have been used to manufacture turbine blades because of their excellent performance at high temperatures. The prediction of fatigue life of superalloys is important for improving the efficiency of the turbine blades. In this study, low cycle fatigue tests are performed for different values of total strain and temperature. The relations between strain energy density and number of cycles before failure occurs are examined in order to predict the low cycle fatigue life of IN738LC super alloy. The results of low cycle fatigue lives predicted by strain energy methods are found to coincide with experimental data and with the results obtained by the Coffin-Manson method.

A Study on the Application of Pre-Indentation Technique for Fastener Hole Model (FASTENER HOLE 모델의 대한 예비압입 적용 연구)

  • Hwang,Jeong-Seon;Jo,Hwan-Gi
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.26-31
    • /
    • 2003
  • Aging aircraft accumulates widespread fatigue damage commonly referred to as multiple site damage(MSO). For ductile material such as 2024-T3 aluminum, MSO may lower the service life below that which is predicted by conventional fracture mechanics. The present paper is concerned with the fatigue life extension by pre-indentation technique for thin 2024-T3 aluminum plate to decelerate the crack propagation rate in the panels with MSO. The panel with fastener holes can be simply modelled by Hole/Slot type Middle-Tension specimen. Results of fatigue testing show significantly improving failure cycles from 10 to 40 times. This retardation effect is decreased by increasing the loading level in the constant amplitude loading. In the sense of retardation mechanism, the crack propagation rate is gradually attenuated by entering the indentation mark and maintains at the lowest value for a long period after the edge of crack passes the center of indentation area.

SHEAR BOND STRENGTH OF PORCELAIN REPAIR RESINS TO NONPRECIOUS CERAMO-METAL ALLOY (도재소부전장관 파절시 비귀금속과 도재수리용 레진간의 결합력에 관한 실험적 연구)

  • Ann, Joon-Young;Bae, Jung-Soo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.195-209
    • /
    • 1991
  • When the porcelain fused to metal restorations were fractured at the metal interface, various techniques and materials for intraoral porcelain repair have been suggested. The purpose of this study was to investigate the effect of metal surface treatment method and water storage on the shear bond strength of four porcelain repair systems. : Clearfil(Kuraray), All-bond(Bisco), Superbond C & B(Sun Medical), Panavia OP(Kuraray). After the metal surfaces of the specimens were sandblasted by aluminum oxide or roughened by diamond point, they were stored in double deionized water(24 Hr., $37^{\circ}C$) and thermocycling was performed(24 Hr., 1024 cycles), and again half of specimes were stored in water bath(2 Months, $37^{\circ}C$). Mean shear bond strength and mode of failure were recorded. The results of this study were obtained as follows : 1. Differences were observed between the sandblasted and diamond - treated specimens in Clearfil, All-bond, and Superbond. No statistically significant differences were observed in Panavia. 2. The 2-month storage time significantly affected the bond strength of All-bond and Superbond. No statistically significant differences were observed in Clearfil and Panavia. 3. The failures were observed at the interface between opaque resin and the metal in Clearfil and All-bond. 4. The failures were observed at the interface between opaque resin and veneered resin in Panavia. The failures were observed at the interface between opaque resin and veneered resin in Superbond, but 40% of them were fractured at the interface between the metal and opaque resin after 2-month storage time.

  • PDF

Efficacy and Safety of First Line Vincristine with Doxorubicin, Bleomycin and Dacarbazine (ABOD) for Hodgkin's Lymphoma: a Single Institute Experience

  • Ozdemir, Nuriye;Dogan, Mutlu;Sendur, Mehmet Ali Nahit;Yazici, Ozan;Abali, Huseyin;Yazilitas, Dogan;Akinci, Muhammed Bulent;Aksoy, Sercan;Zengi, Nurullah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.20
    • /
    • pp.8715-8718
    • /
    • 2014
  • Background: ABVD (doxorubicin, bleomycin, vinblastine (Vb) and dacarbazine) is the standard regimen in Hodgkin's lymphoma (HL).Vincristine (O) is a mitotic spindle agent like Vb. We aimed to evaluate the efficacy and safety of O as a part of ABOD in HL. Materials and Methods: Patients who had ABOD were enrolled. Stage I-II HL were evaluated for unfavorable risk factors according to NCCN. National Cancer Institute Common Toxicity Criteria was used for toxicity. Results: Seventy-nine HL patients in our center between 2003 and 2007 were evaluated retrospectively. Median follow-up was 54 months. Most of the patients were male in their third decade. Median ABOD cycles were 6 (2-8). Primary refractory disease rate was 17.7% whereas it was 5.1% for early relapse and 5.1% for late relapse disease. Response rates were as 82.3% for complete response, 11.4% for partial response, 5.1% for stable disease and 1.3% for progressive disease. Half of relapsed patients had autologous stem cell transplantation. Estimated 5-year failure-free survival was 71% and significantly longer in early stage patients without risk factors, bulky disease or radiotherapy (RT) (p=0.05, p<0.0001, p=0.02; respectively). Estimated 5-year overall survival was 74% and significantly longer in those who had no RT (p=0.001). Dose modification rate was 5.1% and chemotherapy delay rate was 19%. There were no toxicity-related deaths. Conclusions: ABOD seems to be effective with managable toxicity in HL, even in those with poor prognostic factors.

Evaluation of Renal Function Using the Level of Neutrophil Gelatinase-Associated Lipocalin is Not Predictive of Nephrotoxicity Associated with Cisplatin-Based Chemotherapy

  • Kos, F. Tugba;Sendur, Mehmet Ali Nahit;Aksoy, Sercan;Celik, Huseyin Tugrul;Sezer, Sevilay;Civelek, Burak;Yaman, Sebnem;Zengin, Nurullah
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.1111-1114
    • /
    • 2013
  • Background: For early detection of renal damage during the usage of cisplatin based chemotherapy, changes in renal function should be monitored carefully. In recent years, neutrophil gelatinase-associated lipocalin, a small polypeptide molecule, has shown promise as a marker of acute renal failure. The aim of this present study was to assess possible risk prediction of cisplatin-induced nephrotoxicity using serum NGAL. Materials and Methods: A total of 34 consecutive patients with documented serum creatinine at least 24 hours before every cycle of cisplatin-based chemotherapy were included in the study. Demographic and medical data including age, performance status, tumor characteristics and comorbid diseases were collected from medical charts. Renal function was evaluated at least 48 hours before the treatment and at the end of the treatment based on the Modification of Diet in Renal Disease (MDRD) formula. Before and after cisplatin infusion serum NGAL levels were measured for the first and 3rd cycles of chemotherapy. Results: The median age of the study population was 54 (32-70) years. Fifteen patients (41.1%) were treated on an adjuvant basis, whereas 19 patients (58.9%) were treated for metastatic disease. There was no correlation of serum NGAL levels with serum creatinine (r=0.20, p=0.26) and MDRD (r=-0.12, p=0.50) and creatinine clearance-Cockcroft-Gault (r=-0.22, p=0.22) after cisplatin infusion at the end of the 3rd cycle of chemotherapy. Conclusions: In our study, serum NGAL levels were not correlated with the cisplatin induced nephrotoxicity. Further prospective studies are needed to conclude that serum NGAL level is not a good surrogate marker to predict early cisplatin induced nephrotoxicity.

The Influence of Dynamic Strain Aging on Tensile and LCF Properties of Prior Cold Worked 316L Stainless Steel (냉간가공된 316L 스테인리스 강의 인장 및 저주기 피로 물성치에 미치는 동적변형시효의 영향)

  • Hong, Seong-Gu;Lee, Soon-Bok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.8
    • /
    • pp.1398-1408
    • /
    • 2003
  • Tensile and LCF(low cycle fatigue) tests were carried out in air at wide temperature range 20$^{\circ}C$-750$^{\circ}C$ and strain rates of 1${\times}$10$\^$-4//s-1${\times}$10$\^$-2/ to ascertain the influence of strain rate on tensile and LCF properties of prior cold worked 316L stainless steel, especially focused on the DSA(dynamic strain aging) regime. Dynamic strain aging induced the change of tensile properties such as strength and ductility in the temperature region 250$^{\circ}C$-600$^{\circ}C$ and this temperature region well coincided with the negative strain rate sensitivity regime. Cyclic stress response at all test conditions was characterized by the initial hardening during a few cycles, followed by gradual softening until final failure. Temperature and strain rate dependence on cyclic softening behavior appears to result from the change of the cyclic plastic deformation mechanism and DSA effect. The DSA regimes between tensile and LCF loading conditions in terms of the negative strain rate sensitivity were well consistent with each other. The drastic reduction in fatigue resistance at elevated temperature was observed, and it was attributed to the effects of oxidation, creep and dynamic strain aging or interactions among them. Especially, in the DSA regime, dynamic strain aging accelerated the reduction of fatigue resistance by enhancing crack initiation and propagation.

Serious Complications after Self-expandable Metallic Stent Insertion in a Patient with Malignant Lymphoma

  • Cho, Sung Bae;Cha, Seon Ah;Choi, Joon Young;Lee, Jong Min;Kang, Hyeon Hui;Moon, Hwa Sik;Kim, Sei Won;Yeo, Chang Dong;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • An 18-year-old woman was evaluated for a chronic productive cough and dyspnea. She was subsequently diagnosed with mediastinal non-Hodgkin lymphoma (NHL). A covered self-expandable metallic stent (SEMS) was implanted to relieve narrowing in for both main bronchi. The NHL went into complete remission after six chemotherapy cycles, but atelectasis developed in the left lower lobe 18 months after SEMS insertion. The left main bronchus was completely occluded by granulation tissue. However, the right main bronchus and intermedius bronchus were patent. Granulation tissue was observed adjacent to the SEMS. The granulation tissue and the SEMS were excised, and a silicone stent was successfully implanted using a rigid bronchoscope. SEMS is advantageous owing to its easy implantation, but there are considerable potential complications such as severe reactive granulation, stent rupture, and ventilation failure in serious cases. Therefore, SEMS should be avoided whenever possible in patients with benign airway disease. This case highlights that SEMS implantation should be avoided even in malignant airway obstruction cases if the underlying malignancy is curable.

Reliable experimental data as a key factor for design of mechanical structures

  • Brnic, Josip;Krscanski, Sanjin;Brcic, Marino;Geng, Lin;Niu, Jitai;Ding, Biao
    • Structural Engineering and Mechanics
    • /
    • v.72 no.2
    • /
    • pp.245-256
    • /
    • 2019
  • The experimentally determined mechanical behavior of the material under the prescribed service conditions is the basis of advanced engineering optimum design. To allow experimental data on the behavior of the material considered, uniaxial stress tests were made. The aforementioned tests have enabled the determination of mechanical properties of material at different temperatures, then, the material's resistance to creep at various temperatures and stress levels, and finally, insight into the uniaxial high cyclic fatigue of the material under different applied stresses for prescribed stress ratio. Based on fatigue tests, using modified staircase method, fatigue limit was determined. All these data contributes the reliability of the use of material in mechanical structures. Data representing mechanical properties are shown in the form of engineering stress-strain diagrams; creep behavior is displayed in the form of creep curves while fatigue of the material is presented in the form of S-N (maximum applied stress versus number of the cycles to failure) curve. Material under consideration was 18CrNi8 (1.5920) steel. Ultimate tensile strength and yield strength at room temperature and at temperature of $600^{\circ}C$: [${\sigma}_{m,20/600}=(613/156)MPa$; ${\sigma}_{0.2,20/600}=(458/141)MPa$], as well as endurance (fatigue) limit at room temperature and stress ratio of R = -1 : (${\sigma}_{f,20,R=-1}=285.1MPa$).