• Title/Summary/Keyword: Cycles To Failure

Search Result 423, Processing Time 0.03 seconds

Fatigue Life Analysis and Cooling Conditions Evaluation of a Piston for Large LPLi Bus Engines (LPG 액정분사식 대형 버스용 엔진 피스톤의 피로수명 해석과 냉각조건 평가)

  • 최경호;이부윤
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.762-772
    • /
    • 2004
  • Fatigue life of a Piston for large liquid Petroleum liquid injection(LPLi) bus engines is analyzed considering effects of cooling condition parameters : temperature of cooling water, and heat transfer coefficients at oil gallery and bottom surface of piston head. Temperature of the piston is analyzed with varying cooling conditions Stresses of the piston from two load cases of pressure loading. and pressure and thermal loading are analyzed Fatigue life under repeated peak pressure and thermal cycle is analyzed by the strain-life theory. For the two load cases, required loading cycles for engine life are defined, and loading cycles to failure and partial damages are calculated. Based on the resulting accumulated fatigue usage factors, endurance of the piston is evaluated and effects of varying cooling condition Parameters are discussed.

Multiple pregnancy after single or multiple embryo transfer performed according to Korean guidelines

  • Han, E Jung;Kim, Seul Ki;Lee, Jung Ryeol;Jee, Byung Chul;Suh, Chang Suk;Kim, Seok Hyun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.42 no.4
    • /
    • pp.169-174
    • /
    • 2015
  • Objective: To assess compliance with Korean guidelines for embryo transfer, the possible reasons for non-compliance, and multiple pregnancies according to each specific condition in compliant cycles. Methods: A single-institution, retrospective study was conducted of 256 fresh in vitro fertilization cycles during 2012-2014. To assess compliance with Korean guidelines, the maximum recommended number of embryos transferred (according to criteria of age, transfer day, and presence of favorable conditions) was compared with the actual number of embryos transferred. Clinical pregnancy rate (PR) was assessed as the percentage of pregnant women resulting from each set of transfer conditions, including the number of embryos transferred. The multiple pregnancy rate (MPR) was calculated as the percentage of pregnant women with a multifetal pregnancy. Results: The compliance rate with the Korean guidelines was 96.5% (247/256). Non-compliance occurred in nine cycles owing to poor embryo quality, repeated implantation failure, or hostile endometrium. In compliant cycles, the PR was 31.2% (77/247), and the MPR was 27.3% (21/77; 20 twins and one triplet). Higher MPR was noted in two types of transfer conditions: transfer of three cleavage embryos in women aged 35-39 years with favorable conditions (66.7%; primarily from those aged 35-37 years) and transfer of two blastocysts in women aged ${\geq}40$ years with favorable conditions (50%). Conclusion: Under the Korean guidelines, compliance rate was high in our center. Multiple pregnancies occurred primarily in group with favorable conditions. In high-risk groups for multiple pregnancies, reducing number of embryos transferred should be considered than suggested in the guideline.

The effect of different cooling rates and coping thicknesses on the failure load of zirconia-ceramic crowns after fatigue loading

  • Tang, Yu Lung;Kim, Jee-Hwan;Shim, June-Sung;Kim, Sunjai
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.152-158
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the influence of different coping thicknesses and veneer ceramic cooling rates on the failure load of zirconia-ceramic crowns. MATERIALS AND METHODS. Zirconia copings of two different thicknesses (0.5 mm or 1.5 mm; n=20 each) were fabricated from scanning 40 identical abutment models using a dental computer-aided design and computer-aided manufacturing system. Zirconia-ceramic crowns were completed by veneering feldspathic ceramics under different cooling rates (conventional or slow, n=20 each), resulting in 4 different groups (CONV05, SLOW05, CONV15, SLOW15; n=10 per group). Each crown was cemented on the abutment. 300,000 cycles of a 50-N load and thermocycling were applied on the crown, and then, a monotonic load was applied on each crown until failure. The mean failure loads were evaluated with two-way analysis of variance (P=.05). RESULTS. No cohesive or adhesive failure was observed after fatigue loading with thermocycling. Among the 4 groups, SLOW15 group (slow cooling and 1.5 mm chipping thickness) resulted in a significantly greater mean failure load than the other groups (P<.001). Coping fractures were only observed in SLOW15 group. CONCLUSION. The failure load of zirconia-ceramic crowns was significantly influenced by cooling rate as well as coping thickness. Under conventional cooling conditions, the mean failure load was not influenced by the coping thickness; however, under slow cooling conditions, the mean failure load was significantly influenced by the coping thickness.

An Experimental Study on Fatigue Behavior of High Strength Reinforced Concrete Beams (고강도 철근콘크리트 보의 피로거동에 관한 실험적 연구)

  • 임채영;박종건;곽계환
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.113-118
    • /
    • 1998
  • The relation of cycle loading to deflections on the mid-span, the crack propagation and the modes of failure according to cycle number, fatigue life and S-N curve were observed through the fatigue test. Based on the fatigue test results, high-strength reinforced concrete beams failed to 57 ~ 66 percent of the static ultimate strength. Fatigue strength about two million cycles from S-N curves was certified by 60 percent of static ultimate strength.

  • PDF

Effect of cumulative seismic damage to steel tube-reinforced concrete composite columns

  • Ji, Xiaodong;Zhang, Mingliang;Kang, Hongzhen;Qian, Jiaru;Hu, Hongsong
    • Earthquakes and Structures
    • /
    • v.7 no.2
    • /
    • pp.179-199
    • /
    • 2014
  • The steel tube-reinforced concrete (ST-RC) composite column is a novel type of composite column, consisting of a steel tube embedded in reinforced concrete. The objective of this paper is to investigate the effect of cumulative damage on the seismic behavior of ST-RC columns through experimental testing. Six large-scale ST-RC column specimens were subjected to high axial forces and cyclic lateral loading. The specimens included two groups, where Group I had a higher amount of transverse reinforcement than Group II. The test results indicate that all specimens failed in a flexural mode, characterized by buckling and yielding of longitudinal rebars, failure of transverse rebars, compressive crushing of concrete, and steel tube buckling at the base of the columns. The number of loading cycles was found to have minimal effect on the strength capacity of the specimens. The number of loading cycles had limited effect on the deformation capacity for the Group I specimens, while an obvious effect on the deformation capacity for the Group II specimens was observed. The Group I specimen showed significantly larger deformation and energy dissipation capacities than the corresponding Group II specimen, for the case where the lateral cyclic loads were repeated ten cycles at each drift level. The ultimate displacement of the Group I specimen was 25% larger than that of the Group II counterpart, and the cumulative energy dissipated by the former was 2.8 times that of the latter. Based on the test results, recommendations are made for the amount of transverse reinforcement required in seismic design of ST-RC columns for ensuring adequate deformation capacity.

Influence of Sperm Parameters and Capacitation Methods on the Outcome of Subzonal Insemination(SUZI) (투명대하 미세수정(SUZI)시 정자의 상태 및 처리방법에 따른 수정률과 임신률)

  • Choi, Kyoo-Wan;Kim, Soo-Kyung;Yang, Hyun-Won;Cha, Young-Beom;Lee, Seung-Jae;Park, Jong-Min;Kim, Moon-Kyoo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 1994
  • Subzonal insemination(SUZI) has been proposed for patients with severe male factor and previous fertilization failure. However, very low fertilization rates still persisted. The aims of this study were firstly, to examine the relationships between the fertilization rate and sperm parmeters, sperm incubation media and time, secondly, to evaluate the outcome of 119 cycles of SUZI applied the modified sperm preparation method. The fertilization rates were influenced more sensitively by sperm preincubation media and time than by sperm parameters. According to preincubation media and time, the fertilization rates were 43.3% in 50% follicular fluid (HFF), 36.6% in 10% fetal cord serum(FCS), and with the time, increased in FCS, but decreased in HFF. In regrd with sperm parameters, the fertilization rates were 42.9% in normal and 37.6% in subnormal group. The best results were obtained from SUZI by the spermatozoa incubated in 50% HFF for 6-8 hours. So we tried 119 cycles of SUZI(normal; 39 cycles, subnormal; 80 cycles) using the preparation method of 6-8 hour incubation in 50% HFF. There were no signigicant differences in the fertilization rates between normal(125/269, 46.4%) and subnormal sperm(264/635, 41.6%). Contrary to the fertilization rates, pregnancy outcomes were different between both groups. Better results obtained from the subnormal group than the normal in the number of transferred embryos, that of good embryos, and developmental rate of the fertilized eggs. The pregnancy rates per transfer were totally 13.3%(13/98),20.0%(13/65) in subnormal group. In the normal group, 2 patients showed ${\beta}$-hCG positive, but resulted in chemical pregnancy. Of 13 clinical pregnancies, two aborted, 6 on-going, and 5 delivered. In conclusion, SUZI is an effective technique to overcome fertilization failure for male factor and unexplained. The fertilization rate is influenced by sperm parameters, sperm incubation media and time. Also the quality of oocytes might be important for pregnancy as same as that of sperm.

  • PDF

Post-Damage Repair of Prestressed Concrete Girders

  • Ramseyer, Chris;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.3
    • /
    • pp.199-207
    • /
    • 2012
  • Concrete is an economical construction material and for that reason it is widely used in buildings and infrastructures. The use of deicing salts, expansion joint failure, and freeze-thaw cycles have led to concrete bridge girders experiencing corrosion of steel reinforcement and becoming unsafe for driving. The goal of this research is to assess the effectiveness of current and possible repair techniques for the end region of damaged prestressed concrete girders. To do this, three American Association of State Highway and Transportation prestressed concrete girders were tested to failure, repaired, and retested. Three different repair materials were tested including carbon fiber, glass fiber, and surface mounted rods. Each different repair material was also tested with and without injected epoxy. Comparisons were then made to determine if injecting epoxy had a positive effect on stiffness and strength recovery as well as which repair type regained the largest percentage of original strength.

Shape Optimization for Opening Mode in Fracture Mechanics (열림 모드에 대한 형상 최적화)

  • 한석영;송시엽
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.40-45
    • /
    • 2001
  • The relationship between structural geometry and number of life cycles to failure is investigated to improve the fatigue life of structural components. The linear elastic fracture mechanics(LEFM) approach is integrated with shape optimal design methodology. The primary objective of this study is to decide an optimal shape for enhancing the life of the structure. The results from LEFM analyses are used in the fatigue model to predict the life of the structure before failure is occurred. The shape of the structure is optimized by using the growth strain method. Relevant issues such as problem formulation, finite element modeling are explained. Three design examples are solved, and the results show that, with proper shape changes, the life of structural systems subjected to fatigue loads can be enhanced significantly.

  • PDF

Fatigue Life Analysis of Composite Materials (복합재료의 피로수명 해석)

  • 이창수;황운봉;박현철;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.268-271
    • /
    • 1999
  • Fatigue life Prediction is investigated analytically based on the fatigue modulus concept. Fatigue modulus degradation rate at any fatigue cycle was assumed as a power function of number of fatigue cycles. New stress function describing the relation of initial fatigue modulus and elastic modulus was used to account for material non-linearity at the first cycle. It was assumed that fatigue modulus at failure is proportional to applied stress level. A new fatigue life prediction equation as a function of applied stress is proposed. The prediction was verified experimentally using cross-ply carbon/epoxy laminate (CFRP) tube.

  • PDF

Pattern of Ovulation in Korean Women with Premature Ovarian Failure (한국인 조기난소부전 여성의 배란양상)

  • Kim, Hye-Min;Kim, Jae-Ryoung;Choi, Eun-Joo;Park, Eun-Joo;Hong, Seo-Yu;Lee, Jin-Yong;Park, Won-Il
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • Objective: Significant portion of premature ovarian failure patients ovulate intermittently and even can achieve pregnancy. The clinical features and reproductive potentials of Korean women with premature ovarian failure have never been elucidated. The purpose of this study is to assess ovarian follicular growth and ovulatory potential. Methods: Complete medical records of fifteen women with idiopathic premature ovarian failure were reviewed retrospectively. Subjects with more than 6 ultrasonographic scans and 36 months of follow-up period were included. Once the ovarian follicle was found by ultrasonography, the follicular growth was serially monitored. The result of ovulation induction of 6 cycles in 4 patients were also evaluated. Rate of positive ovarian follicle by ultrasound, rate of natural follicular growth and response of ovulation induction were assessed. Results: Among the 15 patients, 6 women (40%) had ovarian follicle in random ultrasonography. But the chance of positive follicle per ultrasonography scan was 7% (8 out of 115 scans). One out of 6 women eventually ovulated during the follow-up scan. In remaining 5 subjects, size of follicles remained unchanged. None of 6 ovulation induction cycles resulted successful ovulation. Conclusion: Incidence of positive ovarian follicle in Korean premature ovarian failure patients is lower than that of Western counterpart. This result, however, could not be directly compared because of the differences of study design. The ovulation rate by medical ovulation induction in this group is 0%, which is worse than the reported success rate of Western studies.