• Title/Summary/Keyword: Cycle type society

Search Result 1,407, Processing Time 0.032 seconds

Influence of Dissolved Ions on Geochemical Dissolution of Uranium in KURT Granite (KURT 화강암 내 우라늄의 지화학적 용출특성에 미치는 용존이온의 영향)

  • Cho, Wan Hyoung;Baik, Min Hoon;Ryu, Ji-Hun;Lee, Jae Kwang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.281-290
    • /
    • 2018
  • In order to understand the long-term behavior of radionuclides in granite environments, geochemical behavior characteristics of uranium in granitic host rock of KURT (KAERI Underground Research Tunnel) were investigated by dissolution experiment with different reaction time and solutions. In the dissolution experiment, significantly increased dissolution levels of uranium from granite powder samples were identified during the reaction time of 0~10 days for reaction solutions ($UD-CO_3$ and UD-Bg) containing a large amount of $CO_3{^{2-}}$. On the other hand, significantly increased dissolution levels of uranium were also identified for reaction solutions containing Na and Ca after 60 days. Dissolution of uranium continuously increased in reaction solutions of $UD-CO_3$ ($44.61{\mu}g{\cdot}L^{-1}$), UD-Bg ($41.01{\mu}g{\cdot}L^{-1}$), UD-Na ($26.87{\mu}g{\cdot}L^{-1}$), UD-Ca ($20.26{\mu}g{\cdot}L^{-1}$), UD-CaSi ($17.03{\mu}g{\cdot}L^{-1}$), and UD-Si ($10.47{\mu}g{\cdot}L^{-1}$) in the experimental period of ~270 days. However, after day 270, dissolution of uranium showed a decreasing tendency. This is thought to have occurred because existing uranium in granite samples reached the limit of dissolution by interaction with reaction solutions. Concentrations of dissolved uranium and points of maximum concentration value were found to differ depending on the $CO_3{^{2-}}$ presence in the mixed reaction solution and on the geochemical type of the water. It is estimated that differences in the reaction rate between the granite sample and the reaction solution are due to the influence of dissolved ions in the reaction solution.

mRNA Expression Differences of uPA, uPAR in Eutopic Endometrium of Advanced Stage Endometriosis Patients (중증 자궁내막증 환자의 자궁내막과 정상인 자궁내막에서 uPA, uPAR mRNA 발현의 차이에 관한 연구)

  • Hur, Sung Eun;Lee, Ji Young;Lee, Woon Jung;Chung, Hye-Sung;Chung, Hye Won
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.33 no.4
    • /
    • pp.229-236
    • /
    • 2006
  • Objective: We investigated the expression of uPA and uPAR in eutopic endometrium of advanced stage endometriosis and control patients. Methods: The 33 endometriosis patients and 32 controls were enrolled. Endometrial samples were obtained from 65 premenopausal women aged 29-44 years, undergoing laparoscopic surgery or hysterectomy for non-malignant lesions. Sufficient samples were collected from 33 patients with endometriosis stage Ill and IV and 32 controls without endometriosis confirmed by laparoscopic surgery. The mRNA expression of uPA and uPAR from eutopic endometrium were analyzed by RT-QC PCR. Results: The mRNAs of uPA and uPAR were expressed in eutopic endometrium from endometriosis and normal controls throughout the menstrual cycle. Uterine endometrium from women with endometriosis expresses significantly (p<0.05) higher levels of u-PA mRNA than endometrium from normal women without endometriosis in the proliferative phase. There were no significant differences in expression of uPAR in eutopic endometrium between controls and endometriosis patients. Conclusion: These results suggest that eutopic endometrium from endometriosis patients may be more invasive and prone to peritoneal implantation because of greater u-PA mRNA expression than endometrium from women without endometriosis. Thus, increased proteolytic activity may be one etiology for the invasive properties of the endometrium resulting in the development of endometriosis.

Evaluation of X-ray System for Nondestructive Testing on Radioactive Waste Drums (방사성폐기물 드럼 비파괴 검사를 위한 X-ray 장비 평가)

  • Park, Jong-Kil;Maeng, Seong-Jun;Lee, Yeon-Ee;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.3
    • /
    • pp.189-203
    • /
    • 2008
  • The physical and chemical properties of radioactive waste drums, which have been temporarily stored on site, should be characterized before their shipment to a disposal facility in order to prove that the properties meet the acceptance guideline. The investigation of NDT(Nondestructive Test) method was figured out that the contents in drum, the quantitative analysis of free standing water and void fraction can be examined with X-ray NDT techniques. This paper describes the characteristics of X-ray NDT such as its principles, the considerations for selection of X-ray system, etc. And then, the waste drum characteristics such as drum type and dimension, contents in drum, etc. were examined, which are necessary to estimate the optimal X-ray energy for NDT of a drum. The estimation results were that: $(R)\acute{A}$ the proper X-ray energy is under 3 MeV to test the drums of 320 ${\beta}\S$ and less; $(R)\ddot{E}$ both X-ray systems of 450 keV and/or 3 MeV might be needed considering the economical efficiency and the realization. The number of drums that can be tested with 450 keV and 3 MeV X-ray system was figured out as 42,327 and 18,105 drums (based on storage of 2006. 12), respectively. Four testing scenarios were derived considering equipment procurement method, outsourcing or not, etc. The economical and feasibility assessment for the scenarios was resulted in that an optimal scenario is dependent on the acceptance guide line, the waste generator's policy on the waste treatment and the delivery to a disposal facility, etc. For example, it might be desirable that a waste generator purchases two 450 keV mobile system to examine the drums containing low density waste, and that outsourcing examination for the high density drums, if all NDT items such as quantitative analysis for 'free standing water' and 'void fraction', and confirmation of contents in drum have to be characterized. However, one 450 keV mobile system seems to be required to test only the contents in 13,000 drums per year.

  • PDF

Electrochemical Decontamination of Metallic Wastes Contaminated with Uranium Compounds (우라늄화합물로 오염된 금속폐기물의 전해제염)

  • 양영미;최왕규;오원진;유승곤
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.11-23
    • /
    • 2003
  • A study on the electrolytic dissolution of SUS-304 and Inconel-600 specimen was carried out in neutral salt electrolyte to evaluate the applicability of electrochemical decontamination process for recycle or self disposal with authorization of large amount of metallic wastes contaminated with uranium compounds generated by dismantling a retired uranium conversion plant in Korea. Although the best electrolytic dissolution performance for the specimens was observed in a Na2s04 electrolyte, a NaNO$_3$ neutral salt electrolyte, in which about 30% for SUS-304 and the same for Inconel-600 in the weight loss was shown in comparison with that in a Na$_2$SO$_4$ solution, was selected as an electrolyte for the electrochemical decontamination of metallic wastes with the consideration on the surface of system components contacted with nitric acid and the compatibility with lagoon wastes generated during the facility operation. The effects of current density, electrolytic dissolution time, and concentration of NaNO$_3$ on the electrolytic dissolution of the specimens were investigated. On the basis of the results obtained through the basic inactive experiments, electrochemical decontamination tests using the specimens contaminated with uranium compounds such as UO$_2$, AUC (ammonium uranyl carbonate) and ADU (ammonium diuranate) taken from an uranium conversion facility were performed in 1M NaNO$_3$ solution with the current density or In mA/$\textrm{cm}^2$. it was verified that the electrochemical decontamination of the metallic wastes contaminated uranium compounds was quite successful in a NaNO$_3$ neutral salt electrolyte by reducing $\alpha$ and $\beta$ radioactivities below the level of self disposal within 10 minutes regardless of the type of contaminants and the degree of contamination.

  • PDF

MicroRNA-23b is a Potential Tumor Suppressor in Diffuse Large B-cell Lymphoma (미만성 거대 B 세포 림프종(DLBCL)에서 microRNA-23b의 잠재적 종양 억제자로서의 효과)

  • Nam, Jehyun;Kim, Eunkyung;Kim, Jinyoung;Jeong, Dawoom;Kim, Donguk;Kwak, Bomi;Kim, Sang-Woo
    • Journal of Life Science
    • /
    • v.27 no.2
    • /
    • pp.149-154
    • /
    • 2017
  • Diffuse large B-cell lymphoma (DLBCL) is the most common type of non-hodgkin lymphoma. Advances in the chemotherapeutic treatment of this disease have improved the outcomes of DLBCL; nonetheless, many patients still die of DLBCL, and therefore, a better understanding of this disease and identification of novel therapeutic targets are urgently required. In a recent gene expression profiling study, PDE (phosphodiesterase) 4B was found to be overexpressed in chemotherapy-resistant tumors. The major function of PDE4B is to inactivate the second messenger cyclic 3',5' monophosphate (cAMP) by catalyzing the hydrolysis of cAMP to 5'AMP. It is known that cAMP induces cell cycle arrest and/or apoptosis in B cells, and PDE4B abolishes cAMP's effect on B cells. However, the mechanism by which PDE4B is overexpressed remains unclear. Here, we show that the aberrant expression of miRNA may be associated with the overexpression of this gene. The PDE4B 3' untranslated region (UTR) has three functional binding sites of miR-23b, as confirmed by luciferase reporter assays. Interestingly, miR-23b-binding sites were evolutionarily conserved from humans to lizards, implying the critical role of PDE4B-miR-23b interaction in cellular physiology. The ectopic expression of miR-2 3b repressed PDE4B mRNA levels and enhanced intracellular cAMP concentrations. Additionally, miR-23b expression inhibited cell proliferation and survival of DLBCL cells only in the presence of forskolin, an activator of adenylyl cyclase, suggesting that miR-23b's effect is via the downregulation of PDE4B. These results together suggest that miR-23b could be a therapeutic target for overcoming drug resistance by repressing PDE4B in DLBCL.

High-temperature Thermal Decomposition of Cs-adsorbed CHA-Cs and CHA-PCFC-Cs Zeolite System, and Sr-adsorbed 4A-Sr and BaA-Sr Zeolite System (Cs-흡착 CHA-Cs 및 CHA-PCFC-Cs 제올라이트계와 Sr-흡착 4A-Sr 및 BaA-Sr 제올라이트계의 고온 열분해)

  • Lee, Eil-Hee;Kim, Ji-Min;Kim, Hyung-Ju;Kim, Ik-Soo;Chung, Dong-Yong;Kim, Kwang-Wook;Lee, Keun-Young;Seo, Bum-Kyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.1
    • /
    • pp.49-58
    • /
    • 2018
  • For the immobilization of high-radioactive nuclides such as Cs and Sr by high-temperature thermal decomposition, this study was carried out to investigate the phase transformation with calcined temperature by using TGA (thermogravimetric analysis) and XRD (X-ray diffraction) in the Cs-adsorbed CHA (chabazite zeolite of K type)-Cs and CHA-PCFC (potassium cobalt ferrocyanide)-Cs zeolite system, and Sr-adsorbed 4A-Sr and BaA-Sr zeolite system, respectively. In the case of CHA-Cs zeolite system, the structure of CHA-Cs remained at up to $900^{\circ}C$ and recrystallized to pollucite ($CsAlSi_2O_6$) at $1,100^{\circ}C$ after undergoing amorphous phase at $1,000^{\circ}C$. However, the CHA-CFC-Cs zeolite system retained the CHA-PCFC-Cs structure up to $700^{\circ}C$, but its structure collapsed in $900{\sim}1,000^{\circ}C$, and then transformed to amorphous phase, and recrystallized to pollucite at $1,100^{\circ}C$. In the case of 4A-Sr zeolite system, on the other hand, the structure of 4A-Sr maintained up to $700^{\circ}C$ and its phase transformed to amorphous at $800^{\circ}C$, and recrystallized to Sr-feldspar ($SrAl_2Si_2O_8$, hexagonal) at $900^{\circ}C$ and to $SrAl_2Si_2O_8$ (triclinic) at $1,100^{\circ}C$. However, the BaA-Sr zeolite system structure began to break down at below $500^{\circ}C$, and then transformed to amorphous phase in $500{\sim}900^{\circ}C$ and recrystallized to Ba/Sr-feldspar (coexistence of $Ba_{0.9}Sr_{0.1}Al_2Si_2O_8$ and $Ba_{0.5}Sr_{0.5}Al_2Si_2O_8$) at $1,100^{\circ}C$. All of the above zeolite systems recrystallized to mineral phase through the dehydration/(decomposition) ${\rightarrow}$ amorphous ${\rightarrow}$ recrystallization with increasing temperature. Although further study of the volatility and leachability of Cs and Sr in the high-temperature thermal decomposition process is required, Cs and Sr adsorbed in each zeolite system are mineralized as pollucite, Sr-feldspar and Ba/Sr-feldspar. Therefore, Cs and Sr seen to be able to completely immobilize in the calcining wasteform/(solidified wasteform).

A Study on the Status of Recognition and Practical Application of Oral Hygiene Devices : with outpatient as the central figure (치과병·의원 내원환자의 구강위생용품에 대한 인지도 및 사용실태에 관한 연구)

  • Kim, Soo-Kyung
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • This study was carried out to investigate recognition level and practical application status of oral hygiene devices through making a survey of Seoul inhabitants. And survey was implemented in order to propose oral hygiene device for household health care activities. The following results were obtained by analyzing personal interviews of 347 commuting patients at two university hospitals and seven dental clinics. 1) The average length of toothbrush head was estimated as 22.3 mm and average changing cycle was 2.3 months. The user ratio of flat-headed brush was estimated as 51.9% and 46.7% were using fluoridated toothpaste. 2) Generally the ratio of toothpick users was higher than other device users. But the user ratio of dental floss was higher than toothpick in case of patients under orthodontic treatment. 3) The patients under orthodontic treatment were not familiar with handling orthodontic toothbrush. Though 45.8% among orthodontic patients recognized this type of toothbrush, only 25.4% of them knew how exactly to use it. 4) It was shown very low user ratio of oral hygiene devices that the patients who had periodontal problem, hypersensitive trouble, halitosis, implant or denture 5) The patients who had halitosis showed the highest user ratio of toothpick. The patients who had separation of teeth showed the highest user ratio of dental floss. The patients who're under orthodontic treatment showed the highest user ratio of interproximal brush and motorized brush. 6) In response to the most interesting dental disease, it's surveyed as follows; 60.3% of dental caries, 24.0% of periodontal disease, 14.8% of false occlusion and 0.9% of oral cancer. 7) Regarding the motivation of using those oral hygiene devices, 45% responded that it was because of recommendation by dental clinics. Among the negative answers, 38.6% responded that it was because of no selection guidance. 31.3% answered that they didn't use hygiene device because it's inconvenient. 12.0% answered that it's difficult to buy and expensive. 7.8% responded that they didn't feel significant improvement. 4.8% answered that dental hospitals and clinics didn't even introduce those hygiene devices. Therefore efficient campaign for those hygiene devices over all Korea nation should be developed and education program must be prepared for each case of patients in every dental hospitals and clinics.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

National Survey of Injury and Poisoning on a Representative Sample Population of Koreans (우리나라 대표적(代表的) 표본인구(標本人口)의 연간(年間) 손상(損傷) 및 중독발생율(中毒發生率)과 역학적(疫學的) 특성(特性))

  • Kim, Joung-Soon;Kim, Sung-Soo;Chang, Sung-Chill
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.447-463
    • /
    • 1994
  • Despite the public health importance of injury and poisoning in terms of its high mortality and incidence, epidemiologic information to be utilized are scarce in Korea. This study was carried out in 1990 on a representative sample population (about 55,000 persons) along with the 6th National Tuberculosis Prevalence Survey in order to estimate the magnitude of injury and poisoning occurrence and to identify its epidemiologic characteristics which can be aided for establishing preventive strategy. Pre-tested and structured Questionnaire was used by trained interviewer to collect data including general information of the person, various information on the injury and poisoning during the past one year such as time and place of its occurrence, its nature and external causes, type of medical institute attended, duration of treatment and outcome of the accident occured. In analysis of the data collected incidence rates per 1000 persons by sex, age group and its nature as well as external causes, and relative frequencies were calculated. The result obtained are as followings; 1. The incidence rate per 1000 was 30 for both sexes, 39 for male and 22 for female, male being 1.8 times more frequent than female. Age adjusted incidences were not much different from the crude rates. Age group specific rate curve showed bimodal shape in both sexes, small peaks in preschool children and higher peaks in older ages. The incidence rate per 1000 people by area was highest in Jeon-bug province (57/1000) and the lowest in Daegu city(11/1000). 2. The place where the injuries occured were road in 46%, within the boundary of house in 25%, and working place in 12% The injuries and poisoning had occured more frequently during the months from March to August of the year than other months. 3. The relatively frequent injuries by its nature were contusion with intact skin surface (19%), fracture of upper limb (13%), open wound of head, neck and trunk (12%) and fracture of lower limb (11%) among males; contusion with intact skin surface (28%), sprains and strains of joints and adjacent muscle (14%), fracture of upper limb (10%) and fracture of lower limb (9%) among females. Higher incidence rate among males than females were fracture of skull (4.5 times), open wound and fractures of limbs ($2{\sim}3$ times). Age specific rate of injuries and poisoning by its nature showed increasing pattern by age in fractures of upper and lower limbs and sprains & strains of joints whereas the age group of 30's showed highest incidence in open wounds of upper limb. Fractures of radius and ulna in upper limb, fractures of tibia & fibula and ankle in lower limb were most frequent among fractures of upper and lower limbs. The frequent injuries among sprains and strains of joints and adjacent muscles were that of ankle, foot and back, and among open wound were that of head and fingers. 4. Relative frequency of injuries and poisoning by external causes showed following order : other accidents (25%), accidental falls (23%), motor vehicle accident (22%) and other road vehicle accident (14%) among males and accidental falls (37%), motor vehicle accident (24%) and other accident (18%) among females. The external causes revealing higher incidences among males than females, were other road vehicle accident (4.8 times), vehicle accident not elsewhere classifiable (4.4 times), accidental poisoning (4.4 times), accidents due to natural and environmental factors (2.8 times), and sucide & self-inflicted injuries (2.8 times). Age specific incidence by external causes for frequent injuries showed that incidence of other accident steadily increased from 10's till age 50's; motor vehicle traffic accident increased from age 20's and dropped after age 60's; on the other hand accidental fall increased strikingly by age. The most frequent external causes among motor vehicle traffic accidents was motor vehicle traffic accident involving collision with pedstrain (69%), pedal cycle accident (30%) and other road vehicle accident (71%) among other road vehicle accidents; falls on same level from slipping, tripping or standing (44%) and other falls from one level to another among accidental falls; accidents caused by machinary (32%) for male and striking against or struck accidentally by objects or person for female among other accidents. 5. Seventy nine percent of the injuries and poisonings were treated in general hospital or hospital/clinic. The duration of treatment ranged from a few days to 123 weeks; the majority(52%) took under 2 weeks, 36% for $3{\sim}8$ weeks and 4% over 21 weeks. 6. The accident resulted in full recovery of normal healthy state in 62%, residual functional defects in 21% and on process of treatment in 16%.

  • PDF

A Study for the Methodology of Analyzing the Operation Behavior of Thermal Energy Grids with Connecting Operation (열 에너지 그리드 연계운전의 운전 거동 특성 분석을 위한 방법론에 관한 연구)

  • Im, Yong Hoon;Lee, Jae Yong;Chung, Mo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.3
    • /
    • pp.143-150
    • /
    • 2012
  • A simulation methodology and corresponding program based on it is to be discussed for analyzing the effects of the networking operation of existing DHC system in connection with CHP system on-site. The practical simulation for arbitrary areas with various building compositions is carried out for the analysis of operational features in both systems, and the various aspects of thermal energy grids with connecting operation are highlighted through the detailed assessment of predicted results. The intrinsic operational features of CHP prime movers, gas engine, gas turbine etc., are effectively implemented by realizing the performance data, i.e. actual operation efficiency in the full and part loads range. For the sake of simplicity, a simple mathematical correlation model is proposed for simulating various aspects of change effectively on the existing DHC system side due to the connecting operation, instead of performing cycle simulations separately. The empirical correlations are developed using the hourly based annual operation data for a branch of the Korean District Heating Corporation (KDHC) and are implicit in relation between main operation parameters such as fuel consumption by use, heat and power production. In the simulation, a variety of system configurations are able to be considered according to any combination of the probable CHP prime-movers, absorption or turbo type cooling chillers of every kind and capacity. From the analysis of the thermal network operation simulations, it is found that the newly proposed methodology of mathematical correlation for modelling of the existing DHC system functions effectively in reflecting the operational variations due to thermal energy grids with connecting operation. The effects of intrinsic features of CHP prime-movers, e.g. the different ratio of heat and power production, various combinations of different types of chillers (i.e. absorption and turbo types) on the overall system operation are discussed in detail with the consideration of operation schemes and corresponding simulation algorithms.