실리카겔-물계 흡착식 냉동기 사이클 시뮬레이션 (Cycle Simulation of an Adsorption Chiller Using Silica Gel-water)

  • 권오경;윤재호
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.116-124
    • /
    • 2007
  • An adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objective of this paper is to investigate the performance of silica gel-water adsorption chiller from the cycle simulation and to provide a guideline for design of the adsorption chiller. The effect of cycle time, inlet temperature and water flow rate on the cooling capacity and COP is quantified during the cycle operation. It is found that the performance of adsorption chiller is more sensitive to the change of inlet water temperature rather than the water flow rate. It is concluded that the COP is 0.57 in the standard conditions(hot water $80^{\circ}C$, cooling water $30^{\circ}C$, chilled water inlet temperatures $14^{\circ}C$ and cycle time 420sec).

지속적 프로세스 개선을 위한 성과 중심의 생애 주기 기반 비즈니스 프로세스 관리 프레임워크 (A Life Cycle-Based Performance-Centric Business Process Management Framework For Continuous Process Improvement)

  • 한관희
    • 한국콘텐츠학회논문지
    • /
    • 제17권7호
    • /
    • pp.44-55
    • /
    • 2017
  • 최근에 많은 기업들이 기업 목표를 달성하기 위해 프로세스 혁신이나 개선을 지속적으로 꾀하고 있으며, 이를 지원하는 도구로 BPM (Business Process Management)이 많이 도입되고 있다. BPM의 생애 주기는 프로세스 진단, (재)설계 및 실행으로 이루어지는데, 모든 BPM 활동들은 성과 척도와 밀접한 관련을 갖고 운영되어야 한다. 본 논문의 목적은 프로세스 기반 성과 측정 모델과 통합된 생애 주기 기반 BPM 프레임워크를 제안하는 것이다. 제안 프레임워크에서는 BPM 전 생애 주기 동안 비즈니스 프로세스와 성과 척도가 체계적인 상관관계를 가지고 밀접하게 운영된다. 기업의 혁신이나 개선 담당자들은 제안 프레임워크를 사용하여 프로세스 진단 단계에서는 기업 성과에 가장 영향을 주는 프로세스를 용이하게 확인할 수 있고, 프로세스 (재)설계 단계에서는 새롭게 설계된 프로세스의 성과를 측정할 수 있으며, 프로세스 실행 단계에서는 성과 척도를 모니터하여 비즈니스 활동 들을 조정할 수 있게 된다.

3단압축 드라이아이스 제조사이클의 압축동력과 엑서지 해석 (Compression Power and Exergy Analysis in a Dry Ice Production Cycle with 3-stage Compression)

  • 이근식
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.550-560
    • /
    • 2000
  • In order to minimize compression power and analyze the cause of exergy loss for a dry ice production cycle with 3-stage compression, the variation of compression power was investigated and the exergy analysis was peformed for the cycle. In this cycle, $CO_2$, is used both as a refrigerant and as a raw material for dry ice. The behavior of compression power and irreversibility in the cycle were examined as a function of intermediate pressure. From this result, the conditions for the minimum compression power were obtained in terms of the first stage or the third stage pressure. In addition, the irreversibilities for the cycle were investigated with respect to the efficiency of compressor. Result shows that the optimum pressure is not consistent with the conventional pressure obtained from the equal-pressure-ratio assumption. This is mainly due to the change in mass flow rate of the intermediate stage compressor by the flash gas evaporation from the flash drums. Most important is that the present exergy analysis enabled us to find bad performance components for the cycle and informed us of methods to improve the cycle performance.

  • PDF

저온열원의 특성에 따른 ORC 성능해석 최적화 연구 (Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources)

  • 엄홍선;윤천석;김영민;신동길;김창기
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.

2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구 (Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle)

  • 류창기;이호성;김용찬;조흥현;조성욱
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

항공기 외장형 정찰 장비용 냉각 시스템의 성능 특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of Cooling System for Aircraft External Reconnaissance Stores)

  • 정대윤;이행복
    • 한국군사과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.74-80
    • /
    • 2013
  • In this paper, we have proposed a vapor cycle refrigeration system as a cooling system to provide cooling air to the aircraft external reconnaissance stores. In the proposed vapor cycle system, receiver which prevents refrigerant from subcooling was eliminated and thermal expansion valve was replaced with electronic expansion valve. The vapor cycle refrigeration system is aimed to provide cooling air to the reconnaissance stores which is added to the aircraft in the form of external store. The wide temperature range of ambient air from the flight conditions can decrease the cooling performance and can make the refrigeration system unstable in low ambient temperature. Performance characteristics of the vapor cycle refrigeration system has been experimented under air conditions which is derived from the flight envelope. From the experiments, the vapor cycle refrigeration system has been proved to provide enough cooling air to the reconnaissance equipment and to be stable under all the flight conditions.

흡수압축 하이브리드 히트펌프 사이클의 성능특성 (Performance Characteristic of the Compression-Absorption Hybrid Heat Pump Cycles)

  • 윤정인;권오경;양영명
    • 한국가스학회지
    • /
    • 제3권1호
    • /
    • pp.14-20
    • /
    • 1999
  • [ $H_2O/LiBr$ ]계 흡수식 사이클에 압축기를 조합한 흡수압축사이클을 도입하여 증기를 단열압축시켜 그 증기의 응축열을 재생열로 이용하는 사이클에 대해서 시뮬레이션을 통하여 횹수압축사이클의 특성을 밝힌 연구이다. 기존의 흡수사이클에 압축기를 도입함에 따라 고효율 사이클을 실현할 수 있음을 제시하였으며, 흡수$\cdot$압축사이클의 구체적인 가능성을 제시하였다. 재생기에서 발생한 냉매증기를 단열압축시킨 TYPE 2는 단열압축 증기의 응축열만으로는 재생이 어려우므로 외부로부터 별도의 열량을 투입해야 하며 투입하는 외부열량에 폐열이나 2차 에너지를 이용할 수 있다면 높은 COP를 얻을 수 있어 실현가능성이 높다.

  • PDF

천연냉매를 사용하는 내부 열교환기 부착 캐스케이드 냉동시스템의 성능 특성 분석 (Analysis of Performance Characteristics of a Cascade Refrigeration System with Internal Heat Exchanger using Natural Refrigerants)

  • 손창효;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권8호
    • /
    • pp.1123-1128
    • /
    • 2009
  • 이 논문은 천연냉매를 사용하는 내부 열교환기 부착 캐스케이드 냉동시스템의 작동변수에 대한 기초 설계자료를 제공하기 위해서 본 사이클 성능 특성을 파악하고자 한다. 이 사이클은 R290, R1270, R600a 그리고 에탄과 같은 냉매를 사용하는 저온사이클과 이산화탄소를 사용하는 고온사이클로 구성된다. 주요결과를 요약하면 다음과 같다. 고온측 사이클에는 R744 냉매를, 저온측 사이클에는 R600a를 적용할 경우 가장 높은 성적계수를 나타내었고, 내부 열교환기의 설치 위치에 대한 부분에 대해서는 고온측 사이클에만 내부 열교환기를 설치할 경우 캐스케이드 냉동시스템의 성적계수가 가장 높게 나타났다.

Kalina 사이클의 효율 향상 방안 및 성능 비교 (Improvement of Efficiency of Kalina Cycle and Performance Comparison)

  • 윤정인;손창효;최광환;손창민;설성훈;이호생;김현주
    • 한국태양에너지학회 논문집
    • /
    • 제35권5호
    • /
    • pp.11-19
    • /
    • 2015
  • In this paper, EP-Kalina cycle applying liquid-vapor ejector and motive pump is newly proposed. In this EP-Kalina cycle, the liquid-vapor ejector is used to increase pressure difference between inlet and outlet of the turbine. Also the motive pump enhances the performance of liquid-vapor ejector, resulting in increase of system efficiency of OTEC cycles. The comparison cycles in this study are basic, Kalina, EKalina and EP-Kalina ones. The pump work, net power, APRe, APRc, TPP and system efficiency of each cycle are compared. In case of net power, EP-Kalina cycle is lowest among the cycles due to the application of the motive pump. But, the net power difference of cycles seems to be minor since the pump work of cycles is merely about 1kW, compared to turbine gross power of 20kW. The system efficiency of EP-Kalina cycle shows 3.22%, relatively 44% higher than that of basic OTEC cycle. Therefore, the system efficiency is increased by applying the liquid-vapor ejector and the motive pump. Additional performance analysis is necessary to optimize the proposed EP-Kalina cycle.

단지내 도로포장별 생애주기 비용 분석(LCCA) 사례 연구 (A Case Study of Life Cycle Cost Analysis on Pavements in Apartment Complex)

  • 정종석;박용부;손정락
    • 토지주택연구
    • /
    • 제5권4호
    • /
    • pp.297-303
    • /
    • 2014
  • 최근, 공동주택 단지내 투수성 포장 및 블록포장 등과 같은 포장이 많이 시공되고 있으나 품질관리와 공용성 평가에 관한 기준이 미비하여 하자 교체 및 교체주기 시기 결정 등에 어려움이 많은 실정이다. 따라서, 본 연구에서는 공동주택에 많이 적용되고 있는 투수성포장 및 블록 포장의 합리적 선정기준을 제안하기 위해 교체주기, 초기 공사비, 유지교체비용 등을 고려한 포장공법별 생애주기 비용 분석(LCCA)을 실시하였다. 생애주기비용 분석결과는 교체주기 20년이상인 인터록킹 콘크리트 블록포장이 최적의 대안이지만, 보도 포장의 교체기준 10년을 기준으로 하였을 경우 최적의 대안은 일반적인 아스팔트 콘크리트 포장임을 알 수가 있다. 따라서, 교체주기가 대안의 선정 및 생애주기비용 분석에 많은 영향을 미치므로 향후, 교체주기의 객관적인 정량화에 필수적인 공용성 지수 개발이 필요하다.