• Title/Summary/Keyword: Cycle frequency

Search Result 1,053, Processing Time 0.032 seconds

New Design of Duty Cycle Controllable CMOS Voltage-Controlled Oscillator for Low Power Systems (Duty Cycle 조정이 가능한 새로운 저전력 시스템 CMOS Voltage-Controlled Oscillator 설계)

  • Cho, Won;Lee, Sung-chul;Moon, Gyu
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.605-606
    • /
    • 2006
  • Voltage Controlled Oscillator(VCO) plays an important role in today's communication systems. Especially, a Clock Generator(CG) in phase-locked loop(PLL) is usually realized by the VCO. This paper proposes a new VCO with a controllable duty cycle buffer, that can be adopted in low-power high-speed communication systems. Delay cell of the VCO is implemented with gilbert cell. Frequency dynamic range of the VCO is in the range of approximately $50MHz{\sim}500MHz$. Parameters with N-well CMOS 0.18-um process with 1.8V supply voltage was used for the simulations.

  • PDF

A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination (복합발전기 조합별 증분비 곡선 재설정에 관한 연구)

  • Hong, Sang-Beom;Choi, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

Static and Dynamic Analysis of Automotive Steering System (자동차 조향 장치의 정적 및 동적 응력해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.3
    • /
    • pp.36-40
    • /
    • 2008
  • This study is analyzed by the simulation of automotive steering system. The maximum equivalent stress of $2.2418{\times}109Pa$ and the maximum total displacement of 0.014929m are shown at the universal joint and its lower part respectively. As the minimum cycle of 34.047 is shown at the universal joint in case of fatigue analysis, it is possible to have greatest damage at this part. In case of natural frequency analysis at vibration, its frequency of 47 to 59Hz is occurred generally. The maximum total displacement of 0.5m is shown at handle on the natural frequency of 57 to 58Hz. And the displacement over 2m is shown at the lower part of universal joint on the natural frequency of 58 to 59Hz. As the basis of the simulation analysis of steering system, passenger's comfort of car body can be improved in the design of practical part and the design effect necessary to safe driving can be promoted.

  • PDF

Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application (유도가열기용 직.병렬 공진 고주파 인버터의 설계)

  • 홍순일;손의식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF

Nonstationary Frequency Analysis of Hydrologic Extreme Variables Considering of Seasonality and Trend (계절성과 경향성을 고려한 극치수문자료의 비정상성 빈도해석)

  • Lee, Jeong-Ju;Kwon, Hyun-Han;Moon, Young-Il
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.581-585
    • /
    • 2010
  • This study introduced a Bayesian based frequency analysis in which the statistical trend seasonal analysis for hydrologic extreme series is incorporated. The proposed model employed Gumbel and GEV extreme distribution to characterize extreme events and a fully coupled bayesian frequency model was finally utilized to estimate design rainfalls in Seoul. Posterior distributions of the model parameters in both trend and seasonal analysis were updated through Markov Chain Monte Carlo Simulation mainly utilizing Gibbs sampler. This study proposed a way to make use of nonstationary frequency model for dynamic risk analysis, and showed an increase of hydrologic risk with time varying probability density functions. In addition, full annual cycle of the design rainfall through seasonal model could be applied to annual control such as dam operation, flood control, irrigation water management, and so on. The proposed study showed advantage in assessing statistical significance of parameters associated with trend analysis through statistical inference utilizing derived posterior distributions.

  • PDF

A New Control Scheme for a Class-D Inverter with Induction Heating Jar Application by Constant Switching Frequency

  • Choi Won-Suk;Park Nam-Ju;Lee Dong-Yun;Hyun Dong-Seok
    • Journal of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.272-281
    • /
    • 2005
  • In this paper, a simple power control scheme for a constant frequency Class-D inverter with a variable duty cycle is proposed. It is more suitable and acceptable for high- frequency induction heating (IH) jar applications. The proposed control scheme has the advantages of not only wide power regulation range but also ease of control output power. Also it can achieve a stable and efficient Zero-Voltage-Switching (ZVS) in a whole load range. The control principles of the proposed method are described in detail and its validity is verified through simulated and experimental results on 42.8kHz IGBT for induction heating rated on 1.6kW with constant frequency variable power.

A Study on Frequency Simulator Design for Load Following Test of Generator (발전기 부하추종성 시험용 주파수 Simulator 설계에 관한 연구)

  • Kwak, Wol-Hwan;Lee, Gang-Wan;Oh, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.138-142
    • /
    • 2004
  • Recently over dropped frequencies of power system were recorded when power system was unbalanced between generation and demand. Therefore load following characteristic analysis of thermal and combined cycle power plant generators is necessary for low frequency condition analysis of power system. Frequency simulator supplies simulated frequency to the online generator for prescribed goal. This simulator needs to minimize effects to power system and requires stability first. This paper introduces design and manufacturing case of frequency simulator for load following characteristic analysis of generators.

  • PDF

100W On-Board Power Supply Using Flat Transformer (Flat Transformer를 이용한 100W급 On-Board Power Supply)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

Single Phase Utility Frequency AC-High Frequency AC Matrix Converter Using One-Chip Reverse Blocking IGBTs based Bidirectional Switches

  • Hisayuki, Sugimura;Kwon, Soon-Kurl;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.125-128
    • /
    • 2006
  • This paper presents a novel type soft switching PWM power frequency AC-AC converter using bidirectional active switches or single phase utility frequency AC-high frequency AC matrix converter. This converter can directly convert utility frequency AC (UFAC, 50Hz/60Hz) power to high frequency AC (HFAC) power ranging more than 20kHz up to 100kHz. A novel soft switching PWM prototype of high frequency multi-resonant PWM controlled UFAC-HFAC matrix converter using antiparallel one-chip reverse blocking IGBTs manufactured by IXYS corp. is based on the soft switching resonance with asymmetrical duty cycle PWM strategy. This single phase UFAC-HFAC matrix converter has some remarkable features as electrolytic capacitor DC busline linkless topology, unity power factor correction and sine-wave line current shaping, simple configuration with minimum circuit components, high efficiency and downsizing. This series load resonant UFAC-HFAC matrix converter, incorporating bidirectional active power switches is developed and implemented for high efficiency consumer induction heated food cooking appliances in home uses and business-uses. Its operating performances as soft switching operating ranges and high frequency effective power regulation characteristics are illustrated and discussed on the basis of simulation and experimental results.

  • PDF

A study for Menu Life Cycle of Hotel Restaurants (호텔레스토랑의 메뉴수명주기 (Menu Life Cycle)에 관한 연구)

  • 송청락
    • Culinary science and hospitality research
    • /
    • v.2
    • /
    • pp.59-87
    • /
    • 1996
  • This study has been done by giving the guide when development of menu or doing marketing strategy in Hotel Restaurant. All products and service has a regular course from induction in market to disappear, so it shall be come out Products Life Cycle theory. In eating business, under the tendency and existing cycle to change menu by taste of customers, liking variation, change of periodic status (environment), MLC(Menu Life Cycle) shall be advised by application PLC(Products Life Cycle) in the process of induction of some menu first and spreading the same business field and then deletion (disappearance) from menu because of no popular. In Emergence Stage, it shall be tried to inform new menu through Cooking Contest, presentation of new menu, free sampling party and others. In Growth Stage, it shall be changed package menu or set menu. In Maturity Stage, it shall be provided complimentary ticket, gift coupon or discount for the customers with some degree of selling record in order to increase using frequency and selling amount after insure new customers. In Decline Stage, it shall be groped for entry underdeveloped country or less advance nation, but there is no possibility to devote in enterprise, it shall be planned substitute menu development in order to withdraw. By inducting MLC concept, it shall be provided the available informations such as“how could some menu be circulate in some restaurant”“Accordingly do strengthen promotion activities or go to low developed area or overseas, or delete it from menuitems and so on”. In the time of decline some menu, it is judged to the time of plan(preparation) of new menu development. In the broad view, when consideration of the concept of menu life cycle, it shall be possible to know which menu is decayed and which menu is developed newly or grown-up, so it shall be provided the important information to estimate the tendency of changing menu and set-up a menu development plan.

  • PDF