• Title/Summary/Keyword: Cycle Times

Search Result 1,401, Processing Time 0.025 seconds

Fatigue CAE Analysis of a Rebar Bending Machine Roller (철근 밴딩기 롤러의 피로파괴 CAE 해석)

  • Shin, Yu-Jeong;CHoi, Chang-Hwan;Lee, Sung-gun;Kim, Jin-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • The rebar factory production process involves the repetitive bending of rebars. Therefore, the fatigue failure of the rebar bending machine needs to be considered. In this paper, fatigue analysis of the rebar machine was performed using the commercial software DAFUL, which is based on MFBD (Multi Flexible Body Dynamics). The rotating roller, fixing roller and rebar were modeled by the finite element method. The rebar bending process is simulated and the mechanical stresses on the rollers are calculated. Structural analysis of the rebar bending roller was performed using the maximum bending angle of $180^{\circ}$ and maximum processing rebar diameter of ${\Phi}19mm$. Then, for fatigue analysis, the S-N curve of STD-11 was. The fatigue life of rollers is estimated by modified Goodman diagram. The fatigue life range of the rotating roller is $2.99961{\times}10^5{\sim}1{\times}10^8$ while that of the fixed roller is $2.53142{\times}10^5{\sim}1{\times}10^8$. STD-11 has an infinite life cycle after $1{\times}10^8$. Therefore, the rollers of the rebar bending machine may be expected to suffer fatigue failure. Thus, we performed a parameter study of fatigue life according to various axial radii of the fixed roller and rotating roller, and redesign of the rebar bending machine. Consequently, the axial radius of the fixed roller and rotating roller was found to be 35~37.5mm and 30~35mm, respectively, and an infinite life cycle was confirmed at these.

A Design of High Performance Operation Intra Predictor for H.264/AVC Decoder (H.264/AVC 복호기를 위한 고성능 연산처리 인트라 예측기 설계)

  • Jin, Xianzhe;Ryoo, Kwangki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.11
    • /
    • pp.2503-2510
    • /
    • 2012
  • This paper proposes a parallel operation intra predictor for H.264/AVC decoder. In previous intra predictor design, common operation units were designed for 17 prediction modes in order to compute more effectively. However, it was designed by analyzing the equation applied to one pixel. So, there are four operation units for computing 16 pixels in a $4{\times}4$ block and they need four cycles. In this paper, the proposed intra predictor contains T3(Three Type Transform) operation unit for parallel operation. It divides 17 modes into 3 types to calculate 16 pixels of a $4{\times}4$ block in only one cycle and needs 16 cycles minimum in 16x16 block. As the result of the experiment, in terms of processing cycle, the performance of proposed intra predictor is 58.95% higher than the previous one.

A Study on Durability of Automotive Propeller Shaft by Fatigue and Vibration (피로 및 진동에 의한 자동차 추진축의 내구성 연구)

  • Cho, Jae-Ung;Kim, Sei-Hwan;Kim, Key-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1495-1501
    • /
    • 2011
  • Fatigue life and vibration can be analyzed at automotive propeller shaft during driving in this study. The york part is shown with the maximum equivalent stress and displacement of $1.3177{\times}10^3$Pa and $3.6148{\times}10^{-4}$m. The possible life in use in case of 'SAE bracket' is the shortest among the fatigue loading lives of 'SAE bracket', 'SAE transmission' and Sample history. There are the most frequency as 80% in case of 'SAE bracket and the least frequency as 5% in case of Sample history'. Maximum amplitude displacement is 0.00261m at 58 Hz at forced vibration. As the result of this study is applied by the propeller shaf, the prevention on fatigue damage and the durability are predicted.

A Study on Annealing Cycle Control Temperature of Hi - CON/2 BAF and HNx BAF (Hi-CON/H2 BAF와 HNx BAF의 소둔사이클 제어온도에 관한 연구)

  • 김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.114-122
    • /
    • 1994
  • A cold temperature control system for the BAF(batch annealing furnace) has been established in order to reduce energy consumption to imrpove productivity and stabilize the properties of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, changing annealing cycle time according to BAF temperature with time during heating and actual temperature measurements cold spot during soaking. The results of the temperature variation effect on the batch annealing are as follows. 1) Cooling rate is increasing gradually with increasing atmospheric gas flow, but heating rate is hardly increasing without atmospheric gas component. Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas and annealing cycle time is reduce to 2.7 times. 2) With enlarging the difference between furnace temperature and soaking temperature at the HNx BAF, heating time becomes short, but cooling time is indifferent. 3) If temperature difference of 300.deg. C in the temperature change of cold spot according to the annealing cycle control temperature, Hi-CON/H2BAF is interchanging at each other at 26hours, but HNxBAF at 50 hours. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1219 mm width coil must be 2.5 hours longer then that of 914mm width coil for the same coil weight at Hi-CON/H2BAF. But, it is necessary to make 2 hours longer at HNxBAF.

  • PDF

A Study on Double Sinusoidal Modulated PWM Inverter (2중 정현파 PWM 인버어터에 관한 연구 (上))

  • 차득근
    • Journal of the Korean Professional Engineers Association
    • /
    • v.22 no.4
    • /
    • pp.12-16
    • /
    • 1989
  • This paper presents a n analysis of the output voltage waveforms of the double sinusoidal modulated PWM inverter, and are studied on the driving characteristics through the 3 phase induction motor using 6502 microcomputer. The double sinusoidal modulated waves are produced during the interval 4$\pi$/3 [rad] for one cycle, and the switching loss can be reduced. The amplitude of fundamental wave of double sinusoidal modulated PWM inverter is 1.15 times higher than that of the sinusoidal PWM inverter, but the practical measured value by FFT analyzer is 1.13 times.

  • PDF

Incremental analysis of VHDL descriptions (VHDL 기술의 점진적 분석)

  • 안태균;김구학;박상훈;최기영
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.7
    • /
    • pp.1-7
    • /
    • 1997
  • VHDL simulation requires both analysis and elaboration processes. Reducing the time taken by these processes shorten design cycles. We propose an incremental analysis and elaboration algorithm for VHDL, which minimizes the number of design units to be re-analyzed and re-elaborated after an incremental change, thereby reducing the desing cycle time. Experimental results show about four times performance improvement in analysis and 1.25 times in elaboration over the conventional method.

  • PDF

VARIATION IN THE PERIOD OF THE SYSTEM GO CYG

  • ELKHATEEB M. M.
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.13-16
    • /
    • 2005
  • We present a period analysis of the well known $\beta$ Lyrae type eclipsing binary GO Cyg $(P= 0^d .7177)$. Several new times of minimum light, recorded photoelectrically, have been gathered. Analysis of all available eclipse timings of GO Cyg has confirmed a significant period increase with rate of $2.52 {\times} 10^{-10}$ day / cycle, also new period has been estimated. New linear and quadratic ephemerides have been calculated for the system.

A Feasibility of Once-Through Thorium Fuel Cycle for PWR (가압경수로에서 비순환 토륨 핵연료 주기의 적용 타당성)

  • 우일탁;김명현
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.131-136
    • /
    • 1999
  • 토륨은 자연계에서 유일한 동위원소인 Th-232로 존재하며 반감기는 1.4$\times$$10^{10}$년으로 U-238의 4.5$\times$$10^{9}$년에 비하여 약 3배 길고 매장량도 약 3배 많은 것으로 알려져 있다. 토륨은 원자력 초기 개발단계인 1950년대부터 우라늄에 관한 연구와 함께 시작되었지만, 70년대 중반 이후로는 토륨 핵연료 재처리의 어려움과 여러 정치적 이유로 이에 관한 연구가 거의 중단되었다.(중략)

  • PDF

A Study on the Atomic-Layer Deposition Mechanism and Characteristics of TiN Films Deposited by Cycle-CVD (Cycle-CVD법으로 증착된 TiN 박막의 ALD 증착기구와 특성에 관한 연구)

  • Min, Jae-Sik;Son, Young-Woong;Kang, Won-Gu;Kang, Sang-Won
    • Korean Journal of Materials Research
    • /
    • v.8 no.5
    • /
    • pp.377-382
    • /
    • 1998
  • Atomic layer deposition(ALD) of amorphous TiN films on $SiO_2$ between 17$0^{\circ}C$ and 21O$^{\circ}C$ has been investigated by alternate supply of reactant sources, Ti[N($C_2,H_5,CH_3)_2]_4$ [tetrakis(ethylmethylamminoltitanium: TEMAT] and $NH_3$. Reactant sources were injected into the reactor in the order of TEMAT vapor pulse, Ar gas pulse, $NH_3$. gas pulse and Ar gas pulse. Film thickness per cycle was saturated at around 1.6 monolayer(MU per cycle with sufficient pulse times of reactant sources at 20$0^{\circ}C$. The results suggest that film thickness per cycle could be beyond 1 MLicycie in ALD, which were explained by rechemisorption mechanisms of reactant sources. The ideal linear relationship be¬tween number of cycles and film thickness is confirmed. As a results of surface limited reactions of ALD, step cover¬age was excellent. Particles caused by the gas phase reactions between TEMAT and NH3 were almost free because TEMAT was seperated from $NH_3$ by the Ar pulse. In spite of relatively low substrate temperature, carbon impurity was incorporated below 4 at%.

  • PDF

Optimization of Heat Transfer Area Distribution for a Hot Water Driven Absorption Chiller (중온수 흡수식 냉동기의 열전달 면적 최적화)

  • 정시영;조광운;이상수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.431-438
    • /
    • 2000
  • The major irreversibilities in absorption chillers are associated with the transfer of heat into and out from the machine and irreversible process inside the machine. By modeling only external irreversibilities(endo-reversible), a model was formulated to predict the ideal performance of a single-effect absorption chiller. Its actual performance including both external and internal irreversibilities was calculated with a in-house simulation program. The optimization of heat transfer area distribution was performed for both endo-reversible cycle and actual cycle. The equation of endo-reversible modeling was found to give about 2times higher cooling capacity than the simulation program. At optimal distribution, it was found that heat transfer area of the evaporator was about 30% of total area, that of the generator was 20%, and the rest 50% was for the absorber and condenser. The system COP for endo-reversible cycle was slightly higher than that for actual cycle. In the case of LiBr-water single-effect absorption chiller, the maximum cooling capacity was obtained near the condition that LMTD is same at all heat exchangers.

  • PDF