• Title/Summary/Keyword: Cycle

검색결과 20,443건 처리시간 0.04초

월경과 수면 (Menstruation and Sleep)

  • 박두흠
    • 수면정신생리
    • /
    • 제9권2호
    • /
    • pp.81-85
    • /
    • 2002
  • There are several factors which are more likely to have sleep disorders in fertile women with menstruation than adult men. Menstrual cycle plays an important role in them. We describe herein the overview about the association of menstrual cycle and sleep disorders by viewing the interactions of menstrual cycle and circadian rhythm. We review how menstrual cycle affects sleep-wake cycle by reviewing menstrual cycle and estrous cycle to understand these interactions. Menstrual cycle and estrous cycle are mainly affected by hormonal cycle and light-dark cycle, respectively and they are generally determined in monthly rhythm and annual rhythm, respectively. The determination of estrous cycle is also affected by cyclic changes of hormones besides light-dark cycle. Although sleep-wake cycle almost alternates according to estrous cycle in non-primate mammals, it is hardly affected by menstrual cycle in primate mammals as compared with estrous cycle. But menstrual cycle affects sleep-wake cycle via desynchronization of sleep-wake cycle and temperature rhythm. The decrease of amplitude and phasic change during luteal phase in the daily fluctuation of body core temperature can partially contribute to the induction of sleep disorders in fertile women. In addition to this, premenstrual syndrome which nearly happens during luteal phase commonly have sleep problems. Therefore, we suggest that menstrual cycle and PMS can partially contribute the increase of sleep disorders in fertile women.

  • PDF

해양 온도차발전 시스템의 열역학 사이클에 대한 연구 (A Study on the Thermodynamic Cycle of OTEC system)

  • 김남진;신상호;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제26권2호
    • /
    • pp.9-18
    • /
    • 2006
  • In this paper, the thermodynamic performance of OTEC cycle was examined. Computer simulation programs were developed for simple Rankine cycle, regenerative Rankine cycle, Kalina cycle, open cycle and hybrid cycle. For the simple Rankine cycle, the results show that newly developed fluids such as R410A and R32 that do not cause stratospheric ozone layer depletion perform as well as R22 and ammonia. Also, simple Rankine cycle OTEC power plant can practically generate electricity when the difference in warm and cold sea water inlet temperatures are greater than $14^{\circ}C$. The regenerative Rankine cycle showed a 1.5 to 2% increase in energy efficiency compared to the simple Rankine cycle while the Kalina cycle employing ammonia/water mixture showed a 2-to-3% increase in energy efficiency, and the overall cycle efficiencies of hybrid cycle and open cycle were 3.35% and 4.86%, respectively.

혁신주기, 투자주기 그리고 경기변동에 관한 실증분석 (An Empirical Analysis on the Relationship among Innovation Cycle, Investment Cycle and Business Cycle in Frequency Domain)

  • 조상섭;이장우
    • 기술혁신학회지
    • /
    • 제5권2호
    • /
    • pp.129-140
    • /
    • 2002
  • This study is try to do the empirical tests on the relationship among innovation cycle, investment cycle, and business cycle suggested in recent economic growth models. We apply co-spectra analysis to estimate dynamic correlations in the extraction HP filtered variables and first difference filtered variables in our data set. Our empirical results are; (i) an existing asynchronization between innovation cycle and investment cycle, (ii) in the long frequency, an existing positive correlation between innovation cycle and business cycle, (iii) in the short frequency, however, a finding the high negative correlation between the two cycle. Our empirical findings support the recent growth through cycle models and suggest some economic policy implementations for economic stabilization during a severe business cycle.

  • PDF

2단압축 이산화탄소 사이클의 냉방성능 향상 특성에 대한 실험적 연구 (Experimental Study on the Cooling Performance Improvement of a Two-stage Compression $CO_2$ Cycle)

  • 조홍현;이호성;김용찬
    • 설비공학논문집
    • /
    • 제18권10호
    • /
    • pp.835-841
    • /
    • 2006
  • A $CO_2$ system using the two-stage compression cycle was tested by varying $1^{st}-2^{nd}$ compressor frequencies in the cooling mode. To improve the cooling performance of the two-stage compression $CO_2$ cycle, the following cycle options were applied: a basic cycle, a cycle with an intercooler, a cycle with an IHX (internal heat exchanger), and a cycle with an intercooler and IHX. The cycle with the intercooler-IHX showed the highest cooling capacity improvement among the cycle options at all compressor frequencies. The cycle with the intercooler, the cycle with the IHX, and the cycle with the intercooler-IHX improved the cooling COP by 7, 12, and 15%, respectively, over the basic $CO_2$ cycle when the compressor frequencies for the first and second compressors were 50 Hz and 30 Hz, respectively. In addition, the applications of the selected cycle options enhanced system reliability.

무선 센서 네트워크에서 Duty Cycle의 영향 (Impact of Duty Cycle in Wireless Sensor Networks)

  • 스타핏프라네쉬;변재영
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 추계종합학술대회 B
    • /
    • pp.854-857
    • /
    • 2008
  • 무선 센서 네트워크의 센서 노드는 내부 전원을 사용함으로 인해 수명이 제한적이다. 기존의 여러 MAC 프로토콜은 무선 센서 네트워크에서 에너지 절약을 위해 sleep/listen cycle을 스케쥴링한다. 또한, MAC프로토콜의 duty-cycle은 사용자의 조정에 의해 낮은 duty cycle로 변화할 수 있으며, 이는 프레임에서 sleep 시간을 결정하게 된다. 이러한 duty cycle의 크기는 MAC 프로토콜의 성능에 직접적인 영향을 미친다. 본 논문에서는 NS-2 환경에서 서로 다른 duty cycle을 갖는 TEEM과 SMAC을 시뮬레이션하고 두 개의 프로토콜의 에너지 소비와 성능 측면에서 duty cycle을 분석한다.

  • PDF

Design and Exergy Analysis for a Combined Cycle of Liquid/Solid $CO_2$ Production and Gas Turbine using LNG Cold/Hot Energy

  • Lee, Geun-Sik
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권1호
    • /
    • pp.34-45
    • /
    • 2007
  • In order to reduce the compression power and to use the overall energy contained in LNG effectively, a combined cycle is devised and simulated. The combined cycle is composed of two cycles; one is an open cycle of liquid/solid carbon dioxide production cycle utilizing LNG cold energy in $CO_2$ condenser and the other is a closed cycle gas turbine which supplies power to the $CO_2$ cycle, utilizes LNG cold energy for lowering the compressor inlet temperature, and uses the heating value of LNG at the burner. The power consumed for the $CO_2$ cycle is investigated in terms of a solid $CO_2$ production ratio. The present study shows that much reduction in both $CO_2$ compression power (only 35% of the power used in conventional dry ice production cycle) and $CO_2$ condenser pressure could be achieved by utilizing LNG cold energy and that high cycle efficiency (55.3% at maximum power condition) in the gas turbine could be accomplished with the adoption of compressor inlet cooling and regenerator. Exergy analysis shows that irreversibility in the combined cycle increases linearly as a solid $CO_2$ production ratio increases and most of the irreversibility occurs in the condenser and the heat exchanger for compressor inlet cooling. Hence, incoming LNG cold energy to the above components should be used more effectively.

단일유로 멀티사이클 및 바이패스유로 멀티사이클 적용 냉동시스템의 성능특성에 관한 실험적 연구 (An Experimental Study on the Performance Characteristics of a Single-Circuit Multi Cycle and a Bypass Two-Circuit Multi Cycle)

  • 송영승;정해원;윤원재;김용찬
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.513-519
    • /
    • 2011
  • The object of this study is to investigate the performance characteristics of refrigerators using a single-circuit multi cycle and a bypass two-circuit multi cycle. Each refrigeration cycle was tested by varying secondary fluid mass flow rate and temperature. Based on the experimental data, the optimum refrigerant charge was 48 g and the COP at the optimum secondary fluid mass flow rate was 1.53 for the single-circuit multi cycle. For freezer(F)-only mode, both the single-circuit multi cycle and the bypass two-circuit multi cycle were operated at overcharge conditions, resulting in an increase of the secondary fluid mass flow rate. The maximum COPs of the single-circuit multi cycle and the bypass two-circuit multi cycle were 1.22 and 1.35, respectively. The COP increased by 10.7% with the application of the bypass two-circuit multi cycle.

저온 해수를 이용한 난방 및 담수화사이클 성능 해석 (Analysis of Heating and Desalination Cycle Using Low Temperature Seawater)

  • 이호생;이승원;정동호;문덕수;김현주
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제14권4호
    • /
    • pp.301-306
    • /
    • 2011
  • 저온 해수에너지를 이용한 난방사이클 및 이와 연계할 수 있는 적정 담수화사이클에 대하여 제안 및 해석을 수행하였다. 난방사이클은 기본 증기압축식 사이클을 이용하여 1단 및 2단압축사이클에 대해 해석을 수행하였고, 담수화사이클은 난방사이클과 연계할 수 있도록 설계하여 해석을 수행하였다. 난방사이클의 증발기 열원으로 5이하의 저온 해수열을 이용하였고, 난방수 온도는 60 이상 공급될 수 있도록 해석하였으며, 사이클 작동유체는 R-134a, R-1234 yf, R-600a를 적용하였다. 사이클 해석 결과, 2단압축사이클을 적용할 경우 1단압축사이클에 비해 모든 냉매에서 압축기 소요동력은 약 15.6% 감소하였고, 성능계수는 약 17.6% 향상되었다. 냉동법 담수화 사이클의 경우 R-134a에 대해서 난방수 60 조건일 때, 1단압축 사이클에 비해 2단압축사이클을 적용할 경우 담수 1kg 생산당 에너지가 약 19.8% 감소하는 것으로 나타났다.

Overview of Separation Technologies in the AFCI

  • You, G.S.;Choung, W.M.;Ku, J.H.;Jo, I.J.;Kook, D.H.;Kwon, K.C.;Lee, E.P.;Lee, W.K.;Jeong, K.J.;Park, S.W.
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 추계학술발표회
    • /
    • pp.241-242
    • /
    • 2005
  • PDF

전기자극 시 활동주기 형태의 변화가 혈중젖산과 혈장효소에 미치는 영향 (The Effects of Changing Duty Cycle With Electrical Stimulation on Blood Lactate and Plasma Enzyme)

  • 고태성;정호발
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.90-97
    • /
    • 2005
  • By measuring changes in blood lactate and plasma enzyme (CPK, GOT, GPT) with electrical stimulation applied at two duty cycles, this study is intended to look into which type of duty cycle may have more effects on blood lactate and plasma enzyme constituents through animal experiment so as to determine any duty cycle appropriate for electrical treatment. In this study, electrical stimulation was applied to total 20 Korean house rabbits (weight: 3~3.5 kg) by means of an electrical therapeutic apparatus called TS6000 (made in Netherlands) at duty cycle of 50% and 20% respectively for 30 minutes. Here, 5 cc of blood was collected from their carotid artery before stimulation and in 30 minutes after stimulation respectively to carry out biochemical experiment and analysis. As determined through the above experiment, blood lactate rate was increased to 333.07% at 50% duty cycle after experiment and 185.71% at 20% duty cycle after experiment respectively. In both cases, blood lactate rate was significantly increased to higher level after electrical stimulation than before. Moreover, the rate of change in the average of blood lactate rate at both duty cycles also showed significant differences. CPK rate was boosted to 301.82% at 50% duty cycle after experiment and 321.35% at 20% duty cycle after experiment respectively. In both cases, CPK rate was remarkably boosted to higher level after stimulation than before (p<.05). However, there was not any significant difference in the rate of change in average CPK at both duty cycles (p<.05). GOT rate was significantly boosted up to 38.97% at 50% duty cycle after experiment (p<.05), while it was slightly increased to 1.68% at 20% duty cycle after experiment without any significant difference. Rather, GPT rate dropped slightly at both duty cycles after experiment, but there was not any significant difference. Although blood lactate and GOT were relatively less generated at 20% duty cycle after electrical stimulation than at 50% duty cycle, the change of duty cycle didn't have any significant influence on CPK rate. In this regard, this study failed to come any consistent conclusion about the association between change of duty cycle and muscle fatigue. Therefore, it is advisable that follow-up studies seek various ways to a little more effectively apply electrical stimulation to laboratory animals by avoiding their muscle fatigue. GOT rate was significantly boosted up to 38.97% at 50% duty cycle after experiment (p<.05), while it was slightly increased to 1.68% at 20% duty cycle after experiment without any significant difference. Rather, GPT rate dropped slightly at both duty cycles after experiment, but there was not any significant difference. Although blood lactate and GOT were relatively less generated at 20% duty cycle after electrical stimulation than at 50% duty cycle, the change of duty cycle didn't have any significant influence on CPK rate. In this regard, this study failed to come any consistent conclusion about the association between change of duty cycle and muscle fatigue. Therefore, it is advisable that follow-up studies seek various ways to a little more effectively apply electrical stimulation to laboratory animals by avoiding their muscle fatigue.

  • PDF