• 제목/요약/키워드: Cutoff values

검색결과 179건 처리시간 0.027초

GaAs/InGaP HBT 소신호 등가회로 모델 파라미터의 새로운 추출방법 (A New Extraction Method of GaAs/InGaP HBT Small-signal Equivalent Circuit Model Parameters)

  • 이명규;윤경식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(1)
    • /
    • pp.357-360
    • /
    • 2000
  • This paper describes a parameter extraction method for HBT(Heterojunction Bipolar Transistor) equivalent circuit model without measurements of special test structures or numerical optimizations. Instead, all equivalent circuit parameters are calculated analytically from small-signal S-parameters measured under different bias conditions. These values being extracted from the cutoff mode can be used to extract intrinsic parameters at the active mode. This method yields a deviation of about 1.3 % between the measured and modeled S-parameters.

  • PDF

대용품질특성치를 이용한 계수선별형 샘플링 검사방식의 경제적 설계 (An Economic Design of Rectifying Inspection Plans Based on a Correlated Variable)

  • 배도선;이경택;최인수
    • 대한산업공학회지
    • /
    • 제23권4호
    • /
    • pp.793-802
    • /
    • 1997
  • A sampling plan is presented for situations where sampling inspection is based on the quality characteristic of interest and items in rejected lots are screened based on a correlated variable. A cost model is constructed which involves the costs of misclassification errors, sampling and screening inspections. A method of finding optimal values of sample size, acceptance number and cutoff value on the correlated variable is presented, and numerical studies are given.

  • PDF

Are There Standardized Cutoff Values for Neutrophil-Lymphocyte Ratios in Bacteremia or Sepsis?

  • Gurol, Gonul;Ciftci, Ihsan Hakki;Terzi, Huseyin Agah;Atasoy, Ali Riza;Ozbek, Ahmet;Koroglu, Mehmet
    • Journal of Microbiology and Biotechnology
    • /
    • 제25권4호
    • /
    • pp.521-525
    • /
    • 2015
  • Bacteremia and sepsis are common causes of morbidity and mortality worldwide, with incorrect or delayed diagnoses being associated with increased mortality. New tests or markers that allow a more rapid and less costly detection of bacteremia and sepsis have been investigated. The aim of this study was to clarify the cutoff value of the neutrophillymphocyte ratio (NLR) according to procalcitonin (PCT) level in the decision-making processes for bacteremia and sepsis. In addition, other white blood cell subgroup parameters, which are assessed in all hospitals, for bacteremia and sepsis were explored. This retrospective study included 1,468 patients with suspected bacteremia and sepsis. Patients were grouped according to the following PCT criteria: levels <0.05 ng/ml (healthy group), 0.05-0.5 ng/ml (local infection group), 0.5-2 ng/ml (systemic infection group), 2-10 ng/ml (sepsis group), and >10 ng/ml (sepsis shock group). One important finding of this study, which will serve as a baseline to measure future progress, is the presence of many gaps in the information on pathogens that constitute a major health risk. In addition, clinical decisions are generally not coordinated, compromising the ability to assess and monitor a situation. This report represents the first study to determine the limits of the use of NLR in the diagnosis of infection or sepsis using a cutoff value of <5 when sufficient exclusion criteria are used.

Design of a 94-GHz Single Balanced Mixer Using Planar Schottky Diodes with a Nano-Dot Structure on a GaAs Substrate

  • Uhm, Won-Young;Ryu, Keun-Kwan;Kim, Sung-Chan
    • Journal of information and communication convergence engineering
    • /
    • 제14권1호
    • /
    • pp.35-39
    • /
    • 2016
  • In this paper, we develop a 94-GHz single balanced mixer with low conversion loss using planar Schottky diodes on a GaAs substrate. The GaAs Schottky diode has a nanoscale anode with a T-shaped disk that can yield high cutoff frequency characteristics. The fabricated Schottky diode with an anode diameter of 500 nm has a series resistance of 21 Ω, an ideality factor of 1.32, a junction capacitance of 8.03 fF, and a cutoff frequency of 944 GHz. Based on this technology, a 94-GHz single balanced mixer was constructed. The fabricated mixer shows an average conversion loss of -7.58 dB at an RF frequency of 92.5 GHz to 95 GHz and an IF frequency of 500 MHz with an LO power of 7 dBm. The RF-to-LO isolation characteristics were greater than -32 dB. These values are considered to be attributed to superior Schottky diode characteristics.

우리나라 젊은 성인 여성의 철분영양상태와 이에 영향을 미치는 식이요인 분석(1) : 혈액의 철분 영양 상태 평가 지표의 비교 및 분석 (Iron Nutriture and Related Dietary Factors in Apparently Healthy Young Korean Women(1) : Comparison and Evaluation of Blood Bichemical Indices for Assessment of Iron Nutritional Status)

  • 계승희
    • Journal of Nutrition and Health
    • /
    • 제26권6호
    • /
    • pp.692-702
    • /
    • 1993
  • To evaluate iron nutritional status and to compare biochemical indices used for evaluation of iron nutriture, fasting blood sample was taken from 96 Korean female college student and hemoglobin(Hb) concentration, hematocrit(Hct), serum iron, total iron binding capacity(TIBC) and serum ferritin concentration were measured and transferrin(TF) saturation was calculated. Prevalence of iron deficiency varied from 4.2% when judged from Hb concentration and Hct to 38.5% and 40.6% when TIBC and serum ferritin concentration were used. TIBC was negatively correlated with serum ferritin(r=0.4561, p<0.001), while other indices showed positive but less significant correlations(p<0.05). Regarding iron status judged by serum ferritin was regarded as true iron status, the present cutoff points of Hb, Hct, serum iron, TF saturation were very insensitive in identifying the subjects with iron deficiency. Only TIBC was suitable for detecting iron deficiency in the study subjects. It is concluded from the study results that iron deficiency in young Korean adult women would be significantly underestimated with presently used biochemical measurements except TIBC and new cutoff points of these indices were proposed based on sensitivity, specificity measured prevalence, and positive and negative predictive values.

  • PDF

최적화된 고주파 강조 필터를 이용한 의료영상의 개선 (An Enhancement of Medical Image Using Optimized High-Frequency Emphasis Filter)

  • 신충호;정채영
    • 한국정보통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.698-704
    • /
    • 2013
  • 영상개선을 위한 영상처리는 응용분야에 따라서 동일한 알고리즘이 각각 다르게 적용되므로 응용분야에 적합한 최적값이 필요하다. 본 논문에서는 X선 의료영상분야에 고주파통과 필터를 적용해서 에지영역을 개선하였고, 결과영상에 상수승수와 오프셋을 더하여 에지영역 및 평탄영역의 컨트라스트를 향상시켰다. 그러므로, 의료영상을 최적화시키기 위해서는 고주파강조필터가 필요함을 알 수 있었다. 또한, 구체적인 최적화 변수값으로는 가우시안 고주파통과필터, 차단주파수의 거리=0.05, 오프셋=0.5 값이다. 마지막으로 이들 최적화 변수값을 적용시켜 시뮬레이션 한 결과, 제안된 방법이 기존 방법들에 비해서 영상의 컨트라스트와 에지부분들을 향상시켰다.

Psychometric Properties of Korean Version of Modified Leeds Sleep Evaluation Questionnaire (KMLSEQ)

  • Kim, Inja;Choi, Heejung;Kim, Beomjong
    • 재활간호학회지
    • /
    • 제17권1호
    • /
    • pp.10-17
    • /
    • 2014
  • Purpose: The Leeds Sleep Evaluation Questionnaire (LSEQ) translated into Korean was modified to easily apply and reduce respondents' confusion and was evaluated for psychometric properties and discriminant ability. Methods: A total of 960 Korean adults aged 45 years and older participated in this cross-sectional survey. To test reliability, validity and discriminant ability, Cronbach's alpha, correlation analysis, confirmatory factor analysis, simple regression analysis and receiver operating characteristics (ROC) curve analysis were used. Results: Item-total correlations ranged between 62~.85 and Cronbach's alpha was .95. Area under ROC was .86 (95% CI: .83~.90) and the optimal cutoff score was identified as ${\leq}$ 66 (sensitivity, .77; specificity, .84; positive/negative predictive values, .49/.95). Using this cutoff score, the prevalence of insomnia in the study sample was 25.8% and tended to be more common in female and older groups. Conclusion: The data supported the psychometric properties of Korean Modified Leeds Sleep Evaluation Questionnaire (KMLSEQ) as an acceptable sleep measurement. In addition, KMLSEQ is likely to be a useful screening tool for insomnia.

대기 에어로졸 측정용 3단 임팩터의 설계 및 성능평가 (Design and Performance Evaluation of a Three Stage Impactor)

  • 지준호;배귀남;황정호
    • 한국대기환경학회지
    • /
    • 제17권6호
    • /
    • pp.441-450
    • /
    • 2001
  • A three stage impactor with the cutoff diameters of 1, 2.5, and 10$\mu\textrm{m}$ in aerodynamic diameter was developed and tested. The gravimetric method and the particle counting method were utilized to evaluate the collection performance of each stage. A vibrating orifice aerosol generator was employed to generate monodisperse test aerosols larger that 2$\mu\textrm{m}$ in diameter. Polystyrene latex (PSL) particles smaller than 2$\mu\textrm{m}$ in diameter were generated by an atomizer and the particle number concentration was measured by an Aerodynamic Particle Sizer Spectrometer. The experimental cutoff diameters obtained from the particle collection efficiency curves are in good agreement with the designed values. The square roots of Stokes number at 50% collection efficiency for stage 1, 2, and 3 are 0.42, 0.48, and 0.45, respectively. Effects of the particle bounce and the impaction plate on the collection efficiency were investigated. The collection efficiency curves including effect of the particle bounce were also compared with those of the MOUDI cascade impactor.

  • PDF

Can Observational Gait Assessment Tools be used to Assess Independent Walking in Stroke Patients?

  • Ju, Sung-Kwang
    • 대한물리의학회지
    • /
    • 제17권1호
    • /
    • pp.11-20
    • /
    • 2022
  • PURPOSE: A gait assessment is an important component of the rehabilitation process, and observational gait assessment (OGA) is used routinely in clinical settings. This study examined the association of OGA tools with the independent walking ability in stroke patients to determine a cutoff value of the OGA tool according to independence levels of stroke patient gait. METHODS: Two hundred ten hemiparetic stroke patients participated in the study. The independence of gait was identified using the Functional Ambulation Category (FAC) classifications. The walking ability was assessed using OGA tools (Rivermead Visual Gait Assessment [RVGA], Wisconsin Gait Scale [WGS], Tinetti Gait Scale [TGS], and Functional Gait Analysis [FGA]). RESULTS: Stepwise multiple regression analysis showed that among the OGA tools, the FGA correlated with the FAC. The FGA explained approximately 77% of the variance in FAC. In distinguishing the independence levels, the cutoff values were as follows: between FAC 1 and FAC 0 was .5 points; between FAC 2 and lower levels, 5.5; between FAC 3 and lower levels, 11.5; between FAC 4 and lower levels, 14.5; and between FAC 5 and lower levels, 18.5. Items 1, 2, 3, and 10 were identified as explaining most of the variance in the FGA in the stepwise multiple regression. CONCLUSION: The present study found that the FGA is an assessment tool related to the level of gait independence after stroke. Furthermore, the FGA total score can serve as an index of the increase in independence level after stroke.

Accuracy of maximal expiratory flow-volume curve curvilinearity and fractional exhaled nitric oxide for detection of children with atopic asthma

  • Park, Sang Hoo;Im, Min Ji;Eom, Sang-Yong;Hahn, Youn-Soo
    • Clinical and Experimental Pediatrics
    • /
    • 제60권9호
    • /
    • pp.290-295
    • /
    • 2017
  • Purpose: Airway pathology in children with atopic asthma can be reflected by the concave shape of the maximal expiratory flow-volume (MEFV) curve and high fractional exhaled nitric oxide (FeNO) values. We evaluated the capacity of the curvilinearity of the MEFV curve, FeNO, and their combination to distinguish subjects with atopic asthma from healthy individuals. Methods: FeNO and angle ${\beta}$, which characterizes the general configuration of the MEFV curve, were determined in 119 steroid-naïve individuals with atopic asthma aged 8 to 16 years, and in 92 age-matched healthy controls. Receiver operating characteristic (ROC) curve analyses were performed to determine the cutoff points of FeNO and angle ${\beta}$ that provided the best combination of sensitivity and specificity for asthma detection. Results: Asthmatic patients had a significantly smaller angle ${\beta}$ and higher FeNO compared with healthy controls (both, P<0.001). For asthma detection, the best cutoff values of angle ${\beta}$ and FeNO were observed at $189.3^{\circ}$ and 22 parts per billion, respectively. The area under the ROC curve for the combination of angle ${\beta}$ and FeNO improved to 0.91 (95% confidence interval [CI], 0.87-0.95) from 0.80 (95% CI, 0.75-0.86; P<0.001) for angle ${\beta}$ alone and 0.86 (95% CI, 0.82-0.91; P=0.002) for FeNO alone. In addition, the combination enhanced sensitivity with no significant decrease in specificity. Conclusion: These data suggest that the combined use of the curvilinearity of the MEFV curve and FeNO is a useful tool to differentiate between children with and without atopic asthma.