• Title/Summary/Keyword: Cut-point Diameter

Search Result 25, Processing Time 0.022 seconds

Studies on the Phrenic Nerve Fibers in the dog II. On the Myelinated Fibers of the Intradiaphragmatic Branches (개의 횡격막신경섬유(橫隔膜神經纖維)에 관(關)한 연구(硏究) 제(第)II보(報) 횡격막신경(橫隔膜神經)의 횡격막내분기(橫隔膜內分技)의 유수섬유(有髓纖維)에 관(關)하여)

  • Ko, Kwang Doo;Yoon, Suk Bong;Lee, Joon Sup
    • Korean Journal of Veterinary Research
    • /
    • v.9 no.1
    • /
    • pp.1-9
    • /
    • 1969
  • The experimental studies were performed to observe the characteristics of the myelinated nerve fibers of the tradiaphragmatic branches of phrenic nerves in dog In the work to be reported five mixed breed Korean dog were used, they were one year old and he body eights were about 12 Kgm. in average with healthy conditions. The specimens (nerve) were taken at the point of 1.5 cm posterior part from the left and right phrenic nerves entrance to the diaphragm, and the dorso-lateral and dorso-medial branches of phrenic nerves vere also, taken at the point of 0.5 cm distal part from their branching portion. The specimens were fixed for 24 hrs. in Flemming's solution, and embedded in paraffin. The paraffin section. were cut at 6 microns and stained with Walter's modification of Weigert-pal method for the myelinated fibers. Microphotographs were taken and enlarged into 750 times of the actual size, and the diameter of the photographic images of the myelinated fibers were measured by the scale on the transparent Percepex Plate. The following conclusions were made: 1. The percentage of distribution of the several intradiaphragmatic branches of phrenic nerves were as follows. Ventral branches were 34.97%, lateral branches were 37.90%, dorsal branches were 27.13%, and the dorsal branches were branched again into dorso-lateral branches(54.22%) and dorso-medial branches (45. 78%). 2. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left ventral branches were $490.80{\pm}12$, and at the right ventral branches were $486.6{\pm}13$. Total average cross sectional area on the left ventral branches were 38,000. $6{\pm}136{\mu}^2$, and the right ventral branches were $37,150.2{\pm}1.782{\mu}^2$. 3. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left lateral branches were $533.8{\pm}8$, and at the right lateral branches were $525.6{\pm}7$. Total average cross sectional area of the left lateral branches were $41,582{\pm}1,170{\mu}^2$, and the right lateral branches were $40,454.8{\pm}812{\mu}^2$. 4. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left dorsal branches were $378.2{\pm}14$, and at the right dorsal branches were $380.2{\pm}8$. Total average cross sectional area of the left dorsal branches were $27,771{\pm}1,256{\mu}^2$, and the right dorsal branches were $27,507.2{\pm}645{\mu}^2$. 5. The mean value and S.D. of the total numbers of the myelinated fibers at the left dorso-lateral branches were $205.4{\pm}15$, and at the right dorso-lateral branches were $210.6{\pm}17$. Total average cross sectional area of the left dorso lateral branches were $15,354. 8{\pm}1,519{\mu}^2$, and the right dorsal branches were $15,887{\pm}1,297{\mu}^2$. 6. The mean value and S.D. of the total numbers of the myelinated nerve fibers at the left dorso-medial branches were $175{\pm}14$, and at the right dorso-medial branches were $176.2{\pm}17$. Total average cross sectional area of the left dorso-medial branches were $13,037.4{\pm}944{\mu}^2$, and at the right dorso-medial branches were, $13,103{\pm}1,373{\mu}^2$. 7. The highest frequent distribution of the intradiaphragmatic branches of phrenic nerves were found in the $10-12{\mu}^2$ groups, and they were almost 30% of the total groups. 8. The largest fibers diameter were in the $14-16{\mu}^2$ groups, and these were shown the lowest frequent distribution. 9. The largest cross sectional area of the intradiaphragmatic branches of phrenic nerves were found in the $10-12{\mu}^2$ groups. 10. All of the intradiaphragmatic branches of phrenic nerves were unimodal which has a peak in the $10-12{\mu}^2$ groups.

  • PDF

An Analytical Study on Stem Growth of Chamaecyparis obtusa (편백(扁栢)의 수간성장(樹幹成長)에 관(關)한 해석적(解析的) 연구(硏究))

  • An, Jong Man;Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.4
    • /
    • pp.429-444
    • /
    • 1988
  • Considering the recent trent toward the development of multiple-use of forest trees, investigations for comprehensive information on these young stands of Hinoki cypress are necessary for rational forest management. From this point of view, 83 sample trees were selected and cut down from 23-ear old stands of Hinoki cypress at Changsung-gun, Chonnam-do. Various stem growth factors of felled trees were measured and canonical correlaton analysis, principal component analysis and factor analysis were applied to investigate the stem growth characteristics, relationships among stem growth factors, and to get potential information and comprehensive information. The results are as follows ; Canonical correlation coefficient between stem volume and quality growth factor was 0.9877. Coefficient of canonical variates showed that DBH among diameter growth factors and height among height growth factors had important effects on stem volume. From the analysis of relationship between stem-volume and canonical variates, which were linearly combined DBH with height as one set, DBH had greater influence on volume growth than height. The 1st-2nd principal components here adopted to fit the effective value of 85% from the pincipal component analysis for 12 stem growth factors. The result showed that the 1st-2nd principal component had cumulative contribution rate of 88.10%. The 1st and the 2nd principal components were interpreted as "size factor" and "shape factor", respectively. From summed proportion of the efficient principal component fur each variate, information of variates except crown diameter, clear length and form height explained more than 87%. Two common factors were set by the eigen value obtained from SMC (squared multiple correlation) of diagonal elements of canonical matrix. There were 2 latent factors, $f_1$ and $f_2$. The former way interpreted as nature of diameter growth system. In inherent phenomenon of 12 growth factor, communalities except clear length and crown diameter had great explanatory poorer of 78.62-98.30%. Eighty three sample trees could he classified into 5 stem types as follows ; medium type within a radius of ${\pm}1$ standard deviation of factor scores, uniformity type in diameter and height growth in the 1st quadrant, slim type in the 2nd quadrant, dwarfish type in the 3rd quadrant, and fall-holed type in the 4 th quadrant.

  • PDF

A Study on Performance Improvement of Fruit Vegetables Automatic Grafting System (과채류 접목시스템 개선 연구)

  • Kang, Dong Hyeon;Lee, Si Young;Kim, Jong Koo;Park, Min Jung;Son, Jin Kwan;Yun, Sung-Wook;An, Se Woong;Jung, In Kyu
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.215-220
    • /
    • 2017
  • This study was conducted to improve the insufficiency of fruit vegetable grafting system developed by National Institute of Agricultural Sciences, Rural Development Administration. When the rotary blade cut the stem of scions and rootstocks, the grafting failure at curved cutting surfaces happened. The cutting depth of a tomato seedling by a rotated cutter was calculated 0.11 mm even when the cutting arm length and the maximum stem diameter were 50 mm and 5 mm, respectively. Mathematical analysis and high-speed photography showed that there was no problem by cutting in straight the stem of scions and rootstocks. The compression test of seedling stems to design the optimal shape of gripper showed that stems were not completely restored when they were compressed above 0.8 mm and 0.6 mm in case of rootstocks and scion, respectively. This study found that the bending angle of stem of tomato seedlings at the grafting period was 10 degree on average. The optimal gripper finger was the edge finger type which could be precisely set center point by adjusting the distance between fingers. In addition, it was found that most of seedling could be grasped without damage when the finger-to-finger distances is set to 2.5 mm for scion and 3.0 mm for rootstocks and finger are coated by 1 mm-thick flexible material.

A STUDY ON THE CORROSION BEHAVIOUR OF AMALGAMS BY USING OF POTENTIOSTATIC POLARIZATION METHOD (정전압 분극곡선법에 의한 아말감의 부식 거동에 관한 연구)

  • Shin, Dong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.39-49
    • /
    • 1986
  • The purpose of this study was to observe characteristic properties through the polarization curves and SEM images from 4 different types of amalgam obtained by using the potentiostats (Princeton EG & G) & SEM (Jeol/35), and to investigate the degree of corrosion on the oxidation peak of the each phase of amalgam. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by means of the mechanical amalgamator (Shofu Co.), the triturated mass was inserted into the cylindrical metal mold which was 12mm in diameter and 10.0mm in height and was condensed by using routine manner. The specimen was removed from the mold and stored at room temperature for about 24 hours. The standard surface preparation was routinely carried out. Anodic polarization measurement was employed to confirm the corrosion behaviour of the amalgams in a 0.9% saline solution (P.H: 6.8-7.0) at $37^{\circ}C$. The initial rest potential (corrosion potential) was determined after 30 minutes of immersion of specimen in electrolyte, and the potential scan was begun at the point of 100mV cathodic from the corrosion potential. The scan rate was 0.17mV/sec. in the study to observe the degree of corrosion of each phase. SEI and EPMA images on the determined oxidation peaks of each amalgam were observed. The results were as follows: 1. In the four anodic polarization curves, low copper amalgams have three oxidation peaks and high copper amalgams have two oxidation peaks, -270mV, +26mV and +179mV(SEC) in the low copper lathe cut, and -300mV, +39mV and +163mV(SEC) in the low copper spherical. -4mV and +154mV(SEC) in the Dispersalloy, and +17mV and +180mV(SEC) in the Tytin as high copper amalgams. 2. ${\gamma}_2$ phase in the low copper amalgam and ${\eta}$ phase in the high copper amalgam were the most corrodible phases and Ag-Cu eutectic in high copper amalgam was the most slowly corroded phase. 3. Low copper amalgam was more susceptible in corrosion than high copper amalgam.

  • PDF

Analysis of thermal changes in bone by various insertion torques with different implant designs (서로 다른 형태의 임플란트의 식립토크가 골에 미치는 열변화에 관한 연구)

  • Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.2
    • /
    • pp.168-176
    • /
    • 2011
  • Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.