• Title/Summary/Keyword: Cut off angle

Search Result 85, Processing Time 0.031 seconds

An Experimental Study on the Shear Behavior of Reinforced Concrete Beams Strengthened with Slit Type Steel Plates (Slit형(形) 강판으로 보강(補强)한 철근콘크리트 보의 전단거동에 관한 실험연구)

  • Lee, Choon-Ho;Shim, Jong-Seok;Kwon, Ki-Hyuk
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2008
  • RC beam of existing structures often encounter shear problems for various reasons. The shear failure of RC beam is sudden and brittle. Strengthening technique jacketing with external bonding of steel plates(or CFRP and CFS) with epoxy is many use to in practice. This study presents test results on strengthening shear deficient RC beams by external bonding of slit type steel plates. Test parameters are width, interval, length, thickness and angle of slit in steel plates. The purpose was to evaluate the reinforcing effects, failure modes and shear capacities for RC beams of strengthened with various slit type steel plates. The test result confirmed that all slit steel plates improved the stiffness and strength of the specimens significantly. Failure modes of SV series and SD series showed shear fractures and flexure fractures at ultimate state respectively. SD series were ductile rather than SV series.

Ginsenoside Rh2 differentially Mediates microRNA Expression to Prevent Chemoresistance of Breast Cancer

  • Wen, Xu;Zhang, He-Da;Zhao, Li;Yao, Yu-Feng;Zhao, Jian-Hua;Tang, Jin-Hai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1105-1109
    • /
    • 2015
  • Chemoresistance is the most common cause of chemotherapy failure during breast cancer (BCA) treatment. It is generally known that the mechanisms of chemoresistance in tumors involve multiple genes and multiple signaling pathways,; if appropriate drugs are used to regulate the mechanisms at the gene level, it should be possible to effectively reverse chemoresistance in BCA cells. It has been confirmed that chemoresistance in BCA cells could be reversed by ginsenoside Rh2 (G-Rh2). Preliminary studies of our group identified some drugresistance specific miRNA. Accordingly, we proposed that G-Rh2 could mediate drug-resistance specific miRNA and corresponding target genes through the gene regulatory network; this could cut off the drug-resistance process in tumors and enhance treatment effects. G-Rh2 and breast cancer cells were used in our study. Through pharmaceutical interventions, we could explore how G-Rh2 could inhibit chemotherapy resistance in BCA, and analyze its impact on related miRNA and target genes. Finally, we will reveal the anti-resistance molecular mechanisms of G-Rh2 from a different angle in miRNA-mediated chemoresistance signals among cells.

Evaluation of Consistency on Kinematic Factors in Women Javelin Throw (여자 창던지기 운동학적 요인의 일관성 평가)

  • Hong, Soon-Mo;Lee, Young-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.65-71
    • /
    • 2007
  • The purpose of this study was to investigate variability of kinematic factors affecting the record in women's javelin throwing. For this study, 8 female-javelin thrower participated in this experiment. The three digital video cameras (Sony, 120x) were used to record motions. Kwon3D 2.1 was used to process data and they were analyzed with Excell for factors. The sampling rate of a camera was 60Hz and shutter speed of a camera was 1/1000sec. The coordinate data were filtered using a fourth-order Butterworth low pass filtering with an estimated optimum cut-off frequency of 6Hz. The results were as follows: 1. From cross step to landing of delivery, the average velocities of CoM of non-dominant athletes were greater than dominant athletes and those of CoM of non-dominant athletes less than dominant athletes, but at release dominant athletes had a lower average velocity and a variability than non-dominant athletes. 2. From cross step to landing of delivery, the average throwing velocities and variabilities of a javelin of dominant athletes were greater than dominant athletes, but at release, dominant athletes had a higher velocity than dominant athletes and had a equal variability. 3. At every events, a forward or backward angles and variabilities of non-dominant athletes were greater than dominant athletes. 4. From cross step to landing of delivery, dominant athletes' elbow average angles were greater than non-dominant athletes and the variabilities of latter less than non-dominant athletes, but at release dominant athletes' variabilities were smaller than non-dominant athletes. 5. At landing of delivery, dominant athletes' knee average angles and variabilities of a supporting foot were a greater than non-dominant athletes, and at release, dominant athletes' knee average angles was a greater but variabilities less than non-dominant athletes. In conclusion, the dominant threw javelins fast while having stable postures and the range of elbow's angle large.

Ground Contact Analysis for Korea's Fictitious Lunar Orbiter Mission

  • Song, Young-Joo;Ahn, Sang-Il;Choi, Su-Jin;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.255-267
    • /
    • 2013
  • In this research, the ground contact opportunity for the fictitious low lunar orbiter is analyzed to prepare for a future Korean lunar orbiter mission. The ground contact opportunity is basically derived from geometrical relations between the typical ground stations at the Earth, the relative positions of the Earth and Moon, and finally, the lunar orbiter itself. Both the cut-off angle and the orbiter's Line of Sight (LOS) conditions (weather orbiter is located at near or far side of the Moon seen from the Earth) are considered to determine the ground contact opportunities. Four KOMPSAT Ground Stations (KGSs) are assumed to be Korea's future Near Earth Networks (NENs) to support lunar missions, and world-wide separated Deep Space Networks (DSNs) are also included during the contact availability analysis. As a result, it is concluded that about 138 times of contact will be made between the orbiter and the Daejeon station during 27.3 days of prediction time span. If these contact times are converted into contact duration, the duration is found to be about 8.55 days, about 31.31% of 27.3 days. It is discovered that selected four KGSs cannot provide continuous tracking of the lunar orbiter, meaning that international collaboration is necessary to track Korea's future lunar orbiter effectively. Possible combinations of world-wide separated DSNs are also suggested to compensate for the lack of contact availability with only four KGSs, as with primary and backup station concepts. The provided algorithm can be easily modified to support any type of orbit around the Moon, and therefore, the presented results could aid further progress in the design field of Korea's lunar orbiter missions.

Strength of Improved Soil on the Work-conditions of Deep Mixing Method (시공조건에 따른 심층혼합처리 개량체의 강도에 관한 연구)

  • Lee, Kwang-Yeol;Yoon, Sung-Tai;Kim, Sung-Moo;Han, Woo-Sun
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.7
    • /
    • pp.99-104
    • /
    • 2007
  • The deep soil mixing, on ground modification technique, has been used for many diverse applications including building and bridge foundations, port and harbor foundations, retaining structures, liquefaction mitigation, temporary support of excavation and water control. This method has the basic objective of finding the most efficient and economical method for mixing cement with soil to secure settlements through improvement of stability on soft ground. In this research, the experiments were conducted on a laboratory scale with the various test conditions of mixing method; the angle of mixing wing, mixing speed. Strength and shapes of improved soil of these test conditions of deep mixing method were analysed. From the study, it was found that the mixing conditions affect remarkably to the strength and shapes of improved soils.

Study on GNSS Constellation Combination to Improve the Current and Future Multi-GNSS Navigation Performance

  • Seok, Hyojeong;Yoon, Donghwan;Lim, Cheol Soon;Park, Byungwoon;Seo, Seung-Woo;Park, Jun-Pyo
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.2
    • /
    • pp.43-55
    • /
    • 2015
  • In the case of satellite navigation positioning, the shielding of satellite signals is determined by the environment of the region at which a user is located, and the navigation performance is determined accordingly. The accuracy of user position determination varies depending on the dilution of precision (DOP) which is a measuring index for the geometric characteristics of visible satellites; and if the minimum visible satellites are not secured, position determination is impossible. Currently, the GLObal NAvigation Satellite system (GLONASS) of Russia is used to supplement the navigation performance of the Global Positioning System (GPS) in regions where GPS cannot be used. In addition, the European Satellite Navigation System (Galileo) of the European Union, the Chinese Satellite Navigation System (BeiDou) of China, the Quasi-Zenith Satellite System (QZSS) of Japan, and the Indian Regional Navigation Satellite System (IRNSS) of India are aimed to achieve the full operational capability (FOC) operation of the navigation system. Thus, the number of satellites available for navigation would rapidly increase, particularly in the Asian region; and when integrated navigation is performed, the improvement of navigation performance is expected to be much larger than that in other regions. To secure a stable and prompt position solution, GPS-GLONASS integrated navigation is generally performed at present. However, as available satellite navigation systems have been diversified, finding the minimum satellite constellation combination to obtain the best navigation performance has recently become an issue. For this purpose, it is necessary to examine and predict the navigation performance that could be obtained by the addition of the third satellite navigation system in addition to GPS-GLONASS. In this study, the current status of the integrated navigation performance for various satellite constellation combinations was analyzed based on 2014, and the navigation performance in 2020 was predicted based on the FOC plan of the satellite navigation system for each country. For this prediction, the orbital elements and nominal almanac data of satellite navigation systems that can be observed in the Korean Peninsula were organized, and the minimum elevation angle expecting signal shielding was established based on Matlab and the performance was predicted in terms of DOP. In the case of integrated navigation, a time offset determination algorithm needs to be considered in order to estimate the clock error between navigation systems, and it was analyzed using two kinds of methods: a satellite navigation message based estimation method and a receiver based method where a user directly performs estimation. This simulation is expected to be used as an index for the establishment of the minimum satellite constellation for obtaining the best navigation performance.

The Effect of Hounsfield Unit Value with Conventional Computed Tomography and Intraoperative Distraction on Postoperative Intervertebral Height Reduction in Patients Following Stand-Alone Anterior Cervical Discectomy and Fusion

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung;Woo, Joon Bum;Kim, Young Ha
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.1
    • /
    • pp.96-106
    • /
    • 2022
  • Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF. Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24-70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography. Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence. Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

Evaluation of Various Cardiae Indices and ROC Analysis in Coronary Artery Disease Employing Resting ECG Gated Blood Pool Scan (관상동맥질환에서 휴식기 심전도게이트혈액풀스캔을 이용한 각종 심기능 지표들의 평가 및 ROC 분석)

  • Choi, Chang-Woon;Lee, Dong-Soo;Kim, Sang-Eun;Chung, June-Key;Lee, Myung-Chul;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.40-48
    • /
    • 1992
  • Gated blood pool scan is frequently used for evaluating the change in cardiac function in various cardiac diseases. But resting gated blood pool scan using only LVEF as a cardiac index has been consitently shown to have a low sensitivity, which is about 50%, in detecting coronary artery disease. So it is recommended to compare exercise gated blood pool scan to resting gated blood pool scan. Exercise tests, however, are not always possible, especially in patients with musculoskeletal diseases, recent myocardial infarction and in elderly persons. We studied the usefulness of resting gated blood pool scan using multiple indices in evaluating the patients with coronary artery disease. Studied cases were 185 patients with coronary artery disease (angina pectoris 31, myocardial infarction 154) and 25 normals with low likelihood of coronary artery disease. We used $^{99m}Tc-labeled$ RBC, 740 MBq labeled by in vivo method. The data were evaluated by Micro DELTA computer program. The results were as following: 1) The ejection rates (PER, AER) and filling rates (PFR, AFR) were different in normls and patients with angina pectoris or myocardial infarction. 2) Mean phase angle, ejection rates and filling rates could separate normals from coronary artery disease patients with normal LVEF. 3) Regional ejection fraction was decreased at the site of the infarct in patients with myocardial infarction. 4) Peak filling rate was the the most detectable index in evaluation of cardiac function in patients with coronary artery disease. 5) The threshold at 1.5 standard deviation of normal range was considered as the most reliable cut-off value from ROC analysis. These data suggest that the resting gated blood pool scan has an important role in the evaluation of cardiac functional changes using various cardiac indices in patients with coronary artery disease.

  • PDF

A Study on SCOTT Transformer Protection Relay Malfunction Case and Improvement Methodology (스코트 변압기 보호계전기 오동작 사례분석 및 개선방안 고찰)

  • Lee, Jong-Hwa;Lho, Young-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.7
    • /
    • pp.394-399
    • /
    • 2017
  • In Korean AC power railway substations, SCOTT winding transformers are under operation to have a single phase power supply together with a phase angle of $90^{\circ}$ on the secondary side of the main transformer. In the case of an internal fault of the transformer, the transformer protection relay should be cut off on the primary side, the transformer should be inoperative to the external fault of the transformer or to the normal train operation. Reducing the malfunction of the relay through an exact fault determination is very important for securing a stable power system and improving its reliability. The main transformers are protected using Buchholtz's relay and a differential relay as the internal fault detection devices, but there are some cases of the main transformer operation under the deactivation of this protection function due to a malfunction of the differential relay. In this paper, the characteristics of the SCOTT transformer and differential relay as well as the malfunctioning of the protection relays are presented. The modeling of the SCOTT transformer protection relay was accomplished by the power system analysis program and the Comtrade file from 'A substation', which was used as the input data for the fault wave, and the harmonics were analyzed to determine if the relay operates or not. In addition, an improvement plan for malfunctioning cases through wave form analysis is suggested.

Study on Degradation Characteristic of Plastic Artwork for Conservation (플라스틱 작품 보존을 위한 열화 특성 연구)

  • Yu, Ji A;Cho, Ha Jin;Han, Ye Bin;Lee, Hyun Ju;Lee, Sang Jin;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.31 no.2
    • /
    • pp.87-94
    • /
    • 2015
  • Plastic artwork can be appeared crack, change of color and whitening event by various environment conditions. A large scale plastic artwork often exhibits in outside it will be directly degraded by physical and chemical degradation factor such as strong sunlight, high humidity and rainfall. We should know degradation characteristic of plastics to prevent these damages. In this study, we studied degradation characteristic of plastics (5 types of wide use plastics; polypropylene, polystyrene, polyethylene, polyvinyl chloride, polyurethane) depending on various artificial degradation conditions such as high temperature, ultraviolet and these complex conditions (high temperature and ultraviolet). As a result, polypropylene, polystyrene and polyethylene show the most visible change especially polypropylene, polystyrene. Polypropylene didn't show a great change degree of tensile strength and contact angle, on the other hand polystyrene did. Polypropylene and polystyrene weakened by photo degradation, polyvinyl chloride and polyurethane had relatively good light stability. Also the high temperature and complex conditions were most degradation characteristic. High temperature worked for degradation catalyst because its energy can not enough worked for cut off binding energy of plastics while ultraviolet condition effected as directly degradation condition. Though following results, we expect it can be applied to investigation of degradation factor depending on plastic artwork materials and basic result of plastic artworks conservation.