• 제목/요약/키워드: Cut off angle

검색결과 85건 처리시간 0.026초

원심 다익홴의 유동에 대한 컷 오프 각도의 영향 (Effect of Cut-off Angle on Flow Pattern of Centrifugal Multi-blade Fan)

  • 강경준;신유환;이윤표;김광호
    • 한국유체기계학회 논문집
    • /
    • 제13권3호
    • /
    • pp.37-42
    • /
    • 2010
  • This study investigated on details of flow characteristics of a multi-blade fan for domestic ventilation. Experiments and analysis were carried out to describe on flow pattern with variations of cut-off angle near the scroll housing throat, which were performed by PIV measurement for the flow field and by total pressure probes. The stagnation point at cut-off region of the fan moves to the exit of the scroll housing as the cut-off angle increases. The movement of stagnation point and the variation of throat area of the scroll housing influence to the distribution of velocity magnitude at the exit of the fan. Furthermore, a large distortion of the velocity distribution at the scroll exit causes to increase mixing loss along the flow path.

신경망 기법을 이용한 다익 홴/스크롤 시스템의 컷오프 최적화 (Shape Optimization of Cut-Off in Multiblade Fan/Scroll System Using CFD and Neural Network)

  • 한석영;맹주성;유달현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.365-370
    • /
    • 2001
  • In order to minimize unstable flow occurred at a multiblade fan/scroll system, optimal angle and shape of cut-off was determined by using two-dimensional turbulent fluid field analyses and neural network. The results of CFD analyses were used for learning as data of input and output of neural network. After learning neural network optimization process was accomplished for design variables, the angle and the shape of cut-off, in the design domain. As a result of optimization, the optimal angle and shape were obtained as 71 and 0.092 times the outer diameter of impeller, respectively, which are very similar values to previous studies. Finally, it was verified that the fluid field is very stable for optimal angle and shape of cut-off by two-dimensional CFD analysis.

  • PDF

다익 홴/스크롤 시스템의 형상변수와 내부 유동장 특성과의 관계 (Some Relations Between the Geometric Parameters and Internal Flow Field Characteristics in Multiblade Fan/Scroll System)

  • 맹주성;유달현;이광호;박인규
    • 대한기계학회논문집B
    • /
    • 제24권9호
    • /
    • pp.1139-1147
    • /
    • 2000
  • This paper describes that the size of inactive zone can be directly applied to design multiblade fan/scroll system. From the experimental studies using a five hole pitot tube and smoke test, it is found that the size of inactive zone has linear relations with the mean velocity of impeller inlet and cut-off angle gives a great influences to the fan efficiency. For the practical design, a function related with geometric parameters(i.e. inner radius, cord length, cut-off clearance and cut-off angle) of fan/scroll system is suggested. By using these formulas, the size and distribution of inactive zone can be predicted without the measurements through the full domain, it can be possible to use them to know the efficiency improvement for new model designed.

PAC용 양흡입 시로코홴의 공력성능에 관한 실험적 연구 (Experimental Study on the Aerodynamic Performance of Double Inlet Sirocco Fan for a Package Air Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권1호
    • /
    • pp.58-63
    • /
    • 2013
  • The aerodynamic performance of double inlet sirocco fan is strongly dependent upon the design factors of impeller and scroll. In this paper, the change of scroll size was adopted to investigate the aerodynamic performances of double inlet sirocco fan and indoor PAC. Especially, a scroll expansion angle and a cut-off clearance ratio were considered to change the scroll size. In addition, the installation depth between double inlet sirocco fan and indoor PAC was considered. As a result, the total pressure efficiency of double inlet sirocco fan shows about 62%~73% according to the change of scroll expansion angles. Moreover, the flowrate performance of indoor PAC is the best at the condition of a scroll expansion angle of 8°, an installation depth of 15 mm and a cut-off clearance ratio of 8%.

신경망 최적화 기법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Neural Network)

  • 한석영;맹주성;유달현;진경욱
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1341-1347
    • /
    • 2002
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and neural network. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. The distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure have qualitative similarity. The results of two-dimensional CFD were used for teaming as target values of neural network. The optimal angle and radius of cut-off were determined as 71$^{\circ}$and 0.092 times the outer diameter of impeller, respectively. It is quantified in the previous report that the optimal angle and radius of cut-off are approximately 72$^{\circ}$and 0.08 times the outer diameter of impeller, respectively.

반응표면법을 이용한 다익 홴/스크롤 시스템의 설부에 대한 형상 최적화 (Shape Optimization of Cut-Off in a Multi-blade Fan/Scroll System Using Response Surface Method)

  • 한석영;맹주성;황영민
    • 한국자동차공학회논문집
    • /
    • 제11권1호
    • /
    • pp.225-231
    • /
    • 2003
  • In order to improve efficiency of a system with three-dimensional flow characteristics, this paper presents a new method that overcomes three-dimensional effects by using two-dimensional CFD and response surface method. The method was applied to shape optimization of cut-off in a multi-blade fan/scroll system. As the entrance conditions of two-dimensional CFD, the experimental values at the positions out of the inactive zone were used. In order to examine the validity of the two-dimensional CFD the distributions of velocity and pressure obtained by two-dimensional CFD were compared with those of three-dimensional CFD and experimental results. It was found that the distributions of velocity and pressure show qualitatively similarity. The results of two-dimensional CFD were used for constructing the objective function with design variables using response surface method. The optimal angle and radius of cut-off were determined as $72.4^{\circ}$ and 0.092 times the outer diameter of impeller, respectively. It is quantified the previous report that the optimal angle and radius of cut-off are approximately $72^{\circ}$ and 0.08 times the outer diameter of impeller, respectively.

차량용 헤드램프의 Cut-off Line에서 색수차 보정 및 평가 (Correction and Evaluation for Color Aberration on the Cut-off Line of a Vehicle Headlamp)

  • 심주용;박성찬
    • 한국광학회지
    • /
    • 제30권1호
    • /
    • pp.8-14
    • /
    • 2019
  • 본 논문에서는 추가적인 광학부품 및 조립공정 없이 차량용 헤드램프의 cut-off line에서 발생하는 색수차를 보정하는 방법과 이를 평가하는 방법을 제안한다. 기하학적인 방법으로 색수차를 보정하기 위해 비구면 프로젝션 렌즈의 볼록면에 tilt를 적용하여 파장별 최대 출사각도의 차이를 줄였으며, 색수차를 평가하기 위한 위치와 광도를 정하고 색 좌표를 통해 색수차 기준을 제시하였다. 이러한 기하학적인 방법을 이용하여 설계된 자동차용 헤드램프를 평가한 결과 cut-off line의 색수차가 상당히 감소되었음을 확인할 수 있었다.

최소자승법을 이용한 상보필터의 설계 (Design of Complementary Filter using Least Square Method)

  • 민형기;윤주한;김지훈;권성하;정은태
    • 제어로봇시스템학회논문지
    • /
    • 제17권2호
    • /
    • pp.125-130
    • /
    • 2011
  • This paper shows a method to design complementary filter using least square. The complementary filter is one of useful filters estimating angle. The basic concept of this filter is to enhance advantages of each sensor that angle detecting using a gyroscope has good accuracy at a high frequency and an accelerometer at a low frequency. When designing complementary filter, the most commonly used method is using cut-off frequency. However, it may be not easy to obtain a cut-off frequency. This paper presents a systematic method to determine the coefficients of the complementary filter using well-known linear least squares minimizing error between estimating angle and true angle.

PMMA 기판에 CeO2와 SiO2를 코팅하여 제작한 적외선 차단필터 (IR Cut-off Filter Made of CeO2 and SiO2 Thin Films Coated on PMMA Substrate)

  • 유연석;최상석
    • 한국광학회지
    • /
    • 제17권5호
    • /
    • pp.480-486
    • /
    • 2006
  • 일반적으로 모바일 폰용 적외선 차단 필터는 유리기판위에 $300^{\circ}C$ 이상의 고온에서 코팅된다. 본 연구에서는 PMMA(Poly methyl methacrylate)기판에 저온에서 $CeO_2$$SiO_2$를 사용하여 적외선 차단 필터를 코팅하였다. 저온 코팅된 필터의 접촉각을 측정하여 박막의 부착상태를 시험하였고, 적외선 차단 필터에 대한 시험 및 설계 결과를 모바일 폰용 광학계 개선에 적용하여 보았다.

The Visual Performance Evaluation of the Work planes with the Automated blind Control in Small Office Spaces

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • 제14권1호
    • /
    • pp.15-22
    • /
    • 2014
  • Among the various building envelope elements, the glass area takes up the largest portion in the office building design. However, a large area of glass can cause problems such as excessive solar radiation, thermal comfort, and glare. Thus it is important to install the glass area to an appropriate level, and control solar radiation and inflow of daylight with blind devices. This study aims to improve the visual performance of the work plane through the automatic control of the venetian blinds. A total of eight kinds of control strategies were chosen; Case 1 does not control the blinds, Case 2 with the blind slats fixed at the angle of 0 degree, Case 3 to 6 using the existing blind control programs, and Case 7 and 8 with improved blind control. Case 3 with 90 degrees had the best energy performance, but the average indoor illuminance was 113lux, which is below the standards. Cases 4 and 5 showed higher levels of interior daylight illuminance with the average of 281lux and 403lux respectively. However, the fixed angles may have difficulties controlling excessive direct sunlight coming into the room and may cause glare. Cases 6 and 7 used sun tracking angle control and cut-off angle control, and the average interior illuminance was measured 250lux and 385lux respectively. Case 8 used the cut-off angle control in an hourly manner, satisfying the standard illuminance of 400lux with an average interior illuminance of 561lux. It was evaluated to be the best method to control direct solar radiation and to guarantee proper level of interior illumination.