• Title/Summary/Keyword: Cut enamel

Search Result 45, Processing Time 0.028 seconds

Effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion (상아세관 폐쇄에 대한 2종의 상아질 지각 과민 체치제와 Er,Cr:YSGG 레이저의 효과)

  • Kim, Na-Song;Kang, Jeong-Kyung;Ryu, Jae-Jun
    • The Journal of the Korean dental association
    • /
    • v.48 no.6
    • /
    • pp.469-477
    • /
    • 2010
  • The purpose of this study was to evaluate the effect of two dentin desensitizers and Er,Cr:YSGG laser for dentinal tubule occlusion. Twenty recently extracted single-rooted human teeth were used to obtain root dentinal fragments. The crowns were cut approximately 1mm below the cementum enamel junction(CEJ). A second cut was used to remove the apex of the root. Subsequently, a longitudinal cut was made in order to obtain 2 fragments from each root sample. The cementum from the cervical portion was removed using a high-speed diamond-coated bur in order to expose the dentin. To open dentinal tubules, forty samples were treated with 50% citric acid for 2 min and then rinsed under distilled water for 1 min. These were divided into four groups of ten samples each. The first group served as a control group. In group 2, the samples were irradiated with the Er,Cr:YSGG laser(Waterlase MD, Biolase, USA). In group 3, the samples were treated with Bisblock and ONE-STEP PLUS(Bisco, USA). In group 4, the samples were treated with Gluma comfort bond & Desensitizer(Heraeus Kulzer, Germany). All the samples were examined using Scanning electron microscopy(Hitachi, S-4700, Japan) with two different magnifications(X2000, X5000). These images were assessed by one examiner who was blind to the experimental procedure, using the index of smear layer removal. The distribution of smear layer removal grades was tested using Fisher's exact test. On the order hand, in order to evaluate the occluding effect of two dentin desensitizers and Er,Cr:YSGG laser, the number of exposed dentinal tubules was counted in each group. These were evaluated using the Kruskal-Wallis test with significance predetermined $\alpha$=0.05. There were statistically significant differences between the three groups(Er,Cr:YSGG laser, Bisblock+ONE-STEP PLUS, Gluma comfort bond & Desensitizer) and control group.

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE MARGINAL ADAPTIBILITY IN APPLYING THE CAVITY VARNISH AND DENTIN BONDING AGENT IN AMALGAM RESTORATIONS (아말감 수복시(修復時) Cavity varnish와 Bonding agent 도포(塗布)에 따른 접합성(接合性)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Kim, Seok-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.107-119
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal adaptability of the amalgam restorations in applying the cavity varnish (Copalite$^{(R)}$) and dentin bonding agent (Scotchbond 2$^{(R)}$) under the scanning electron microscope. For this study, eighteen sound extracted human molars were selected. Class I cavities in 12 teeth and class V cavities in 6 teeth were prepared using an air turbine with No. 701 tungsten carbide bur and finished using a low speed handpiece with No. 557 fissure bur. The prepared specimens were then divided into three groups including 4 class I cavities and 2 class V cavities in each group and restored as follows ; Group I. All the prepared cavities were restored with amalgam only (Control). Group II. Two layers of Copalite$^{(R)}$ cavity varnish were applied to the cavities with a gentle stream of air after each application and cavities were restored with amalgam. Group III. The enamel cavity margins were etched with 37% phosphoric acid gel for 60 sec., rinsed for 30 sec. and dried. One layer of visible lightcured Scotchbond Dental Adhesive$^{(R)}$ was applied and immediately cured for 20 seconds with visible light-cure unit and cavities were restored with amalgam. All the specimens were cut at the neck of the teeth and the occlusal halves of specimens were sectioned buccolingually in the longitudinal axis centering the amalgam restorations, using the disk. The cut specimens were ground with sandpapers (400, 600, 800, 1000 grit), and cleaned for 5 minutes in the ultrasonic cleaner (Brason Co. U.S.A.). In the cut surfaces, the amalgam - tooth interfaces were examined under the scanning electron microscope (JSM, 35C type, JEOL). The obtained results were as follows ; 1. The amalgam-tooth interfaces were reduced more significantly in the Copalite$^{(R)}$ and Scotchbond 2$^{(R)}$ application group than in the control group. 2. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed the findings similar to the Copalite$^{(R)}$ application group in the cavity floor, and the marginal adaptability was better in the side wall than in the cavity floor. 3. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed better marginal adaptability in the occlusal margin than in the gingival margin. 4. The marginal adaptability was in the order of the Scothbond 2$^{(R)}$ application group, the Copalite$^{(R)}$ application group and the control group.

  • PDF

The Microleakage in Class V Cavity Based on Different Kinds of Several Dentin Adhesive and Composite Resin (5급 와동에서 수종의 상아질 접착제와 복합레진의 종류에 따른 미세누출)

  • Choi, Yoo-Seok;Jeong, Soon-Jeong;Jeong, Moon-Jin;Ahn, Yong-Soon;Park, Seon-Nyeo;Lim, Do-Seon
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.330-338
    • /
    • 2013
  • In order to explore microleakage in class V cavity based on different kinds of several dentin adhesive and composite resin, 2 kinds of composite resin was restored and exposed after applying 4 kinds of dentin adhesives. Deposited in methylene blue solution for 4 hours and cut in parallel with tooth longitudinal axis. By observing dye penetration level of enamel and dentin margins of each restored resin following conclusion was obtained. 1. In composite resin Filtek Z350XT Universal (3M/ESPE Dental Products, USA) in enamel margin, Easy Bond (3M/ESPE Dental Products) showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2 (3M/ESPE Dental Products), Scotchbond Multi-Purpose (3M/ESPE Dental Products) and Cearfil SE Bond (Kuraray Medical Inc., Japan). In case of Filtek Z350XT Flowable (3M/ESPE Dental Products), Scotchbond Multi-Purpose showed the lowest microleakage and this leakage was represented to be high in the order of Single Bond 2, Clearfil SE Bond and Easy Bond. 2. In case of Filtek Z350XT Universal in dentin margin, Easy Bond showed the lowest microleakage and this leakage was represented to be high in the order of Scotchbond Multi-Purpose, Single Bond 2 and Clearfil SE Bond. In case of Filtek Z350XT Flowable, Scotchbond Multi-Purpose and Single Bond showed the lowest microleakage and this leakage was represented to be high in the order of Clearfil SE Bond and Easy Bond. 3. In all the groups excepting S-U group (Single Bond 2+Filtek Z350XT Universal), enamel margin showed more higher microleakage than that of dentin margin. 4. There was a difference between enamel and dentin margin among each group but it was not significant statistically (p>0.05). When summarizing this result, it is considered that composite resin and dentin adhesive could be applied selectively and particularly in case of applying 1-step self-etching dentin adhesive, this method would be advantageous for manipulation convenience and shortening of operation time.

DEVELOPMENT OF FILTERING SYSTEM OF LASER FLUORESCENCE FOR IMPROVEMENT OF THE DIAGNOSTIC SENSITIVITY FOR DENTAL CARIES (레이저 형광법의 치아우식증 진단감도를 증진시키기 위한 필터링 시스템 개발)

  • Lee, Sang-Ho;Park, Jong-Whi;Kook, Jung-Ki;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • The objective of this study is to improve the optical sensitivity of laser fluorescence for detection of incipient enamel caries. An incipient carious lesion was formed in various stages by placing an enamel specimen of a bovine tooth in STPP demineralization solution. After measuring the optical density of the lesion surface by laser fluorescence induced by argon laser and various alter of yellow(500-520nm), amber(520-540nm), orange(540-560nm), and red(560-580nm), the specimen was cut vertically to measure the depth of the lesion using a polarizing microscope. SAS statistical program was used to analyze the relationship between the optical density of the lesion suface and the depth of the lesion. The results were as follows: 1. The optical density of early carious lesion, measured by laser fluorescence with amber and orange filter, and lesion depth observed by polarizing microscope, were increased as demineralization time increased. 2. The correlation coefficient between optical density of the lesion surface and the histological depth of the lesion was the highest in orange filter(r=0.49), followed by amber(r=0.32), yellow(r=0.13) and red(0.01). 3. Regression analysis showed that the most linear relationship between the optical density and the lesion depth was existed in orange filter group. In regard above results, laser fluorescence could be considered to be reliable for optical diagnosis of dental caries.

  • PDF

Comparison of Diagnostic Validity between Laser Fluorescence Devices in Proximal Caries (레이저 형광 원리를 이용한 우식 진단 기기의 구치부 인접면 우식 진단 능력 비교)

  • Lee, Changkeun;Lee, Daewoo;Kim, Jaegon;Yang, Yeonmi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.4
    • /
    • pp.426-435
    • /
    • 2018
  • The aim of this study was to evaluate the proximal caries detecting ability and identify the optimal cut-off values of two types of laser fluorescence (LF) devices; classic type (DD) and pen type (DDpen). The number of proximal surfaces participated in this study were 164 surfaces in primary dentition and 438 surfaces in permanent dentition. Each tooth surface was sequentially assessed by two types of LF devices, and bitewing radiograph. The radiographs were classified into 3 groups in primary dentition ($pR_0$, $pR_1$, $pR_2$), and 4 groups in permanent dentition ($PR_0$, $PR_1$, $PR_2$, $PR_3$) according to the depth of caries, and used as gold standard. In primary dentition, the area under the curve (AUC) values of DD were 0.851 and 0.890, and those of DDpen were 0.883 and 0.917, respectively in enamel caries and dentin caries. In permanent dentition, the AUC values of DD were 0.762 and 0.886, and those of DDpen were 0.828 and 0.958, respectively in enamel caries and dentin caries. When detecting proximal caries in posterior teeth with LF devices, DDpen is more useful than DD in both primary and permanent dentition. However, in primary dentition, DD can also be useful to detect proximal caries.

Diagnostic Utilization of Laser Fluorescence for Resin Infiltration in Primary Teeth (유치의 레진침투법을 위한 레이저 형광법의 진단적 활용)

  • Park, Soyoung;Jeong, Taesung;Kim, Jiyeon;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.265-273
    • /
    • 2019
  • This study was performed to evaluate clinical use of laser fluorescence (LF) to identify early childhood caries lesions suitable for applying resin infiltration. 20 exfoliated primary molars with proximal caries were selected and cut buccolingually cross the central pit for regarding the mesial and distal surfaces respectively. 27 specimens corresponding to ICDAS code 1 and 2 were selected and the LF values were measured. When infiltrant resin was applied, double staining for microscopy detection has done simultaneously. Tooth samples were sliced with 0.7 mm thick. The maximum lesion depth, maximum penetration depth, and average penetration rate were measured from the confocal scanning laser microscope image. Pearson correlation analysis was performed. The intraclass correlation coefficient of LF values shows excellent agreement. LF values had positive correlation with penetration rate, but not lesion depth and penetration depth. Significant correlation between LF readings and penetration rate was verified in deep enamel caries and dentin caries except shallow enamel caries. Infiltrant resin could penetrate with a higher rate and LF values could be increased in more active caries lesions. In assessing radiologically similar caries lesion, laser fluorescence might be useful for identifying caries activity.

INFLUENCE OF THE COLOR OF COMPOSITE RESINS APPLIED TO LINGUAL SURFACE ON THE LABIAL TOOTH COLOR (설측 복합레진 색상이 치아 순측 색상에 미치는 영향)

  • Mun, Seung-Hui;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.4
    • /
    • pp.309-323
    • /
    • 2009
  • In this study we evaluated the influence of both the thickness of residual enamel and the color of the composite resins applied to lingual surface on the labial surface color. Background plates were made by randomly (A1, A2, A6D, B1, B2, B3, C1, C2, C6D) selected colors of Filtek Supreme (3M ESPE, St. Paul, U.S.A.) composite resin. Crown portion of 9 maxillary central incisors were cut off and embedded with acrylic resin except labial surface. Samples of average thickness of 2.2 mm were obtained after cutting it in a thickness of 2.5 mm from the labial surface and sandpaper polish. The shade of composite resin background was measured using Spectrophotometer ($Spectrolino^{(R)}$, GretagMacbeth, Regensdorf, Switzerland). And CIE $L^{\ast}a^{\ast}b^{\ast}$value of 2.2 mm thickness tooth samples were measured on the 9 composite resin backgrounds. And then, the cutting side of tooth samples was ground to the extent of 1.9 mm, 1.6 mm, 1.3 mm, 1.0 mm and placed on composite resin backgrounds and measured $L^{\ast}a^{\ast}b^{\ast}$values with the same method. In all samples, $L^{\ast}$value and $b^{\ast}$value seemed to have a tendency of decreasing as thickness of tooth sample becomes thinner regardless of background colors (p < 0.05). But, $a^{\ast}$value didn't show the significant differences depending on the thickness.

EFFECT OF SPHERICAL SILICA FILLER ON THE PHYSICAL PROPERTIES OF EXPERIMENTAL COMPOSITES (구상형 실리카 필러가 실험적 복합레진의 물성에 미치는 효과)

  • Kang, Seung-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.88-99
    • /
    • 1999
  • The purpose of this study was to investigate the physical properties of experimental composite resins made with the spherical and crushed fillers. The 14 experimental composite resins containing 0, 5, 10, 15, 20 and 25%(w/w) in spherical filler group and 0, 10, 20, 30, 40, 50, 60 and 70%(w/w) in crushed filler group, incorporated in a Bis-GMA matrix (Aldrich Co., USA), were made with 1% ${\gamma}$-methoxy silane treated fillers. The polymer matrix was made by dissolving 0.7%(w/w) of benzoyl peroxide(Janssen Chemical Co. Japan) in methacrylate monomer, whereupon 0.7%(v/v) N,N-dimethyl-p-toluidine(Tokyo Kasei Co. Japan) was added to the monomer. The weight percentage of each specific particle size distribution could be determined from a knowledge of the specific gravity, the weight(w/w), and corresponding volume %(v/v) of the filler sample in resin monomer. In crushed silica group and spherical silica group, the diametral tensile strengths and compressive strengths were measured with Instron Testing Machine(No.4467), and analyzed in 14 experimental composite resins made by filler fractions. The shear bond strength of 14 experimental composite resins to bovine enamel was measured with universal testing machine(Instron No.4467). The fracture surfaces were sputter-coated with a gold film and investigated by SEM. The results were as follows; 1. The diametral tensile strength was tendency to increase in crushed silica group, but not in spherical silica group. The highest diametral tensile strength was found in 20% filler fractions of two groups. 2. The compressive strength was higher in 15%(w/w) and 20%(w/w) in spherical silica group than in crushed silica group, but not in spherical silica group. 3. The significant correlation was noticed in increase in shear bond strength in crushed silica group, but not in spherical silica group. 4. The significantly highest shear bond strength was noticed in 50% filler concentration in crushed silica group, and in 15% filler concentration in spherical silica group, it was not significant in relation. 5. In crushed silica group, cut surface of resin matrix and the interface between resin and filler is obvious. In spherical silica group, fractures that occurred through the filler particles were round in shape.

  • PDF

Microleakage and Anticariogenic Effect of S-PRG Filler-containing Pit and Fissure Sealant (S-PRG filler를 함유한 치면열구전색제의 미세누출 및 항우식효과)

  • Shin, Seungwoo;Kim, Jongsoo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.247-252
    • /
    • 2013
  • Pit and fissure sealant prevents biofilm accumulation, plays a role in forming a barrier to acidic substance made by the bacteria. The Surface reaction-type pre-reacted glass ionomerI(S-PRG) filler was developed in 1999. S-PRG filler releases fluoride continuously and does not decompose under wet conditions. The aim of this study was to test the microleakage and anticariogenic effect to adjacent enamel of S-PRG filler-containing pit and fissure sealant. Sound premolars and molars were used in this study. A S-PRG filler-containing pit and fissure sealant, Beautisealant$^{(R)}$(Shofu, Japan) was used for this experiment, the composite resin sealant Concise$^{(R)}$(3M ESPE, USA) was used as control. For the microleakage test, all teeth surface were double coated with finger nail varnish, with the exception of a 1.0 mm window around the restoration margins. The teeth were immersed in 2% methylene blue solution for 24 hours and then rinsed in tap water. For the anticariogenic effect evaluation, all tooth were immersed in artificial carious solution for 9 days and rinsed with tap water. Each tooth was embedded in orthodontic acrylic rein and subsequently sectioned longitudinally in a bucco-lingual direction with a low-speed diamond saw. The cut sections were examined using a stereomicroscope. Differences in microleakage between the two groups were not different significantly. But the S-PRG filler-containing pit and fissure sealant showed higher anticariogenic effect than that of flowable resin sealant.

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.