• Title/Summary/Keyword: Customized implant

Search Result 97, Processing Time 0.028 seconds

Impact on Retrievability by Cement Variety for Implant Restorations Equipped with a Lingual Slot

  • Lee, Ji-Hong;Lee, Kyu-Bok
    • Journal of Korean Dental Science
    • /
    • v.11 no.1
    • /
    • pp.14-20
    • /
    • 2018
  • Purpose: The purpose of this study is to measure and compare the removal torques of different cements applied in attachments of zirconia restorations on titanium (Ti) abutments fitted with retrievable cement-type slot (RCS) on the lingual side for the better retrievablity by use of a slot driver. Materials and Methods: Three types of cements were used in the experiment: two permanent cements in $RelyX^{TM}$ U200 (RU) (3M ESPE) which is a resin cement and $FujiCem^{TM}$ (FC) (GC) which is a resin-modified glass ionomer cement, and a temporary cement in $Freegenol^{TM}$ temporary cement (TC) (GC). Measurements of removal torques were conducted as follows; an attached sample was fixed on the equipment customized for the experiment; a slot driver was connected to a MGT12 (Mark-10 Corp.), a torque measurement instrument; the sample had the driver fitted to its RCS and then was rotated until the it was removed; and finally, the maximum torque value was recorded. Result: As for the removal torque measurement results, the average values were $47.9{\pm}2.6Ncm$ for RU, $43.4{\pm}1.5Ncm$ for FC, and $20.9{\pm}1.0Ncm$ for TC. The statistical analysis using Kruskal-Wallis test yielded the significance probability of P<0.05 (P=0.002), which confirmed the presence of significant differences between the three groups. Conclusion: All three cements exhibit clinically acceptable levels of removal torque when applied to an upper zirconia implant restoration fitted with a lingual slot, with RU and FC, the two permanent cements, having the significantly higher values than that of TC, the temporary cement.

Fit analysis of CAD-CAM custom abutment using micro-CT (Micro-CT를 이용한 맞춤형 CAD-CAM 지대주의 적합성 분석)

  • Min, Gwang-Seok;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.370-378
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate screw joint stability and sagittal fit between internal connection implant fixtures of two different manufacturers and customized abutments. Materials and methods: Internal connection implant systems from two different manufacturers (Biomet 3i system, Astra Tech system) were selected for this study (n=24 for each implant system, total n=48). For 3i implant system, half of the implants were connected with Ti ready-made abutments and the other half implants were connected with Ti CAD-CAM custom ones of domestic-make (Myplant, Raphabio Co., Seoul, Korea) and were classified into Group 1 and Group 2 respectively. Astra implants were divided into Group 3 and Group 4 in the same way. Micro-CT sagittal imaging was performed for fit analysis of interfaces and preloading reverse torque values (RTV) were measured. Results: In the contact length of fixture-abutment interface, there were no significant differences not only between Group 1 and Group 2 but also between Group 3 and Group 4 (Mann-Whitney test, P>.05). However, Group 2 and Group 4 showed higher contact length significantly than Group 1 and Group 3 in abutment-screw interface as well as fixture-screw one (Mann-Whitney test, P<.05). In addition, RTV was lower in CAD-CAM custom abutments compared to ready-made ones (Student t-test, P<.05). Conclusion: It is considered that domestically manufactured CAD-CAM custom abutments have similar fit at the fixture abutment interface and it could be used clinically. However, RTV of CAD-CAM custom abutments should be improved for the increase of clinical application.

Implant prosthesis for fully edentulous patients using intra-oral scanning and abutment merging technique: A case report (무치악 환자에서 구강 스캔과 지대주 중첩을 이용한 임플란트 보철수복 증례)

  • Hwang, Chan-Hyeon;Jeong, Seung-Mi;Kim, Yong-Jun;Kim, Kyeong-Hee;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.61-70
    • /
    • 2017
  • In this case, the impression surface of the existing denture was scanned and was inverted three-dimensionally to express the residual ridge form. Implant planning was performed on the superimposed data of the CT with the scanned image of the denture with radiopaque markers attached. At the day of surgery, customized abutments fabricated in accordance with the form of the gingival margin were linked with fixtures and temporary restorations were set. In the process of fabricating the final prosthesis after the osseointegration of implant fixture, the intraoral scan images at abutment level were merged with images of the abutments scanned and stored before implant surgery. By fabricating the final prosthesis with the abutments obtained by merging can increase the marginal fitness of the final prosthesis and simplify the clinical process.

The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs

  • Chae, Gyung-Joon;Lim, Hyun-Chang;Choi, Jung-Yoo;Chung, Sung-Min;Lee, In-Seop;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.373-384
    • /
    • 2008
  • Purpose: The aim of this study is to compare the healing response of various Hydroxyapatite(HA) coated dental implants by Ion-Beam Assisted Deposition(IBAD) placed in the surgically created circumferential gap in dogs. Materials and methods: In four mongrel dogs, all mandibular premolars and the first molar were extracted. After an 8 weeks healing period, six submerged type implants were placed and the circumferential cylindrical 2mm coronal defects around the implants were made surgically with customized step drills. Groups were divided into six groups : anodized surface, anodized surface with 150nm HA and heat treatment, anodized surface with 300nm HA and heat treatment, anodized surface with 150nm HA and no heat treatment, and anodized surface with 150nm HA, heat treatment and bone graft, anodized surface with bone graft. The dogs were sacrificed following 12 weeks healing period. Specimens were analyzed histologically and histomorphometrically. Results: During the healing period, healing was uneventful and implants were well maintained. Anodized surface with HA coating and $430^{\circ}C$ heat treatment showed an improved regenerative characteristics. Most of the gaps were filled with newly regenerated bone. The implant surface was covered with bone layer as base for intensive bone formation and remodeling. In case that graft the alloplastic material to the gaps, most of the coronal gaps were filled with newly formed bone and remaining graft particles. The bone-implant contact and bone density parameters showed similar results with the histological findings. The bone graft group presented the best bone-implant contact value which had statistical significance. Conclusion: Within the scope of this study, nano-scale HA coated dental implants appeared to have significant effect on the development of new bone formation. And additional bone graft is an effective method in overcoming the gaps around the implants.

Evaluating usability of and satisfaction with two types of dental CAD software (두 종류 치과 임플란트 캐드 소프트웨어의 사용자 편의성 및 만족도 비교)

  • Kim, Seong-Min;Lee, Wan-Sun;Son, Keunbada;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.11-19
    • /
    • 2019
  • Purpose: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who did not. Materials and Methods: Dental technicians (n = 20) who had previous experience with dental implant CAD Software and students from the College of Dentistry (n = 12) who had never designed implant custom abutments were asked to evaluate two types of CAD Software, Exocad and Deltanine. In addition, the participants were asked to fill out a structured questionnaire (Section 1: Entering basic information and retrieving files; Section 2: Setting conditions before abutment design; Section 3: Setting abutment design; and Section 4: Overall satisfaction). For the statistical analysis of the collected data, Mann-Whitney U test was used (${\alpha}=.05$). Results: The ease of design and satisfaction with the implant CAD Software, evaluated with respect to 21 statements divided into four Stages, were significantly higher for Exocad in both groups for Secion 1. For Sections 2 and 3, participants with experience evaluated Deltanine to be significantly better. For Section 4, both groups evaluated Exocad Software to be better. Conclusion: Overall, the Exocad Software was evaluated as having better usability and offering greater satisfaction. However, in terms of performance in the core of the design process, i.e. Sections 2 and 3, Deltanine was rated higher by the experienced users. Thus, if the user interface design parts are supplemented, Deltanine CAD Software could be put to a wider use in clinics.

Digital immediate implantation and aesthetic immediate loading on maxillary incisor displaced due to root fracture: a case report (치근파절로 변위된 상악 중절치의 디지털을 이용한 즉시 임플란트 식립 및 심미 수복 증례)

  • Jieun Song;Songyi Park;Chan Park;Kwidug Yun;Hyun-Pil Lim;Sangwon Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.267-275
    • /
    • 2023
  • To obtain better esthetic results when immediately placing a dental implant, the soft tissue surrounding the implant must be conditioned during healing of the extraction socket. To this end, the emergence profile can be customized through immediate restoration of the provisional prosthesis, and good clinical results can be obtained at the time of definitive restoration in the future, resulting in high patient satisfaction. In this case, horizontal root fracture occurred after trauma to both maxillary central incisors. Immediate implant placement and loading was planned considering aesthetics and alveolar bone condition. By taking an impression using a digital intraoral scanner, a digital diagnostic wax-up was performed to make a more aesthetic prosthesis without applying external force to the traumatized teeth. Based on this, the ideal placement location was determined and immediate implant placement was performed using a 3D printed surgical guide. The provisional prosthesis was restored 5 days after placement, and the definitive zirconia crown was restored through soft tissue conditioning and customization using the shape of the provisional prosthesis for 3 months.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Fiber-reinforced composite post removal using guided endodontics: a case report

  • Changgi Cho ;Hyo Jin Jo ;Jung-Hong Ha
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.50.1-50.8
    • /
    • 2021
  • Although several techniques have been proposed to remove fiber-reinforced composite (FRC) post, no safe and efficient technique has been established. Recently, a guided endodontics technique has been introduced in cases of pulp canal obliteration. This study describes 2 cases of FRC post removal from maxillary anterior teeth using this guided endodontics technique with a dental operating microscope. Optically scanned data set from plaster cast model was superimposed with the data set of cone-beam computed tomography. By implant planning software, the path of a guide drill was selected. Based on them, a customized stent was fabricated and utilized to remove the FRC post. Employing guided endodontics, the FRC post was removed quickly and safely with minimizing the loss of the remaining tooth structure. The guided endodontics was a useful option for FRC post removal.

Hard and soft tissue management in esthetic zone: A Case Report (경조직과 연조직의 증강을 통한 상악전치부 임플란트 수복: 증례보고)

  • Kim, Na-Hong;Lee, Kyu-Won;Moon, Ji-Kyung;Park, Pil-Kou;Lee, Dong-Woon
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.13-24
    • /
    • 2015
  • With the development of treatment of hard and soft tissue around the implants, the implant restoration is increasingly used in the maxillary anterior region which is very important aesthetically. However, the aesthetic reconstruction of the maxillary anterior region is still challenged. Three following conditions should be fully satisfied for aesthetic prosthesis restoration; reconstruction of hard tissue, soft tissue and harmonic prosthesis. In this case report, hard and soft tissue augmentations were performed at atrophied maxillary incisor. Additionally, customized impression coping and provisional restoration were used to make the final restoration.

Full mouth rehabilitation with implant-supported fixed prosthesis via dental CAD-CAM system (Dental CAD-CAM system을 통한 고정성 전악 임플란트 수복 증례)

  • Hong, Jeong-Min;Han, Jung-Suk;Yoon, Hyung-In;Yeo, In-Sung Luke
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • Dental implants should be placed at ideal sites for implant-supported restorations. For a patient with insufficient residual ridge, mouth preparation including surgical intervention can be indicated to establish a soft and hard tissue environment favorable for a definitive prosthesis. Prosthodontic design based on computer-guided surgery and computer-aided design-computer-aided manufacturing (CAD-CAM) provides a visual blueprint allowing a clinician to assess the necessity of such a surgical intervention beforehand. In this case, a definitive restoration was planned and made via a CAD-CAM system according to the patient's oral status before treatment, simulated surgical interventions and serial provisional restorations. Based on the planning, a guided template was made and the implants were installed with bone augmentation using the template. Customized abutments, the first and the second provisional restorations were designed and fabricated by CAD-CAM. The definitive restorations were digitally made following the shape of the second provisional prostheses, which were confirmed in the patient's mouth. The patient was satisfied with the masticatory, phonetic and aesthetic functions of these definitive prostheses.