• Title/Summary/Keyword: Curve phase

Search Result 780, Processing Time 0.028 seconds

Multiresidue matrix solid phase dispersion (MSPD) extraction and HPLC determination of tetracyclines in animal muscle tissue (시료고체상분산(matrix solid phase dispersion)전처리법을 이용한 식육중 테트라사이클린계 항생물질 동시정량분석)

  • Kang, Hwan-goo;Son, Seong-wan;Cho, Byung-hoon;Lee, Hye-sook;Park, Shin-ja;Kim, Jae-hak;Cho, Myung-haing
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.541-550
    • /
    • 1996
  • Tetracycline antibiotics have been widely used not only therapeutics but feed additives. There are many methods for the isolation and determination of tetracycline antibiotics in animal muscle tissue. But those methods take much time and labor, so it is difficult to analyse many samples simultaneously. A rapid isolation method and liquid chromatographic determination of tetracycline antibiotics in animal muscle tissue (bovine, porcine, chicken) is presented. Blank control and tetracyclines fortified samples (0.5g) were blended with $C_{18}$ containing 0.05g each of oxalic acid and disodium ethylenediaminetetraacetate. After homogenize, homogenate was transferred to glass column made from 10ml glass syringe and compressed to 4~4.5ml volume. A column made from the $C_{18}$/meat matrix was washed with hexane (8ml) and dichloromethane (8ml, if needed), following which the tetracyclines were eluted,vith methanol or 0.01M methanolic oxalic acid (8ml). The eluates containing tetracyclines analytes were free from interfering compounds when analysed by HPLC with UV detection (photodiode array at 360nm). Standard curve for each tetracycline showed a linear response at the range of $0.05{\sim}1.0{\mu}g/ml$ and tetracycline antibiotics were eluted within 4ml of eluted volume. All tetracycline antibiotics except tetracycline were stable during the concentration process at $40^{\circ}C$ and time required for concentration was 3~4 hours. Fortified samples containing oxalic aicd and EDTA represented more good recoveries than those of not-contained sample. Recoveries were 91.8~110.1% (oxytetracycline; OTC), 57.7~79.5% (tetracycline; TC), 78.1~88.6% (chlortetracyclines; CTC) and 88.4~100.6% (doxycycline; DC) in pork tissue, 101.1~126.8% (OTC), 66.4~75.4% (TC), 79.2~88.1% (CTC) and 69.3~86.7% (DC) in beef tissue, and 90.8~95.6% (OTC), 66.2~84.4% (TC), 75.7~77.2% (CTC) and 55.6~80.7% (DC) in chicken muscle tissue. The detection limits validated in muscle tissue by this method were $0.05{\mu}g/g$ for OTC and TC, and $0.1{\mu}g/g$ for CTC and DC.

  • PDF

Pharmacokinetics of oxytetracycline in rabbits after intravenous and intramuscular administrations (토끼에서 oxytetracycline의 정맥 및 근육 투여시의 약물동태학)

  • Kim, Eun-jung;Yun, Hyo-in;Park, Seung-chun;Oh, Tae-kwang;Cho, Chun-hyung
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.2
    • /
    • pp.259-266
    • /
    • 1994
  • The study was carried out to determine the pharmacokinetic parameters after intravenous(iv) and intramuscular(im) administration (10mg/kr) in healthy rabbits. The results obtained through the experiments were summarized as follows: 1. Bioassay (Bacillus cereus 11778) was evaluated very useful for the determination of oxytetracycline(OTC) in the rabbit serum and tissues, with the detection limit of $0.125{\mu}g/ml$. 2. The pharmacokinetic profiles of OTC (10mg/kg, iv) in rabbits were best described with a two compartment open model $(C=29.5e^{-4,3t}{\pm}3.6^{-0.2t})$, whereas that of OTC (10mg/kg, im) showed a one compartment curve fitting. 3. Following iv administration, a rapid distribution phase was predominant [$t_{\frac{1}{2}}({\alpha}):1.43{\pm}0.98hr$ (♂), $0.5{\pm}0.1hr$(♀)], and then more slow elimination phase ensued [$t_{\frac{1}{2}}({\beta}):4.52{\pm}0.76hr$(♂), $7.32{\pm}2.52hr$(♀)]. Other computer generated pharmacokinetic values were as follows:C1 [$67.76{\pm}18.59ml/kg/h$(♂), $76.03{\pm}22.98ml/kg/h$ (♀)] Vd [$257.74{\pm}180.47ml/kg$ (♂), $92.33{\pm}23.62$ (♀)] AUC [$25.6{\pm}4.44mgh/L$ (♂), $39.6{\pm}12.13mgh/l$ (♀)]. There were no statistical significance between both sexes for all the parameters at the confidence level of 95%. 4. After im administaration, the absorption from the injection sites was very rapid [ Ka:$0.18{\pm}0.03h^{-1}$ (♂), $0.24{\pm}0.02h^{-1}$ (♀)] followed by a monoexponential elimination fashion. The time to peak blood level (Tmax) were calculated $1.64{\pm}0.15hr$ and $1.34{\pm}0.24hr$, in the male and female, respectively. The peak levels (Cmax) at the corresponding time were $1.69{\pm}0.23{\mu}g/ml$ (♂) and $2.08{\pm}0.16{\mu}g/ml$ (♀), with no statistical differences (p>0.05).

  • PDF

Magnetic Properties of Ti0.96Co0.02Fe0.02O2 (Ti0.96Co0.02Fe0.02O2의 자기적 특성)

  • Kim, E.C.;Lee, S.R.;Kim, S.J.;Han, G.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.17 no.1
    • /
    • pp.43-46
    • /
    • 2007
  • The samples were synthesized by using a solid state reaction. The X-ray diffraction pattern for $Ti_{0.96}Co_{0.02}Fe_{0.02}O_2$ showed a pure rutile phase with tetragonal structures. Mixtures of the proper proportions of the elements sealed in evacuated quartz ampoule were heated at $870{\sim}930^{\circ}C$ for one day and then slowly cooled down to room temperature at a rate of $10^{\circ}C/h$. In order to obtain single phase material, it was necessary to grind the sample after the first firing and to press the powders into pellets before annealing them for a second time in evacuated and sealed quartz ampoule. Magnetic properties have been investigated using the vibrating sample magnetometer(VSM). Room temperature magnetic hysteresis(M-H) curve showed an obvious ferromagnetic behavior and the magnetic moment per Fe atom under the applied of 0.8T was estimated to be about $1.3{\mu}_B/CoFe$. But the magnetic moment per Fe atom under the applied of 0.8T was estimated to be about $0.02{\mu}_B/CoFe$ without Ti-getter.

Magnetoresistance characteristics of EeN/Co/Cu/Co system spin-valve type multilayer (FeN/Co/Cu/Co계 spin-valve형 다층악의 자기저항 특성)

  • 이한춘;송민석;윤성호;김택기
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.210-219
    • /
    • 2000
  • The magnetoresistance characteristics of FeN/Co/Cu/Co and FeN/Co/Cu/Co/Cu/Co/FeN multilayers using ferromagnetic iron-nitrides (FeN) has been studied. The microstructure of FeN film is the mixed ${\alpha}$-Fe and $\varepsilon$-Fe$_3$N phase on the condition that the flow rate of N$_2$ gas is over 0.4 sccm. The magnetoresistance effect is observed because of shape magnetic anisotropy induced by needle-shaped $\varepsilon$-Fe$_3$N phase. This magnetoresistance effect changes, because the degree that the shape magnetic anisotropy adheres to the adjacent Co pinned layer is varied according to the flow rate of N$_2$ gas and the thickness of FeN film. The best magnetoresistance effect is obtained on the condition that the thickness of Co free layer is 70 ${\AA}$ and the maximum MR ratio(%) value of 3.2% shows in the FeN(250 ${\AA}$)/Co(70 ${\AA}$)/Cu(25 ${\AA}$)/Co(70 ${\AA}$)/Cu(25 ${\AA}$)/Co(70 ${\AA}$)/FeN(250 ${\AA}$) mutilayer film which is fabricated at the N, gas flow rate of 0.5 sccm and the FeN film thickness of 250 ${\AA}$. Four steps are observed in the magnetoresistance curve owing to this difference of coercive force, because respective magnetic layers in the multilayer possess different coercive forces. These effects observed in these mutilayer films can be expected to application to the memory device the same MRAM as can carry out simultaneously four signals.

  • PDF

Characteristics of the Extracellular Proteolytic Enzyme Produced by Candida lipolytica FM5 Isolated from Mackerel (Scomber japonicus) (Candida lipolytica FM5가 생산하는 균체외 단백분해효소의 특성)

  • PARK Mi-Yeon;OH Eun-Gyong;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.5
    • /
    • pp.631-636
    • /
    • 1998
  • Candida lipolytica(C. lipolytica) FM5 was selected as one of the strong saprophytic yeasts isolated from mackerel (Scomber japonicus). The selected strain could produce extracellular proteolytic enzyme. The effective medium for production of proteolytic enzyme by C. lipolytica FM5 was TPPY broth containing Bacto-tryptone $0.5\%$, proteose peptone $0.5\%$, yeast extract $0.25\%$, NaCl $0.5\%$ and $CaCl_2\;0.2\%$. The pattern of proteolytic enzyme production by C. lipolytica FM5 was the almost same as that of growth curve of the strain. Namely, the enzyme production was begun from the early stage of exponential phase and it was reached the highest at the begining of the stationary phase of the yeast growth. The optimum toeperature of the produced proteolytic enzyme was $35^{\circ}C$ and its activity was not significantly changed by pH between 6.5$\~$9.0 and also it was not significantly affected by several kinds of cations such as $Ca^{2+},\;Cu^{2+},\;Fe^{2+}$ and $Mg^{2+}$ but it was affected negatively by some cations such as $Zn^{2+},\;Mn^{2+}$ and $K^+$.

  • PDF

Effect of Polymer Backbone Architecture on the Phase Behavior of Poly(ethylene-co-octene) + cyclo-Hydrocarbon Mixtures (Poly(ethylene-co-octene) /고리형탄화수소 2성분계 혼합물의 상거동에 대한 고분자 사슬구조의 영향)

  • Lee, Sang-Ho;Chuug, Sung-Yun;Sohn, Jin-Eun
    • Elastomers and Composites
    • /
    • v.40 no.4
    • /
    • pp.277-283
    • /
    • 2005
  • LV transition curves for poly(ethylene-co-15.3 mol% octene) ($PEO_{15}$) and poly(ethylene- co-17.0 mol% octene) ($PEO_{17}$) were measured in cyclo-pentane and cyclo-hexane. Between $40{\sim}150^{\circ}C$, the LV curve for ($PEO_{15}$ + cyclo pentane) located $1.1{\sim}2.7$ bar higher than that for ($PEO_{17}$+ cyclo-pentane). In cyclo-hexane, similar behavior was observed for $PEO_{15}$ and $PEO_{17}$ solution except the pressure difference reduced to $0.9{\sim}l.6$ bar. If the backbone structure of $PEO_{15}$ were identical to that of $PEO_{17}$, the LV line for $PEO_{17}$ would locate at high pressures than that for $PEO_{15}$, since the number average molecular weight of $PEO_{17}$ (Ave. Mn=153,040) is 1.9 times higher 4han that of $PEO_{15}$ (Ave. Mn=82,200). The difference in the octene comonomer content between $PEO_{15}$ and $PEO_{17}$ is only 1.7 mole%, nevertheless this small difference in the backbone structure of the PEO greatly affected the location of the L-V curves in the mixtures comprised of PEO and cyclo-alkane.

Effect of Lithium Contents and Applied Pressure on Discharge Characteristics of Single Cell with Lithium Anode for Thermal Batteries (리튬 함량 및 단위 셀 압력이 열전지용 리튬 음극의 방전 성능에 미치는 영향)

  • Im, Chae-Nam;Ahn, Tae-Young;Yu, Hye-Ryeon;Ha, Sang Hyeon;Yeo, Jae Seong;Cho, Jang-Hyeon;Yoon, Hyun-Ki
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.2
    • /
    • pp.165-173
    • /
    • 2019
  • Lithium anodes (13, 15, 17, and 20 wt% Li) were fabricated by mixing molten lithium and iron powder, which was used as a binder to hold the molten lithium, at about $500^{\circ}C$ (discharge temp.). In this study, the effect of applied pressure and lithium content on the discharge properties of a thermal battery's single cell was investigated. A single cell using a Li anode with a lithium content of less than 15 wt% presented reliable performance without any abrupt voltage drop resulting from molten lithium leakage under an applied pressure of less than $6kgf/cm^2$. Furthermore, it was confirmed that even when the solid electrolyte is thinner, the Li anode of the single cell normally discharges well without a deterioration in performance. The Li anode of the single cell presented a significantly improved open-circuit voltage of 2.06 V, compared to that of a Li-Si anode (1.93 V). The cut-off voltage and specific capacity were 1.83 V and $1,380As\;g^{-1}$ (Li anode), and 1.72 V and $1,364As\;g^{-1}$ (Li-Si anode). Additionally, the Li anode exhibited a stable and flat discharge curve until 1.83 V because of the absence of phase change phenomena of Li metal and a subsequent rapid voltage drop below 1.83 V due to the complete depletion of Li at the end state of discharge. On the other hand, the voltage of the Li-Si anode cell decreased in steps, $1.93V{\rightarrow}1.72V(Li_{13}Si_4{\rightarrow}Li_7Si_3){\rightarrow}1.65V(Li_7Si_3{\rightarrow}Li_{12}Si_7)$, according to the Li-Si phase changes during the discharge reaction. The energy density of the Li anode cell was $807.1Wh\;l^{-1}$, which was about 50% higher than that of the Li-Si cell ($522.2Wh\;l^{-1}$).

Diagnostic Image Feature and Performance of CT and Gadoxetic Acid Disodium-Enhanced MRI in Distinction of Combined Hepatocellular-Cholangiocarcinoma from Hepatocellular Carcinoma

  • Kim, Hyunghu;Kim, Seung-seob;Lee, Sunyoung;Lee, Myeongjee;Kim, Myeong-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.313-322
    • /
    • 2021
  • Purpose: To find diagnostic image features, to compare diagnostic performance of multiphase CT versus gadoxetic acid disodium-enhanced MRI (GAD-MRI), and to evaluate the impact of analyzing Liver Imaging Reporting and Data System (LI-RADS) imaging features, for distinguishing combined hepatocellular-cholangiocarcinoma (CHC) from hepatocellular carcinoma (HCC). Materials and Methods: Ninety-six patients with pathologically proven CHC (n = 48) or HCC (n = 48), diagnosed June 2008 to May 2018 were retrospectively analyzed in random order by three radiologists with different experience levels. In the first analysis, the readers independently determined the probability of CHC based on their own knowledge and experiences. In the second analysis, they evaluated imaging features defined in LI-RADS 2018. Area under the curve (AUC) values for CHC diagnosis were compared between CT and MRI, and between the first and second analyses. Interobserver agreement was assessed using Cohen's weighted κ values. Results: Targetoid LR-M image features showed better specificities and positive predictive values (PPV) than the others. Among them, rim arterial phase hyperenhancement had the highest specificity and PPV. Average sensitivity, specificity, and AUC values were higher for MRI than for CT in both the first (P = 0.008, 0.005, 0.002, respectively) and second (P = 0.017, 0.026, 0.036) analyses. Interobserver agreements were higher for MRI in both analyses (κ = 0.307 for CT, κ = 0.332 for MRI in the first analysis; κ = 0.467 for CT, κ = 0.531 for MRI in the second analysis), with greater agreement in the second analysis for both CT (P = 0.001) and MRI (P < 0.001). Conclusion: Rim arterial phase hyperenhancement on GAD-MRI can be a good indicator suggesting CHC more than HCC. GAD-MRI may provide greater accuracy than CT for distinguishing CHC from HCC. Interobserver agreement can be improved for both CT and MRI by analyzing LI-RADS imaging features.

Simultaneous Analysis of Cold Medicine Component by High-Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 Cold Medicine 성분의 동시 분석)

  • Wonju Lee;Seung-Tae Choi;Keun-Sik Shin;Jin-Young Park;Jae-Ho Sim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.867-873
    • /
    • 2023
  • In this study, for the purpose of standardized quality control of a cold medicine, we simultaneous analyzed four main chemical components of a cold medicine: acetaminophen, caffeine, methyl paraben, and propyl paraben. The sample was subjected to quantitative analysis using high performance liquid chromatography (HPLC), after pretreatment of four components. The experiment was carried out by using Isocratic elution at wavelength of 270nm. Acetonitrile and water (H2O) were used as a mobile phase at a flow rate of 1.0mL/min in a commercial C18 reversed-phase column. A volume of 10uL cold medicine were injected into the column with column oven temperature at 35℃. As a result of the experiment, the values of Resolution were 4.983, 1.596, 5.519, and 1.678 respectively-well over Rs >1.5, which indicates that the separation of four components were efficient. In addition, value of symmetry factor of the components was 1.056, 1.069, 1.032, and 1.133 respectively, to show its symmetrical stability. The calibration curve of all four components exhibits good linearity with R2 >0.9995 to 0.9999. Furthermore, the limit of detection(LOD) were between 0.0118 to 1.5973 mg/mL, while the limit of quantification (LOQ) were between 0.0353 to 4.7919 ㎍/mL with the recovery rate of 79.6% ~ 120.5%. The results of this study showed an efficient quality evaluation of a simultaneous analysis method for cold medicine components.

Deep Learning-Based Assessment of Functional Liver Capacity Using Gadoxetic Acid-Enhanced Hepatobiliary Phase MRI

  • Hyo Jung Park;Jee Seok Yoon;Seung Soo Lee;Heung-Il Suk;Bumwoo Park;Yu Sub Sung;Seung Baek Hong;Hwaseong Ryu
    • Korean Journal of Radiology
    • /
    • v.23 no.7
    • /
    • pp.720-731
    • /
    • 2022
  • Objective: We aimed to develop and test a deep learning algorithm (DLA) for fully automated measurement of the volume and signal intensity (SI) of the liver and spleen using gadoxetic acid-enhanced hepatobiliary phase (HBP)-magnetic resonance imaging (MRI) and to evaluate the clinical utility of DLA-assisted assessment of functional liver capacity. Materials and Methods: The DLA was developed using HBP-MRI data from 1014 patients. Using an independent test dataset (110 internal and 90 external MRI data), the segmentation performance of the DLA was measured using the Dice similarity score (DSS), and the agreement between the DLA and the ground truth for the volume and SI measurements was assessed with a Bland-Altman 95% limit of agreement (LOA). In 276 separate patients (male:female, 191:85; mean age ± standard deviation, 40 ± 15 years) who underwent hepatic resection, we evaluated the correlations between various DLA-based MRI indices, including liver volume normalized by body surface area (LVBSA), liver-to-spleen SI ratio (LSSR), MRI parameter-adjusted LSSR (aLSSR), LSSR × LVBSA, and aLSSR × LVBSA, and the indocyanine green retention rate at 15 minutes (ICG-R15), and determined the diagnostic performance of the DLA-based MRI indices to detect ICG-R15 ≥ 20%. Results: In the test dataset, the mean DSS was 0.977 for liver segmentation and 0.946 for spleen segmentation. The Bland-Altman 95% LOAs were 0.08% ± 3.70% for the liver volume, 0.20% ± 7.89% for the spleen volume, -0.02% ± 1.28% for the liver SI, and -0.01% ± 1.70% for the spleen SI. Among DLA-based MRI indices, aLSSR × LVBSA showed the strongest correlation with ICG-R15 (r = -0.54, p < 0.001), with area under receiver operating characteristic curve of 0.932 (95% confidence interval, 0.895-0.959) to diagnose ICG-R15 ≥ 20%. Conclusion: Our DLA can accurately measure the volume and SI of the liver and spleen and may be useful for assessing functional liver capacity using gadoxetic acid-enhanced HBP-MRI.