• 제목/요약/키워드: Curvature of Radius

검색결과 581건 처리시간 0.034초

3D Printing Watermarking Method Based on Radius Curvature of 3D Triangle

  • Pham, Ngoc-Giao;Song, Ha-Joo;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • 한국멀티미디어학회논문지
    • /
    • 제20권12호
    • /
    • pp.1951-1959
    • /
    • 2017
  • Due to the fact that 3D printing is applied to many areas of life, 3D printing models are often used illegally without any permission from the original providers. This paper presents a novel watermarking algorithm for the copyright protection and ownership identification for 3D printing based on the radius curvature of 3D triangle. 3D triangles are extracted and classified into groups based on radius curvature by the clustering algorithm, and then the mean radius curvature of each group will be computed for watermark embedding. The watermark data is embedded to the groups of 3D triangle by changing the mean radius curvature of each group. In each group, we select a 3D triangle which has the nearest radius curvature with the changed mean radius curvature. Finally, we change the vertices of the selected facet according to the changed radius curvature has been embedded watermark. In experiments, the distance error between the original 3D printing model and the watermarked 3D printing model is approximate zero, and the Bit Error Rate is also very low. From experimental results, we verify that the proposed algorithm is invisible and robustness with geometric attacks rotation, scaling and translation.

반치환 슬관절의 설계 평가를 위한 굴곡각도에 따른 곡률반경과 접촉응력의 상관도 분석 (The Correlation Analysis through the Contact Stress and the Curvature Radius according to Flexion Angle for the Design of Unicompartment Knee Replacement)

  • 이용경;유의식;김재원;임도형;정태곤;김정성
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권6호
    • /
    • pp.215-221
    • /
    • 2016
  • Conformity between the femoral component and tibial insert within the knee replacement may be measured in frontal or sagittal view, and shows differences in the curvature radius of the femoral component depending on the flexion angle, i.e., curvature radius has a complex effect on contact stress. Therefore, it is essential to confirm how the curvature radius effects contact stress, and provide an important variable to reduce contact stress. This study correlated contact stress with curvature radius measured in frontal and the sagittal views and confirmed the effect of curvature radius for assessment of the Newly Designed Unicompartment Knee Replacement (NDUKR). Finite element models were constructed for NDUKR and $Zimmer^{(R)}$ Unicompartment High Flex Knee Replacement system (ZUKR), incorporating the curvature radius as measured in either frontal or sagittal view. The femoral component had 1200N of compressive load applied approximately 1.65xbody weight. Contact stress was predicted at flexion angles $0^{\circ}C$, $30^{\circ}C$, $60^{\circ}C$, $90^{\circ}C$ and $120^{\circ}C$, for NDUKR: 42, 47.7, 47.7, 51.2, and 54.1 MPa, and ZUKR: 41.2, 49.5, 53.2, 54.3, and 57.4 MPa, respectively. Correlation analysis showed the influence of curvature radius measured from the sagittal view was larger than for frontal view.

하악 대구치의 II형 근심 근관에서 치근단 부위의 만곡도 조사 (An evaluation of canal curvature at the apical one third in type II mesial canals of mandibular molars)

  • 윤혜림;이동균;황호길
    • Restorative Dentistry and Endodontics
    • /
    • 제37권2호
    • /
    • pp.104-109
    • /
    • 2012
  • Objectives: The purpose of this study was to evaluate the buccolingual curvature at the apical one third in type II mesial canals of mandibular molars using the radius and angle of curvature. Materials and Methods: Total 100 mandibular molars were selected. Following an endodontic access in the teeth, their distal roots were removed. #15 H- or K-files (Dentsply Maillefer) were inserted into the mesiobuccal and mesiolingual canals of the teeth. Radiographs of the teeth were taken for the proximal view. Among them, type II canals were selected and divided into two subgroups, IIa and IIb. In type IIa, two separate canals merged into one canal before reaching the apex and in type IIb, two separate canals merged into one canal within the apical foramen. The radius and angle of curvature of specimens were examined. Results: In type II, mean radius of curvature in mesiolingual and mesiobuccal canals were 2.82 mm and 3.58 mm, respectively. The radius of the curvature of mesiolingual canals were significantly smaller than that of mesiobuccal canals in type II, and especially in type IIa. However, there were no statistically significant differences in radius of curvature between mesiobuccal and mesiolingual canals in type IIb and there were no significant differences in angle of curvature between type IIa and IIb. Conclusion: In this study, type II mesial canals of mandibular molars showed severe curvature in the proximal view. Especially, mesiolingual canals of type IIa had more abrupt curvature than mesiobuccal canals at the apical one third.

임계노즐 유동에 미치는 노즐 곡률의 영향 (Effect of the Nozzle Curvature on Critical Flows)

  • 김재형;김희동;박경암
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.331-336
    • /
    • 2002
  • Recently the critical nozzles with small diameter are being extensively used to measure mass flow in a variety of industrial fields and these have different configurations depending on operation condition and working gas. The curvature radius of the critical nozzle throat is one of the most important configuration factors promising a high reliability of the critical nozzle. In the present study, computations using the axisymmetric, compressible, Navier-Stokes equations are carried out to investigate the effect of the nozzle curvature on critical flows. The diameter of the critical nozzle employed is D=0.3mm and the radius of curvature of the critical nozzle throat is varied in the range from 1D to 3D. It is found that the discharge coefficient is very sensitive to the curvature radius(R) of critical nozzle, leading to the peak discharge coefficient at R = 2.0D and 2.5D, and that the critical pressure ratio increases with the curvature radius.

  • PDF

방전 침전극의 곡률반경이 이온풍 발생에 미치는 영향 (Effect of Radius of Curvature of a Corona Needle on Ionic Wind Generation)

  • 황덕현;문재덕
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.604-608
    • /
    • 2010
  • An electric fan for cooling high density electronic devices is limited and operated in very low efficiency. The corona discharge is utilized as the driving mechanism for an ionic gas pump, which allows for air flow control and generation with low noise and no moving parts. These ideal characteristics of ionic pump give rise to variety applications. However, all of these applications would benefit from maximizing the flow velocities and yields of the ionic pump. In this study, a needle-mesh type ionic pump has been investigated by focusing on the radius of curvature of corona needle points elevating the ionic wind velocity and efficiency. It is found that the radius of curvature of the corona discharge needle point influences significantly to produce the ionic wind and efficiency. As a result, an elevated ionic wind velocity and increased ionic wind generation yield can be obtained by optimized the radius of curvature of the corona needle electrode.

종동절의 상대가속도를 이용한 원반 캠의 곡률반경 결정법에 관한 연구 (A Study on Curvature Determination Approach of Disk Cams Using relative Accelerations of Followers)

  • 신중호;강동우;김종수;김대원
    • 한국정밀공학회지
    • /
    • 제17권8호
    • /
    • pp.113-119
    • /
    • 2000
  • There are two major factors which affect the cam design : the pressure angle and the radius of curvature, Cam shape will have an instantaneous radius of curvature at every point. Even though the design constraint of the pressure angle has been satisfied the follower may still not complete the desired contact motion. If the radius of the follower roller is larger than the concave(negative) radius on the cam it occurs the gap between the cam and the follower roller at the contact point. And also if the curvature of the pitch curve of the cam is too sharp the cam profile may be undercut. This paper proposes a new approach which uses the relative velocity of the follower roller parallel to the tangent line at the contact point on the cam surface for determining the pressure angle and the relative acceeration for determining the radius of curvature.

  • PDF

환형 관내의 데토네이션 파 전파 특성 해석 (Numerical Analysis of Detonation Wave Propagation Characteristics in Annular Channels)

  • 이수한;조덕래;최정열
    • 한국추진공학회지
    • /
    • 제12권2호
    • /
    • pp.66-73
    • /
    • 2008
  • 본 논문에서는 환형 관에서의 데토네이션 파의 전파 특성을 살펴보았다. 이전의 연구에 이용된 수치 기법과 이동 계산 창 기법을 본 연구에 이용하였으며, 관 폭의 값으로 무차원화 된 곡률 반경을 유일한 기하학적 변수로 고려하여 일련의 해석을 수행하였다. 곡률 반경이 작은 환형 관에서 데토네이션 파는 불안정하여 정규적인 데토네이션 셀 구조가 나타나지 않으며 셀 구조가 유지될 수 있는 임계 곡률 반경이 존재함을 알 수 있었다. 곡률의 효과로 관의 내벽 및 외벽은 압력 차가 발생하며, 외벽 쪽에 서는 overdriven 데토네이션의 경향을 가진다. 예상할 수 있는 바와 같이 곡률 반경이 커지면서 직선관의 결과에 수렴한다.

레이저 간섭계를 이용한 곡률반경 측정에 관한 연구 (A study on measurement of curvature radius by the using of laser Interferometer)

  • 김수용;이승수;박재덕;송영철;전언찬
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.920-924
    • /
    • 2003
  • This paper on measurement of curvature radius by the using of laser interferometer and prove. Mean value compared of ball and bearing It is developed program for date creation, and the verification using program. Measurement object center and curvature radius taking of LSC. when it is compared bearing prove with ball prove, the bearing prove can not proper by reason of big uncertainty and If laser setting error decrease, curvature radius get precision radius 10$\^$-5/.

  • PDF

RGP 렌즈 착용한 대학생의 각막곡률반경 측정 (Study in Radius of Corneal Curvature of university Students with Keratometer)

  • 김창식;류광민
    • 한국안광학회지
    • /
    • 제11권3호
    • /
    • pp.181-185
    • /
    • 2006
  • 각막곡률반경은 RGP 렌즈를 착용한 대학생(1980~1984년)을 대상으로 측정하였다. 대상자는 187명으로 여자(167), 남자(17) 그리고 원추각막환자(3)이었다. 각막곡률반경은 전체대상자의 평균치가 7.77mm이었고, 좌안과 우안의 측정치 역시 7.77mm이었다. 눈의 수평, 수직경선의 측정치는 7.88mm, 7.65mm이었다. 남자와 여자의 경우는 모두가 수평이 수직경선보다 동일하게 0.22mm 크게 조사되었다. 성별에 따른 곡률반경의 차이는 남자의 경우 평균치가 7.84mm으로 여자의 경우보다 0.08mm 정도 크게 측정되었고, 좌, 우안의 크기는 차이가 없었다. 원추각막환자는 곡률반경의 평균치가 6.86mm으로 정상인 조사대상자의 평균치보다 0.91mm 작게 조사되어 차이가 큰 것으로 나타났다.

  • PDF

CF/Epoxy 복합재 적층쉘의 충격특성 (Impact Characteristics on the Laminated Shell for CF/Epoxy Composite)

  • 양현수;정풍기;김영남;이종선
    • 대한안전경영과학회지
    • /
    • 제6권1호
    • /
    • pp.311-323
    • /
    • 2004
  • This paper is to study the energy absorption characteristics of CF/Epoxy(Carbon Fiber/Epoxy Resin) laminated shell with the various curvatures subjected to transverse impact loadings under the low impact velocity in consideration of design of structural members for use of transportation machine, which are consisted of the characteristics of high stiffness, strength and lightweight. The curvature radius are associated with the energy absorption characteristics of CF/Epoxy laminated shell which is brittleness material. In all tests, maximum load of CF/Epoxy laminated plate is higher than that of laminated shell with curvature, but maximum deflection is lower. And then absorbed energy of laminated shell with curvature is higher than laminated plate(curvature radius is unlimited), As curvature radius is increased, the absorbed energy is increased in laminated shell with curvature.