• Title/Summary/Keyword: Current transient

Search Result 1,271, Processing Time 0.029 seconds

Vector Controlled Induction Motor Drives Fed by PWM CSI Using Space Current Vectors (공간 전류벡터를 이용한 PWM CSI 구동 유도전동기의 벡터제어)

  • Lee, Dong-Choon;Ko, Sung-Beom;Ro, Chae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.357-359
    • /
    • 1995
  • In this paper, vector control of induction motor drives using space current vector PWM is presented. The scheme gives advantages, besides robustness to inverter arm-shoot, sinusoidal input current and voltage for induction motors. In addition, space vector PWM for CSI produces faster transient response than conventional pattern PWM. Also, a modulation index control is proposed.

  • PDF

DTV Lip-Sync Test Using Embedded Audio-Video Time Indexed Signals (숨겨진 오디오 비디오 시간 인덱스 신호를 사용한 DTV 립싱크 테스트)

  • 한찬호;송규익
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.3
    • /
    • pp.155-162
    • /
    • 2004
  • This paper concentrated on lip synchronization (lip sync) test for DTV with respect to audio and video signals using a finite digital bitstream In this paper, we propose a new lip sync test method which does not effect on the current program by use of the transient effect area test signals (TATS) and audio-video time index lip sync test signals (TILS).the experimental result shows that the time difference between audio and video signal can be easily measured by captured oscilloscope waveform at any time.

Transient Torque Maximizing Strantegy of Induction Machine in Field Weakening Region (약계자 영역에서의 유도전동기 과도 토오크 최대화 기법)

  • 송승호;최종우;설승기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.474-482
    • /
    • 1999
  • In this paper, a new field weakening algorithm which maximizes the output torque not only in steady state b but also in transient state is proposed. Considering both voltage and current limit of system, analytic solutions f for optimal torque utilization in field weakening region I and region II are obtained. This algorithm finds optimal currents considering dynamic vol떠ge limit based on flux and speed. So the maximum usage of stator v voltage even in transient state results in the maximum torque and fast response time. Simulation and e experimental results show the effectiveness of the proposed field weakening scheme.

  • PDF

New Control Method of Converter to Improve Transient Response in HVDC Link System (직류송전에서 과도응답특성 개선을 위한 컨버터의 제어)

  • Min, Wan-Ki;Yoo, Myeong-Ho;Kim, Yeong-Han;Choi, Jeo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.342-344
    • /
    • 1996
  • This paper describes the usefulness of new control method in HVDC link system which suffers from severe condition of weak ac system. The proposed control scheme is used for the positive feedback control which directly controlls dc current at dc link system. The object of this paper is to improve the transient response of HVDC link system in disturbances such as faults. To achieve this objective, digital time-domain simulations are employed by the Electro Magnetic Transient Program for DC system(EMTDC).

  • PDF

CFD and surrogates-based inducer optimization

  • Kratky, Tomas;Zavadil, Lukas;Doubrava, Vit
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.213-221
    • /
    • 2016
  • Due to the nature of cavitation numerical analyses, computational optimization of a pump with respect to the cavitation properties is extremely demanding. In this paper it is shown how a combination of Transient Blade Row (TBR) method and some simplifications can be used for making the optimization process more efficient and thus possible on current generation of hardware. The aim of the paper is not the theory of hydraulic design. Instead, the practical aspects of numerical optimization are shown. This is done on an example of a radial pump and a combination of ANSYS CFX, ANSYS software tools and custom scripts is used. First, a comparison of TBR and fully-transient simulation is made. Based on the results, the TBR method is chosen and a parametric model assembled. Design of Experiment (DOE) table is computed and the results are used for sensitivity analysis. As the last step, the final design is created and computed as fully-transient. In conclusion, the results are discussed.

Simultaneous Estimation of the Speed and the Secondary Resistance under the Transient State of Induction Motor

  • Akatsu, Kan;Kawamura, Atsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.298-303
    • /
    • 1998
  • In the speed sensorless control of the induction motor, the machine parameters (especially the secondary resistance R2) have a strong influence to the speed estimation. It is known that the simultaneous estimation of the speed and R2 is impossible in the slip frequency type vector control, because the secondary flux is constant. But the secondary flux is not always constant in the speed transient state. In this paper the R2 estimation in the transient state without adding any additional signal to the stator current is proposed. This algorithm uses the least mean square algorithm and the adaptive algorithm, and it is possible to estimate the R2 exactly. This algorithm is verified by the digital simulations and the experiments.

  • PDF

High Performance Drives of Induction Motor with On-Line Tuning of Stator Transient Inductance in Field Weakening Region

  • Kim, Ha-Yong;Shin, Myoung-Ho;Hyun, Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.17-22
    • /
    • 1998
  • Stator Transient inductance has much influence on rotor flux orientation. In this paper, a new simple on-line tuning scheme of inductances including stator transient inductance for rotor flux orientation control is proposed. Detuned effects caused by inductance variations are shown and simple on-line tuning scheme of them is proposed. Inductances are estimated and tuned by only stator flux and stator current. The proposed scheme is effective in wide speed region including the field weakening region. The proposed on-line tuning scheme is confirmed by the simulation and experiment results.

  • PDF

An Enhanced Zone 3 Algorithm of a Distance Relay using Transient Components and State Diagram (과도성분과 상태도를 이용한 거리 계전기의 향상된 Zone 3 알고리즘)

  • 허정용;김철환
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.161-167
    • /
    • 2004
  • Zone 3 of the distance relay is used to provide the remote back-up protection in case of the failure of the primary protection. However, the risk lot mal-operations under stressed conditions such as heavy loading, voltage and transient instability is usually high. Zone 3 is used in combination with the derivatives of the voltage, and current, etc to prevent mal-operations. Sometimes, the impedance characteristics that restrict the tripping area of relay are used to avoid the mal-operations due to load encroachment. This paper presents a novel Zone 3 scheme based on combining the steady-state components (i.e. 60Hz) and the transient components (TCs) using a state diagram that visualizes the sequence of studies that emanate from the sequence of events. The simulation results show that the novel zone 3 distance relay elements using the proposed method operates correctly for the various events.

An analysis of transient state for induction motor by using the magnetic equivalent circuit method (자기등가회로법에 의한 유도전동기 과도상태해석)

  • Jeong, Jong-Ho;Lee, Eun-Woong;Cho, Hyun-Kil;Kim, Jun-Ho;Lee, Hwa-Su
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.18-20
    • /
    • 2002
  • In this paper, the construction elements of the induction motor was represented by the magnetic tube. The magnetic tube is basis of the magnetic equivalent circuit. The magnetic equivalent circuit method is convenient of complicated analysis of the transient state of the induction motor. Because the method is restriction on only one direction of magnetic flux. Air gap magnetomotive force was calculated by magnetic equivalent circuit method. Starting transient torque and phase current of the induction motor was confirmed by the theoretical calculation and the experiments.

  • PDF

Study on the Transient Phenomenon Simulation of Wind Power Generation System using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 풍력발전시스템의 과도현상 시뮬레이션에 관한 연구)

  • Han, Sang-Geun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.309-312
    • /
    • 2002
  • For the purpose of more effective simulation of the utility interactive WPGS(Wind Power Generation System) the SWRW (Simulation method for WPGS using Real Weather condition) is used in this paper, in which those of three topics for the WPGS simulation. user-friendly method, applicability to grid-connection and the utilization of the real weather conditions, are satisfied. The simulation of the WPGS using the real weather condition including components modeling of wind turbine system is achieved by introducing the interface method of a non-linear external parameter and FORTRAN using PSCAD/EMTDC. The simulations of steady-state and transient-state are performed effectively by the introduced simulation method. The generator output and current supplied into utility can be obtained by the steady-state simulation, and THD can be achieved by analyzing the results as well. The transient - state of the WPGS can be analyzed by the simulation results of over cut-out wind speed.

  • PDF