• Title/Summary/Keyword: Current transient

Search Result 1,271, Processing Time 0.031 seconds

Overexpression of Heat Shock Factor Gene HsfA3 Increases Galactinol Levels and Oxidative Stress Tolerance in Arabidopsis

  • Song, Chieun;Chung, Woo Sik;Lim, Chae Oh
    • Molecules and Cells
    • /
    • v.39 no.6
    • /
    • pp.477-483
    • /
    • 2016
  • Heat shock factors (Hsfs) are central regulators of abiotic stress responses, especially heat stress responses, in plants. In the current study, we characterized the activity of the Hsf gene HsfA3 in Arabidopsis under oxidative stress conditions. HsfA3 transcription in seedlings was induced by reactive oxygen species (ROS), exogenous hydrogen peroxide ($H_2O_2$), and an endogenous $H_2O_2$ propagator, 2,5-dibromo-3-methyl-6-isopropyl-p-benzoquinone (DBMIB). HsfA3-overexpressing transgenic plants exhibited increased oxidative stress tolerance compared to untransformed wild-type plants (WT), as revealed by changes in fresh weight, chlorophyll fluorescence, and ion leakage under light conditions. The expression of several genes encoding galactinol synthase (GolS), a key enzyme in the biosynthesis of raffinose family oligosaccharides (RFOs), which function as antioxidants in plant cells, was induced in HsfA3 overexpressors. In addition, galactinol levels were higher in HsfA3 overexpressors than in WT under unstressed conditions. In transient transactivation assays using Arabidopsis leaf protoplasts, HsfA3 activated the transcription of a reporter gene driven by the GolS1 or GolS2 promoter. Electrophoretic mobility shift assays showed that GolS1 and GolS2 are directly regulated by HsfA3. Taken together, these findings provide evidence that GolS1 and GolS2 are directly regulated by HsfA3 and that GolS enzymes play an important role in improving oxidative stress tolerance by increasing galactinol biosynthesis in Arabidopsis.

Design of Self-Starting Hybrid Axial Flux Permanent Magnet Synchronous Motor Connected Directly to Line

  • Eker, Mustafa;Akar, Mehmet;Emeksiz, Cem;Dogan, Zafer;Fenercioglu, Ahmet
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1917-1926
    • /
    • 2018
  • In view of the current state of the reserves of electric energy generated resources and the share of electric motors in electricity consumption, many researches and studies related to efficiency in electric motors are being made. The presented work is related to the Axial Flux Permanent Magnet Synchronous Motor (AF-PMSM), which has recently undergone significant work based on the development of magnet and motor technology. In this study, a novel AF-PMSM was designed analytically through Finite Element Method (FEM) which can be started by connecting to a line such as an asynchronous motor in a transient state and can operate with high efficiency and power factor after synchronization in steady state without the need for an expensive motor drive. According to the obtained FEM results, a design with an efficiency class of IE4 of 5.5 kW shaft power, a 4 poles motor was obtained. As a result, economic calculations indicate that the extra cost of the designed Line start AF-PMSM with respect to the asynchronous motor is rapidly compensated by energy saving due to a more efficient operation, especially constant speed operations. As a result of the analysis obtained, the targeted values are reached. For induction motors and radial flux permanent magnet synchronous motors, a good alternative motor that can operate with high efficiency and power factor has been obtained.

Modeling and Direct Power Control Method of Vienna Rectifiers Using the Sliding Mode Control Approach

  • Ma, Hui;Xie, Yunxiang;Sun, Biaoguang;Mo, Lingjun
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.190-201
    • /
    • 2015
  • This paper uses the switching function approach to present a simple state model of the Vienna-type rectifier. The approach introduces the relationship between the DC-link neutral point voltage and the AC side phase currents. A novel direct power control (DPC) strategy, which is based on the sliding mode control (SMC) for Vienna I rectifiers, is developed using the proposed power model in the stationary ${\alpha}-{\beta}$ reference frames. The SMC-based DPC methodology directly regulates instantaneous active and reactive powers without transforming to a synchronous rotating coordinate reference frame or a tracking phase angle of grid voltage. Moreover, the required rectifier control voltages are directly calculated by utilizing the non-linear SMC scheme. Theoretically, active and reactive power flows are controlled without ripple or cross coupling. Furthermore, the fixed-switching frequency is obtained by employing the simplified space vector modulation (SVM). SVM solves the complicated designing problem of the AC harmonic filter. The simplified SVM is based on the simplification of the space vector diagram of a three-level converter into that of a two-level converter. The dwelling time calculation and switching sequence selection are easily implemented like those in the conventional two-level rectifier. Replacing the current control loops with power control loops simplifies the system design and enhances the transient performance. The simulation models in MATLAB/Simulink and the digital signal processor-controlled 1.5 kW Vienna-type rectifier are used to verify the fast responses and robustness of the proposed control scheme.

Modified Direct Torque Control using Algorithm Control of Stator Flux Estimation and Space Vector Modulation Based on Fuzzy Logic Control for Achieving High Performance from Induction Motors

  • Rashag, Hassan Farhan;Koh, S.P.;Abdalla, Ahmed N.;Tan, Nadia M.L.;Chong, K.H.
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.369-380
    • /
    • 2013
  • Direct torque control based on space vector modulation (SVM-DTC) protects the DTC transient merits. Furthermore, it creates better quality steady-state performance in a wide speed range. The modified method of DTC using SVM improves the electrical magnitudes of asynchronous machines, such as minimizing the stator current distortions, the stator flux with electromagnetic torque without ripple, the fast response of the rotor speed, and the constant switching frequency. In this paper, the proposed method is based on two new control strategies for direct torque control with space vector modulation. First, fuzzy logic control is used instead of the PI torque and a PI flux controller to minimizing the torque error and to achieve a constant switching frequency. The voltages in the direct and quadratic reference frame ($V_d$, $V_q$) are achieved by fuzzy logic control. In this scheme, the switching capability of the inverter is fully utilized, which improves the system performance. Second, the close loop of stator flux estimation based on the voltage model and a low pass filter is used to counteract the drawbacks in the open loop of the stator flux such as the problems saturation and dc drift. The response of this new control strategy is compared with DTC-SVM. The experimental and simulation results demonstrate that the proposed control topology outperforms the conventional DTC-SVM in terms of system robustness and eliminating the bad outcome of dc-offset.

New On-Chip RF BIST(Built-In Self Test) Scheme and Circuit Design for Defect Detection of RF Front End (RF Front End의 결함 검출을 위한 새로운 온 칩 RF BIST 구조 및 회로 설계)

  • 류지열;노석호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.449-455
    • /
    • 2004
  • This paper presents a novel defect detection method for one chip RF front end with fault detection circuits using input matching measurement. We present a BIST circuit using 40.25{\mu}m$ CMOS technology. We monitor the input transient voltage of the RF front end to differentiate faulty and fault-free RF front end. Catastrophic as well as parametric variation fault models are used to simulate the faulty response of the RF front end. This technique has several advantages with respect to the standard approach based on current test stimulus and frequency domain measurement. Because DUT and fault detection circuits are implemented in the same chip, this test technique only requires use of digital voltmeter (RMS meter) and RF voltage source generator for simpleand inexpensive testing.

Development and Application of Operation Methods of Battery Energy Storage System for Frequency Regulation (주파수조정용 배터리 에너지저장장치 운전방법의 개발과 적용)

  • Lim, Geon-Pyo;Park, Doo-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.57-61
    • /
    • 2015
  • Current research and development efforts and other projects for energy storage systems (ESS) have recently been gaining attention. This is due to the many applications where ESS, particularly batteries, can be used. Among these are peak shaving, frequency regulation, and stabilization of renewable energy output. KEPCO has completed the construction and demonstration of a 4-MW battery energy storage system (BESS) located in Jeju City to verify its practicability in the power grid. KEPCO Research Institute has also been developing technology for the commercialization of BESS, and has been conducting a trial run of a 52-MW ESS (28MW + 24MW of Seo-Anseong and Shin-Yongin substations) constructed in 2014 for frequency regulation. This paper discusses the development of operation methods, as well as an operation user interface, for the safe operation and monitoring of BESS used for frequency regulation in a power system. Included are operation and simulation methods for various normal and transient frequency situations that can be experienced by a power system. Also discussed are the results obtained after applying these methods to the 4-MW BESS and the 52-MW ESS, both used for frequency regulation. The technology in this paper will be applied to 500MW ESS for frequency regulation of KEPCO by 2017. It is expected that this technology helps a safe and reliable operation and control of ESS for frequency regulation through its continuous upgrade.

Regulation of Transient Receptor Potential Melastatin 7 (TRPM7) Currents by Mitochondria

  • Kim, Byung Joo;Jeon, Ju-Hong;Kim, Seon Jeong;So, Insuk;Kim, Ki Whan
    • Molecules and Cells
    • /
    • v.23 no.3
    • /
    • pp.363-369
    • /
    • 2007
  • Mitochondria play a central role in energy-generating processes and may be involved in the regulation of channels and receptors. Here we investigated TRPM7, an ion channel and functional kinase, and its regulation by mitochondria. Proton ionophores such as CCCP elicited a rapid decrease in outward TRPM7 whole-cell currents but a slight increase in inward currents with pipette solutions containing no MgATP. With pipette solutions containing 3 mM MgATP, however, CCCP increased both outward and inward TRPM7 currents. This effect was reproducible and fully reversible, and repeated application of CCCP yielded similar decreases in current amplitude. Oligomycin, an inhibitor of $F_1/F_O$-ATP synthase, inhibited outward whole-cell currents but did not affect inward currents. The respiratory chain complex I inhibitor, rotenone, and complex III inhibitor, antimycin A, were without effect as were kaempferol, an activator of the mitochondrial $Ca^{2+}$ uniporter, and ruthenium red, an inhibitor of the mitochondrial $Ca^{2+}$ uniporter. These results suggest that the inner membrane potential (as regulated by proton ionophores) and the $F_1/F_O$-ATP synthase of mitochondria are important in regulating TRPM7 channels.

New trends of root canal disinfection and treatment strategies for infected root canal based upon evidence-based dentistry

  • Cho, Yong-Bum
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.608-608
    • /
    • 2003
  • The main objectives of root canal therapy are cleaning and shaping and then obturating the root canal system in 3 dimensions to prevent reinfection. Many instrumentation techniques and devices, supported by an irrigation system capable of removing pulp tissue remnants and dentin debris, have been proposed to shape root canals. But current regimens in chemomechanical debridement using instrumentation and irrigation with NaOCl are not predictably effective in root canal disinfection. These findings are not surprising because the root canal system is complex and contains numerous ramifications and anatomical irregularities. The microorganisms in root canals not only invade the anatomic irregularities of the root canal system but also are present in the dentinal tubules. Therefore further disinfection with an effective antimicrobial agent may be necessary and it well1mown that use of intracanal medication will lower bacterial count in infected root canals. Calcium hydroxide has a long history of use in endodontics, and more attention has been given to the use of calcium hydroxide as intracanal dressing for the treatment of infected pulp. However, when treatment is completed in one visit, no intracanal medications other than intracanal irrigants are used. Recently, a mixture of a tetracycline isomer, an acid, and a detergent(MTAD), has been introduced as a final rinse for disinfuction of the root canal system. It has been shown that MTAD is able to remove the smear layer with minimal erosive changes on the surface of dentin, and is effective against Enterococcus faecalis, a microorganism resistant to the action of other antimicrobial medications. In another study, the ability of MTAD was investigated to disinfect contaminated root canals with whole saliva and compared its efficacy to that of NaOCl Based on the results, it seems that MTAD is significantly more effective than 5.25% NaOCl in eradicating bacteria from infected root canals. In the cytotoxicity evaluation, MTAD is less cytotoxic than engenol, 3% $H20_2,\;Ca(OH)_2$ paste, 5.25% NaGCl, Peridex, and EDTA and more cytotoxic than 2.63%,1.31% and 0.66% NaOCl. Is it promising or transient?

  • PDF

Speed Controller Transition Method for I-F Operation and Sensorless Operation of Permanent Magnet Synchronous Motor (영구자석 동기 전동기의 I-F 구동과 센서리스 구동을 위한 속도 제어 절환 기법)

  • Kim, Dong-Uk;Kim, Sungmin
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.543-551
    • /
    • 2019
  • Permanent Magnet Synchronous Motors(PMSMs) have a wider range of applications due to their high output density and high efficiency. PMSMs are used not only in high-power density, high-performance motor-driven systems such as vehicle and robots, but also in systems where cost-cutting is very important, such as washing machines, air conditioners and refrigerators. To reduce costs, position sensorless control is required, which is generally difficult to be used under conditions of starting the motor. Thus, the I-F speed control that rotates the current vector at any speed in the starting procedure should be used at first, and then the sensorless speed control could be applied after PMSM rotates above a certain speed. Speed control performance in I-F speed control and sensorless speed control is very important. And more speed control performance should be maintained even in the transient in which the two control techniques are changed. In this paper, the speed controller transition method from I-F speed control to sensorless speed control of permanent magnet synchronous motor is proposed. Experiments were carried out on the washing machine drive system to verify the performance of the proposed technique.

Seroprevalence of Plasmodium vivax Circumsporozoite Protein Antibody in High-Risk Malaria Areas in Korea

  • Lee, Jinyoung;Jin, Kyoung;Ahn, Seong Kyu;Lee, Sung-Keun;Kwon, Hyung Wook;Na, Byoung-Kuk;Kim, Tong-Soo
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.4
    • /
    • pp.415-419
    • /
    • 2021
  • The circumsporozoite protein (CSP) of Plasmodium spp. is a diagnostic antigen and useful biomarker for monitoring short-term/seasonal changes to malaria transmission. Using P. vivax CSP antibody ELISA, epidemiological characteristics were analyzed in the residents of Ganghwa, Cheorwon, Paju, and Goseong from 2017 to 2018. In Ganghwa and Cheorwon, 1.6% and 1.2% of residents, respectively, were PvCSP-antibody-positive in 2018, which indicates a decrease of 0.4% in the positive rate compared to 2017. The annual parasite incidence (API) in Ganghwa and Cheorwon was 24.9 and 10.5 in 2017 and 20.3 and 10.7 in 2018, respectively. Although the changes were not significant, the API in Ganghwa decreased slightly by 4.5 in 2018 compared to the previous year. In Paju and Goseong, 3.9% and 2.0% of residents were positive for the PvCSP antibody. The API in Paju was 13.1 in 2017 and 16.0 in 2018, although no malaria patients were reported for the 2 years. Therefore, the results suggest that PvCSP is a useful antigen for confirming initial malaria infection. Additionally, considering that the antibody is relatively transient, it can be employed for sero-epidemiological studies to determine the extent of malaria transmission in the current year.