• Title/Summary/Keyword: Current transient

Search Result 1,272, Processing Time 0.031 seconds

Electrical properties of a resistive SFCL with shunt resistor (분로저항을 가진 저항형 초전도 한류기의 전기적 특성)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Hye-Rim;Hwang, Si-Dole;Kim, Sang-Joon
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.343-347
    • /
    • 1999
  • We fabricated a resistive SFCL having a shunt resistor parallel to it in order to bifurcate the transient current at faults. The SFCL consists of a YBCO film coated with an Au layer (10 ${\omega}$ at room temperature), which is to disperse the heat generated at hot spots in the YBCO film, and the 5 ${\omega}$ shunt resistor. The minimum quench current of the SFCL was found to be 12.2 A$_{peak}$. This SFCL successfully controlled the fault current below 23 A$_{peak}$ which is otherwise to increase up to 113 A$_{peak}$. Bifurcation of the current resulted in the temperature rise of the YBCO/Au film 3 times slower than without the shunt, protecting the SFCL at high currents.

  • PDF

Characterization of Voltage-Gated Potassium Currents in Dorsal Root Ganglion Neurons of Neonatal Rats (신생흰쥐 척수후근신경절 세포에서 전압의존성 $K^+$ 전류의 동정)

  • Kim, Ji-Mok;Jung, Sung-Jun;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.1 no.6
    • /
    • pp.613-624
    • /
    • 1997
  • Dorsal root ganglion (DRG) is composed of neuronal cell bodies of primary afferents with diverse functions. Various types of ion channels present on DRG neurons may reflect those functions. In the present study, voltage-gated potassium currents in DRG neurons of neonatal rats were characterized by whole-cell voltage clamp method. Two types of delayed rectifier and three types of transient potassium currents were identified according to their electrophysiological properties. The delayed rectifier currents were named $I_{Ke}$ (early inactivating) and $I_{K1}$ (late inactivating). Steady state inactivation of $I_{Ke}$ began from -100 mV lasting until -20 mV. $I_{K1}$ could be distinguished from $I_{Ke}$ by its inactivation voltage range, from -70 mV to +10 mV. Three transient currents were named $I_{Af}$ (fast inactivation), $I_{Ai}$ (intermediate inactivation kinetics), and $I_{As}$ (slow inactivation). $I_{Af}$ showed fast inactivation with time constant of $10.6{\pm}2.0$ msec, $I_{Ai}$ of $36.9{\pm}13.9$ msec, and $I_{As}$ of $60.6{\pm}2.9$ msec at +30 mV, respectively. They also had distinct steady state inactivation range of each. Each cell expressed diverse combination of potassium currents. The cells most frequently observed were those which expressed both $I_{K1}$ and $I_{Af}$, and they had large diameters. The cells expressing $I_{Ke}$ and expressing $I_{Ke}$, $I_{Ai}$, and $I_{As}$ usually had small diameters. Judging from cell diameter, capsaicin sensitivity or action potential duration, candidates for nociceptor were the cells expressing $I_{Ke}$, expressing $I_{Ke}$ and $I_{Ai}$, and expressing $I_{Ke}$ and $I_{As}$. The types and distribution of potassium currents in neonatal rat DRG were similar to those of adult rat DRG (Gold et al, 1996b).

  • PDF

Circuit Modeling and Simulation of Active Controlled Field Emitter Array for Display Application (디스플레이 응용을 위한 능동 제어형 전계 에미터 어레이의 회로 모델링 및 시뮬레이션)

  • Lee, Yun-Gyeong;Song, Yun-Ho;Yu, Hyeong-Jun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.2
    • /
    • pp.114-121
    • /
    • 2001
  • A circuit model for active-controlled field emitter array(ACFEA) as an electron source of active-controlled field emission display(ACFED) has been proposed. The ACFEA with hydrogenated amorphous silicon thin-film transistor(a-Si:H TFT) and Spindt-type molibdenum tips (Spindt-Mo FEA) has been fabricated monolithically on the same glass. A-Si:H TFT is used as a control device of field emitters, resulting in stabilizing emission current and lowering driving voltage. The basic model parameters extracted from the electrical characteristics of the fabricated a-Si:H TFT and Spindt-Mo FEA were implemented into the ACFEA model with a circuit simulator SPICE. The accuracy of the equivalent circuit model was verified by comparing the simulated results with the measured one through DC analysis of the ACFEA. The transient analysis of the ACFEA showed that the gate capacitance of FEA along with the drivability of TFT strongly affected the response time. With the fabricated ACFEA, we obtained a response time of 15$mutextrm{s}$, which was enough to make 4bit/color gray scale with the pulse width modulation (PWM).

  • PDF

Heat-up Calculation for the Auxiliary Feed Water Pump Room at Ulchin Units 3 and 4 for Loss of HVAC Accidents (HVAC 상실사고시 울진원전 3/4 호기의 보조급수펌프 격실 온동상승 평가)

  • Yoon, Churl;Park, Jin-Hee;Hwang, Mee-Jeong;Han, Sang-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.5
    • /
    • pp.553-562
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) analysis has been performed to estimate the air temperature inside an Auxiliary Feed Water (AFW) Motor-Driven (MD) pump room for the case where there is loss of Heating, Ventilation, and Air-Conditioning (HVAC). A transient calculation for the closed pump room without cooling by any HVAC system shows that the volume-averaged air temperature reaches around $60^{\circ}C$ for a transient period of 8.0 h. From previous studies, the external air and surface boundary temperatures are assumed to increase slowly starting from an initial temperature of $35^{\circ}C$. For the cases where the door is opened at 2, 4, and 6 h after the initiation of HVAC failure, the average air temperature promptly drops by about $4^{\circ}C$ when the door is opened and then slowly increases. The current calculations based on the CFD technique predict the rate of increase of air temperature to be lower than that determined by previous conservative calculations on the basis of a lumped model.

Design and Thermal Analysis of Focal Plane Assembly Cooling Unit of Earth Observation Camera (저궤도 지구관측위성 주탑재체 냉각유닛 설계와 열해석)

  • Seo, Joung-Ki;Cho, Hee-Ken;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin;Kang, Seok-Bong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.580-585
    • /
    • 2009
  • Thermal analysis and design of FPA(Focal Plane Assembly)-CU(Cooling Unit) for Earth observation camera is performed. FPA-CU is the first cooling device for a spacecraft which is designed and manufactured by its own technology in Korea. FPA-CU has a special feature, TBM(Thermal Buffer Mass) which is discriminated from typical cooling devices using heat pipes and radiator. TBM can be regarded as a thermal energy reservoir and it shows thermally transient characteristics, which make it difficult to design the size and shape of TBM. In current study, a method to determine the volume and the size of TBM is proposed and validated. The transient thermal analysis for FPA-CU for 5 operational scenarios is performed and validates the final design of FPA-CU (Radiator,TBM, Heat pipe I/F). In case of an abnormal operation of a heat pipe among three radiator heat pipes, the temperature of FPA can be increased $3{\sim}4^{\circ}C$ according to the numerical simulation.

Development of Wireless Smart Sensing Framework for Structural Health Monitoring of High-speed Railway Bridges (고속 철도 교량의 구조 건전성 모니터링을 위한 스마트 무선 센서 프레임워크 개발)

  • Kim, Eunju;Park, Jong-Woong;Sim, Sung-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.1-9
    • /
    • 2016
  • Railroad bridges account for 25% of the entire high-speed rail network. Railway bridges are subject to gradual structural degradation or fatigue accumulation due to consistent and repeating excitation by fast moving trains. Wireless sensing technology has opened up a new avenue for bridge health monitoring owing to its low-cost, high fidelity, and multiple sensing capability. On the other hand, measuring the transient response during train passage is quite challenging that the current wireless sensor system cannot be applied due to the intrinsic time delay of the sensor network. Therefore, this paper presents a framework for monitoring such transient responses with wireless sensing systems using 1) real-time excessive vibration monitoring through ultra-low-power MEMS accelerometers, and 2) post-event time synchronization scheme. The ultra-low power accelerometer continuously monitors the vibration and trigger network when excessive vibrations are detected. The entire network of wireless smart sensors starts sensing through triggering and the post-event time synchronization is conducted to compensate for the time error on the measured responses. The results of this study highlight the potential of detecting the impact load and triggering the entire network, as well as the effectiveness of the post-event time synchronized scheme for compensating for the time error. A numerical and experimental study was carried out to validate the proposed sensing hardware and time synchronization method.

Transient Overloads Control Mechanism for Virtual Memory System (가상 메모리 시스템의 일시적인 과부하 완화 기법)

  • Go, Young-Woong;Lee, Jae-Yong;Hong, Cheol-Ho;Yu, Hyukc
    • The KIPS Transactions:PartA
    • /
    • v.8A no.4
    • /
    • pp.319-330
    • /
    • 2001
  • In virtual memory system, when a process attempts to access a page that is not resident in memory, the system generates and handles a page fault that causes unpredictable delay. So virtual memory system is not appropriate for the real-time system, because it can increase the deadline miss ratio of real-time task. In multimedia system, virtual memory system may degrade the QoS(quality of service) of multimedia application. Furthermore, in general-purpose operating system, whenever a new task is dynamically loaded, virtual memory system suffers from extensive page fault that cause transient overloading state. In this paper, we present efficient overloading control mechanism called RBPFH (Rate-Based Page Fault Handling). A significant feature of the RBPFH algorithm is page fault dispersion that keeps page fault ratio from exceeding available bound by monitoring current system resources. Furthermore, whenever the amount of available system resource is changed, the RBPFH algorithm dynamically adjusts the page fault handling rate. The RBPFH algorithm is implemented in the Linux operating system and its performance measured. The results demonstrate RBPFH\`s superior performance in supporting multimedia applications. Experiment result shows that RBPFH could achieve 10%∼20% reduction in deadline miss ratio and 50%∼60% reduction in average delay.

  • PDF

Effects of Transcranial Direct-Current Stimulation Therapy on Primary Chronic Insomnia: A Proof-of Concept Clinical Trial (일차성 만성불면증 환자에서 경두개 직류전기자극법 치료 효과: 개념 증명 연구)

  • Jun, Jin-Sun;Kim, Tae-Joon;Koo, Sun A;Park, Ji-Sook;Kim, Keun Tae;Yang, Tae-Won;Lim, Jung-Ah;Byun, Jung-Ick;Sunwoo, Jun-Sang;Jung, Ki-Young
    • Journal of Sleep Medicine
    • /
    • v.15 no.2
    • /
    • pp.37-42
    • /
    • 2018
  • Objectives: To assess the effect and safety of transcranial direct-current stimulation (tDCS) in primary chronic insomnia. Methods: A one-month, double-blind, randomized, sham-controlled trial was performed. A total of 7 patients with primary chronic insomnia received tDCS using anodal (n=3), cathodal (n=2), or sham stimulation (n=2). They were followed up at 1 week and 1 month after treatment. The primary outcome measures included improvement in total sleep time (TST), sleep latency (SL), and sleep efficiency (SE) at 1 month follow-up. Results: TST and SE were improved with tDCS at 1 month follow-up in all patients (100%) of the anodal group, one (50%) of the cathodal group, and one (50%) of the sham group. tDCS improved SL at 1 month follow-up in two patients (67%) of the anodal group, one (50%) of the cathodal group, and none (0%) of the sham group. With respect to adverse events, transient itching sensation occurred in one patient of the anodal group. None of the other groups reported adverse events. Conclusions: Our results suggest that tDCS may be effective and safe for treatment of primary chronic insomnia. A larger controlled study needs to be further investigated.

Clinical study on C.V.A patients in Hospital attached to college of oriental medicine and N.M.C. department oriental medicine (대학부속한방병원 및 국립의료원 한방진료부 뇌졸증환자에 대한 한방치료 현황 분석)

  • Shin, Hyun-Kyoo
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 1995
  • The clinical study was carried out on 1737 cases of inpatient and outpatient which have been diagnosed as C.V.A at hospital attached to 8 colleges of oriental medicine in Korea or National Medical Center from January 1st 1994 to December 31st 1994. The results were as follows; 1. In this study, the case of Occlusive C.V.D was 70.1%, Cerebral hemorrhage was 20.5%, Transient ischemic attack (T.I.A) was 5.3%, Subdural hemorrhage was 3.0%, Subarachnoid hemorrhage was 0.8% 2. It was confirmed by C.T (20%), E.K.G. (19%), X-ray (19%), Urinalysis (19%), Hematoscopy (20%). 3. The mean days of hospital treatment was 27.88 days, mean days of ambulation was 70.34 days. The mean days of hospital treatment of Occlusive C.V.D, Cerebral hemorrhage, T.I.A., Subdural hemorrhage, Subarachnoid hemorrhage were 25.79, 39.32, 12.49, 16.23, 23.40 days, respectively. The mean days of ambulation of Occlusive C.V.D, Cerbral hemorrhage, T.I.A., Subdural hemorrhage, Subarachnoid hemorrhage were 74.40, 93.68, 69.10, 29.75, 32.57 days, respectavely. 4. Oriental medical treatment of C.V.A was mainly Acupuncture (25%), Paper of Chinese herbs (22%), Chinese physiotherapy (14%), Extract of Chinese herbs (11%). 5. Oriental medical physiotherapy for C.V.A was mostly E.S.T., Kinesiatrics, electric negative therapy, others Aerohydrotherapy, interferential current therapy (I.C.T.), Carbon, Samhogi, T.E.N.S., Ultra-sound, Infra-red, Microwave, T.D.P., Ultraviolet, S.S.P., Chinese herbs beth, Prarffin bath, Magnetic treatment and tractions.

  • PDF

Instantaneous Voltage Control Scheme of Auxiliary Power Supply System for Electric Railway Vehicles (철도차량 보조전원장치의 순시전압제어)

  • 김재식;최재호;임성수;이은규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.349-356
    • /
    • 1999
  • This paper presents an instantaneous voltage control scheme of au킹liary power supply system for the electric railway v vehicles, The resonance problem of the LC filter and the existing steady state error are more serious as the use of l instantaneous voltage control techniques for the fast transient response at the nonlinear load, A filter capacitor current f feedback loop is considered to increase the damping ratio of the voltage transfer function for the suppression of the resonance problem of the LC inverter output filter. To eliminate the steady state en‘or existing in case of the AC l instantaneous voltage control. the high gain transfer function is added to the conventional PI controller. The theoretical a analysis is well described with the simulation results. The validity of the proposed schemes is well verified through the s simulation and expelimental results for the 5 kVA prototype.

  • PDF