• Title/Summary/Keyword: Current reference

Search Result 2,345, Processing Time 0.028 seconds

Recent Developments and Trends of Digital Reference Service (디지털참고정보서비스의 최근 개발동향)

  • 김석영
    • Journal of the Korean Society for information Management
    • /
    • v.19 no.4
    • /
    • pp.214-231
    • /
    • 2002
  • This paper describes recent developments and trends of digital reference services. A brief overview of selected research on issues surrounding digital reference service is provided. It also discusses how technological developments in libraries have led to the emergence of new service paradigms. This paper briefly reviews reference and information services provided by libraries, those from publishers, those provided by experts, and those where users need to conduct a search and find information through the web. The current trend shows that the cooperative model is increasingly popular. Some projects on collaborative digital reference services(CDRS) are introduced. Librarians will need to continue analyzing the need for cooperative work in the reference service in a digital environment.

Investigating Factors Affecting Automated Question Triage for Social Reference: A Study of Adopting Decision Factors from Digital Reference

  • Park, Jong Do
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.49 no.1
    • /
    • pp.483-511
    • /
    • 2015
  • The efficiency and quality of the social reference sites are being challenged because a large quantity of the questions have not been answered or satisfied for quite a long time. Main goal of this study is to investigate important factors that affect the performance of question triage to relevant answerers in the context of social reference. To achieve the goal, expert finding techniques were used to construct an automated question triage approach to resolve this problem. Furthermore, important factors affecting triage decisions in digital reference were first examined, and extended them to the social reference setting by investigating important factors affecting the performance of automated question triage in the social reference setting. The study was conducted using question-answer pairs collected from Ask Metafilter. For the evaluation, logistic regression analyses were conducted to examine which factors would significantly affect the performance of predicting relevant answerers to questions. The results of the current study have important implications for research and practice in automated question triage for social reference. Furthermore, the results will offer insights into designing user-participatory digital reference systems.

Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line (전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Efficient Rotor Fault Detection of Induction Motors Using Stator Current Spectrum Monitoring (고정자 전류 스펙트럼 모니터링을 이용한 효과적인 유도전동기 회전자 고장 걸출)

  • 정춘호;우혁재;송명현;강의성;김경민
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.6
    • /
    • pp.873-878
    • /
    • 2002
  • Stator current spectrum by the fast Fourier transform (FFT) of current signals has been widely used for fault detection in induction motors. In this paper, we propose efficient rotor fault detection of Induction motors using stator current spectrum monitoring. The proposed method utilizes the mean absolute difference (MAD) between a Predetermined reference vector and a feature vector extracted from the stator current spectrum. Our proposed approach requires a smaller amount of computations when compared to fault detection algorithms based on neural networks, since it uses simple MAD criterion to detect rotor faults related broken rotor bars. Experimental results show that our proposed method can successively detect the rotor fault of the induction motor.

Current Conservation Factors for Consistent One-Dimensional Neutronics Modeling

  • Lee, Kibog;Joo, Han-Gyu;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.235-243
    • /
    • 2000
  • A one-dimensional neutronics formulation is established within the framework of the nonlinear analytic nodal method such that it can result in consistent one-dimensional models that produce the same axial information as their corresponding reference three-dimension81 models. Consistency is achieved by conserving axial interface currents as well as the planar reaction rates of the three-dimensional case. For current conservation, flux discontinuity is introduced in the solution of the two-node problem. The degree of discontinuity, named the current conservation factor, is determined such that the surface averaged axial current of the reference three-dimensional case can be retrieved from the two-node calculation involving the radially collapsed group constants and the discontinuity factor. The current conservation factors are derived from the analytic nodal method and various core configurations are analyzed to show that the errors in K-eff and power distributions can be reduced by a order of magnitude by the use of the current conservation factor with no significant computational overhead.

  • PDF

DC Current Transducer Using Saturable Magnetic Cores (포화자성코어를 이용한 직류전류측정 트랜스듀서)

  • Park, Young-Tae;Jung, Jae-Kap;Gang, Jeon-Hong;Ryu, Kwon-Sang;Yu, Kwang-Min
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.4
    • /
    • pp.138-142
    • /
    • 2004
  • Uncertainty and characteristics of the developed current sensor by means of two identically wound magnetic cores forming a ring like for measurement of a low DC current such as leakage current was described in this paper. This transducer consists of a sensor type of a current transformer, peak value detectors, a reference alternating low frequency voltage oscillator, precision measuring circuits to measure the output signals of sensor with harmonics, and can be measured up to 2 A at DC current. The resolution and sensitivity of the sensor were 0.1㎃ and 10㎷/㎃, respectively.

Medical Radiation Exposure in Children CT and Dose Reduction (소아 CT 촬영시 방사선 피폭과 저감화 방법)

  • Lee, Jeong-Keun;Jang, Seong-Joo;Jang, Young-Ill
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.356-363
    • /
    • 2014
  • Recently pediatric CT has been performed by reduced dose according to tube current modulation이라고, this fact has a possibility more reduce a dose because of strong affect depend on tube current modulation. Almost all MDCT snow show and allow storage of the volume CT dose index (CTDIvol), dose length product (DLP), and effective dose estimations on dose reports, which are essential to assess patient radiation exposure and risks. To decrease these radiation exposure risks, the principles of justification and optimization should be followed. justification means that the examination must be medically indicated and useful. Results is using tube current modulation이라고 tend to the lower kV, the lower effective dose. In case of use a low dose CT protocol, we found a relatively lower effective dose than using tube current modulation. Average effective dose of our studies(brain, chest, abdomen-pelvis) less than 47%, 13.8%, 25.7% of germany reference dose, and 55.7%, 10.2%, 43.6% of UK(United Kingdom) reference dose respectively. when performed examination for reduced dose, we must use tube current modulation and low dose CT protocol including body-weight based tube current adaption.

Design of a DC-DC converter for intra-oral CMOS X-ray image sensors (Intra Oral CMOS X-ray Image Sensor용 DC-DC 변환기 설계)

  • Jang, Ji-Hye;Jin, Li-Yan;Heo, Subg-Kyn;Josonen, Jari Pekka;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2237-2246
    • /
    • 2012
  • A bias circuit required for an oral sensor is manufactured inside the oral sensor chip to reduce its size and cost. The proposed DC-DC converter supplies the required reference and bias currents for their corresponding regulators by using IREF of the reference current generator. Their target voltages of the voltage regulators are regulated by the negative mechanism by generating their reference voltages required for their corresponding regulators. In addition, a constant current IB0/IB1 is supplied by being mirrored by a current mirror ratio and then VREF is generated. It is confirmed by measurements that the average volatge, ${\sigma}$, and $4{\sigma}$ of the designed DC-DC converter for intra oral sensors with a $0.18{\mu}m$ X-ray CMOS process are within their required ranges. And the line-pair pattern image shows a high-resolution characteristic without blurring. Also, a good oral image can be obtained.

Fast Scene Change Detection Algorithm

  • Khvan, Dmitriy;Ng, Teck Sheng;Jeong, Jechang
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.11a
    • /
    • pp.259-262
    • /
    • 2012
  • In this paper, we propose a new fast algorithm for effective scene change detection. The proposed algorithm exploits Otsu threshold matching technique, which was proposed earlier. In this method, the current and the reference frames are divided into square blocks of particular size. After doing so, the pixel histogram of each block is generated. According to Otsu method, every histogram distribution is assumed to be bimodal, i.e. pixel distribution can be divided into two groups, based on within-group variance value. The pixel value that minimizes the within-group variance is said to be Otsu threshold. After Otsu threshold is found, the same procedure is performed at the reference frame. If the difference between Otsu threshold of a block in the current frame and co-located block in the reference frame is larger than predefined threshold, then a scene change between those two blocks is detected.

  • PDF

A Sensorless Speed Control of an Interior Permanent Magnet Synchronous Motor based on an Instantaneous Reactive Power (순시 무효전력을 이용한 매입형 영구자석 동기 전동기의 센서리스 속도제어)

  • Kang Hyoung-Seok;Joung Woo-Taik;Kim Young-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.107-115
    • /
    • 2006
  • In this paper, a new speed sensorless control based on an instantaneous reactive power is proposed for the interior permanent magnet synchronous motor(IPMSM) drives. In proposed algorithm, the current observer estimates the line currents and the estimated speed can be yielded from the voltage equation because the information of speed is included in back EMF. To implement speed sensorless control, the current observer is composed by using the voltage equation of the IPMSM in the stationary reference frame fixed to the stator. The estimated speed of the rotor is composed by using the voltage equation of the IPMSM in the rotating reference frame fixed to the rotor The estimated speeds to minimize the speed error compensated by using the instantaneous reactive power. The instantaneous reactive power is calculated on the rotating reference frame fixed to the rotor. The effectiveness of the preposed algorithm is confirmed by the experiments.